ASSISTANT ENGINEER
ASSISTANT ENGINEER,LSGD SECTION, NEDUVATHOOR GP, KOTTARAKKARA BP,KOLLAM
CMLRRP 2020-21 MURINGAMOODU THENGUVILA JUNCTION ROAD CONCRETING AND SIDE PROTECTION IN NEDUVATHOOR GP
2020_LSGD_389916_2
01/03/2020/AE/LSGD/NDVR
Open Tender
Civil Works - Roads
Item Rate
120 days
NEDUVATHOOR GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
online
₹44,650
Yes
17 Jan 2021
8 Oct 2020
23 Oct 2020
8 Oct 2020
19 Oct 2020
8 Oct 2020
120 days
Amount
Retaining wall
od856552/2020_2021 : RING BUND Type II Putting up ring bund with earth fille gunny bags of top width 1.0mbottom width<br>2.0m height 2.0 m side and filling in between with earth to form ring bund and maintaining thesame<br>leak proof till the completion of the work and clearing the site by dismantling the bund aftercompletion<br>of the work.etc.complete.
od856553/2020_2021 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set<br>including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc<br>complete<br>
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
od857452/2020_2021 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
od856556/2020_2021 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6 (modified 11.4.1.1 form work excluded)
od909743/2020_2021 : DR PACKING Under foundation - Dry stone packing under foundation with good<br>quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site
11.4.4 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
13.1.1.1 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5I.R.C.C grade M 20(i)For nominal mix 1:2:4
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
od856558/2020_2021 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per<br>manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even<br>shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10<br>sqm of approved brand and manufacture
od857456/2020_2021 : Filling up low laying and water logged areas with local material/quarry muck ,spreading in layers,levelling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
od857455/2020_2021 : Surface dressing of the ground in All kinds of soil including removing vegetation and<br>in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
od856559/2020_2021 : Plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 20 (grade),coarse and fine aggregates conforming to IS 383,maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork(steel channel, wedges,steel plates including levelling the formwork as per drawing),spreading the concrete with shovels,rakes,compacted using needle vibrator and finished in continuous operation including provision of contraction and expansion ,construction joints curing of concrete slabs for 14 days, water finishing to lines and grade as<br>per drawing and Technical"<br>Specifications clause 1501 (Form work included)
od893942/2020_2021 : Construction of plain cement concrete pavement ,thickness as per design,over a<br>prepared sub gradeor sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 20<br>(grade),coarse and fine aggregates conforming to IS(for new concrete work 2019-20)383,maximum size of<br>coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2cum capacity and<br>appropriate weigh batcher using approved mix design,laid in ,spreading the concrete with<br>showels,rakes,compacted using needle vibrators,and and finished in continuous operation including<br>provision of contraction and expansion ,construction joints,curing of concrete slabs for 14 days,with water<br>finishing to lines and grade as per drawing and Technical Specifications clause 1501(without formwork)
od856560/2020_2021 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to<br>1.5 m as per direction of site Engineer-in-charge."<br>
10.4.A.2 : Direction and Place Identification signs with size more than 0.9 sqm size board<br> A. Retro-reflectorised Traffic Signs <br>2 Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
CHIRAKADAVU CONSTRUCTION
Bidder Name
AJITH KUMAR S
CHIRAKADAVU CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .