Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.9 L+₹8,149 (0.29%)Rejected-Finance VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-Finance Rejected being not L1 | |
| 3 | L3₹29.2 L+₹1.4 L (4.96%)Rejected-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L3 | Rejected-Finance Rejected being not L1 | |
| 4 | L4₹32.7 L+₹4.9 L (17.5%)Rejected-Finance | L4 | Rejected-Finance Rejected being not L1 | |
| 5 | L5₹33.5 L+₹5.7 L (20.4%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MES) ROORKEE
Garrison Engineer Roorkee
REPAIR/MAINT AND REPLACEMENT OF OVERHEAD LINES, UNDER GROUND CABLE AND ALLIED WORKS IN AT ROORKEE AND PURKAZI UNDER GE ROORKEE
2023_MES_623335_1
8392/325/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ROORKEE
As per tender documents
8 documents required · 8 mandatory
₹500
GE (MES) ROORKEE
₹70,000
Yes
13 Jan 2024
14 Oct 2023
14 Nov 2023
14 Oct 2023
11 Nov 2023
28 Oct 2023
Amount
Supply & Fixing in replacement of existing PCC/Steel pole with new steel tubular poles complete with cast iron base plate, taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc complete all as specified and directed by Engr-in-charge. Note :- Excavation and PCC work will be measured and paid separately.
M&L for PCC work type D-2 (1:4:8) with 40mm graded stone aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.
M&L for PCC work type C-2 (1:3:6) with 40mm graded stone aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.
M & L for PCC work type B-1(1:2:4) with 20 mm graded stone aggregate for coping ( new and old damage coping) to poles / stays/strutus or basements etc complete all as specified and directed.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 80 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 32mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.
Supply, laying & testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area as given below:-
4 Core 10 Sqmm
4 Core 16 Sqmm
4 Core 25 Sqmm
4 Core 35 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 Core 120 Sqmm
Excavation in trenches/post holes in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed.
Supply and laying river sand for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. (Note: Thickness after punning (18cm) shall be measured for payment)
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge.
Labour only for stretching, tightening, fixing and connecting ACSR conductor and GI wire of existing HT/LT overhead line any size and type, between pope to pole, approximate span length 45 to 50 Mtrs complete as directed by Engineer-in-charge for the following number of conductors :-
2 Conductors with / without GI wire
5 Conductors with / without GI wire
6 Conductors with / without GI wire
Taking down unsv pin type insulator and providing new pin type, porcelain vitreous white brown or green insulator including one galvanized mild steel spindles, two galvanized iron washers and one galvanized iron nut 100mm height, 65 mm dia for 1100 Volt grade complete all as specified. Make BHEL/Pactil/Rastriya/Jaipuria.
M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed. Make Pactil/BHEL/Rastriya//Jaipuria.
Taking down U/S stay assy and M&L for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm long 20mm dia , MS/GI stay bow 40cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and directed by Engr-in-charge. Note : MS clamps will be measured & paid separately in respective items.
M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards, surrounding valve chamers Buildings and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed by Engr-in-charge.
Taking down rusted/unsv mild steel work and M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fixing in replacement of existing panel (Indoor/Outdoor) accessories including making in coming /out going electric connections complete all as specified and directed with suitable size of copper wire (Make - Legrand/Havells/C&S :-
MCCB rating 250 Amp FP, Breaking capacity 36 kA.
All as per item No 20.01 abovebut rating FP 200 Amp, 36 kA.
All as per item No 20.01 but rating FP 160 Amp, 36 kA.
All as per item No 20.01 but rating FP 125 Amp, 25 kA.
All as per item No 20.01 but rating FP 100 Amp , 25kA.
All as per item No 20.01 but rating FP 63 Amp , 16 kA.
All as per item No 20.01 but rating TP 100 Amp , 16kA.
MCCB Four pole 400 Amp, 36/35kA, Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts.
Digital Voltmeter of rating 0-500 V , size 96mm square type
Digital Ammeter of rating upto 0-600 Amp, size 96mm square type
LED Indicator assy with colour red/ yellow/ blue (Set of 3)
Current transformer (CT) Copper wound ratio 100/5 Amp (Set of 3 Nos).
All as per item No 20.13 above but ratio 200/5 Amp. (Set of 3 Nos).
Supply and fixing Onload Change over switch of capacity 400 A, 415 Vols, 50 Hz, confirming to IEC:60947-3, with rotating handle, including dismantling old unserviceable change over switch by disconnection all incoming and outgoing electrical connection from existing indoor LT Panel all as per Havells Cad No. IHNFO0400 or equivalent model in Legrand, Simens.
Supply and fixing Onload Change over switch of capacity 200 A, 415 Vols, 50 Hz, confirming to IEC:60947-3, with rotating handle, including dismantling old unserviceable change over switch by disconnection all incoming and outgoing electrical connection from existing indoor LT Panel all as per Havells Cad No. IHNFO0200 or equivalent model in Legrand, Simens.
Supply and fixing for in replacement of LT 1100 volt Line rigid PVC spacers type 4 lines complete all as specified and directed by Engr-in-charge. Make : Rashtriya/Jaipuria Bros.
All as per Item No- 23 above but 3 Line.
All as per Item No- 23 above but 2 Line.
M&L earthing including testing on completioncomplete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber (chamber size not less than 300x300x300mm interier diamentions), 50 mm thick cover RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and 50x50x5 ISA MS frame etc, complete all as specified. NOTE: (i) The unit rate includes earth strip and new GI protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. (ii) If test result are not satisfactory, the entire earthing shall be re done without any extra cost.
All as per Item No-26 above but Copper electrode 600mmx600mmx3mm thick and copper strip 25mmx3mm thick Note - If test result are not satisfactory, the entire earthing shall be re done without any extra cost.
M&L in replacement of unserviceable Bus-bar chamber made out of sheet metal enclosure 200 Amps power coated independent for five connections, copper busbar suitable for 200 amps current rating mounted on wall, including disconnecting all incoming and out going electrical connections complete all as specified and directed by Engr-in-Charge. Make: : HAvells Cat No. IHBC020006 or equivalent in Legrand/Simens/C&S/ABB
S & F in replacement of unserviceable TPN DB-VTPN for independent mounting fixed on wall duly flush mounted, 4 way, IP 43, IK 09 with 250 Amp Bus bar. Make : Legrand / C&S/L&T
S & F in replacement of u/s MCB TP 63 Amp, 415 Volt, 'c' curve including necessary connection complete all as specified and directed by Engr-in-charge. Make : Legrand / C&S/L&T
S & F in replacement of u/s MCB SP 6 to 32 Amp, 415 Volt,'c' curve including necessary connection complete all as specified and directed by Engr-in-charge. Make : Legrand / C&S/L&T
Material and labour for preparation of old painted surfaces using polish and painting two coats of aluminium paint on exposed surfaces to steel tubular pole of 11 mtr including crossarms, Bracket etc including 3 Nos. of strip / bands painted with postoffice red and nevy blue colour (300 mm each) in alternate layer from coping, marking of pole number with black synthetic enamel paint 2.5 cm height including in 3" dia circle complete all as directed by Engineer-in-Charge.
All as per item No 32 above but LT Pole upto 9 mtr.
Supply & fix PVC Junction box of size 255x355x122 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity including making suitable hole on existing pole to take out connections to fitting if required at site complete including provn of cable glands for incoming and outgoing cables all as specified. Make : Syntex/Hensel/Napture
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed.
M&L for overhauling to outdoor type LT panel/feeder pillar box of any size/ make including insulating to bus bars with shrinkable PVC sleeves of colours red, yellow, blue and black replacement of worn out / us cables as per existing gauge, door rubber beedings, nuts, bolts washers, hinges, thimbles, lugs, cable glands & welding work etc making functional to the system and testing on load complete all as specified and as directed at site by Engr-in-charge.Note:- Spares required for replacement will be measured & paid separately under respective items.
All as per Srl item No. 36 above but indoor type LT Panel/ feeder box.
M&L for painting to indoor/outdoor type LT panel/FP box of size not more than 1.8 m height internally as well as external surfaces complete with two coats of synthetic enameled paint of approved quality including preparation of old surfaces, writing of bus bars & outgoing /incoming locations with white paint grith upto 2” (50mm) complete all as specified & as directed at site by Engr-in-charge.
M&L for feeder pillar bus bar box of size of size 600x450x550mm of outdoor type, double door, both side openable, locking arrangement, kiosk type, powder coated, 3.15mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 400 Amp duly colour coded mounted on porcelain insulator, with provn of 06 Nos outgoings including MCCB 200 Amps, 4 pole, 36 kA,= 01 No, LED indicator (RYB), 08 Nos, holes in bottom for inlet and outlet cable with suitable size of cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 mm X 50 mm X 6 mm, 1.05 metre high (450mm below ground level and 600mm above ground) along with necessary excavation earth work 1:2:4 plain cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed by Engineer-in-Charge. Note : (a) Feeder pillar box shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only and depth of panel not less than 55CM. (b) Electric connection between MCCB and Busbar shall be with aluminium strip links duly colour coded. (c) MCCB shall be of make-Havells/Legrand/ABB/C&S
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm SDR-21 of 4kgf/cmsq with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified.
M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of required dia and necessary machine suitable for 0.4 mpa working pressure. Note :- GI pipe medium / Light grade will be measeured and paid saperately under respective item.
Repairing/ Maint of LT over head lines and routine maintenance of electric supply/ current leakage / Under ground LT cables, clearance of vegitation growth over and around of LT OH lines, Repair / Maintenance of LT feeder piller boxes, incl MCCBs / Timer switch, protection devices. electrical accessories in day to day maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected major accessories. Work shall also include to check & removal of Vegitetion etc .
Note for item No 42.00 :- (a) Contractors representative incl 01 x Electrician and 01x Mazdoor will report to Engr-in-charge/ JE E/M (Ext Elect) daily at forenoon and afternoon to collect routine/urgent works related to Ext Elecctric supply till completion of contract. The work shall be attended by the contractor immediately. (b) The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, Jumpers , insulators , nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requiste T&P and Mobile phone to his trades man. (c) All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 24hrs after handing over of routine/urgent works, the contractor shall be liable to pay the penalty of Rs. 1000/- per day. (d) The contractor shall maintain one bound register for noting complaints with date and time, obtaining user signature after completion of complaint, counter signed by JE in charge and shall be submitted at the time of RAR payment for counting days. If no complaints /Sundays/Holidays will be excluded for payment.
Supply & Fix in replacement LED bulb 45/50 watts suitable for B-22/E-27 type base, 5700K as per Syska Cat No. SSK-RB-4501 B22 & E27 BULB, Havells Cat No-LED FLORIDA ULTRA 50W , Philips Cat No-Tforce Core 47W/5000lmB22
Supply & Fix in replacement Lamp holder,B-22 base with LED bulb 30/40 watts suitable for B-22/E27 type base, 5700K, fxed on post-top lantern fittings complete all as specified and directed.as per Syska Cat No. SSK-HPB-40W, Havells Cat No-LED FLORIDA ULTRA 30W, Philips Cat No-Tforce Core 47W/4000lmE27
Taking down carefully old unserviceable security light fittings from pole and S & F in replacment of security light fittings LED 25 watt with secondary lens luminaries IP 66, 5700K, with inbuilt surg driver complete with all accessories as directed by Engineer-in-Charge. Make :Syska Cat part No. SSK-SLF-CF-25W-WL, OR Havells Cat No-ENDURAPEARLSL25WLED757SASYTOPCMP OR Crompton Cat No. TRP-400-25-57-SL-LM-NSR.
Taking down carefully old unserviceable security light fittings from pole and S & F in replacment of security light fittings LED 45 watt with secondary lens luminaries IP 66, 5700K, with inbuilt surg driver complete with all accessories as directed by Engineer-in-Charge. Make : Syska Cat part No. SSK-SLF-CF-45W-WL, OR Havells cat No-ENDURAPEARLNEOSL45WLED757PASYTOPC or Crompton Cat No. TRP-409-45-57-SL-NS-GL-NSG.
Taking down carefully old unserviceable security light fittings and S & F in replacement of security light fittings suitable for LED 60 watt with lens complete with all accessories as directed by Engineer-in-Charge. Syska Cat part No. SSK-SLF-CF-60W-WL, OR ENDURAPEARLNEOSL60WLED757PASYTOPC or Crompton Cat No. TRP-409-60-57-SL-GL-NSG.
Taking down carefully old unserviceable security light fittings and S & F in replacement of security light fittings suitable for LED 90 watt with lens complete with all accessories as directed by Engineer-in-Charge. Syska Cat part No. SSK-SLF-CF-90W-WL, OR Havells Cat No-ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or Crompton Cat No. TRP-411-90-57-SL-GL-NSG.
Taking down carefully old unserviceable light fittings and S & F in replacement of Flood light fittings suitable for LED 120 watt IP 66 with lens complete with all accessories as directed by Engineer-in-Charge. Syska Cat part No. SSK-FLN-120W, and Havells Cat No-JETAIRISFLS 120WLED757APWBLT G OR Crompton Cat No- LFLN-120-WW/60-M.
Taking down carefully old unserviceable light fittings and S & F in replacement of Flood light fittings suitable for LED 200 watt IP 66 with lens complete with all accessories as directed by Engineer-in-Charge. Syska cat part No.SSK-FLN-200W and Bajaj Cat No. BJFL 200W LED I or Crompton Cat No- LFLN-200-WW/60-M
S & F in replacement of old unserviceable LED Highbay light fitting 100 watt capacity with PDC aluminium with reflactor including making electrical connection from ceiling rose to light fitting complete all as per Syska cat No. SSK-HBG-100W, Havells SAUCERGENXPROHBP100WLED757P60DBOLT G, Crompto Cat . LHB11-100-CDL/60-HPM. Note for Item No- 46 to 52 :- (i) The Quoted rate is deemed to be included for installation of light fitting at any height (including High mast, Tower lights, Indoor sports complex etc.) including necessary T & P and safety equipments. (ii) All LED fitting shall be guaranted for 5 years and 2.5% of cost will be retension as guarantee money
M & L in replacement for bracket made out of GI tubing 40 mm dia, light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia with -4 Nos & flat washer (3mm thick) 01 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.
Supply and fixing PVC insulated cable three core 1.5 Sqmm PVC Insulated with multi stranded copper conductor for making connection from junction box to light fitting complete with suitable size copper lugs.
Supply and fixing PVC insulated cable three core 2.5 Sqmm PVC Insulated with multi stranded Copper conductor for making connection from junction box to light fitting complete with suitable size copper lugs.
Supply only PVC electric cable with insulated aluminium conductor (stranded) with inner sheathing of PVC tape and overall PVC sheathed 1100 volts grade, heavy duty, 10 sqmm twin core, weather proof flat with accessories, complete all as specified and directed.
All as per Item No 56 above but of size 2 core 16 Sqmm.
All as per Item No 56 above but of size 2 core 06 Sqmm.
AMAR NATH SHARMA
KAPOOR ELECTRICALS
M/S ROORKEE ENGINEERING
Shikha Enterprises
Pradeep Bros
KRISHANA ELECTRIC WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .