Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹20.0 L
EMD Value
₹40,000
Closing Date
29 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DC Elect
FTR HQ BSF M and C
Replacement of essential non essential panel in generator room at 170 BN BSF Dholchera under SHQ BSF Silchar
2025_BSF_890775_1
11/NIT/Engg/FTR M n C/EE Elect/2025 26
Open Tender
Electrical Works
Percentage
120 days
BSF Campus 170 BN BSF Dholchera
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹40,000
8 Jan 2026
20 Dec 2025
30 Dec 2025
20 Dec 2025
29 Dec 2025
20 Dec 2025
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3½ X 95 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3½ X 150 sq. mm (50mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3½ X 240 sq. mm (62mm)
SITC of indoor type compartmentalized cubical panel of size suitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 1000A/415V 4 strip aluminum bus bar duly PVC sleeved, including connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space for 630A 4 Pole Air Circuit Breakers, for one transformer, MCCBs. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and includingprovision of outgoing cable connections bus bar links of required current carrying capacityetc as required. (Indoor Panel should be as per design & drawing approved by Engg in charge and comprising of) Instruments Panel S/Stn No-01:- a) Multifaction meter 01 set b) LED Pilot light (22.5 MM dia) with protection MCB’s-02Nos) 900mm depth
SITC of indoor type compartmentalized cubical panel of size suitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet and depth 600 mm with required hardware duly painted with powder coated. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 400 A/415V 4 strip aluminum bus bar duly PVC sleeved,, connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space for varius MCCBs changeover etc. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and including provision of outgoing cable connections bus bar links of required current carrying capacityetc as required. (Indoor Panel should be as per design & drawing approved by Engg in charge and comprising of) Instruments Panel S/Stn No-01:- a) Multifaction meter b) LED Pilot light (22.5 MM dia) with protection MCB’s-02Nos) Depth of panel 600 MM
Providing and fixing 400 Amp 36 KA MCCB with thermo magnetic release cat no LV540309 with Rotary handle and spreader links Schneider accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge.
Providing and fixing 250 Amp 36 KA MCCB with thermo magnetic release cat no LV525343 with Rotary handle and spreader links Schneider accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge.
Providing and fixing 125 Amp 25 KA MCCB with thermo magnetic release cat no LV516312 with Rotary handle and spreader links Schneider accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge.
Providing and fixing 63 Amp 25 KA MCCB with thermo magnetic release cat no LV510315 with Rotary handle and spreader links Schneider accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge.
Providing and fixing of 125 Amp, 415 Volt 50 Hz change over switch in existing feeder pillar including drilling holes in cubicle panel, making connections, etc. as required
Providing and fixing of 250 Amp, 415 Volt 50 Hz change over switch in existing feeder pillar including drilling holes in cubicle panel, making connections, etc. as required.
Providing and fixing of tape wound current transformer 1000/5 in the existing panel i/c connections with 1.5 sqmm pvc copper wire AE/L&T/Scheinder in the existing panel .
Providing and laying of 3.5 x 50 sq. mm XLPE insulated and PVC sheathed armored cable aluminium conductor 1.1 KV grade conf. to IS : 7098( Part 1)/ 1998 Havells/ Grandlay/ Polycab/ Gloster make in 90 mm dia (OD-90 mm & ID-76 mm nominal)DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Providing and laying of 3.5 x 240 sq. mm XLPE insulated and PVC sheathed armored cable aluminium conductor 1.1 KV grade conf. to IS : 7098( Part 1)/ 1998 Havells/ Grandlay/ Polycab/ Gloster make direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering Above 185 sq. mm and upto 400 sq. mm
Add GST 18% instead of 12% (MF= 0.0633 )
stage.html
html • 0.02 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.48 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_936285.xls
BOQ • 0.31 MB
NITdholchera.pdf
Tender Documents • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .