| Sl No | Description | Qty | Unit | P.Thankappan Nair L2 | SYNERGY POWER TECH L1 | STEPHEN MOSES L3 |
|---|---|---|---|---|---|---|
| 1.00Electrification | ||||||
| 1.00 | OD181242/2025-2026:Wiring through EXISTING CONDUIT - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C | 10 | point | 751.81 ₹7,518.10 | 859 ₹8,590 | 939 ₹9,390 |
| 1.00 | OD200501/2025-2026:Wiring through EXISTING CONDUIT - Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | 2 | point | 451.51 ₹903.02 | 515 ₹1,030 | 564 ₹1,128 |
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 10 | point | 1,381.42 ₹13,814.20 | 1,250 ₹12,500 | 1,726 ₹17,260 |
| 1.00 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | 6 | each | 1,021.3 ₹6,127.80 | 1,050 ₹6,300 | 1,276 ₹7,656 |
| 1.00 | OD181324/2025-2026:Supply and fixing 1500 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required | 66 | each | 1,609.32 ₹1.1 L | 1,750 ₹1.2 L | 1,800 ₹1.2 L |
| 1.01 | OD204262/2025-2026:Supply and fixing 3000 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea complete with all accessories and fluorescent lamps etc. suspended from ceiling using 4 nos steel chain (16 SWG or nearest) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (Philips FullGlow / Crompton POLARIS NIO / Wipro Immaculate or equivalent) (including frame, if necessary) | 66 | each | 3,300.72 ₹2.2 L | 2,900 ₹1.9 L | 3,800 ₹2.5 L |
| 1.01 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | 62 | each | 151.22 ₹9,375.64 | 145 ₹8,990 | 120 ₹7,440 |
| 1.01 | 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: | 61 | each | 2,369.98 ₹1.4 L | 2,740 ₹1.7 L | 2,962 ₹1.8 L |
| 1.01 | OD187161/2025-2026:Supply, installation, testing and commissioning of 900 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC), class of insulation B, 3 no:s blades, 30 cm long down rod, 2 no:s canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00, air delivery minimum 210 cum/min, 350 RPM (tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control, and all remaining accessories including safety pin, nuts and bolts, washers, temperature rise equal to 75 degrees Celsius (maximum), insulation resistance more than 2 Megaohm, suitable for 230V, 50 Hz, single-phase AC supply, earthing etc., complete as required. | 1 | each | 1,872.8 ₹1,872.80 | 2,300.7 ₹2,300.70 | 2,341 ₹2,341 |
Tender Value
₹13.2 L
EMD Value
₹32,901
Closing Date
13 Nov 2025, 6:00 pmClosed
Executive Engineer
PWD Electrical Division Thiruvananthapuram
GENERAL-Construction of Five Storied Building for Vigilance and Anti-corruption Bureau office in TVM at Muttathara, Thiruvananthapuram - Phase 1-Electrification-General Electrical Work-1-Balance electrical work for Cellar and Ground floor
2025_PWD_819579_1
EDT_ET_28_2025_26
Open Tender
Electrical Works
120 days
Thiruvananthapuram
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
Yes
₹32,901
Yes
23 Jan 2026
6 Nov 2025
17 Nov 2025
6 Nov 2025
13 Nov 2025
6 Nov 2025
Amount
Electrification
OD181242/2025-2026:Wiring through EXISTING CONDUIT - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD200501/2025-2026:Wiring through EXISTING CONDUIT - Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD181324/2025-2026:Supply and fixing 1500 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required
OD204262/2025-2026:Supply and fixing 3000 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea complete with all accessories and fluorescent lamps etc. suspended from ceiling using 4 nos steel chain (16 SWG or nearest) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (Philips FullGlow / Crompton POLARIS NIO / Wipro Immaculate or equivalent) (including frame, if necessary)
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
OD187161/2025-2026:Supply, installation, testing and commissioning of 900 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC), class of insulation B, 3 no:s blades, 30 cm long down rod, 2 no:s canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00, air delivery minimum 210 cum/min, 350 RPM (tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control, and all remaining accessories including safety pin, nuts and bolts, washers, temperature rise equal to 75 degrees Celsius (maximum), insulation resistance more than 2 Megaohm, suitable for 230V, 50 Hz, single-phase AC supply, earthing etc., complete as required.
OD181330/2025-2026:Supply and installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. 300/305 mm sweep Light Duty Exhaust fan
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD181335/2025-2026:Supply conveyance, installation ,testing and commissioning of LED bulkhead fittings IP 65 directly on wall including cutting necessary holes giving connection with the extended original wiring making good the damages colour washing etc as required(Make Philips/Bajaj/Havel/Wipro)
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
OD198179/2025-2026:Supply and fixing 20mm PVC corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size of GI/ painted MS saddles
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
P.Thankappan Nair (BID ID -2435352)
STEPHEN MOSES (BID ID -2437942)
Bidder Name
STEPHEN MOSES
P.Thankappan Nair
SYNERGY POWER TECH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
pre-agreement.pdf
Other Document • 0.54 MB
FoT.pdf
Other Document • 0.37 MB
Affidavit.pdf
Other Document • 0.47 MB
MoM.pdf
Other Document • 0.48 MB
IP.pdf
Other Document • 0.20 MB
epayment.pdf
Other Document • 0.20 MB
BOQ_1373957.xls
BOQ • 0.33 MB
viewsbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid