Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC C 234 ADG P CHENNAI | L1 | Accepted-AOC Accepted, being lowest | |
| 2 | L2₹28.8 L+₹1.5 L (5.43%)Rejected-AOC THEKKEKOTTARAM RAMANTHALI PO KANNUR DIST KERALA 670 308 | RAMANTHALI | KANNUR | KERALA | 670308 | L2 | Rejected-AOC Rejected, not being lowest | |
| 3 | L3₹29.2 L+₹1.9 L (6.84%)Rejected-AOC DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L3 | Rejected-AOC Rejected, not being lowest | |
| 4 | Rejected-Technical 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | - | Rejected-Technical Not enlisted for the Category |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2024_MES_668675_1
GE MAINT EZHIMALA 8679
Open Tender
Civil Works
Item Rate
90 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE MAINT EZHIMALA
₹71,000
Yes
8 Nov 2024
31 Aug 2024
4 Oct 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
31 Aug 2024 - 7 Sept 2024
Amount
Demolition of plain cement concrete (unreinforced) in ground floors and pavings exc 15cm thickness ( below or above gd level) complete all as specified and as directed.
Excavating in post holes (or similar holes) each n.exc. 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/ dense soil all as specified and as directed.
Material and labour plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate ) as in foundations, filling and mass-concrete all as specified and as directed.
Supply and fix steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 4923-1968 Grade St-240 for square or rectangular tube complete all as specified and as directed.
Supply and fix mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, Tee, angle channel or flat sections) including distance pieces, cleats etc.(Fe-410-W(Gde E-250)Quality-A) complete all as specified and as directed.
Supply and fix plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (Fe-410W, Gde E-165, Qlty-A) including necessary cutting in wall complete all as per specified and as directed.
Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated/tile pattern steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Material and labour plain cement concrete100mm thick type B-1, 1:2:4 (20mm graded aggregate) finished surface even and smooth without using extra cement complete all as specified and as directed.
Forming construction joint 30mm deep x 10mm wide filled with sealing compound - Grade 'B' complete all as specified and as directed.
Material and labour rendering 15mm thick brick or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth complete all as specified and as directed.
Material and labour preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
Supply and fixing framed work such as grills, gratings, etc..(fixed to wall/floor with anchor fasteners) with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed.
Material and labour for preparation of old decorated surfaces and applying one coat of acrylic emulsion (interior grade) on wall all as specified and as per manufactuers instructions all as specified and as directed.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard and dense soil all as specified and as directed.Note ;- a) prior approval of station HQ is to be obtained to avoid loss of other co existing utility services b)The excavation has to be done manually only.
Returing and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point.
Supply and spreading riddled earth for cushioning of the UG cable in trenches all as specified and as directed.
Supply and laying PCC unreinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete all as specified and as directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volts grade with aluminium conductors of size 240 sqmm 3.5 core complete all as specified and as directed.
All as per item no. 21 here in before but size of 10 sqmm 4.0 core complete all as specified and directed.
Material and labour for cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.3 Mtr and depth 0.5 Mtr all as directed and making good the road/hard using PCC as required at site to match with the existing surface all as specified and directed by Engr-in-charge.( NOTE: The hand driller/ breaker machine diamond cutter will be used all as directed by Engr-in-charge with prior permission.)
Material and labour for supply and fix of GI tubing light grade 80 mm nominal dia including taking down in trench/road/pole for cable protection complete all as specified and directed and as directed.
All as per item no.24 here in before but size of 32 mm nominal dia
Material and labour for supply , installation ,testing and commissioning of LT feeder pillar box out door type double door with canopy arrangement ,floor mounted free standing, dust and vermin proof fabricated out of 3.15 mm thick sheet outside and internal compartment with not less than 2 mm thickness CRCA sheet of suitable size duly pretreated in seven tank process for degreasing, de- rusting and phosphate primer power coated then painted with final coat of epoxy based power coat.Panel Size should not be less than 1m x 1m x 0.6m. panel shall be having front and rear opening for installation of separate cable alleys with proper locking arrangement with busbar chamber and switch gear compartment, Provision for cable alleys to be provided and bottom cable entry for incoming and outgoing cable. A clear space of 400 mm to be kept from floor level for switch gear compartment using mounting stand. Extended bus bar links/terminals to be provided for heat dissipation suitable size knockout holes for cable glands shall be provided. Paint shall be epoxy based approved shade of colour and make size of panel duly mentioned the size of each componet switch gear layout drawing shall be submitted for the approval of GE through Engr- In -Charge before ordering the item. The panel shall dully supported on angle iron of size 40x40x4mm thick . Panel shall be sutiable to accommodate and including the following accessories:-
Item No 26 Continued (a) Bus bar chamber (4 nos TP& N 320 amps rating ) (Aluminium bus bar ) set 01 ( with proper colour code) (b) Phase indicator lamp assy -03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper color code. (d) Digital multi function meter to measure current, voltage , power factor etc-01 with connected CT's of suitable size panel should have separate chamber and suitable size of aluminuim bus bar extension for connecting cable including following switchgears and its accessories. (i) Incomer MCCB 4 pole 200A -01 No (ii) MCCB 4 pole 63A-04 Nos,(iii) MCB TPN 32A -02 Nos Note: a) Panels shall be procured from firms having CPRI approval certificate and as approved by GE. GA drawings shall be submitted for approval of GE. b) Incomer MCCB should have proper spreader extensions and enough space to connect 240 sqmm x 3.5core XLPE cable.
Material and labour for fixing single pole AC 240 Volts, 6 to32 Amps C-Series in DB complete with connection and testing complete all as specifed and as directed.
M&L colour code point wiring for one 3 pin socket outlet 15Amps,independent FRLS PVC insulated and unsheathed cable with 4 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC casing caping with suitable size, For 3 run FRLS 4 sqmm [Two run of 4 sqmm wire for the phase and neutral, One run 4 sqmm for earth wire] copper insulated wire connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint all directed at the site.
Note (i) : Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) PVC capping shall be of suitable size.
Material and labour for fixing sub main wiring using 4 runs of 10 sq mm FRLS ,IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 25mm dia medium grade surface on wall along with 1 runs of 10 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and as directed. Note: Five runs of copper conductor and one run of conduit shall be measured as one unit.
Material and labour for fixing sub main wiring using 2 runs of 4 sq mm FRLS ,IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 20mm dia medium grade surface on wall along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and as directed. Note: Three runs of copper conductor and one run of PVC conduit shall be measured as one unit.
Material and labour for fixing MCB tripple pole & neutral AC 415 Volts, 50 Hz , C series 10 kA breaking capacity,40/ 63 Amps complete all as specified and as directed.
M&L for fixing MCB DB SPN 240V double door outdoor type, 12 way with bush bar of appropriate current carrying capacity, neutral link, earth bar and din rail including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and as directed.
Material and labour for fixing Switch socket combination modular type, 15Amps with 3 module PVC box and 3 modular cover plate with 15A switch and 15A socket and as specified and as directed.
Material and labour for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground(earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal GL, connected to and including galvanized earth lead Strip of size 20mmx3mm upto 7.5 m distance and connected by means of bolts,nuts,checknuts and washers of galvanized iron and including 15 mm dia medium grade GI pipe including excavation, earth work in any strata, charcoal, salt and pcc chamber, RCC 40 mm thick cover complete , testing and connecting up.complete all as shown in electrical plate No 3 of schedule Part-I and all as specified and as directed.
Supply and fix in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as 20 X 3mm copper strip. All as specified and as directed.
Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
Supply and fix powder coated aluminium anodised aluminium door shutters (minimum thickness of powder coating 50 micron) , aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed
Supply and fix 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane.
Material and labour 9 mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws/rubber beading to aluminium frame work complete all as specifiedand as directed.
Supply and fix door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed - Aluminium (extruded section) body.
Supply and fix 150 mm long Aluminium anodised, barrel tower bolts of ex truded section and fixed.
Supply and fix floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor - Overall length of cover plate - 140mm
Supply and fix Mortice lock, vertical type, size 100 mm - Mild steel - 4 Levers.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets -
Supply and fix anodised aluminium snap grid frame work for false ceiling all as specified - Size of grid 605 x 605mm.
Supply and fix hangers 6 mm dia. G.I. (upto 1200/2400 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed - Size of grid 605 x 605mm.
Material and labour 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws - 4mm thick -
Material and labour for preparation of new board ceiling surfaces and applying two coats of oil bound distember / acrylic emulsion over a coat of alkali resistant primer.
Material and labour for complete removal of existing surface by scraping of walls including cornices/ pillars etc. by brooming down and applying two coats of acrylic emulsion paint interior grade (Apcolite of Asian paints or equivalent make) over a coat of emulsion primer over a coat of wall putty of uniform finish complete all as specified and as directed.
Material and labour laying and pasting of Bituminous strip of width 10 cm of Make : 3M, BASF, Dr.Fixit, Forsroc or equivalent on joints of galvalume sheet & RCC surfaces including cleaning of existing surfaces all as specified and as directed.
Material and labour for sealing all the joints in sadharly stone with PU sealent of Make : Forsroc, McCoy Soudal or equivalent including cleaning of existing surfaces all as specified and as directed.
Material and labour for sealing of screw holes in roofing sheets with PU sealent of Make : Forsroc, McCoy Soudal or equivalent including cleaning of existing surfaces all as specified and as directed.
Taking down cement or cement lime plaster of any description including raking out joints, hacking for key and scrubbing down with water all as specified and as directed.
Material and labour 10mm thick rendering in CM 1:6 on wall surface surfaces finished even and smooth without using extra cement in patches complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete including fittings such as switches ceiling roses, pendent, regulators, sockets, MCB/ MCCB/ MCB DB/ earth plug and socket etc and making good matching to the existing colour to the disturbed surface.
Material and labour in replacement of old unserviceable sub main wiring using 4 runs of 4 sq mm FRLS ,IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 25mm dia medium grade surface on wall along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly, Including taking down exsting u/s wiring and including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and as directed.
Material and labour color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit of suitable size , modular cover plate with frame (inner /outer plate) for mounting switches sockets etc including FRLS 1.5sqmm earth wire copper insulated wire connected earth dolly a in any length as per all as specified directed by Engr-In-Charge for the following:-
One Light /fan point control by one switch.
One 3 pin socket outlet 5Amps on the Independent board.
All as per item No.57 here in before but in PVC pvc casing and caping of suitable size
One 3 pin socket outlet 5Amps on the Independent board.
M&L color code point wiring FRLS PVC insulated and unsheathed cable with 2.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit of suitable size , modular cover plate with frame (inner /outer plate) for mounting switches sockets etc including FRLS 2.5sqmm earth wire copper insulated wire connected earth dolly a in any length as per all as specified and as directed for the following:-
One 3 pin socket outlet 16Amps on the Independent board.
All as per item No.59 here in before but in PVC casing and caping of suitable size
One 3 pin socket outlet 16Amps on the Independent board.
Taking down and refixing carefully existing Smoke detectore / Sense complete all as specified directed by Engr-In-Charge, Note; Contractor has to do dismantling work after commencement of B/R work and refix after completion of B/R work as specified and as directed by Engr-In-charge detectore before B/R work and after reinstalling.
Taking down the ceiling fan, disconnecting the electrical connection,removing the Ceiling fan blades for storage,and refixing it after the completion of B/R work, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for painting of ceiling fans 1200 mm sweep complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
Material and labour for dismantling / opening the ceiling fan of 1200/1400 mm sweep of any make removing the old defective winding carefully cleaning the inner parts and re-winding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specifed and as directed.
Material and labour of bearing of suitable size for the ceiling fan of 1200/1400 mm including greasing re-assembling complete all as specified and as directed.
Supply and fix fan regulator electronic step up type 100/120 Watt AC 230 watts including taking down the unserviceable items complete all as specified and as directed.
Material and labour for removing old unserviceable fan capacitor and material and labour for fixing new capacitor 2.5mfd 440Volts of suitable make and size testing the fan Including taking down existing u/s capacitor all PVC Casing capping complete all as specified and as directed.
Supply and fix in replacement Recess full lit luminaire with glare free uniform illumination with longer life and less maintenance 36 W (2 ' x 2 ') in MS housing with opal diffuser with output lumen ≥ 110 lumen/watts,, Luminous efficacy ≥ 100/watt, CCT > 5500 k,CRI ≥ 80,Power factor ≥ 0. 95,THD ≤ 10 with all accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/ connection terminals.Including taking down existing u/s 36 W (2 ' x 2 ') Light and including aluminium frame for fitting the same. Make : Crompton Polaris NIO I-II LCTLRNE-36-FO-CDL or equivalent in Philips/Wipro/Havells/Bajaj
Supply and fixing non-metallic 25 mm PVC casing capping conduit exclusive of boxes (junction/erminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hoocks etc and Including taking down exstinng conduit all as specified and as directed.
Palace constructions (BID ID -3101016)
KDR CONSTRUCTION (BID ID -3104571)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .