Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.8 LAccepted-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L-1 | Accepted-AOC Found Lowest One | |
| 2 | L-2₹35.4 L+₹3.6 L (11.2%)Rejected-Finance V P O SEHAL TEHSIL BAIJNATH DISTT KANGRA H P | MANDI | HIMACHAL PRADESH | 175013 | L-2 | Rejected-Finance High rate quoted | |
| 3 | L-3₹36.3 L+₹4.5 L (14.1%)Rejected-Finance VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L-3 | Rejected-Finance High rate quoted | |
| 4 | L-4₹40.0 L+₹8.2 L (25.7%)Rejected-Finance NOT MENTIONED | L-4 | Rejected-Finance High rate quoted | |
| 5 | L-5₹41.2 L+₹9.4 L (29.4%)Rejected-Finance | L-5 | Rejected-Finance High rate quoted |
Tender Value
₹22.0 L
EMD Value
₹40,538
Closing Date
27 Sept 2021, 11:00 amClosed
EXECUTIVE ENGINEER
JAL SHAKTI DIVISION PALAMPUR
Supplying and Errection of pumping Machinery with allied accessories and Laying and Jointing of R Main
2021_HPIPH_52534_1
HP IPH 2021 11031-65 DATED 20.09.2021
Open Tender
Civil Works
Item Rate
365 days
PALAMPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹400
₹40,538
Yes
3 Aug 2023
20 Sept 2021
27 Sept 2021
20 Sept 2021
27 Sept 2021
20 Sept 2021
Amount
Pumping machinry(Stage Ist ) Providing & supplying of raw water ubmersible KRTE pump set capable of handling high thread turbidity of KSB/ Kalama/SU/Johnson/Crompto/ make single and open impeller raw water handling pump confirming to latest BIS code.The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/ grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft .The impeller of pump shall be directly mounted on extended submersible square cage motor shaft conforming to BIS-9238-1979 with upto date ammendments of 2900 RPM, totally dust & weather proof with detach able pump casing for easy inspection with double mechanical seal grease/ oil lubricated and provided with stainless steel thrustbearing plate to withstand vertical load with minimum wear & tear .It should be fitted with device to take up expension of water on heating of motor & suitable for operation on 415 +/-10% volts 3 phase 50 C/S AC supply.The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/duck foot bend ,steel guide wire with mounting hook lowering chain and standard accessories as supplied by the manufacturers complete and suitable for fulfilling the the following requirements:- i) Total Head 23.70 Mtrs ii) Discharge required from each pump. 10.60 LPS iii) No. of pump required 2 Nos iv) Location of the site of inatallation of machinery. The site is located at Santinaggar ( Mand Khad) v) The Altitude of installation. The altitude of place is 900 mtrs above MSL vi) Type of current. AC Three phase/single phase vii) Rate Voltage 415V+ 10% viii) Type of water and its source Raw water. ix) Shaft level 696.6 Mtr x Level of discharge point 716.6 Mtr xix) Static head in Mrs 20.00 mtrs. xii Charactristics of water. - xiii a) Ambient Temperature dig .C xvi) b)Turbidity NTU 10NTU xv c)Hardness260Mg/Ltrs(as CaCO3) - xvi d) PH 7.5 - xviii) e)Total solid Mg /Ltrs - xviii) f)Other - xix) Depth of Well Assembly ~ xx No of workinh hours per day 16.00 hours xxi Length of R/Main 120 mtrs. xxii) Dia of Rising main 125 MM xxiii Limit of pump operation. in thre completem Range of (-) 75% xxiv R.P.M. of pumping set. 2900 RPM ( or to be specified by the tenderer) xxv Test run. 16 Hours continueously for 7 days
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for Submersible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump of rating 10.00 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec
i) Variable frequency drive starter of 10.00 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES
ii) Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens
iii) Main incomer MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.
iv) LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.
v) LED On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc.
vi) Slector Switch for Auto and manul Operation
vii) Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should bo proper protection in case of any voltage surge and distortions.
viii) Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. Make: Aarmation Electric Private Limited/MAS/ELLES
ix) Power and Control wiring and Busbar
x) Surge suppressor device with isolating MCCB to eliminate the power surges due to lightening and system surges.
xi) Power quality monitoring & controling realy with Control Contactor to safeguard the Electronic & Electric elements
xii) Independent Control panel with swithch fuse unit and fuses of Suitabvle Amperage to eliminate the kitkat fuses of HPSEB Make: Aarmation Siemens/Schneider/L&T
xiii) PLC (Programmable logic controller ) with appropriate digital and anlog inputs and output to give automatic command to Star Delta Starter panel/ Energy saving variable frequency starter Make: Aarmation Bechoff Automation/Rockwell Automation
xiv) Electronic realy card 8 channel
xv) SMPS 4.5 Amps to energise PLC system
xvi) HMI (Humen Machine Interface) 7" display for Monitoring and Contriling of Submersible pumps Make: Aarmation Bechoff Automation/Rockwell Automation
xvii) Control MCB for Automation System
xviii) Level Sensor to indicate the water level of tank remotely
xviii) Shieldede data Cable for communication of level Sensor with PLC
xx) Installation and Commissioning and software Development for all above item complete all respect Engineer-in-charge
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast Iron double flanged sluice valve class PN1.6 confirming to BIS-1414(API600) latest edition (to be provided on Delivery side)of equal size to the dia of dilivery of pump and capable of with standing nominal seat test pressure of 10.20 kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I. double flanged swing check type reflux valve class PN 1.6 vconfirming to BS 1868 (API 600) latest adition (to be provided on Delivery side of size one step heigher than the dia of delivery size of pump and and shall be suitable for withstanding nominal seat pressure of 10.20 kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I. double flanged swing check type reflux valve having by pass arrangement of class PN 1.00 confirming to BIS 5312-2000 (latest adition )to be provided on R/main of 125 mm dia and shall be suitable withstanding nominal seat pressure of 16.00 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
i) On supply side of 3½ core coper cable 4mm^2 ( From HPSEB Meter to Switch &Starter).
ii) On motor side 3 core flat joint less copper cable of size 2.5 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
P/Laying of G.I./MSERW pipe of suitable size ( layout to be approved by the Engineer -in-charge) for sunction delivery and common header considering site requirements and NPSH required /available. The pipe size for sunction and delivery shall as per requirement of offered pump and common header shall be equal to dia of Rising main including taper, flanges, ends, rubber gasket, 3mm thickness as per IS : 2712-1979 and required number of nuts and bolts upto 5 metre from the outer wall of the pump house as per layout approved by the Engineer in Charge as per IS 1364-1983. The pipes material shall conform to relevent BIS codes and capable of with standing field test pressure equal to 1.5 times the operating pressure. The complete arrangement shall comprise of:
i) a) Sunction Pipe Dia to be specified by the tendrer
ii) a) Delivery Pipe Sunction Pipe Dia to be specified by the tendrer
a) Common Header Dia to be specified by the tendrer
Actual laying to be done as per final drawing to be approved by the Engineer in charge
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage 2nd Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latest with upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below. i)Total Head 228.07 Mtrs. ii)Discharge required from each pump. 10.76 LPS for each pump. iii)No. of pump required 2.00 Sets iv)Location of the site of installation of machinery The site is located at a distance of 35 Kms from Palampur . v)The altitude of installation. Altitude of place is 900 m above MSL vi)Type of current. AC three phase supply with freqduency of 50 cycle per second. vii)Rate Voltage 415V + 10% viii)Type of water and its source Clear water ix)Shaft level 710.35 mtr x)Level of discharge point 928.35 metre xix) Static Head 218.00 metre xii)Charactristics of water. a) Ambient Temperature dig.c (b) Turbidity NTU 10 NTU (c)Hardness260Mg/Ltrs(as CaCO3) (d)PH 7.5 (e) Total solid Mg/ltrs (f) Other xiii)Depth of well assembly xvi) No. of working hours per day 16.00 hours Length of R/main 750 metre Dia of R/Main 150 mm xvii) Limit of pump operation. In the completem Range of (-)75% xviii) R.P.M. of pumping set. 2900 RPM (or to be specified by the tenderer). xix) Test run 8 hours continueously for 7 days.
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for Centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof, wall,base mounted and front opering door type with copper insulated wiring suitable to operate 2 nos. pump ( 1 working & 1 stand by) each of the rating 70.00 HP Starter should be capable enough to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry run. protection and phase loss with LED ON/OFF & TRIP indicators , power Quality Monitoring & Controlling Realy at the incomer Feeder,should be fitted with surge Suppressor Device suitable to protect against class-1 & 2 surges Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec
i) Variable frequency drive starter of 70.00 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES
ii) Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens
iii) Main incomer MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.
iv) LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.
v) LED On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc.
vi) Slector Switch for Auto and manul Operation
vii) Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should bo proper protection in case of any voltage surge and distortions.
viii) Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. Make: Aarmation Electric Private Limited/MAS/ELLES
ix) Power and Control wiring and Busbar
x) Surge suppressor device with isolating MCCB to eliminate the power surges due to lightening and system surges.
xi) Power quality monitoring & controling realy with Control Contactor to safeguard the Electronic & Electric elements
xii) Independent Control panel with swithch fuse unit and fuses of Suitabvle Amperage to eliminate the kitkat fuses of HPSEB Make: Aarmation Siemens/Schneider/L&T
xiii) PLC (Programmable logic controller ) with appropriate digital and anlog inputs and output to give automatic command to Star Delta Starter panel/ Energy saving variable frequency starter Make: Aarmation Bechoff Automation/Rockwell Automation
xiv) Electronic realy card 8 channel
xv) SMPS 4.5 Amps to energise PLC system
xvi) HMI (Humen Machine Interface) 7" display for Monitoring and Contriling of Submersible pumps Make: Aarmation Bechoff Automation/Rockwell Automation
xvii) Control MCB for Automation System
xviii) Level Sensor to indicate the water level of tank remotely
xix) Shieldede data Cable for Communication of level Sensor with PLC
xx) Installation and Commissioning and software Development for all above item complete all respect Engineer-in-charge
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast steel double flanged accutated sluice valve of class ASA-300 confirming to BIS-1414(API-600) (to be provided on delivery side) of equal size to one dia more than the dia of delivery of pump and capable of with standing nominal seat test pressure of 52 kg/cm².
NOTE:-The Cast steel sluice valve shall conform to BIS:780-1984 for 50 to 300mm dia & BIS:2906-1984 for 350 to 1200mm dia ( latest edition). However if seat pressure exceeds the limits prescribed in above mentioned BIS, then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 52 Kg/cm² or class ASA-300 for seat pressure 52 Kg/cm² as per BS 1414 (API 600) .
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on delivery side) of size one step higher than the delivery size of pump and shall be suitable for withstanding nominal seat pressure of 52kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on Rising main) of 80 mm and shall be suitable for withstanding nominal seat pressure of 52__ kg/cm².
NOTE:- The Cast steel reflux valve shall conform to BIS: 5312-1984- Part-I ( latest edition). However if the seat pressure exceeds the limits prescribed in BIS 5312 then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/cm² or class ASA-300 for seat pressure 52 Kg/cm² as per BS 1868 (API 600)
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I double flanged sluice valve class PN-I confirming to BIS 780-1984 to be provided on Suction side of size one dia higher then the suctrion size of pump capable of withstanding nominal seat pressure of 10.20__ kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 50 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 25 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of. NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Suction Pipe = xxx to be specified by thew Tenderer
Delivery pipe = xxx to specified by thew Tenderer
Common header = 125 mm dia
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries).
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Centrifugal pumping Machinery Stage 3rd Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latest with upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below. i)Total Head 54.51 Mtrs. ii) Discharge required from each pump. 2.86 LPS . iii)No. of pump required 2 Nos iv)Location of the site of installation of machinery The site is located atSantinagar ( mand Khad ). v)The altitude of installation. Altitude of place is 900 m above MSL vi)Type of current. AC three phase/singal phase . vii)Rate Voltage 415V + 10% viii)Type of water and its source Clear water ix)Shaft level 870.88 mtr x)Level of discharge point 927.41 metre xix) Static Head Mrs 56.53 metre xii)Charactristics of water. -- a) Ambient Temperature dig.c (b) Turbidity NTU 10 NTU (c)Hardness260Mg/Ltrs(as CaCO3) (d)PH 7.5 (e) Total solid Mg/ltrs (f) Other xiii)Depth of well assembly xvi) No. of working hours per day 16.00 hours Length of R/main 650 metre Dia of R/Main 80 mm xvii) Limit of pump operation. In the completem Range of (-)75% xviii) R.P.M. of pumping set. 2900 RPM (or to be specified by the tenderer). xix) Test run 16 hours continueously for 7 days.
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for Centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof, wall,base mounted and front opering door type with copper insulated wiring suitable to operate 2 nos. pump ( 1 working & 1 stand by) each of the rating 20.00 HP Starter should be capable enough to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry run. protection and phase loss with LED ON/OFF & TRIP indicators , power Quality Monitoring & Controlling Realy at the incomer Feeder,should be fitted with surge Suppressor Device suitable to protect against class-1 & 2 surges Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec
Variable frequency drive starter of 20.00 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens
Main incomer MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.
LED On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc.
Slector Switch for Auto and manul Operation
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should bo proper protection in case of any voltage surge and distortions.
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. Make: Aarmation Electric Private Limited/MAS/ELLES
Power and Control wiring and Busbar
Surge suppressor device with isolating MCCB to eliminate the power surges due to lightening and system surges.
Power quality monitoring & controling realy with Control Contactor to safeguard the Electronic & Electric elements
Independent Control panel with swithch fuse unit and fuses of Suitabvle Amperage to eliminate the kitkat fuses of HPSEB Make: Aarmation Siemens/Schneider/L&T
PLC (Programmable logic controller ) with appropriate digital and anlog inputs and output to give automatic command to Star Delta Starter panel/ Energy saving variable frequency starter Make: Aarmation Bechoff Automation/Rockwell Automation
Electronic realy card 8 channel
SMPS 4.5 Amps to energise PLC system
HMI (Humen Machine Interface) 7" display for Monitoring and Contriling of Submersible pumps Make: Aarmation Bechoff Automation/Rockwell Automation
Control MCB for Automation System
Level Sensor to indicate the water level of tank remotely
Shieldede data Cable for Communication of level Sensor with PLC
Installation and Commissioning and software Development for all above item complete all respect Engineer-in-charge
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast Iron double flanged sluice valve class PN 1.0 confirming to BIS-780-1984 (to be provided on R/main side) capable of with standing nominal seat test pressure of 10.20 kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I. double flanged swing check type reflux valve class PN 1.0 vconfirming to BS 5312-1984 having bye pass arrangement (to be provided on R/main side) and shall be suitable for withstanding nominal seat pressure of 10.20 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 4mm^2 ( From HPSEB Meter to Switch &Starter).
On motor side 3 core flat joint less copper cable of size 2.5 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
P/Laying Column assembly of G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. Column assembly =125 mm dia G.I.flanged pipe(medium grade) NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Rising Main Excavation in foundations and trenches (for pipes and pits) upto all depths etc. in all kinds of soil such as pick work, jumper work and saturated soil including bailing or pumping out of water, blasting in soft/hard rock or chiseling or wedging out of same where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring strutting, planking timbering and dewatering wherever required, stacking usable and unusable material/soil separately and after laying jointing and testing of pipes, returning he usable soil in 15 cm layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed within all leads and lifts including restoration of unmetaled/ mattelled surfaces to its original condition and including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lifts as per the direction of Engineer-in-charge.
Laying jointing and testing of bevelled ended G.I. pipe (Medium class) with circumfernital butt welded joints (94%) by electric arc welding thickness shall be equal to pipe wall thickness)and testing of G.I. pipe of following dia confirming to ISI 1239-1990 (part-III) having wall thickness as specfied below capable of with standing required test pressure including manufacturing and fabrication of reducers/tapers all short pieces required degree of bends etc. as per site requirement made from parent tubes the laying of pipe shall also providing MS flanged of required table including welding of flanges joints of pipe (6%) duly welded including nuts, bolts & gasket separately). the welding electrodes shall be as per IS: 814 of Advani oerlikon/L&T of ISI marked make the damaged portion of pipes (if damages during laying and joints operation of pipe). The rates also including entire carriage of material flushing cleaning and hydraulic testing of pipes D.P. test of butt welded joints complete in all respect and to the best satisfaction and direction of Engineer-in-Charge complete within all leads and lifts.
2nd stage R/Main 0 to 480 150 mm G.I Medium 4.80 17
480 to 750 150 mm G.I Medium 4.80 5
3rd Stage 0 to 420 80 mm G.I Medium 4.80 17
420 to 650 80 mm G.I Medium 4.80 5
Sunny Kapoor
SANJAY SAINI
MANAHOR LAL SURINDER KUMAR
Bharat Engg and Suppliers
sadeep kumar
dinesh kumar lath
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .