Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | ₹44.0 L Quoted ₹44.4 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹46.4 LRejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹46.4 L | L2 | Rejected-Finance Not being lowest bidder |
| 3 | L3₹46.8 LRejected-Finance | ₹46.8 L | L3 | Rejected-Finance Not being lowest bidder |
| 4 | L4₹47.8 LRejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | ₹47.8 L | L4 | Rejected-Finance Not being lowest bidder |
| 5 | L5₹48.3 LRejected-Finance 05 PASCHIMSAGAR DIGLIPUR PASCHIMSAGAR NORTH AND MIDDLE ANDAMAN ANDAMAN NICOBAR 744202 | NORTH AND MIDDLE ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | ₹48.3 L | L5 | Rejected-Finance Not being lowest bidder |
| Sl No | Description | Qty | Unit | Anil Kumar Sarmah L2 | M/S HARJINDER SINGH L3 | M/s R S ENTERPRISE L5 | M/S Manjit Singh L1 | M/S SEWAK SINGH L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Air Conditioner
M&L for taking out u/s air conditioner window/ split type in capacity 1.5 TR and 2 TR for replacing to u/s spare parts / carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any make /model all as site with connecting accessories from existing location after removing of all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all specified and as directed.
Note :- (i) Connecting accessories will be taken in safe custody by contractor for re-using at same. (ii) All spare parts shall be measured and paid separately under relevant items. | 20 | Each Job | 300 ₹6,000 | 444 ₹8,880 | 350 ₹7,000 | 200 ₹4,000 | 800 ₹16,000 |
| 2.00 | Supply and re- filling/ charging of refrigerant gas of R-134A,R-32, R-410A, R-22 in original to window or split type air conditioner upto 2 TR capacity with speicific pressure grade complete all as specified and as directed.
Note : Grade of refrigerant shall be supplied as per model /make requirement in original. | 120 | Kg | 1,100 ₹1.3 L | 999 ₹1.2 L | 1,200 ₹1.4 L | 1,090 ₹1.3 L | 1,200 ₹1.4 L |
| 3.00 | Supply only rotary DC compressor unit for invertor window type cap upto 1.5 TR 230 V, Single Phase as required in origional manufactures complete all as specified and directed. | 1 | Each | 1,000 ₹1,000 | 9,000 ₹9,000 | 1,000 ₹1,000 | 9,999 ₹9,999 | 20,000 ₹20,000 |
| 4.00 | All as per item No 03 above but rotary DC compressor unit for invertor split type cap upto 1.5 TR.230 V, Single Phase Complete all as specified and directed. | 7 | Each | 1,000 ₹7,000 | 9,000 ₹63,000 | 1,000 ₹7,000 | 9,000 ₹63,000 | 20,000 ₹1.4 L |
| 5.00 | All as per item No 3 above but reciprocating / rotary AC compressor unit for window type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed. | 1 | Each | 8,000 ₹8,000 | 15,000 ₹15,000 | 10,000 ₹10,000 | 10,025 ₹10,025 | 18,000 ₹18,000 |
| 6.00 | All as per item No 3 above but reciprocating / rotary AC compressor unit for split type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed. | 6 | Each | 12,000 ₹72,000 | 12,000 ₹72,000 | 15,000 ₹90,000 | 10,070 ₹60,420 | 18,000 ₹1.1 L |
| 7.00 | All as per item No 3 but above but Starting/Running Capatior for Existing model of split/ window AC complete all as specified and directed. | 40 | Each | 450 ₹18,000 | 1,000 ₹40,000 | 450 ₹18,000 | 700 ₹28,000 | 550 ₹22,000 |
| 8.00 | Flushing and leak testing of complete system with Nitrogen gas and topping up compressor oil complete all as specified and directed. | 12 | Job | 500 ₹6,000 | 300 ₹3,600 | 500 ₹6,000 | 551 ₹6,612 | 300 ₹3,600 |
| 9.00 | M&L for servicing,oiling, greasing, cleaning, dusting ,overhauling etc all as site requirement for air conditioner in all make/type/ model /cap upto 2 TR etc for making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting complete all as specified and directed. | 28 | Each Job | 900 ₹25,200 | 800 ₹22,400 | 700 ₹19,600 | 492 ₹13,776 | 1,400 ₹39,200 |
| 10.00 | Water cooler/ refiregator and Deep- freezer :-
Labour for taking out u/s water cooler/ refrigerator and deep- freezer of any make/ model/ capacity etc for replacing to u/s spares /servicing/ carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any type/ cap/ make /model all as site with connecting accessories from existing location after removing all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all as specified and directed.
Note :- (i) Connecting accessories will be taken in safy custody by contractor for re-using at same.
(ii) All spare shall be measured and paid against respective items . | 26 | Each Job | 700 ₹18,200 | 200 ₹5,200 | 200 ₹5,200 | 200 ₹5,200 | 500 ₹13,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Jan 2026, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali
REPAIR/REPLACEMENT OF WINDOW/SPLIT ACs/WATER COOLER, DEEP FREEZER, PACKAGE TYPE AC PLANT AND OTHER CONNECTED WORKS UNDER GE (S) TEZPUR
2025_MES_743859_1
9091
Open Tender
Civil Works
210 days
GE South Tezpur
as per NIT
4 documents required · 4 mandatory
₹500
GE South Tezpur
₹90,000
Yes
6 Feb 2026
9 Dec 2025
5 Jan 2026
9 Dec 2025
2 Jan 2026
26 Dec 2025
9 Dec 2025 - 17 Dec 2025
Amount
Air Conditioner M&L for taking out u/s air conditioner window/ split type in capacity 1.5 TR and 2 TR for replacing to u/s spare parts / carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any make /model all as site with connecting accessories from existing location after removing of all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all specified and as directed. Note :- (i) Connecting accessories will be taken in safe custody by contractor for re-using at same. (ii) All spare parts shall be measured and paid separately under relevant items.
Supply and re- filling/ charging of refrigerant gas of R-134A,R-32, R-410A, R-22 in original to window or split type air conditioner upto 2 TR capacity with speicific pressure grade complete all as specified and as directed. Note : Grade of refrigerant shall be supplied as per model /make requirement in original.
Supply only rotary DC compressor unit for invertor window type cap upto 1.5 TR 230 V, Single Phase as required in origional manufactures complete all as specified and directed.
All as per item No 03 above but rotary DC compressor unit for invertor split type cap upto 1.5 TR.230 V, Single Phase Complete all as specified and directed.
All as per item No 3 above but reciprocating / rotary AC compressor unit for window type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed.
All as per item No 3 above but reciprocating / rotary AC compressor unit for split type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed.
All as per item No 3 but above but Starting/Running Capatior for Existing model of split/ window AC complete all as specified and directed.
Flushing and leak testing of complete system with Nitrogen gas and topping up compressor oil complete all as specified and directed.
M&L for servicing,oiling, greasing, cleaning, dusting ,overhauling etc all as site requirement for air conditioner in all make/type/ model /cap upto 2 TR etc for making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting complete all as specified and directed.
Water cooler/ refiregator and Deep- freezer :- Labour for taking out u/s water cooler/ refrigerator and deep- freezer of any make/ model/ capacity etc for replacing to u/s spares /servicing/ carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any type/ cap/ make /model all as site with connecting accessories from existing location after removing all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all as specified and directed. Note :- (i) Connecting accessories will be taken in safy custody by contractor for re-using at same. (ii) All spare shall be measured and paid against respective items .
M&L for servicing,oiling, greasing, cleaning, dusting overhauling to water cooler/ refrigerator and deep- freezer in any make/ model/ capacity etc complete all as site requirement works for in all make/type/ model /cap etc for making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting all as same at site and directed.
Supply only in replacement of compressore unit for 40 to 80 ltr storage capacity suitable for refrigerator/ water cooler/deep- freezer in any capacity / make/ model/ type etc as site in origional manufactures complete all as specified and directed. Note :- (i) All spares shall be hold original manufacture tag with cat no. (ii) Spare will be suitable for all capacity and Make LG / Voltas/ Blue star/ Usha/ Vidiocon/ Usha/ Sumsang / Annapurna / whirlpool/ Gojrej/ Danfoss / Tecumseh etc as site.
All as per item No 12 but compressor unit for 80 to 150 ltr storage capacity complete all as specified and directed.
All as per item No 12 but compressor unit for 165 to 250 ltrs capacity complete all as specified and directed.
All as per item No 12 but compressor unit for 260 to 405 ltr capacity complete all as specified and directed.
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 10.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 10.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 10 Sqmm conductor as main wire and one run of 10 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
Taking down MCB & DB from existing location with connection of any size and any type complete all as specified and directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Tripple pole and neutral (TPN) 415 Volt , double door, suitable for 4 way with dim rail earth and neutral bar complete all as specified and directed.
S&F sheet metal enclosure for DB'S 12 Way when MCBs to be used single pole neutral 240 Volts with 200 A Bus Bar complete of following sizes complete all as specified and directed.
S&F sheet metal enclosure for DB'S 8 Way when MCBs to be used single pole neutral 240 Volts with 200 A Bus Bar complete of following sizes complete all as specified and directed.
Supply and fixing in proper position MCB TPN 63 AMP, capacity , C Curve 415 Volts with 10 kA breaking capacity complete all as specified and directed.
S&F MCB Single pole and neutral 240 Volt 20 to 40 Amp ,capacity C Curve complete all as specified and directed.
S&F MCB Single pole 240 Volt 6 to 32 Amp capacity C Curve complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including provision of fan hook complete all as specified and directed
M&L complete for pvc exhaust fan of size 250 mm sweep, single phase,230volts Ac with louver shutter /grill and connection complete incl cutting hole and making good disturbed surface and necessary fixing arrangements complete all as specified and directed.
M&L complete for metal body exhaust fan of size 300 mm sweep, single phase,230 volts Ac with louver shutter /grill and connection complete incl cutting hole and making good disturbed surface and necessary fixing arrangements complete all as specified and directed. .
Supply & Fix electric storage heater of 25 Ltr capacity, 5 Star in replacement with heating element 2000 W, thermostat, inlet, outlet connection pipe and air vent connections including all fixing arrangement for mounting on wall and necessary water inlet and outlet connections complete all as specified and directed.
Supply and fixing wall mounting hi-flow and heavy duty fan with all accessories of Size 400 mm sweep, 230 volt Ac with connection from existing celing rose all as specified and as directed
Supply and fix Chimney Faber 90 cm, 1500 cum/hr Auto- Clean curved glass kitchen Chimney including necessary fitting and cutting/hole in roof/wall suitable size complete all as specified and directed.
S&F metal clad socket out let with MCB single pole and nutral 20-32 Amp, 240 V including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed.
Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and all as directed.
M&L for 40 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and directed.
Supply and laying of well burnt bricks, sub class 'B' laid flat in trenches for protection of cable complete all as specified and directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm thick complete all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 95 Sqmm x 3.5 core complete all as specified and directed.
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 50 Sqmm x 3.5 core complete all as specified and directed.
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 25 Sqmm x 4.0 core complete all as specified and directed.
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 16Sqmm x 4.0 core complete all as specified and directed.
Supply and fixing and connecting in replacement of fully automatic single phase naturally air cooled indoor type wall mounting type digital voltage stabilizer voltage variation between 130 to 300 volts with output voltage stabilizer at 230 v with accuracy of +/- 2.5% of capacity 5 KVA (suitable up to 2 Ton or 24000 Btu/Hr) W TDR complete all as specified and directed.
Supply and fixing and connecting in replacement of fully automatic single phase naturally air cooled indoor type wall mounting type digital voltage stabilizer voltage variation between 130 to 300 volts with output voltage stabilizer at 230 v with accuracy of +/- 2.5% of capacity 4 KVA (suitable up to 1.5 Ton or 24000 Btu/Hr) W TDR complete all as specified and directed.
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
Anil Kumar Sarmah (BID ID -3510525)
M/S HARJINDER SINGH (BID ID -3513779)
M/S SEWAK SINGH (BID ID -3513804)
M/s R S ENTERPRISE (BID ID -3513181)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Addldocus.pdf
Additional Documents • 0.16 MB
BOQ_832917.xls
BOQ • 0.83 MB
Tenderdocus.pdf
Tender Documents • 1.29 MB
Download all tender documents and submit your bid