Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹45.8 L+₹2.1 L (4.81%)Rejected-Finance 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
25 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
PROVN OF CERTAIN SANCTIONED WORKS AT AF STATION HALWARA
2021_MES_464919_2
GE/HAL-37/2021-22
Open Tender
Civil Works
Item Rate
183 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY a i and b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹87,200
Yes
23 Oct 2021
3 Sept 2021
27 Sept 2021
3 Sept 2021
25 Sept 2021
11 Sept 2021
60 days
Amount
Suface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specfied and directed.
Taking down cement plaster of any description thickness including raking out joints hacking for key scrubbing down with water all as specified.
Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces all as specified and directed
Demolition of stone slabs and tiles of any description or thickness Laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exc 15 cm thickness (below or above ground level) all as specified
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame area exc 1.5 Sqm but n.exc 4 Sqm each and refixing in same opening all as specified.
Taking down chowkhats or frame with shutter without taking off shutter from the frame area not exc 1.5 Sqm each complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises complete all as specified and directed .
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories)
Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide for foundations etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and getting out complete all as specified and directed. Notes : (i) Payment for excavation shall be made for one time in case the newcable is laid in the same trenches. (ii) Excavation upto top of brick protection shall be measured for payment purposes.
Excavation in post holes (or similar holes ) each n.exc 0.50 Cum, and getting out, returning filing in and ramming earth with broken rubble mixed with earth around in layers n.exc 25cm, watering etc and removing surplus soil n.exc 50m and making good surface in loose/soft soil complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated spoil to a distance not exc 50 mtr and depositing where directed not exc 1.5m above the starting point complete all as specfied and directed.
M&L for PCC 1:5:10 Type E-2 using 40mm crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class ‘B’ brick, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified
M&L for 15 mm thick cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement all as specified
All as per Srl item No 17 above but 15 mm thick in cement mortar 1:4 including water proofing compound mixed as per manufacturers instructions complete all as specified and directed. Note : Water proofing compound will be paid separately as supply only under respective items of this schedule.
M&L for providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-charge
M&L for providing and injecting chemical emulsion for Post Constructional Anti-termite at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed by Engineer-in-charge
M&L for providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified by Engineer-in-charge.
M&L for hardcore of broken stone or boulders guages not exc 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to true surface complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in sub base in floors complete all as specified and directed.
M&L for PCC (1;2:4) type B-1 using 20mm graded stone aggregete as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-charge.
M&L for Glazed ceramic coloured tiles (300x200mm) x6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for Non-skid jointless cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment over and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed.
M&L for vitrified ceramic coloured tiles 10 mm thick (Square/rectangular) area of each tile n.exc 0.36 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment over and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed.complete all as specified and directed.
M&L for granite stone slab 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 15mm thick screed bed of cement mortar 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situation complete all as directed .
S&F powder coated Anodised aluminium frame for doors, windows, ventilators or in partitions with one or more rebates including jointing cleats for fixing etc complete all as specified and directed
S&F powder coated Anodised aluminium window and ventilators shutters, aluminium section weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, aluminium fittings such as Peg stay 150mm long - 01 Nos, 100mm long handle 1 Nos, 100mm hinges 02 Nos in each shutter and anodised aluminum snap beading screws etc complete all as specified and directed.
S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, handle 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
S&F 12mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice laminations and other side balancing white, fixed in aluminum partitions/doors etc with screws complete all as specified and directed.
M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410-W Gde E-250 quality A
S&F pressed steel frames of size 125x60mm for doors made out of PBC sheet 1.25mm thick with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. and filling hollow portion of frame in PCC 1:3:6 type C0 (using 12.5mm graded stone aggregates) complete all as specified.
S&F pressed steel frames of size 105x60mm for doors made out of PBC sheet 1.25mm thick with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. and filling hollow portion of frame in PCC 1:3:6 type B0 (using 12.5mm graded stone aggregates) complete all as specified.
S&F 35 mm thick IInd class hard wood plain framed factory made paneled shutters with panel of 9 mm BWP commercial veneering on both veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS :1003 (part-I) kiln seasoned and chemically treated complete all as specified.
S&F 35 mm thick 2nd class hard wood glazed or skelton shutter factory made open rebated prepared to receive glass, gauge etc.without sash bars edges of framing plain fitted with cut & mitred beads for securing glass etc size of member all as per clause 8.23 (a) of SSR Part-I complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube , fixing in opening as complete all as specified and directed.
S&F 30 mm factory made solid panel PVC door shutter consisting of frame made out of MS tube for top and bottom rail,MS frame shall be covered with heat moulded plain colour PVC “C” channel having stip of 20 mm width stuck inside with solvent cement rail on either side and as gap inset for top rail and bottom rail, welded/sealed to the stiles and railes with suitable PVC sheet beading and joined together with solvent cement supply and fixing in the frame and site as specification all as specified.
S&F cabinet in required sizes at site made out of 18mm thick one side decorative lamination & other side balancing lamination sheet consisting of carcass 18 mm thick sheet & provision of shutters made out of 18 mm thick one side decorative laminated sheet all required Vrackets 5.5 Screws etc. the panels shall be fabricated using adhesive and screws where ever required. All edges shall be covered with 2 mm thick edge bonding tape or 90 degree edge bend finish including catchers shutters fixed with 75mm size stainless steel steel butt hinges in each pane, stainless steel handle 125mm long including taking down existing wooden/ block board cabinate complete
S&F cupboard shutter in required size at site made out of 20mm rigid PVC sheet consisting of carecase & provision of shutters, all required brackets 5.5 screws etc, the panel shall be fabricated using adhesive and screws where ever required. All edges shall be covered with 1mm edge bend tape 90 degree edge bent finish as per make and specifications. PVC shelf/partitions of required size consisting of panel of 20mm rigid PVC sheet and for supporting the hold of shelf/partition and shall provide 3 edges in size 20mmx20mm as per required length, the front size of the edge visible complete all as directed by Engr-in-Charge, manufacturers specifications including catchers shutter fixed with 75mm size stainless steel butt hinges in each panel, stainless steel handle 125mm long including taking out existing wooden/block board shutters with hardware complete all as specified and directed.
S&F stainless steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tined tacks complete all as specified and directed.
M&L for repairing RCC projection chajjas, roof, facia etc. by necessary preparation, scraping, cutting, chiseling derusting and cleaning exposed reinforcement surfaces of damaged, loose RCC surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and reinforcement with welded mesh of weight exc 2Kg per Sqm but n.exc 3Kg/Sqm (if required) with or without facia and finished with cement morte 1:3 using coarse sand and work in patches area n.exc 5 Sqm and thickness RCC member n.exc 70mm including necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete.
Mild steel TMT bars 10mm dia and over, cut to length bent to shape reqiored including cranking, bending spirally for hooping for columns, hooking ends and binding with including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Alll as per Sl item No 46 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm each panes complete all as specified
All as per Srl item No 48 above but pin head 4mm thick type sheet glass
S&F 100 mm size butt hinges medium weight cold rolled mild steel all as specified.
S&F 75 mm size butt hinges medium weight cold rolled mild steel all as specified.
S&F 50 mm size butt hinges medium weight cold rolled mild steel all as specified.
S&F 2nd class HW small fittings such as brackets of any type, latch and hing block, saved door and window stops and the like including all necessary labours articles n exc 200 cu cm each complete all as specified and directed.
S&F floor doors stoppers 150mm long of aluminium alloy body and tenque anodside with hard drawn steel spring fixed in floor complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section and fixed 200 mm long
S&F Aluminium handles cast type anodised 150mm long.
S&F 300 mm long aluminum anodised sliding door bolts, Aluminium alloy, door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium complete all as specified and directed.
S&F mild steel 300mm helical door spring , ordinary rat tail rod patteren including roller and roller plate complete all as specified and directed.
S&F stainless steel wire 20mm mesh size wire netting of wire 1.40mm dia welded in doors or fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge
Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and directed.
S&F 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S&F 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S&F in repair grating CP fixed 100mm dia.
S&F in repairs 15mm bore bib tap cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15mm bore stop valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
All as per srl item No 66 above but 20mm bore
All as per srl Item No 66 above but concealed type, fancy chromium plated with long shank and cup .
S&F in repairs vitreous china wash down water closet pedestal pattern pan white with trap including connection to existing out joint pipe, flushing pipe or Cistern, antisyphonage pipe, including making, etc complete including making goood to floor etc complete all as specified and as directed
S&F PVC connection 300 mm long, 15mm size with PTMT nuts complete all as specified in repairs
S&F in repairs 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as specified and directed.
S&F in repair 1000 ltr rotational moulded polyethylene water storage tank, triple layer wall construction (cylindrical vertical with closed top) hoisted and fixed in position including demolition of existing RCC tank of any description and removing the debris away from the site.
S & F 20mm bore ball valve high pressure PTMT with epoxy coated aluminium rod & high densitypolythene float ball and fly nut screwed for iron pipe complete all as specified.
S&F in repair swivel shower with shower arm PTMT 15mm size of any colour complete all as specified and directed by Engr-in-charge.
S&F sinks made of stainless steel1mm thick for kitchen or laboratory with plugs,waste pipe, washers and waste including cast iron cantilever brackets connecting union etc over all size 495mm x 420mm with bowl size 410mm x 330mm x160 mm complete all as specified and directed.
S&F vitreous china wash basin, white flat back size 550x400mm excluding taps, waste chain, waste pipe and plug and proclain stopper but including bracket complete all as specified and directed.
Supply & fixing 15mm bore wash basin mixer cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule complete, all as specified & directed by Engineer-in-charge.
Supply & fixing basin mixer cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge.
S&F brass chromium plated tubular towel rail 20mm dia, D type 60cm long between flanges complete.
S & F in repairs; stainless steel plate rack made out of 1mm thick steel sheet of size 75cm x 90cm x 25cm with fixing arrangements complete as per sample kept in GE’s office suitable for officers quarters complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per Sl item No 81 above but 75 mm dia
S & F PVC (SWR) bends for 110 mm dia PVC pipes
S&F PVC(SWR) bends for 75 mm dia PVC pipes with access door.
S&F PVC(SWR) bends for110 mm dia PVC pipes with access door
S&F PVC (SWR) vent cowl for110 mm dia PVC pipes complete all as specified and directed.
M&L for 75mm dia cast iron floor trap with CP grating including jointing to waste pipe with run lead joint and embedded in cement concrete (1:2:4) type B-1 using graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C2 as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L for 25mm thick PCC type B-0 (using 12.5mm graded stone aggregates) as in floors/sub base etc and finishing the surface rough and even to receive top layer as under tiles, stone etc complete all as specified.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specfied and directed.
M&L for 60mm thick rubber moulded interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-35 Grade as approved by Engr-in-Charge, laid in flooring and joints filled/broomed with fine sand complete all as specified and directed.
M&L for 80mm thick rubber moulded interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-40 Grade as approved by Engr-in-Charge, laid in flooring and joints filled/broomed with fine sand complete all as specified and directed.
S&F Mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, Tee, angle channel or flat sections) including distance pieces, cleats etc.(Fe-410-W(Gde E-250)Quality-A)
S&F rolled Mild steel work as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and like including caps bases, splices etc built up from two or more beam or channel sections or angles with plates or pipe section including all lattice bars, stiffeners, gusset plates etc..(Fe-410-W(Gde E-250)Quality-A)
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F in repair curtain rod made out of 25mm dia(outer dia) pipe having thickness 0.63mm , PVC coated and colour/pattern, over all dia 28 to 29 mm complete all as specified and directed, Make :- Aerolux/MEC/Vista.
S&F plastic finial of 28 to 29mm bore, decorated type, of any colour/pattern, best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive complete all as specified and directed, Make:- Aerolux/MEC/VISTA
S&F mild steel prepainted bracket to hold the curtain rod and fixed to wall(Concrete/brick masonry) with the help of 2 Nos 50mm long steel screws and rawl plug included drilling with electric drill and making good the disturbed surfaces complete all as specified and directed.
Dismantling brick tiles or terracing tiles sinlge layer on roofs.
Roughening surface of old concrete roof surfaces by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and as directed
M & L for 40mm thick (Avg thickness) PCC padding be provided in slope in PCC 1:2:4 type B-1 ( using 20mm graded aggregate) finishing the surfaces fair and even without using extra cement complete all as specified and directed.
M&L for screeding 10mm thick in cm 1:4 mixed with water proofing compound as per manufacturers instructions over green concrete surfaces of PCC padding complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately as supply only.
Supply only integral waterproofing compound .
M&L for preparation of roof top surfaces, providing and applying UV stable single component Smart Care Damp Proof Ultra is a fibre reinforced elastomeric liquid applied water proofing membrane formulated with PU hybrid polymers and reinforcing acrylics fibres and having Sun Reflectivity Index (SRI) of 106 on top of conrete roof surfaces in three coat including self primar at ratio of damp proof ultra and water 3:1 and covrage @ 1 Ltr /1.00 Sqm with a thickness of 650 micron, the vital physical and chemical parameters shall be as under : Min Elongation at breck of 350%, Resists positive hydrostatic pressure of upto 10 bars, crack bridging ability of 2.5 mm at 650 microns. The material shall be applied with brush or roller, complete in all respect as per the direction of Engineer in Charge/Consultant. (Note : 6 Hrs interval between two coat will be maintain & the work will be carried out through Company applicator duly got approved from Accepting Officer in writing before incorporation) and will be Paid only after receiving of the warrenty certificate from the Company. Make : Asian paint or equivalent as approved by GE.
Preparation of new wood surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
Preparation of new steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&Lfor preparation of new plastered surfaces of walls, applying a layer of wall care putty, one coat of primer and applying two coat of distemper oil emulsion completel all as specified and directed
M&Lfor prepration of new plastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed
M&Lfor plastering 5mm thick in cement mortar (1:3) finished even & smooth without using extra cement as on ceiling complete all as specified.
M&L for prepration of new plastered surfaces of ceiling and applying three coat of white wash complete all as specified.
M&L for complete removal of existing treatment, preparation of plastered surfaces of walls, applying a layer of wall care putty and two coat of distemper oil emulsion complete all as specified and directed
M&L for complete removal of existing treatment, prepration of plastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed
M&L for complete removal of existing treatment, prepration of plastered surfaces of wall and applying three coat of white wash complete all as specified.
M&L for precast PCC (1;2:4) type B-1 using 20mm graded stone aggregete as in kerbs of paths set in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
M&L for pre cast cement concrete cover in RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in cover slab for manhole and similar article with plain face, set in cement mortar 1:4 complete all as specified and direceted.
Taking down carefully copper/aluminum point wiring of any type such as concealed/surface / batten/ casing and capping (light, fan, socket or power) complete including fitting such as switches, bell push, ceiling roses, pendants, lamp/ bracket holders, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc.
M & L for concealed Point wiring for light points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit/ERW conduit not less than 19/20 mm dia with all fittings shunk in MS Pressed steel terminal boxessuitable depth and 1.6mm thick (duly painted with two coat of anticorrosive paint outsite and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified. Note : Quoted rates are inclusive of cutting chases and making good disturbed surfaces to match with the existing surfaces.
All as per item No.117 here-in before but one ceilling / exhaust fan/ventilating fan point controlled by one 5 Amps one way switch and regulator
All as per item No.117 here-in before but one 5 pin 6 Amps switch socket outlet point on same board..
All as per item No.117 here-in before but One 5 pin 6 Amp switch socket outlet point on independent board.
All as per item No.117 here-in before but for call bell point controlled by one switch
All as per item No.117 here-in before but 4.00 Sqmm copper wiring with 2.50Sqmm copper conductor as earth continuity for 15/16 Amps socket out let on independent board
S&F switch piano type one way 5 amps 240 volts complete.
S&F bell push flush type 5 amps 240 volts complete.
S&F socket outlet 5 pin 5 Amps flush type complete.
S&F switch piano flush button single pole one way 15 amps 240 volts complete.
S&F socket out let 2 in 1, 6 pin, 5 and 15 amps multi purpose flush type, 230 volts.
S&F electronic fan regulator step, 250V flush type on the exiting phenolic laminated sheet etc.
S&F ceiling rose surface bakelite 3 terminals.
S&F lamp holder PVC/ Polycarbonate insulated body with back plate for angle/batten fittings complete.
S&F retrofit LED lamp 9 watt light complete
S&F in reparis LED light fitting, 20 W, 4 ft long 230V, Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired including connecting up with twin core twisted flexible copper conductor cable complete all as specified.
Supply and fixing LED Mirror light fitting 2 Feet long 10 Watt LED Batten light for mirror and as wall light application complete
Supply and fixing of building security light fitting 70 W LED New generation Energy Saving & Environment friendly long life versatile pressure die-cast aluminium IP-66 roadwayluminars with high power LEDs as light source and electronic drive including connecting complete.
S&F LED type security/Street Light fitting 72 watt with LED lamps, pressure die cast housing with toughned glass cover,suitable gasket and IP 65 protection including all other standard accessories as per manufactures instruction and including fixed on poles/walls with clamps, nuts,bolts &washers including connecting to fitting including taking down old light fitting any type complete all as specified and directed.
Supply and fix security light mounting bracket, GI pipe 40mm dia medium grade for mounting bracket bent to shape 1.50 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as directed.
M&L for Sub main wiring with PVC insulated cable of size 2 X 6.0 Sqmm + 1 X 4.0 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc.
M&L for Sub main wiring with PVC insulated cable of size 2 X 4.0 Sqmm + 1 X 4.0 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc.
Supply, laying and connecting, LT UG cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 50 sqmm 3.5 core complete all as specified and directed.
Supply, laying and connecting, LT UG cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 35 sqmm 3.5 core complete all as specified and directed.
Supply, laying and connecting, LT UG cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 10 sqmm 2 core complete all as specified and directed.
Twin core 6 Sqmm size cable flat or circular, 1100V grade heavy duty cable, PVC insulated aluminium conductor served with inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 Mtr apart including 4mm dia galvanised iron wire as in replacement complete as directed
Twin core 10 Sqmm size cable flat or circular, 1100V grade heavy duty cable, PVC insulated aluminium conductor served with inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 Mtr apart including 4mm dia galvanised iron wire as in replacement complete as directed
Boring under road/path/hard standing to pass the HT / LT UG cables upto 80mm dia pipe with the own arrangement of T&P complete all as specified and directed.
Two runs of single core, PVC insulated 2.5 Sqmm cables with copper conductor alongwith one run of 1.5 Sqmm copper cable as earth conductor as in repairs complete all as specified and directed.
M & L for surface point wiring for Light point or 5 pin socket outlet 5 Amp on independent board points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit not less than 19/20 mm dia/PVC casing & caping with PVC gang box with all fittings shunk in MS Pressed steel terminal boxes suitable depth and 1.6mm thick (duly painted with two coat of anticorrosive paint outsite and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified.
All as per item No.146 here-in before but 4.00 Sqmm copper wiring with 2.50Sqmm copper conductor as earth continuity for 15/16 Amps socket out let on independent board
M&L for flame proof point wiring for light/fan point including ERW conduit with two single core cable (FRLS) PVC insulated unsheathed 1100 volt grade copper conductor multi standred of size 1.5 Sqmm and including of one run earth wire single core cable (FRLS) PVC insulated unsheathed 1100 volt grade copper conductor multi standred of size of 1.5 Sqmm to be drawn in 25mm dia ERW stove enamelled black rigid conduit with all flame proof conduit accessories such as tee, bend elbow, conduit junction box complete all as specified and directed. Note : ERW conduit, conduit accessories, circuit wires and earth wires complete shall be treated as one unit.
S&F flame proof flexible metalic hose conduit of size 3/4" dia and 300mm long suitable for explosive atmosphere with explosive dust proof complete all as specified and directed.
S&F flame proof/weather proof direct entry type rotary switch single pole ON & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 16/10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc duly tested & certified by CMRI-Dhanbad.
S&F flame proof exhaust fan single phase of size 18", 0.5HP copper winded moter including all accessories and fixing arrangement, testing and commissioning complete all as specified and directed.
Supply and fix 'B' series MCB SPN 40 amps, 240 volts, 50Hz.
Supply and fix 'B' series MCB SP 6 to 32 amps, 240 volts, 50Hz.
S&F PVC 15 Amp 2 way gang box fixed on wall or surface complete all as specified and directed by Engr-in-Charge.
Supply and fix door bell, Ding Dong AC, 230 volts, single pole
Supply and fixing Loadline Vertical TPN DB prewired distribution board double door, 4 way TPN-DPX 12-63, one No MCCB 100 Amps as incomer and four Nos of MCB TPN 40 Amp for outgoing, double door type sheet metal enclosure 415V with 63 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable complete all as specified and as directed.
Supply and fix sheet metal enclosure MCB SPN distribution board, 8 way, Double door with IP-43 protection single phase 240 volts, including suitable size copper bus bar and neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match with existing specification.
All as per item No.157 but MCB DB, 12 Way.
M&L for making holes for exhaust fans of size upto 450mm sweep by cutting brick walls to form hollow circle for fixing exhaust fan, plastering in cement mortar 1:4 and applying finishes to match with existing surfaces complete all as specifed and directed by Engr-in-Charge.
Taking down carefully existing water heaters of any capacity for depositing to MES store yard and again collection from MES store yard and re-hanging the same after re-wiring work complete all as specified and directed.
S&F in repairs PVC connection 450 mm long, 15mm size heavy duty for hot water connection to storage type water heaters complete all as specified.
S&F of MS sheet 1.00mm thick louver shutters for exhaust fans of size 350mm to 450mm sweep with all accessories and fixing on wall complete all as specfied and directed by Engr-in-Charge.
M&L for brick protection with sub class "B" bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable complete all as specified and directed specified .
Material & labour for sand cushioning in trenches and well ramming in layers with 8 cm below and 15 cm above the cable with fine dry sand for cable protection and complete all as specified and directed.
S&F in replacement 40mm bore GI tubing light grade as in cable protection pipe including all fittings complete all as directed
S&F 15mm bore UPVC water pipe, high density grade with all fittings fixed to walls or surface and including cuttings, connections with existing pipe line any size complete all as specified and directed.
S&F decogrill for aluminium windows complete all as specified and directed by Engr-in-Charge.
M&L earthing complete with galavanised steel plate electrode 600x600x6.00mm thick burried directly in ground vertically (earth pit to a depth of not less than2.25 meter deep below ground level) with the top adge of earth place at a depth of not less than 1.5 meter below normal ground level connected to GI strip 32x6mm by means of bolts, nuts, washers of galvanised iron and provision of earth wire, galvanised iron protection pipe 15mm bore, light grade up to and including test point including necessary earth work in any type of soild and PCC (1:3:6) type C1 (using 20mm graded stone aggregate) earth chamber, watering pipe 20mm dia galvanised iron light grade with funnel, RCC (1:2:4) type B1 precast cover 40mm thick with 6mm dia mild steel bars complete all as shown in electrical plate N.5 of SSR part-I connected to earthing test point all as specified or indicated,including taking down and testing on completion Note:- Quoted rate deemed to include the cost of excavation and earth work, PCC pit, funnel and cover etc,
M&L earthing complete with galavanised steel plate electrode 600x600x6.0mm thick burried directly in ground vertically (earth pit to a depth of not less than2.25 meter deep below ground level) with the top adge of earth place at a depth of not less than 1.5 meter below normal ground level connected to galvanised iron earth lead wire 4mm dia by means of bolts, nuts, washers of galvanised iron and provision of earth wire, galvanised iron protection pipe 15mm bore, light grade up to and including test point including necessary earth work in any type of soild and PCC (1:3:6) type C1 (using 20mm graded stone aggregate) earth chamber, watering pipe 20mm dia galvanised iron light grade with funnel, RCC (1:2:4) type B1 precast cover 40mm thick with 6mm dia mild steel bars complete all as shown in electrical plate N.5 of SSR part-I connected to earthing test point all as specified or indicated,including taking down and testing on completion Note:- Quoted rate deemed to include the cost of excavation and earth work, PCC pit, funnel and cover etc, Note for Sl item No 170 & 171 : - (a) Item of earthing includes cost of 20/40mm bore medium grade GI protection pipe and 7.50 metre long earth strip/lead upto test point. (b) On testing after completion of work, if desired earth resistance is not obtained earthing will be re-done by the contractor without any extra cost to the Govt.
CHOUDHARY ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .