Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 CrAdmitted-Finance 1ST FLOOR PANCOM CHAMBERS 6 3 1090 1 A RAJ BHAVAN ROAD SOMAJIGUDA HYDERABAD 500082 | HYDERABAD | SOMAJIGUDA | TELANGANA | 500082 | L1 | Admitted-Finance | |
| 2 | Rejected-Technical | - | Rejected-Technical Technically ineligible | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically ineligible |
| Sl No | Description | Qty | Unit | PES Engineers Private Limited L1 |
|---|---|---|---|---|
| 1.00 | CHUTE SPILLWAY RADIAL GATE: Supply of Hydraulic Power Pack, Local Control Panel, Angle Transmitter (FSG/ rittmeyer) for Gate position indication with cables and accessories. | 3 | Sets | 77,74,290 ₹2,33,22,870 Lowest |
| 2.00 | MAIN SPILLWAY RADIAL GATE: Supply of Hydraulic Power Pack, Local Control Panel, Angle Transmitter for Gate position indication with cables and accessories. | 5 | Sets | 73,37,500 ₹3,66,87,500 Lowest |
| 3.00 | AUXILLARY SPILLWAY VERTICAL GATE: Supply of Hydraulic Power Pack, Local Control Panel, Angle Transmitter (MTS Temposonic/rittmeyer) for Gate position indication with cables and accessories | 1 | Set | 34,00,790 ₹34,00,790 Lowest |
| 4.00 | INTAKE GATE: Supply of Hydraulic Power Pack, Local Control Panel with cables and accessories | 2 | Sets | 42,75,500 ₹85,51,000 Lowest |
| 5.00 | SURGE SHAFT GATE: Supply of Hydraulic Power Pack, Local Control Panel with cables and accessories | 3 | Sets | 1,29,16,900 ₹3,87,50,700 Lowest |
| 6.00 | Supply of Low Vacuum Dehydration & Degasification Unit (LVDH) should be provided to remove water content present in the oil. This should be mobile unit which can be taken near to any HPU for operating | 1 | No. | 12,74,000 ₹12,74,000 Lowest |
| 7.00 | Supply of Electrostatic Liquid Cleaner (ELC) unit should be provided to remove solid suspended particles (up to 1 micron and below) present in the oil. It should works on the principle of electrostatics to collect the fluid contaminants. This should be mobile unit which can be taken near to any HPU for operating | 1 | No. | 10,01,000 ₹10,01,000 Lowest |
| 8.00 | Supply of Gasoline Engine Power Pack: Gasoline engine operated Power Pack should be provided to operate the hydraulic cylinders in case of power failure. This Power Pack should be able to operate the hydraulic Power Pack at least at half the normal working speed (operating speed 0.10 M / Min). The Power Pack should be portable trolley mounted which can be taken to any Power Pack for operating | 1 | No. | 21,84,000 ₹21,84,000 Lowest |
| 9.00 | Supply of ARMAC system with key features like water level monitoring, real time data processing, flexible programming, data logging, optimization of seasonal levels, etc. to control the above referred gates including all accessories (For further details, refer SBD) | 1 | Lot | 3,18,50,350 ₹3,18,50,350 Lowest |
| 10.00 | Supply of online silt monitoring system to be integrated into ARMAC system (For further details, refer SBD) | 1 | Lot | 57,33,000 ₹57,33,000 Lowest |
Tender Value
₹15.5 Cr
EMD Value
₹31.4 L
Closing Date
20 May 2026, 4:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division BHEP Chanderkote
Upgradation of Hydraulic system/ powerpack at all the Gates installed at Dam site and surge shaft emergency gate chamber at Power House BHEP-I, including ARMAC System at Dam
2026_SPDC_302399_1
E NIT NO. 21 OF 2025-26 DATED 05.02.2026
Open Tender
Machineries/ Mechanical Engg Items
Lump-sum
365 days
BHEP Chanderkote
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
CPAO BHEP Chanderkote
₹31.4 L
JKPDC Corporate Office Jammu
21 Aug 2026
5 Feb 2026
21 May 2026
5 Feb 2026
20 May 2026
14 Feb 2026
5 Feb 2026 - 20 May 2026
11 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | CHUTE SPILLWAY RADIAL GATE: Supply of Hydraulic Power Pack, Local Control Panel, Angle Transmitter (FSG/ rittmeyer) for Gate position indication with cables and accessories. | - | Sets | 100 | - |
| 2 | MAIN SPILLWAY RADIAL GATE: Supply of Hydraulic Power Pack, Local Control Panel, Angle Transmitter for Gate position indication with cables and accessories. | - | Sets | 100 | - |
| 3 | AUXILLARY SPILLWAY VERTICAL GATE: Supply of Hydraulic Power Pack, Local Control Panel, Angle Transmitter (MTS Temposonic/rittmeyer) for Gate position indication with cables and accessories | - | Set | 100 | - |
| 4 | INTAKE GATE: Supply of Hydraulic Power Pack, Local Control Panel with cables and accessories | - | Sets | 100 | - |
| 5 | SURGE SHAFT GATE: Supply of Hydraulic Power Pack, Local Control Panel with cables and accessories | - | Sets | 100 | - |
| 6 | Supply of Low Vacuum Dehydration & Degasification Unit (LVDH) should be provided to remove water content present in the oil. This should be mobile unit which can be taken near to any HPU for operating | - | No. | 100 | - |
| 7 | Supply of Electrostatic Liquid Cleaner (ELC) unit should be provided to remove solid suspended particles (up to 1 micron and below) present in the oil. It should works on the principle of electrostatics to collect the fluid contaminants. This should be mobile unit which can be taken near to any HPU for operating | - | No. | 100 | - |
| 8 | Supply of Gasoline Engine Power Pack: Gasoline engine operated Power Pack should be provided to operate the hydraulic cylinders in case of power failure. This Power Pack should be able to operate the hydraulic Power Pack at least at half the normal working speed (operating speed 0.10 M / Min). The Power Pack should be portable trolley mounted which can be taken to any Power Pack for operating | - | No. | 100 | - |
| 9 | Supply of ARMAC system with key features like water level monitoring, real time data processing, flexible programming, data logging, optimization of seasonal levels, etc. to control the above referred gates including all accessories (For further details, refer SBD) | - | Lot | 100 | - |
| 10 | Supply of online silt monitoring system to be integrated into ARMAC system (For further details, refer SBD) | - | Lot | 100 | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.65 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.89 MB
SBD.pdf
Tender Documents • 0.88 MB
BOQ_981330.xls
BOQ • 0.33 MB
ExtCorrigendum05052026.pdf
PDF • 1.27 MB
extCORRIGENDUM210426.pdf
PDF • 0.22 MB
GeneralExtCorrigendumm.pdf
PDF • 3.51 MB
Corrigendum05.pdf
PDF • 0.25 MB
TenderCorrigendum04_ARMAC.pdf
PDF • 1.31 MB
ARMACextension.pdf
PDF • 1.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .