Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.0 LAccepted-Finance 25 PRATAP COMPLEX GULAB SINGH MARG JAMMU | 1 | Accepted-Finance OK | |
| 2 | 2₹2.1 L+₹10,850 (5.45%)Accepted-Finance BHAGWATI NAGAR JAMMU | 2 | Accepted-Finance OK | |
| 3 | 3₹2.3 L+₹28,800 (14.5%)Accepted-Finance BHAGWATI NAGAR JAMMU | 3 | Accepted-Finance OK | |
| 4 | Rejected-Technical | - | Rejected-Technical In complete documrnts |
Tender Value
Refer Docs
Closing Date
25 Jul 2022, 4:00 pmClosed
Executive Engineer
Executive Engineer PHE Mechanical Division Rajouri
Repairing of different capacities of Transformer/Voltage stabilizer and replacement of electrical equipment installed at various pumping stations of section Kalakote of PHE mechanical subdivision Nowshera.
2022_PHE_180028_1
e-NIT PHE/MDR/48 of 2022-23 DATED 19-07-2022
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Rajouri
Please refer Tender documents.
3 documents required · 3 mandatory
₹250
Executive Engineer PHE Mechanical Division Rajouri
Yes
22 Aug 2022
20 Jul 2022
26 Jul 2022
20 Jul 2022
25 Jul 2022
20 Jul 2022
Amount
Repairing of 100KVA transformer installed at pumping station New Source Kalakote by way of dismantling of transformer extracting of all the damaged coils, cleaning and flushing of the oil tank by using chemical to all the carbon deposit. Providing & fitting of 4 nos HV coils. Providing & fitting of 01 no LV coils. Reconditioning of 2 other LV coils. Providing fitting of 2 nos LV bushes 1 no HV bushes with metal parts, Providing & fitting gasket, nut /bolts, tapes and sundry items. Heat treatment of transformer oil and P/Filling of fresh 40 ltr. transformer oil. Assembling of transformer and testing on full load. Complete job includes cost of material, labour charges (skilled/unskilled) and carriage/shifting charges.
Repairing of 100KVA transformer installed at pumping station Tattapani by way of dismantling of transformer extracting of all the damaged coils , cleaning and flushing of the oil tank by using chemical to all the carbon deposit. Providing & fitting of 4 nos HV coils. Reconditioning of 3 LV coils. Providing fitting of 1 nos LV bushes 1 no HV bushes with metal parts. Providing & fitting gasket, nut /bolts, tapes and sundry items. Heat treatment of transformer oil and P/Filling 35 ltr. fresh transformer oil. Assembling of transformer and testing on full load. Complete job includes cost of material, labour charges (skilled/unskilled) and carriage/shifting charges.
Providing & fitting of 15 HP submersible automatic control panel at pumping station Dharamsaal New. Job involves removing the damaged/burnt out submersible control panel from the panel board after disconnecting the electrical cables. Providing of new submersible control panel & fitting it on the panel board with the help of fasteners. Reconnecting the electrical cables to the panel after cutting their overheated /damaged ends and thimbling them properly and testing it on full load job also involves calibration of its overload protection according to its load. Complete job includes the cost of material, labour charges and carriage charges at site.
Providing & fitting of 185 mm sq. aluminium cable 3.5 core (20 mtr. Approx.) from LT pole to main Switch at Dug Well Chainpur and Pumping station Maloorian Stage-Ist. Job involves removing the damaged/burnt out cable from LT pole. Connecting of aluminium cable-185mm sq. 3.5 core from LT pole to 200 Amp 415 V main switch fitted on the panel board with proper thimbling duly crimpled by using crimpling tool & proper insulation. Complete job includes the cost of material, labour charges and carriage charges at site.
Providing & fitting of 200 Amp capacity main switch and 50 HP star delta oil immersed double contact starter at Pumping station Dadoach. Job involves removing the damaged/burnt out main switch and starter from panel board. Providing of new 200 ampere 415 V double break HRC Type main switch along with HRC fuses of suitable capacity and 50 HP starter fitting it on the panel board with the help of fasteners. Connecting the electrical cables to main switch and starter after proper thimbling. Complete job includes the cost of material, labour charges and carriage charges at site.
Repairing of 100 KVA 3 phase manually operated volt. Stabilizer of Pumping station. Mihari Kalakote. The job includes disconnecting of incoming and outgoing power cables. Dismantling of the stabilizer by lifting of transformer assembly from the oil tank with the help of chain pulley block and manual labour. Complete rewinding of 2 No. main coils by using superior quality of material, replacement of 2 Nos. rotary switch complete in all respects. Repairing and servicing of other regulators, assembling the voltage stabilizer. Providing and filling 42 ltrs of fresh T oil to top up the level. Making of power connections with proper thimbling. Complete job includes cost of material, labour charges (skilled/unskilled) and carriage/shifting charges.
PERFECT ELECTRICAL WORKS
M/S FASTTRACK ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .