Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAccepted-AOC | ₹6.2 Cr | L1 | Accepted-AOC Lowest Bid Value |
| 2 | L2₹7.2 Cr+₹1.0 Cr (16.5%)Rejected-Finance | ₹7.2 Cr+₹1.0 Cr (16.5%) | L2 | Rejected-Finance Higher Bid Value |
Tender Value
Refer Docs
EMD Value
₹6.0 L
Closing Date
30 Nov 2020, 6:00 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA,KALAIKUNDA AIR FIELD POST, DIST WEST MEDINIPORE,721303
PROVISION OF PERMANENT BUILDING FOR LOGISTIC SECTION
2020_MES_385153_1
8219/BKP/81/E8
Open Tender
Civil Works
Lump-sum
560 days
AT AF STN BARRACKPORE
Class A, Category a(I)
2 documents required · 2 mandatory
₹3,000
Yes
GE AF BARRACKPORE
₹6.0 L
Yes
CWE AF KALAIKUNDA
10 Feb 2021
10 Oct 2020
3 Dec 2020
10 Oct 2020
30 Nov 2020
12 Nov 2020
12 Oct 2020 - 26 Oct 2020
27 Oct 2020
Amount
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of new LOGISTIC office Building and special item of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Storage accomodation Building of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of garage for C vehical of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of LPG Store of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Aerolube store and POL store of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Salvage yard of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Reciept and unpacking building bulk stores FSS of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Compressed Gas Yard of single story permanent specification including framed structure, seismic consideration ATT, APP roof treatment complete all as specified and shown in drawing.
Total amount of Sch 'A' Part-II (Site clearance and earthwork) Prepriced amount B/F from Sl page No. 37R1
Total amount of Sch 'A' Part-III (Internal Electrification) Prepriced amount B/F from Sl page No. 42
Total amount of Sch 'A' Part-IV (Internal water supply) Prepriced amount B/F from Sl page No. 43
Total amount of Sch 'A' Part-V (Road ) Prepriced amount B/F from Sl page No 45R
Total amount of Sch 'A' Part-VI (Path and culvert ) Prepriced amount B/F from Sl page No 47R
Total amount of Sch 'A' Part-VII (Sewage disposal) Prepriced amount B/F from Sl page No. 49R
Total amount of Sch 'A' Part-VIII (External water supply) Prepriced amount B/F from Sl page No. 50
Total amount of Sch 'A' Part-IX (External electric supply) Prepriced amount B/F from Sl page No. 54
Total amount of Sch 'A' Part-X (Area Drainage) Prepriced amount B/F from Sl page No. 56R
Total amount of Sch 'A' Part-XI (Gate and Fencing) Prepriced amount B/F from Sl page No. 59R
Total amount of Sch 'A' Part-XII (Lighting Protection) Prepriced amount B/F from Sl page No. 60
Total amount of Sch 'A' Part-XIII (Demolition ) Prepriced amount B/F from Sl page No.61R
Sch 'A' Part-XIV (Misc Items) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
Construction of RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users complete as shown in drg and as directed. Note : Rate incl for dewatering during construction
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ RCC cover, interconnecting DWC pipes complete filled with brick bats of size 1.8 x 3 m depth complete as shown in Drg and as directed Note : Rate incl for dewatering during construction
Supply and fixing LED light fitting flame proof totally enclosed type 1x20 watt , IP 65 Protection, CMRI certified, ISI marked with all accessories internally pre-wired complete all as specified and directed by Engr-in-Charge.
Supply, assembling & fixing Flame proof exhaust fan with louvers complete of 305mm (12") sweep, 230 volts, single phase, AC supply complete with bolts, nuts, and washers size of the bolts 6 inch long 6mm dia embedded in the wall including provisioning of flexible cord copper of size 23/0.0076 three core from ceiling rose to exhaust fan for giving connection and providing continues earthing connection complete all as specified. Note:- (a) cost to the suitable opening in wall for fixing of exhaust fan is deemed to be included in the cost of building.
Supply & fixing double door MCB DB SPN horizontal type for single phase outgoing made of steel sheet phosphatised powder painted,240 Volt with busbar rated 200 Amp, neutral link, Earth bar and Din Rail and having IP 42 Protection for size 6 Way complete all as specified & as directed by Engr-in-Charge.
Supply & fixing double door MCB DB TPN , VTPN, MCCBs as incomer type and single phase outgoing made of steel sheet phosphatised powder painted,440 Volt with busbar rated 200 Amp, neutral link, Earth bar and Din Rail and having IP 42 Protection for size 4 Way, (MCCB+12 module) Incomer is 3 pole V-Tec MCCB of 100Amp rating 25kA breaking capacity. MCCB is pre fitted at factory & included in price list all as specified and directed by Engr-in-Charge
Supply & fixing double door MCB DB TPN , VTPN, MCCBs as incomer type and single phase outgoing made of steel sheet phosphatised powder painted,440 Volt with busbar rated 200 Amp, neutral link, Earth bar and Din Rail and having IP 42 Protection for size 6 Way (MCCB+18), Incomer is 3 pole V-Tec MCCB of 100Amp rating 25kA breaking capacity. MCCB is pre fitted at factory & included in price list all as specified and directed by Engr-in-Charge
Supply & fixing double door MCB DB TPN , VTPN, MCCBs as incomer type and single phase outgoing made of steel sheet phosphatised powder painted,440 Volt with busbar rated 200 Amp, neutral link, Earth bar and Din Rail and having IP 42 Protection for size 8 Way (MCCB+24), Incomer is 3 pole V-Tec MCCB of 100Amp rating 25kA breaking capacity. MCCB is pre fitted at factory & included in price list all as specified and directed by Engr-in-Charge
S & F MCB Single pole 10 KA C curve 6-32Amps complete all as specified and as directed by Engineer in Charge.
S & F MCB Single pole 10 KA C curve 40-63 Amps complete all as specified and as directed by Engineer in Charge.
S & F MCB Single pole and neutral 10 KA C curve 6-32 Amps complete all as specified and as directed by Engineer in Charge.
S & F MCB Triple pole and neutral 10 KA C curve 63 Amps complete all as specified and as directed by Engineer in Charge.
M&L for street light bracket (suitable for LED fittings upto 1.5 RM make out of GI pipe of medium grade 40mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape fixed on building wall all as pecified and directed by Engineer-in-Charge.
Supply, assembling & fixing exhaust fan with louvers complete of 300 mm sweep, 230 volts, single phase, AC supply complete with bolts, nuts, and washers size of the bolts 6 inch long 6mm dia embedded in the wall including provisioning of flexible cord copper of size 23/0.0076 three core from ceiling rose to exhaust fan for giving connection and providing continues earthing connection complete all as specified. Note:- (a) cost to the suitable opening in wall for fixing of exhaust fan is deemed to be included in the cost of building.
S&F Sleek 1x5 Watt Linnet sleek LED mirror lihgt provider with high output diffuser including accessories complete as specified and as directed by Engr-in-Charge
Supply and fixing LED Lamp 7watt complete all as specified and directed.
S&F wall mounted fan of 400 mm sweep, 240 volts, 50Hz, high speed and connecting up including provision of cable from ceiling rose or connector to fan with flexible copper cable of suitable size complete all as specified and as directed by Engr-in-Charge
M&L sub main wiring (concealed type) in & including PVC Rigid conduit of 25mm dia with four single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 10 sqmm nominal cross sectional area each drawn into and all accessories including two Nos single core 10 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Four run single core cable, Two run of earth conductor and one run on PVC conduit shall be measured as a unit length.)
M&L sub main wiring (concealed type) in & including PVC Rigid conduit of 20mm dia with two single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 6 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 6 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run on PVC conduit shall be measured as a unit length.)
M&L sub main wiring (concealed type) in & including PVC Rigid conduit of 20mm dia with two single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 4 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 4 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run on PVC conduit shall be measured as a unit length.)
Supply & fixing blanking kit for MCB DBs complete all as specified and as directed.
S&F water jet spray complete all as specified & directed
S&F Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigments complete all as specified and directed.
M&L Preparation of new or previously treated surfaces and laying of hot applied thermoplastic compound 2.5 mm thick including thermoplastic paint @ 5.5 Kg(MOST) and reflectorising glass beads @ 250 gm/sqm area, thickness of 2.5 mm is inclusive of surface applied glass beads as per IRC: 53. all as specified and as directed
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 75 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 40 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site.
Supply and fixing CI sluice vlave of siz 80mm (3") dia, flanged type as per IS: 14846/2000 PN-1.0 G.M. Working parts SS-410 spindle with hand wheel including fixing with nuts/bolts/washer/gasket of suitable size all as required and directed.
M&L for reconstruction of brick masonry valve pit of size 100cm x 100 cm x 100cm (internal dimension) with one brick thick P.C.C 1:4:8 type D-2 (using 20mm graded crashed stone aggregate) as in foundation concrete incl PCC (1:3:6) type CI (using 20mm graded crashed stone aggregate) as in bedding and coping 10mm thick cement plaster in Cement mortar (1:4) internally & externally upto 15 cm below ground level providing valve pit 50x50x6mm angle iron frame all round the fixed point by means of 4 Nos hold fast 150mm long made out of flat iron 25 x 5 mm embedded in PCC block (1:2:4) type B-I (using 20mm graded crashed stone aggregate) of size 230 x200 x100mm. incl provn of hing welded with angle iron frame and Mild Steel cover 3 mm thick, Mild steel handle of suitable and size welded with MildSteel cover & suitable locking arrangement & applying two coats of synthetic enamel paint over a coat of red-oxide primer incl necessary excavation work in soft/ loss soil complete all as specified & directed
M&L for bricks of fly ash bricks, for cable protection in trenches laid dry and flat complete all as specified and directed.
M&L for HDPE pipe PN 10, 75mm bore will all fittings for protection of cables to cross under road, hardstanding, pavement etc and make good disturbed surface complete all as specified and directed.
Supply, commissioning & testing transformer step down of capacity 160 KVA, outdoor type complete with standard fittings, No-load voltage ratio - 6600/433 Volt, Tapping on HV(%) +/- 7.5, +/- 5, +/- 2.5 volt, Phase & Frequency - 3 Phase & 50 Hz, Vector Group - Dyn 11, Connection - Delta/Star, Type of Cooling - ONAN including transformer oil upto required limit and PCC foundation all as directed by Engr-in-Charge Terminal Arrangement : (a) HV Side - Trifurcating cable box suitable to connecte XLPE cable. (b) LV Side - Quadfurcating cable box with two compression glands for PVC cable. One additional neutral bushing terminal will be brought out separately for earhing purpose. Fittings : (a) Externally hand operated off circuit tap switch with position indicator and locking device. (b) Conservator with oil gauge, filling holw with plug and drain hole with plug. (c) Undercarriage with four plain rollers - One (d) Oil-filling hole cum air release plug - One (e) Drain vlave cum sampling valve - One (f) Filter valve with plug - one (g) Rating plate & Diagram plate (h) Lifting lugs for lid - Two (j) Earthing terminals - Two (k) Thermometer pocket - One (l) Silicagel breather - one .
Supply, installation, testing and commissioning outdoor type Automatic Power Factor Correctrion LT capacitor bank made out of CRCA sheet of 3.15mm thick panel (MDXL), duly powder coated RAL 7035, capacity 100 KVAR in steps of 2 x 5 KVAR, 2 x 10 KVAR, 2 x 15 KVAR and 2 x 20 KVAR having following assessories including control wiring with HR FRLS copper wire complete :- (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry. (ii) Capacitor installed in removable asseblies for ease of operation and maintenance. (iii) Incommng of APFC panel of MCCB of capacity 200 Amp, 4 Pole 36 KA with IP-54 with high electrolytic grade aluminium bus bar of suitable rating. (iv) High performance microprocessor based 3 phase APFC relay 8 stage with Auto/Manual Option. (v) In built power analyzer, Amp Meter, Volt Meter, Power Factor Meter (Each 01 Nos) (vi) Capacitor duty contactors with high thermal carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitor. (vii) Induced air system provided with axil flow fan/centrifugal fan. (viii) Bottom cable enty system available with front glass for viewing controller and analyzer from front.
Supply installation, commissioning and testing including providing all necessary electrical connection, LT Feeder Pillar board, outdoor type (CPRI Approved, IP-54) double door, both side openable with ninged and locking arrangements with 4 legs of 0.6 mtr long, factory made out of 3.15 mm thick MS CRCA sheet of size 1.5 m x 1.2 m x 0.60 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 60 x 60 x 6mm thick with cable entry and exit circular hole with cable gland & gasket at bottom, duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate complete including following accessories:- INCOMMING (a) Copper bus bar of capacity 400 Amp--04 Nos (b) MCCB 250A (Adjustable Thermal and Adjustable Magnetic release ),415 Volts 4 pole, 36 KA - 01 Nos (incoming) (c) Indicator lamp LED type (set of three Red,Yellow,Blue)----01 Nos (d) Digital Multifunction meter, Model C, Class 1, RS485 Port,flush mounting 96 x 96mm - 01 Nos OUTGOING (a) MCCB 125A (Adjustable Thermal and Fixed Magnetic release),415 Volts 4 pole, 25 KA - 02 No (out going) (b) MCB TPN 10 Amp, 10 KA -03 Nos (Outgoing)
Supply, installation, commissioning and testing of LT feeder pillar of size 1.50 m x 1.20m x 0.60m factory made (CPRI approved, IP-54), outdoor type, double door, both side openable with hinged and locking arrangement with 4 legs of 0.6 mtr long, made out of 3.15mm thick mild steel CRCA sheet supported and fixed on structrual frame of angle iron of size 60 x 60 x 6mm angle iron frame including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), suitable for 3 phase 4 wire system 440 volts grade with necessary wiring with PVC sheathed stranded copper conductor of appropriate length size with and including fixing lugs, bolts, screws etc complete all as directed by the Engr-in-Charge and comprising of the following accessories :- INCOMMING (a) Copper bus bar of capacity 200 Amp--04 Nos (b) MCCB 125A (Adjustable Thermal and Adjustable Magnetic release ),415 Volts 4 pole, 25 KA - 01 Nos (incoming) (c) Indicator lamp LED type (set of three Red,Yellow,Blue)----01 Nos (d) Digital Multifunction meter, Model C, Class 1, RS485 Port,flush mounting 96 x 96mm - 01 Nos OUTGOING (a) MCCB 63A (Fixed Thermal & Fixed Magnetic Setting ), 415 Volts 4 pole, 16 KA - 03 No (out going) (b) MCB TPN 10 Amp, 10 KA -01 Nos (Outgoing)
M&L for fixing Street Light Panel 3 Phase 6 KW load wcontractor rating 32 Amp TP, MCB 40 Amp TPN with digital type timer all complete as specified and directed
M&L High galvanized mast light 15 meter height suitable for 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per manufacturere drawing/as per height all as required and directed.
Supply and fixing rectangular Intergral 160W LED flood litght with extruded aluminim heat sink, designed to act as efficient heat dissipater, pressure die cast aluminium cover on both sides for holding to ectruded aluminium heat sink, luminaire provided with heat resistant toughened glass, extruded aluminium control gear comparment is a integral part of luminaire, Degree of Protection IP 66, the driver should have surge vopltage, open/short circuit protection, provided with secondary lens optics to get optimum optical performance as per Bajaj Cat No BARFEG 169642 or equivelent make. LED should be colour temp 5700 degree K +/- 300 degree K all complete as specified and directed
Supply and fixing Integral LED aviation light comprising of aluminium alloy housing with polycarbonate enclosureas per Bajaj Cat No 110731 BGAV 302LED luminaire type. fittings including GI pipe 32mm (0.5 Mtr) and all fixing arrangement all complete as specified and directed
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all complete as specified and directed.
M/L for earthing complete with galvanised steel earth plate electrode of size 60 cm x60 cm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge not less than 1.5 m below ground level,connected to galvanised wire 4.0mm dia as earth lead by means of bolts, nuts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 5 of SSR part I, connected to earth test point all as specified or indicated complete with excavation, earth work, PCC 1:3:6 pit with RCC cover 50 mm thick with suitable handle made of 10mm dia MS bar, 20mm bore GI tubing medium grade for watering pipe, 15mm bore medium grade GI pipe for protection of 4.0mm dia GI earth lead, test point, GI funnel with wire mesh all as directed and specified and testing on completion.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI strip upto 7.5m including testing consider in this item).
Supply, Install, commissioning and testing of dehumidifier digital type continuous operating complete, with heaters, ducting, electrical connection for 180 cfm capacity complete as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR. complete as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity of 2 TR complete as specified and directed.
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 80 ltrs and nominal cooling capacity of 40 Ltrs per hour complete as specified and directed.
Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air colled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % and of capacity 5.0 KVA complete fixed on wall with suitable size of nut & bolt complete as specified and directed.
Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air colled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % and of capacity 4.0 KVA complete fixed on wall with suitable size of nut & bolt complete as specified and directed.
Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air colled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % and of capacity 1.0 KVA complete fixed on wall with suitable size of nut & bolt complete as specified and directed.
S & F Wiring for circuit/submain wiring of 2x6.0 sq. mm + 1x6.0 sq. mm earth wire alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required complete as specified and directed.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified.
S&F chain link fencing 100X100 mm mesh or cages witrh 3.8mm to 4.00 mm dia mild steel galavanized wire complete all as specified.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .