| 1 | L1₹5.9 LAccepted-AOC VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹6.3 L+₹15,044 (2.45%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹6.8 L+₹62,545 (10.2%)Rejected-Finance | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹6.8 L+₹67,565 (11.0%)Rejected-Finance | L4 | Rejected-Finance not being L1 | |
| 5 | L5₹6.9 L+₹75,805 (12.4%)Rejected-Finance | L5 | Rejected-Finance not being L1 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
23 Jan 2020, 6:00 pmClosed
AGE (I) RnD Haldwani
AGE (I) RnD Haldwani PO Arjunpur 263139
REPAIR/MAINT OF DG SETS, REPAIR/REPLACEMENT OF LT PANELS AND OTHER MISC E/M WORKS AT DIBER HALDWANI UNDER AGE(I)RnD HALDWANI
2019_MES_309098_1
AGE(I)RnD/HLD/ 28 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
Haldwani
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) RnD Haldwani
₹14,000
Yes
30 Mar 2020
24 Dec 2019
25 Jan 2020
24 Dec 2019
23 Jan 2020
9 Jan 2020
24 Dec 2019 - 9 Jan 2020
Amount
Contract Details
Disconnecting, dismantling,and taking out of unserviceable Analog type Ampermeter from HT panel box and supply and fixing new three phase Ampere meter digital type CT operated, of range (0-40 Amps), of size 96x96mm for HT 11 KV, including necessary control wire connection and necessary thimbles nut bolts etc testing complete all as directed.
Disconnecting, dismantling,and taking out of unserviceable Analog type voltmeter from HT panel box and supply and fixing new three phase voltmeter digital type PT operated, of range (0-15 KV), of size 96x96mm for HT 11 KV, including necessary control wire connection and necessary thimbles nut bolts etc and testing complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable illuminated projecting push button assembly LED type from HT panel and supply and fixing new illuminated projecting push button assembly LED type including making connections with 2.5 Sq mm copper conductor single core PVC insulated cable and necessary thimbles nut bolts etc complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable Indicator lamp assembly LED type from HT panel and supply and fixing new Indicator lamp assembly LED type including making connections with 2.5 Sq mm copper conductor single core PVC insulated cable and necessary thimbles nut bolts etc complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable MCCB 160 A any type any description and Supply and fixed new MCCB Triple pole, 160 Amps 415 volts, 50 Hz having breaking capacity 36 KA , with fixed thermal and fixed magnetic setting and testing Complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable MCCB 250 A any type any description and Supply and fixed new MCCB Triple pole, 250 Amps 415 volts, 50 Hz having breaking capacity 35 KA , with fixed thermal and fixed magnetic setting and testing Complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable MCCB 200 A any type any description and Supply and fixed new MCCB Triple pole, 200 Amps 415 volts, 50 Hz having breaking capacity 35 KA , with fixed thermal and fixed magnetic setting and testing Complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable MCCB 100 A any type any description and Supply and fixed new MCCB Triple pole, 100 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with fixed thermal and fixed magnetic setting and testing Complete all as specified and directed.
Supply and fix in repair HT 11 KV out door type gang operated air break switch(GOD) triple pole mechanically operated mounted on insulator and steel frame with operating mechanism work from ground level suitable for horizontal or vertical mounting fixed type complete with 9 insulator of rating upto 200 Amp
Disconnecting and taking down old LT panel and Supply, installation, testing and commissioning outdoor type cubicle panel board suitable for 3 phase 4 wire 415 v, 50 Hz and type tested at CPRI for 35 MVA rupturing capacity at 415 volts factory fabricated in an approved factory having modern fabrication and comprising of following :- ( mentioned in srl no. 12.10 here in below ) SHELL. Shell shall be made out of 2.0mm thick CRCA sheet duly compartmentalized for each control gear, front and back openable double door system lockable/openable by keys from both sides, having louvers and air vent gasket for natural flow of air. ‘U’ type gasket shall be used to make the inner shell completely vermin proof and to accommodate incoming / outgoing MCCBs and TPN, bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB, the TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made of non hygroscopic non combustible track resistant, high strength FRP/SMC/DMC material at an interval not less than 500mm through out the length of the TPN bus bar.
(a) Incomer - MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 KA with adjustable thermal & magnetic setting, of Make : Havells /L&T /C & S Electric /Standard/HPL. Qty – 01 No(b) Out Going - (i) MCCB, 100 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 KA with adjustable thermal & magnetic setting, of Make : Havells /L&T /C & S Electric /Standard/HPL. Qty – 05 No (ii) MCB DP, 40 Amps (`C’ series ) having current rating 10 KA ( Make : Havells/C & S Electric / L&T (Hager)/ Siemens ) –Qty-02 Nos. (c) MCB TP, 40 Amps (`C’ series ) having current rating 10 KA ( Make : Havells/C & S Electric / L&T (Hager)/ Siemens ) –Qty-02 Nos. (d) Digital Ammeter 3 Phase AC 0 – 250 Amps, with 3 current transformer of suitable ratio and capacity Make : Legrand/L&T/AE Qty -01 No. (e) Indicating lamps LED type for three phases -R Y B of 3 Nos,(1 Set) (f) Digital Voltmeter 3 Phase AC 0 – 500 Volts. Make : Legrand / L&T/AE Qty -01 No. (g) Bus-bar chamber having 3 nos insulated aluminium bus-bar of 400 Amps rating and one No. bus bar of 200 Amps rating of suitable shape and size.
Disconnecting and taking down old LT panel and Supply, installation, testing and commissioning outdoor type cubicle panel board suitable for 3 phase 4 wire 415 v, 50 Hz and type tested at CPRI for 35 MVA rupturing capacity at 415 volts factory fabricated in an approved factory having modern fabrication and comprising of following :- ( mentioned in srl no. 13.01 here in below ) shall be made out of 2.0mm thick CRCA sheet duly compartmentalized for each control gear, front and back openable double door system lockable/openable by keys from both sides, having louvers and air vent gasket for natural flow of air. ‘U’ type gasket shall be used to make the inner shell completely vermin proof and to accommodate incoming / outgoing MCCBs and TPN, bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB, the TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made of non hygroscopic non combustible track resistant, high strength FRP/SMC/DMC material at an interval not less than 500mm through out the length of the TPN bus bar.
(a) Incomer - MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 KA with adjustable thermal & magnetic setting, of Make : Havells /L&T /C & S Electric /Standard/HPL. Qty – 01 No. (b) Out Going- (i) MCCB, 100 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 KA with adjustable thermal & magnetic setting, of Make : Havells /L&T /C & S Electric /Standard/HPL. Qty – 02 Nos (ii) MCB DP, 40 Amps (`C’ series ) having current rating 10 KA ( Make : Havells/C & S Electric / L&T (Hager)/ Siemens ) –Qty-02 Nos. (c) MCB TP, 40 Amps (`C’ series ) having current rating 10 KA ( Make : Havells/C & S Electric / L&T (Hager)/ Siemens ) –Qty-01 Nos. (d) Digital Ammeter 3 Phase AC 0 – 250 Amps, with 3 current transformer of suitable ratio and capacity Make : Legrand/L&T/AE Qty -01 No. (e) Indicating lamps LED type for three phases -R Y B of 3 Nos,(1 Set) (f) Digital Voltmeter 3 Phase AC 0 – 500 Volts. Make : Legrand / L&T/AE Qty -01 No. (g) Bus-bar chamber having 3 nos insulated aluminium bus-bar of 400 Amps rating and one No. bus bar of 200 Amps rating of suitable shape and size.
Notes for item no 12.00 and 13.00 The cubicle incomer MCCB as well as outgoing shall have TPN copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be of suitable size supported on suitable size ‘F’ class insulators made of non hygroscopic, non combustible, track resistant, high strength FRP/SMC/DMC material having provision for termination of incomer and outgoing cables. All inter connections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminum bus bar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves. All control wires shall be with PVC insulated and sheathed 2.5 sqmm multistrand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of copper lugs. The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coating having thickness not less than 100 microns. A detachable predrilled gland plate of thickness 2mm powder coated should be used at the bottom. The inner shell shall be powder coated Siemens grey structural RAL 7032 shade. The degree of protection for shell shall be IP-42, with following switchgears :-
Dismantling and opening parts of water cooled DG set of following capacity including coupled alternator with the engine unit for repair, Maintenance and servicing mechanically and electrically, including cleaning, oiling/greasing, removing & replacement of defective / oiling/greasing, removing & replacement of defective / unserviceable parts with new parts,ie ‘O’ rings/dieselfilter /oil filter /Air filter /fan belt /hose/Engine Oil etc as required at site and manufacturer's instructions and checking of valves & nozzles etc, reassembling the DG set ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site on full load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Srl No. 14.01 here in below)
Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge (iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Supply only” and shall be measured and paid separately under appropriate item of Sch ‘A’ . Its cost of filling is deemed to be included under the rates quoted by the contractor for above item.
320 KVA 3 phase 50 HZ (Cummins)
30 KVA 3 phase 50 HZ (Make : Kirloska)
Supply only element diesel filter with gasket suitable for following capacity of DG set dismantled/fixed under Sch `A` item No 14.01 to 14.03 here in above complete all as specified and directed.
30 KVA (Kirloskar)
320 KVA (Cummins)
Supply only element Oil filter with gasket suitable for following capacity of DG set dismantled/fixed under Sch `A` item No 14.01 to 14.03 here in above complete all as specified and directed.
30 KVA (Kirloskar)
320 KVA (Cummins)
Supply only element inner and outer air cleaner suitable for 320 KVA capacity 3 phase 50 HZ of DG set dismantled/fixed under Sch `A` item No 13.10 here in above complete all as specified and directed.
Supply only lubrication oil SAE-40 ( 20 W- 40 grade) Suitable for Engine of DG set any capactiy drainedout/filling under Sch 'A' item 13.10 to 13.11 here in above complete all as specifioed and directed.
Supply only concentrated coolent suitable for radiator of DG set any capacty drainedout/filling under Sch 'A' item No here in above complete all as specfied and directed.
Supply only fan belt suitable for followinhg capacrtity of DG set dismantled/fixed under Sch 'A' item here in above complete all as specified and directed.
30 KVA 3 phase 50 HZ (kirloskar)
320 KVA 3 phase 50 HZ (Cummins)
Dismantling and taking out the self starter, 24 Volt DC fitted in 320 KVA 3 phase 50 HZ nof DG set (Make Kirloskar) and strip opening of self starter 24 volt DC for carrying out repair/servicing/overhauling mechanically, cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing and replacement of defective/unserviceabnle part with new parts, complete and re-assembling of self starter 24 volt DC after repair/servicing/overhauling andf fixing the same in position and testing complete all as specified and directed. Notes: (i) Repair/servicing/reassembling and tresting of self startter 24 volt DC shall be carried out rhrough a authorised service centre (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch 'A' a ' supply only' but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/packing/studs etc. (iii) The quoted rates of contactor are deemed to be included cost of transportation to and from authorised service centre.
Supply only Solenoid switch suitable for self starter, 24 volt DC of DG set capacity, 320 KVA 3 phase 50 HZ dismantled/fixed under Sch 'A' item No 20.00 here in above complete all as specified and directed.
Supply onlyCommutator suitable for self starter, 24 volt DC of DG set capacity, 320 KVA 3 phase 50 HZ dismantled/fixed under Sch 'A' item No 20.00 here in above complete all as specified and directed.
Supply only Carbon Brush suitable for self starter, 24 volt DC of DG set capacity, 320 KVA 3 phase 50 HZ dismantled/fixed under Sch 'A' item No 20.00 here in above complete all as specified and directed.
Supply only Bendex assembly suitable for self starter, 24 volt DC of DG set capacity, 320 KVA 3 phase 50 HZ dismantled/fixed under Sch 'A' item No 20.00 here in above complete all as specified and directed.
Supply only Spring washer suitable for self starter, 24 volt DC of DG set capacity, 320 KVA 3 phase 50 HZ dismantled/fixed under Sch 'A' item No 20.00 here in above complete all as specified and directed.
M & L for Cleaning of MS fuel tank of DG sets of various capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank and cleaning the tank with kerosene oil , including replacement of fuel tank strainer and fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
Disconnecting , dismantling and taking out the non- functional fuel pipe and supply , fixing, connecting and testing fuel rubber flexible pipe wire braided from fuel filter to pump including fittings suitable for 320 KVA 3 phase 50 HZ DG sets complete all as specified and directed.
Labour only for checking the serviceableaty of the different spares/components/parts of security light/post top lantern light fittings ( HPSV, metal halide, flood light fittings etc , any wattage/capacity) of any description and fixed in any position , replacement of unservicable/damaged/broken parts either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position connecting to electric supply and its testing on installation complete all as specified and directed.
NOTES:- (i) Replacement of parts i.e lamps, choke, Igniter, Condenser, Holder, covers etc for HPMV/HPSV/MH/Flood light fittings any wattage & capacity, if any required at site, shall be measured and capacity, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A' as ‘supply only’ . The contractor shall maintain a register showing details of poles with distinct location on which fittings are repaired by using spares/parts supplied by him, the Eng-in-Charge shall verify the fact from site and thereafter it will jointly signed and kept on record, the register shall be produced to AGE alongwith every payment claimed by the contractor and shall be deposited to Eng-in- Charge after completion of work. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.
(ii) Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. This condition shall be applicable for the fittings in which contractor has provided materials other than Govt supply. (v) Contractor’s quoted rates for this item is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed.
Supply only porcelain holders screw type for single ended elliptical/tubular lamps of 70/100 watt HPSV/MH, 80/125 watt HPMV and 150 watt MH light fittings of any description dismantled/fixed under Sch `A` item No 24.00 here in above complete all as specified and directed.
Supply only porcelain holders screw type for single ended elliptical / tubular lamps of 150/250 watt HPSV, 250 watt MH and 250 watt HPMV light fittings of any description dismantled/fixed under Sch `A` item No 24.00 here in above complete all as specified and directed.
Supply only the following parts for HPSV/MH fittings dismantled/fixed under Sch `A` item No 24.00 here in above complete all as specified and directed.
Lamp for HPSV fittings, 70 Watt capacity screwed & tubular type.
Lamp for HPSV fittings, 150 Watt capacity screwed & tubular type.
Lamp for HPSV fittings, 250 Watt capacity screwed & tubular type.
Open construction ballast for HPSV/MH fittings, 250 watts, copper wound.
Open construction ballast for HPSV/MH fittings, 150 watts, copper wound..
Open construction ballast for HPSV/MH fittings, 70 watts, copper wound.
M&L for applying one coat of synthetic enamel paint on old steel suraface ie.panel and feederpiller box as existing colors incl numbering and marking as per existing incl preparation of old surface complete all as specified and directed.
Disconnecting and taking out existing light fitting of any description and in any position on walls including rusted brackets complete and Supply, fixing & testing 30 W LED flood light fitting mounting type made out of one piece in pressure die-cast aluminium, alloy powder coated housing enclosed with glass cover in frame fitted luminaries complete with all accessories and suitable for & including lamp 30 W high power COB LEDs . The fitting shall IP 65 protection, duly prewired suitable for and including mounting bracket made of MS Angle Iron 40x40x5mm , 900mm long, bent to shape cutting,drilling of holes & welding as required & directed etc fixed/grouted on wall with fastner's nut,bolt washers as required and including painted with two coat of aluminium paint over a coat of red oxide primer with and including connecting the fitting to bus bar box/Main switch with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor copper conductor cable complete all as specified and directed Cat Part No: LHEPCZUEIN6W030 of model JETA30 LED IP65 of Make Havells or equivalent model of specified make as approved by AGE(I).
Disconnecting and taking out existing light fitting of any description and in any position on walls including rusted brackets complete and Supply, fixing & testing 24 W LED road way light fitting mounting type made out of one piece in pressure die-cast aluminium, alloy powder coated housing enclosed with glass cover in frame fitted luminaries complete with electronic driver and all accessories suitable for & including lamp 24 W with suitable No's of LEDs . The fitting shall IP 66 protection, duly prewired complete with and including connecting the fitting to bus bar box/Main switch with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor copper conductor cable complete all as specified and directed Cat Part No: LHETAXU7UN6W024 of model ENDURA CITYLINER NEO of Maske Havells or equivalent model of specified make as approved by AGE(I). Note : GI pipe bracket and clamps if required shall be measured and paid separately.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep in any type of soil including forming sides and bottom surface to required levels/slopes/gradients etc. complete all as specified and directed at site.
M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed .
M&L for old size sub class `B` bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed .
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable of size 10 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 10 square mm, 4 core conforming to IS 7098 Part-I or IS 1554 Part-I. complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable of size 16 Sqmm 2 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 16 square mm, 2 core conforming to IS 7098 Part-I or IS 1554 Part-I. complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable of size 16 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 16 square mm,4 core conforming to IS 7098 Part-I or IS 1554 Part-I. complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable of size 25 Sqmm 2 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 25 square mm, 2 core conforming to IS 7098 Part-I or IS 1554 Part-I. complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable of size 25 Sqmm 3.5 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 25 square mm,3.5 core conforming to IS 7098 Part-I or IS 1554 Part-I. complete all as specified and directed.
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI tubing, 40 mm bore, light grade as in sleeving etc laid in trenches / pole post etc. complete all as specified and directed .
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc. complete all as specified and directed .
Supply install testing and connecting in replacement high performance tubular battery 12 Volt 150 AH suitable for DG set 320 KVA as per existing one Make Exide,Luminous, Amron
Supply and topping up Electrolite for topping up of battery
Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth lead GI strip 32mmx6mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth strip connected to main switch board protected by galvanised iron light grade pipe 40 mm bore in wall/floor/and GI Pipe 20mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009( Part-I).
Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth lead GI wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron light grade pipe 15mm bore in wall/floor/and GI Pipe 20mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009( Part-I).
Supply and lay rubber insulating mat of size 1 meter X 2 meter X10 mm thick all as directed
Supply and lay rubber insulating mat of size 1 meter X 2 meter X19 mm thick all as directed
Supply and fixed in replacement high performance tubular battery 12 Volt 75 AH suitable for solar street light fitting with cover and fixing arrangement
S&F in replacement capicitor metalized poly propylene type S(MPP - S) for three phase 440 Volt 50 Hzfor permissible non linear loadof 10 % of capacity 25 KVAR
Supply and fix in repair HT 11 KV out door type dropnout fuse assembly comple with six insulator and MS frame and fuse assembly complete triple pole fixed type complete all as directed of rating upto 200 Amp
M&L for reparing of old LT Panels/feeder piller such as alingment of both doors , repair / replacement of locking arrangement, door hinges, welding at cracks , uprighting and fixing properly all as directed at site.
Note :-Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S BHATT ENTERPRISES
M/S Pooja Construction
Amit Engineering
basant ballabh punetha
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .