Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-Finance | L1 | Accepted-Finance BID IN ORDER | |
| 2 | L2₹3.1 L+₹3,496.08 (1.13%)Accepted-Finance | L2 | Accepted-Finance BID IN ORDER |
Tender Value
₹2.9 L
EMD Value
₹3,700
Closing Date
21 Apr 2023, 5:00 pmClosed
SO EnM
SO EnM Office, Rajrappa Area
Complete rewiring of quarter No- C-1/1, C-1/2, CTS-6/36, D2(NEW) and D11(NEW) under Rajrappa Township of Rajrappa Area
2023_CCL_276960_1
GM(R)/SO(EnM)/Rjp/23-24/Et/02 dt 05.04.2023
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
RAJRAPPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,700
4 Mar 2024
6 Apr 2023
22 Apr 2023
7 Apr 2023
21 Apr 2023
7 Apr 2023
7 Apr 2023 - 10 Apr 2023
Amount
Wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.
Group A
Group B
Group C
Wiring for light power plug with 2 x 4.0 sqmm FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit along with 1 no 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 *1.5 sq.mm +1 * 1.5 sq. mm earth wire
2 * 2.5 sq. mm + 1* 2.5 sq. mm earth wire
2 * 4 sq. mm + 1 * 4 sq. mm earth wire
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required
3 pin 5/6 A socket outlet
5/6 A switch
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc . as required.
Supplying and fixing 3 pin, 5A celling rose on the existing junction box / wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing of PVC box of following sizes(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
100 mm x 100 mm x 60mm deep
180mm x 100 mm x 60mm deep
200mm x 150mmx 60mm deep
200mm x 250mm x 60mm deep
Supplying and fixing 5A to 32A rating, 240/415V, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single Pole
Double pole
Supply and fixing following way single pole and neutral, sheet steel MCB distribution board, 240 Volt on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted incluing earthing etc.as required(but without MCB/RCCB/isolator, 6 way double door)
Supply and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 1x1.5 sqmm
Supplying and fixing of 32A 240/415V 2 pole switch fuse unit
Total impact of GST for the purpose of CTC
Coalfield Construction
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_286722.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .