Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹30.9 L+₹1.0 L (3.47%)Rejected-AOC | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹33.9 L+₹4.0 L (13.4%)Rejected-AOC | L3 | Rejected-AOC L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
22 Aug 2023, 3:00 pmClosed
Deputy Vice President(Projects)
Project Division, HLL Lifecare Ltd, Corporate Head Office, Poojappura. P. O, Thiruvananthapuram 695012
Supply Installation Testing And Commissioning of Air Conditioning System and allied works for the Modification of LVP/SVP/Ophthalmic Plant facility at KSDP, Alappuzha
2023_HLL_591803_1
HLL/CHO/PRJ/EXT/KSDP/LVPSVP/AC
Open Tender
Electrical and Maintenance Works
Item Rate
56 days
Kalavoor
Please refer Tender documents.
14 documents required · 14 mandatory
₹2,950
Yes
₹50,000
Yes
27 Oct 2023
2 Aug 2023
23 Aug 2023
2 Aug 2023
22 Aug 2023
2 Aug 2023
Amount
Installation, testing & commissioning of VRV/VRF 4 way Cassette indoor unit complete, Including cutting the false ceiling. 1TR to 4TR.
Supply, installation, testing and commissioning, Transmission/Communication cabling, of 2 core 1.5 Sqmm non polar shelied cable for interconnecting the Indoor and Outdoor Units of all the VRV/VRF Units for proper performance , Communication cable must be routed throgh PVC pipe.
Supply, installation, testing & commissioning of VRV/VRF 4 way Cassette type direct expansion indoor units with individual blade control for all the four directions including blower, TEFC blower motor, suitable for operation on 240 volts ±10%,1 phase ,50HZ AC supply, copper tube aluminium finned direct expansion cooling coil, pre filters, electronic expansion valve with cordless remote and control wiring, drain connection with anti-vibration mountings, Fresh air connections etc., as required and as per scheduled of equipment and specifications. Power cabling upto 3 meters should be included. 4 TR
Supply, installation, testing & commissioning of VRV/VRF 4 way Cassette type direct expansion indoor units with individual blade control for all the four directions including blower, TEFC blower motor, suitable for operation on 240 volts ± 10%,1 phase ,50HZ AC supply, copper tube aluminium finned direct expansion cooling coil, pre filters, electronic expansion valve with cordless remote and control wiring, drain connection with anti-vibration mountings, Fresh air connections etc. as required and as per scheduled of equipment and specifications. Power cabling upto 3 meters should be included. 3TR
Supply, installation, testing & commissioning of VRV/VRF 4 way Cassette type direct expansion indoor units with individual blade control for all the four directions including blower, TEFC blower motor, suitable for operation on 240 volts ± 10%,1 phase ,50HZ AC supply, copper tube aluminium finned direct expansion cooling coil, pre filters,electronic expansion valve with cordless remote and control wiring, drain connection with anti-vibration mountings, Fresh air connections etc., as required and as per scheduled of equipment and specifications. Power cabling upto 3 meters should be included. 2 TR.
Supply, installation, testing & commissioning of VRV/VRF 4 way Cassette type direct expansion indoor units with individual blade control for all the four directions including blower,TEFC blower motor,suitable for operation on 240 volts,1 phase ,50HZ AC supply, copper tube aluminium finned direct expansion cooling coil, pre filters,electronic expansion valve with cordless remote and control wiring, drain connection with anti-vibration mountings, Fresh air connections etc., as required and as per scheduled of equipment and specifications.Power cabling upto 3 meters should be included. 1 TR
Supply, installation, testing & commissioning of VRV/VRF 4 way Cassette type direct expansion indoor units with individual blade control for all the four directions including blower, TEFC blower motor, suitable for operation on 240 volts,1 phase ,50HZ AC supply, copper tube aluminium finned direct expansion cooling coil, pre filters,electronic expansion valve with cordless remote and control wiring, drain connection with anti-vibration mountings, Fresh air connections etc., as required and as per scheduled of equipment and specifications. Power cabling upto 3 meters should be included. 1.5 TR
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units having all hermetically sealed inverter type Scroll Compressor(s) with inbuilt oil level sensor for improved safety & reliability of OEM make only, The unit should have factory manufactured anti corrosive technology for its condenser fins so as to resist corrosive environment created due to pollution, acidic rains. This Anticorrosive treatment should be with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 52°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant, and ready for use as required. The electrical power panel required for the system shall be designed, manufactured and installed, power & control cable from the panel to each units, earthing etc shall be provided . Suitable size power cable should be provided upto the electrical power panel from VRV. The electrical power panel should meet all the requirements of statutory authority. Necessary approval shall be obtained before execution from the Engineer-in-charge. 55 HP.
Supply, installation, testing and commissioning of special refrigerant connection joint kits for taking branch connections to the various Indoor Units, as required, for the complete installation and proper functioning of the VRV/VRF system.
Supply, installation, testing and commissioning of interconnecting insulated copper tubing, for refrigerant liquid and suction lines between the Outdoor and Indoor Units complete, including fittings like elbows, reducers etc. and suitable wall / ceiling clamps as required for the complete installation and proper functioning of the VRV/VRF system. The suction lines shall be insulated with 19 mm thick and discharge lines shall be insulated with 13mm closed cell antimicrobial nitrile rubber flexible hose insulation.
Supply, installation, testing and commissioning of drain piping of hard PVC pipe and fittings, insulated with 12 mm thick nitrile rubber.32MM.
Supply, installation, testing and commissioning of drain piping of hard PVC pipe and fittings, insulated with 12 mm thick nitrile rubber.25MM
HVAC WEATHER DESIGN
SHES Air & Automation Pune
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .