Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.6 L+₹5.6 L (17.0%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹39.7 L+₹6.7 L (20.4%)Rejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹41.9 L+₹8.9 L (27.0%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Rejected being |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
4 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NORTH) AMBALA CANTT
GE(NORTH) AMBALA CANTT
CA NO GE(N)AMB-29/2022-23 DAY TO DAY MAINTENANCE AND PETTY REPAIRS OF E/M COMPLAINTS AND OTHER ALLIED WORKS IN OTM ACCN AT SECTOR B OF AGE E/M (NORTH) UNDER GE (NORTH) AMBALA CANTT
2022_MES_533012_1
GE(N)Amb-29/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE(NORTH) AMBALA CANTT
As per tender documents
9 documents required · 9 mandatory
₹500
GE(NORTH) AMBALA CANTT
₹88,000
Yes
17 Sept 2022
23 Jun 2022
6 Aug 2022
23 Jun 2022
4 Aug 2022
6 Jul 2022
23 Jun 2022 - 6 Jul 2022
60 days
Amount
Supply & Fix switch piano, flush type, single pole, one way, 6 Amp including removing unserviceable switch,complete all as specified and as directed by the Engr-in-charge.
Supply & Fix bell push 6 Amp, flush type including removing unserviceable bell push, complete all as specified and as directed by the Engr-in-charge.
Supply & Fix socket outlet 2 in 1, 3 pin, 6 Amp, flush type including removing unserviceable socket outlet, complete all as specified and as directed by the Engr-in-charge.
Supply & fix switch piano, flush type, single pole, one way, 16 Amp including removing unserviceable switch,complete all as specified and as directed by the Engr-in-charge.
Supply & fix as in repair socket outlet, 2 in 1, 6 pin, 6 and 16 Amp, flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Step fan regulator electronic socket type, flush type 230 volt including removing unserviceable regulator, complete all as specified and as directed by the Engr-in-charge.
Supply & Fix Step fan regulator electronic switch type, flush type 230 volt including removing unserviceable ragulator, complete all as specified and as directed by the Engr-in-charge.
Supply & fix in replacement of capacitor 2.5 mfd for ceiling fans of any descriptions , complete all as specified and as directed by the Engr-in-charge.
Supply & fix calling bell ding dong 230 volt including removing unserviceable bell, complete all as specified and as directed by the Engr-in-charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete including removing unserviceable ceiling rose, complete all as specified and as directed by the Engr-in-charge.
Supply and fix lamp holder, insulated body, with back plate for angular batten fittings complete all including taking down unserviceable lamp holder complete all as specified and as directed by the Engr-in-charge.
Material and labour for laying 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through existing conduit/casing & caping as in repair complete all as specified and as directed by the Engr-in-charge. Note:- Thimble/lugs of rating of MCB shall be used with wire for fixing in MCB
Material and labour for laying 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through existing conduit/casing & capping as in repair complete all as specified and as directed by the Engr-in-charge. Note:- Thimble/lugs of rating of MCB shall be used with wire for fixing in MCB
Material and labour for laying 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through existing conduit/casing & capping as in repair complete all as specified and as directed by the Engr-in-charge. Note:- Thimble/lugs of rating of MCB shall be used with wire for fixing in MCB
Material and labour for laying 6.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through existing conduit/casing & capping as in repair complete all as specified and as directed by the Engr-in-charge. Note:- Thimble/lugs of rating of MCB shall be used with wire for fixing in MCB
M&L for rectifying the short circuit of internal wiring/ sub main wiring, replacement of MCCB's/MCB's/RCBO's/Switches/Sockets etc of existing ratings/size as required at site.
M&L for rectifying the current leakage /electric shock of internal wiring/ sub main wiring ensuring that no leakage current passes Note for Item No. 16 to 17 :- (i) Contractor or his authorised rep will report daily at 0900 hrs and onwards at complaint cell for collection of complaints from the concerned JE's In charge and distribute all complaints/ detailing to his tradesmen, monitoring the work done and taking the complaint slip back from trademans on every working day, re-submit the same to JE's in charge after rectifying the complaint at complaint cell. In case contractor or his rep failed to attend the office then a recovery of Rs 1000/- per day shall immediately be effected from the contractor's dues in terms of conditions 25, 44 & 45 of IAFW-2249 (General Conditions of contracts). (ii) The complaint shall be attended & defect shall be rectified within 08 hrs i.e from 0900 hrs to 1700 hrs (excluding sunday & gazetted holiday), commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.150/- per complaint per hour shall be levied upon/imposed on the contractor and necessary recovery shall be effected from his dues on this account. In case, after checking & attending the defects, if it is not possible to rectify the defect within 08 hrs, the fact shall be brought to the notice of Engr-in-Charge by the contractor/ his rep immediately and if Engineer-in-Charge is satisfied with the facts brought by the contractor, no recovery shall be made on this account. (iii) All T&P required for attending the complaints shall be provided by the contractor without any extra. (iv) The electrician shall always be in possession of all planner, screw drive, taster, tap and ladders etc. as required at site or will be arrange by contractor on site on own expenditure and deemed to be included unit quoted rates. (v) The above all aspect shall be deemed to be included in the quoted rate of the respective item. (vi) New item/fittings such as MCCB/MCB/RCBO/switches/sockets/wire/light fittings etc. if to be replaced shall be measured and paid for separately under respective items
S & Laying PVC insulated and PVC round sheathed, copper conductor(flexible) industrial cable 3 core, 2.5 Sqmm, 1100 volts confirming to IS: 694 cable including taking down old unserviceable cable complete all as specified and as directed by the Engr-in-charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty, 2 core, 6 sq mm nominal cross section cable with PVC insulated aluminium conductor multistrand served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old unserviceable existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty, 2 core, 10 Sqmm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old unserviceable existing cable complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down unserviceable bulbs complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down unserviceable bulbs complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing indoor decorative LED tube light fitting box type 1x18/20 watt with opal diffuser, high efficient PVC housing body in suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 1x18/20 watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge.
Supplying and fixing in replacement LED tube rod 18/20 watt, 4 feet, aluminium body, cool/warm tube rod industrial model with high frequency power factor suitable for surface mounting batten fitting complete including disconnecting and taking down unservicable tube rod of any type complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing recess mounting LED 15/18 watt circular down lighter/ COB panel with aluminium die cast housing, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with 3 core flexible wire copper conductor from ceiling rose to connector of the light, including disconnecting and taking down existing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SP 6-32 Amps, 240 volt,10 KA, 'C' curve including removing old unserviceable MCB complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SPN 32/40 Amps, 240 volt,10 KA, 'C' curve including removing old unserviceable MCB complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB TPN 63 Amps 240 volt, 10 KA, 'C' curve including removing old unserviceable MCB complete all as specified and as directed by the Engr-in-charge.
S&F MCCB 3 pole , 63 Amp, 415 Volts, 16 KA ,fixed type including fixing arrangement, including removing old unserviceable MCCB complete all as specified and as directed by the Engr-in-charge.
S&F MCCB 4 pole , 100 Amp, 415 Volts, 25 KA ,fixed type including fixing arrangement, including removing old unserviceable MCCB complete all as specified and as directed by the Engr-in-charge.
Supply and fix RCBO 32 Amps, 2 Pole, 2 module, 100 mA (HI immunity) sensitivity, 230 volts, 50 Hz, including removing old unserviceable RCBO complete all as specified and as directed by the Engr-in-charge.
Supply and fix RCBO 40 Amps, 2 Pole 2 Module, 300 mA, (HI immunity) sensitivity, 230 volts, 50 Hz, including removing old unserviceable RCBO complete all as specified and as directed by the Engr-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with acrylic double door,IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) with MCCB 125 Amp, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fixing LED flat panel 2' x 2' size fully difused surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt , 5700K, warm/cool white with powder coating and CRCA front cover including frame with provision of PVC flexible copper conductor cable to light fitting as in repair complete all as specified and as directed by the Engr-in-charge.
S & F LED Bollard 8-10 watt, IP-65 , 6500 K luminaire made of pressure die cast aluminium housing and clear glass , 240 volt, 50HZ, AC supply , complete with all accessories internally pre wired including connecting with three core flexible copper conductor cable from electric supply source to connector of the light including PCC 1:3::6 of size 400x400x400 mm as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F LED post top luminaire 30W- 35W, 5700K, IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with fitting and including provision of 3 core PVC flexible copper conductor from electric supply source to connector of the light, including disconnecting and taking down existing light fitting and removing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of MS pipe 25 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over a coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
Supply and fixing LED batten fitting 10-12 watt, 2 feet, 6500K aluminium housing and electronic driver including tube rod cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED batten fitting 18-20 watt, 4 feet, 6500K aluminium housing and electronic driver including tube rod cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, auminum housing, surge protection including driver & LED lamp etc complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing LED Flood lights, 120 watt, IP-66, aluminum die cast housing with unique lens system and toughened glass with gasket 240 volt, 50Hz, AC supply complete with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements, including disconnecting and taking down existing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
M&L arresting the leakage of the geyser by applying brazing to inner tank and refixing the inner tank after making it functional all as specified and as directed by Engr-in-charge. Note : Adequate water pressure will be apply to the brazed tank to ensure that no leakage is left, if the tank is still leaking the same will be repaired by the contractor and the cost of the same shall be deemed to be included in the quoted rate.
S & fixing heating element of 1.5/2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating element,complete all as specified and as directed by the Engr-in-charge.
S & fixing heating element cup or triangle type of 1.5/2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating elements all as specified and as directed by the Engr-in-charge.
S & F thermostat switch for geyser of any type ISI marked including taking out old unserviceable thermostat switch complete all as specified and as directed by the Engr-in-charge.
S & F geyser inner tank assembly suitable for geyser capacity of 25 Ltr including taking out old unserviceable tank assembly complete all as specified and as directed by the Engr-in-charge.
S & F geyser inner tank assembly suitable for geyser capacity of 50 Ltr including taking out old unserviceable tank assembly complete all as specified and as directed by the Engr-in-charge.
Supply & replacing inner tank made from 1mm thick copper sheet for geyser of 25 Ltr capacity including taking out old unserviceable inner tank complete all as specified and as directed by the Engr-in-charge.
S&F brass chromium plated non return valve 15mm bore with air lock release arrangement including taking out old unserviceable non return valve, complete all as specified and as directed by the Engr-in-charge.
S&replacing metal clad socket top as per existing socket including taking out old unserviceable metal clad top, complete all as specified and as directed by the Engr-in-charge.
S& replacing of inspection cover stainless steel in 2 piece suitable for geyser of 50/25 ltr capacity and having provision of fixing indicator lamps including taking out old unserviceable inspection covers all as specified and as directed by Engr-in-charge.
S & F in replacement flexible cable PVC insulated and sheathed, 3 core, circular multi stranded copper conductor of 1.00 Sqmm including removing unserviceable cable, complete all as specified and as directed by the Engr-in-charge.
S&F brass chromium plated gate valve of 15 mm bore suitable for fixing on existing fittings including taking out old unserviceable gate valves all as specified and as directed by Engr-in-charge.
S&F brass connection pipe having wire mesh coating over it with PTMT nuts and washers suitable for connecting geysers inlet and outlet with GI tubings including taking out old unserviceable brass connections all as specified and as directed by Engr-in-charge.
S&F GI tubing 20mm bore medium grade with all fittings as required at site i.e. elbow,socket,nipple, reducer & union for plumbing work and making connection as required at site including removing unserviceable pipe all as specified and as directed by Engr-in-charge.
S&F top plug 15 Amp, 3 pin including taking out old unserviceable plug top and removing unserviceable items,complete all as specified and as directed by the Engr-in-charge.
S&F indicating lamp green/red in colour 230 volts as per existing make including removing unserviceable items,complete all as specified and as directed by the Engr-in-charge.
S&F in repair mirror light 9/12watt LED wall mounting fixture, one feet , aluminium housing compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable items all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair modular PVC sheet/cover plate 3 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix in repair modular PVC sheet/ cover plate 4 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix in repair modular PVC sheet / cover plate 6 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
S&F as in repair modular switch 6 Amp, 1 way, 1 module, single pole, flush type, 230 volts complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
S&F as in repair switch modular 16 Amp, 1 way, 1 module, single pole, flush type, 230 volts complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
S&F as in repair socket outlet modular 2/3 pin combined, 6 Amp, 2 module, one way, 230 volts complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
S&F as in repair socket outlet modular 3/3 pin combined (6 pin), 6 &16 Amps, 2 module, one way 230 volts complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
S&F as in repair of step type electronic Fan regulator modular 120 watt, 2 module complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
S&F as in repair modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
S & F as in repairs LED driver suitable for 36 to 40 watt LED panel light 2'X2' complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items complete all as specified and as directed by the Engr-in-charge.
S & F as in repairs LED driver suitable for 45 watt LED security light fitting complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items complete all as specified and as directed by the Engr-in-charge.
S & F as in repairs LED driver suitable for 80-120 watt LED Flood light & high/medium bay light fitting complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items complete all as specified and as directed by the Engr-in-charge.
S & F as in repairs LED driver suitable for 30watt LED Post Top Lantern complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items complete all as specified and as directed by the Engr-in-charge.
S & F as in repairs LED driver suitable for 10-15 watt LED down lighter light fitting complete all as specified and as directed by the Engineer-in-Charge. Make: As per site requirement including removing unserviceable items complete all as specified and as directed by the Engr-in-charge.
S&F as in repair 9/12 watt LED light fitting wall mounting fixture (sketch type) including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
S&F LED 22 watt integrated batten with inbuilt lithium ion battery with minimum 4 hour back up including removing of unservicable light fitting complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp Invertor technology 9 watt with 4 hour power back up with efficiency more than 100 lumen per watt,Lithium ion battery including removing of unservicable lamp complete all as specified and as directed by the Engineer-in-Charge.
Taking down ceiling/exhaust/wall mounted/pedestal fans of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections and deposit at fan store of AGE EM north for issuing of fan to contractor for repair, and collecting the fan after repair and hanging the same at location directed by the concerned JE EM complete all as specified and as directed by the Engr-in-charge.
M&L for opening the stator & rotor of the 1200mm sweep ceiling fan, cutting the existing worn winding & rewinding the fan with superior quality copper wire & filling the varnish as insulation between each winds & covering each loops of winding by sleeves & paper & reassembling of complete fan by fixing serviceable old and new parts of fans i.e. rubber bush of condensor & shackle housing , condensor, gun metal bushes, ball bearings twin twisted copper cable down rod assembly with its shackle condenser housing & canopy ,split pins complete all as per manufacturers design air delivery including greasing, oiling & testing of fans all as per manufacturers design & speed complete all as directed & approved for 1200mm sweep. Notes for item NO (i) to (vii) :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule. (ii). The rates for refixing & taking out serviceable parts shall be deemed to be included of quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No on fans (v). Unserviceable /defective retrieved parts shall be credited vide sch of credit. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans shall be repaired/rewind at AGE E/M store yard only.
Description all as per srl item No 80 here-in-before but for 1400 mm sweep, complete all as specified and as directed by the Engr-in-charge.
Description all as per srl item No 80 here-in-before but for Exhaust fans of 225/250mm sweep, complete all as specified and as directed by the Engr-in-charge.
Description all as per srl item No 80 here-in-before but for Exhaust fans of 300mm sweep, complete all as specified and as directed by the Engr-in-charge.
Description all as per srl item No 80 here-in-before but for Exhaust fans of 450mm sweep, complete all as specified and as directed by the Engr-in-charge.
S & F new electric motor suitable for wall mounting fan 400/450 mm sweep of existing make complete all as specified and as directed by the Engr-in-charge.
Supply only GI 'U' clamp heavy duty with rubber reel of superior quality and nut and bolts with locking arrangement complete all as specified and as directed by the Engr-in-charge.
Supply only PVC canopy cover superior quality complete all as specified and as directed by the Engr-in-charge.
Supply only down rod 60cm long made out of 15 mm bore light grade GI pipe having provision of fixing U clamp & Fan including painting the pipe with superior quality white colour synthetic enamel paint complete all as specified and as directed by the Engr-in-charge.
Description all as per srl item No 88 here-in-before but 1m long, complete all as specified and as directed by the Engr-in-charge.
M&L for cleaning the fan motor assembly body, blade of ceiling fan, filling the cavity rubbing with sand paper, taking off old paint with the help of chemicals & painting the ceiling fan/Exhaust fan with one coat of superior quality synthetic enamel paint including writing the MES number on the ceiling fans of 1200mm sweep with black colour synthetic enamel paint complete all as specified and as directed by the Engr-in-charge.
Description all as per srl item No 90 here-in-before but for 1400 mm sweep, complete all as specified and as directed by the Engr-in-charge.
Description all as per srl item No 90 here-in-before but for Exhaust fans of 300mm sweep, complete all as specified and as directed by the Engr-in-charge.
Description all as per srl item No 90 here-in-before but for Exhaust fans of 450mm sweep, complete all as specified and as directed by the Engr-in-charge.
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans , complete all as specified and as directed by the Engr-in-charge.
Supply only bearing No 6202 for 1200/1400mm sweep ceiling fans , complete all as specified and as directed by the Engr-in-charge.
Supply only bearing No 6203 for 1200/1400mm sweep ceiling fans , complete all as specified and as directed by the Engr-in-charge.
Supply only capacitor 4 MFD dry type complete all as specified and as directed by the Engr-in-charge.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan ,complete all as specified and as directed by the Engr-in-charge.
Supply only fan blade suitable for 1200 mm sweep fan of existing make including removing Unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply only fan blade suitable for 1400 mm sweep fan of existing make including removing Unserviceable items, complete all as specified and as directed by the Engr-in-charge.
M/S Sonu Traders
u and v engineers and consultants
Saurav Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .