Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹6.1 L+₹8,339.98 (1.39%)Accepted-Finance | L2 | Accepted-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹11,914
Closing Date
8 Oct 2026, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE (ELECT.)
SHQ BSF PSR
Improvement of existing panel switchgear at BOP Kulidor BOP Kutterbasa and BOP Ranibari of 97 Bn BSF under SHQ BSF Panisagar
2026_BSF_927832_1
94/SHQ(/PSR/AE(E)/NIT/2026-27
Open Tender
Electrical Works
Percentage
90 days
97 BN BSF
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹11,914
15 Oct 2026
26 Sept 2026
9 Oct 2026
26 Sept 2026
8 Oct 2026
26 Sept 2026
30 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. | 2 | Set | 7,658 | ₹15,316 |
| 2 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I pipe from earth electrode including connection with G.I thimble excavation and re-filling as required. | 5 | Mtrs | 313 | ₹1,565 |
| 3 | Supplying & laying of one number PVC insulated and PVC sheathed Armoured / XLPE power cable of 1.1 KV grade of size 3.5 x 70 sqmm, direct in ground in the trench in one tier horizontal formation including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering Conf. to IS:7098 part - I (make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T) | 20 | Mtrs | 1,529 | ₹30,580 |
| 4 | Supplying & laying of one number PVC insulated and PVC sheathed Armoured / XLPE power cable of 1.1 KV grade of size 3.5 x 25 sqmm, direct in ground in the trench in one tier horizontal formation including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering Conf. to IS:7098 part - I (make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T) | 340 | Mtrs | 775 | ₹2,63,500 |
| 5 | Supplying & laying of one number XLPE insulated and PVC sheathed Armoured power cable of 1.1 KV grade of size 3.5 x 70 sq mm in the existing RCC/ HUME/ METAL pipe/surface as required Conf. to IS:7098 part - I of ( make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T) | 10 | Mtrs | 1,371 | ₹13,710 |
| 6 | Supplying & laying of one number XLPE insulated and PVC sheathed Armoured power cable of 1.1 KV grade of size 3.5 x 25 sq mm in the existing RCC/ HUME/ METAL pipe/surface as required Conf. to IS:7098 part - I of ( make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T) | 45 | Mtrs | 618 | ₹27,810 |
| 7 | Supplying & laying of G.I. pipe of 40 mm dia (medium duty ) G.I pipe in floor/wall/road for protection of UG cable including cutting the wall/floor/metalled road and making good the same as required. Make Jindal/ TATA/ Bansal/ Hindustan/equivalent. | 6 | Mtrs | 452 | ₹2,712 |
| 8 | SITC of outdoor type feeder piller, double door made out of 16 SWG CRCA sheet of size not less then 1200 mm x 1000 mm x 350 mm deep having 200 amps, 04 nos insulated aluminium bus bars, suitable size of angle iron frame with 04 nos 600 mm long legs and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required.
(i) 100 Amps, 4 pole, 415 volts, 25 kA, 50 Hz MCCB make L&T/Havells/C&S/HPL/equivalent - 2 Nos
(ii) 100 Amps, 4 pole, 415 volts, 50 Hz changeover make L&T/Havells/C&S/HPL/equivalent -01 Nos
(iii) 63 Amp, 4 pole, MCCB, 10 kA, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 02 Nos
(iv) 63 Amp, Double pole, MCB, 10 KA, C curve, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 06 Nos
(v) Cu wire lead a) 16 sq mm.
(vi) Thimble suitable size
(vii) Phase indicator LED Lamp (R,Y,B) -03 Nos | 1 | Each | 1,41,320 | ₹1,41,320 |
| 9 | SITC of outdoor type feeder piller, double door made out of 16 SWG CRCA sheet of size not less then 1000 mm x 900 mm x 350 mm deep, having 200 amps, 04 nos insulated aluminium bus bars, suitable size of angle iron frame with 04 nos 400 mm long legs and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required.
(i) 100 Amps, 4 pole, 415 volts, 50 Hz MCCB make L&T/Havells/C&S/HPL/equivalent -01 Nos
(ii) 63 Amp, 4 pole, MCCB, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 02 Nos (iii) 63 Amp, Double pole, MCB, c curve, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 06 Nos
(iv) Cu wire lead a) 16 sq mm.
(v) Thimble suitable size
(vi) Phase indicator LED Lamp (R,Y,B) -03 Nos | 1 | Each | 99,200 | ₹99,200 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
94bopranibariandkulidore97bn.pdf
Tender Documents • 0.95 MB
BOQ_975032.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .