| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹37.8 L+₹3.4 L (9.88%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹43.9 L+₹9.5 L (27.7%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Feb 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF AMB-59/2019-20 MANNING AND OPERATION OF PUMP SETS, DG SETS, STP, REPAIRS TO WATER SUPPLY LINES, UG SUMPS, SWTs, ELECTRICAL INSTALLATIONS, INTERNAL ELECTRIFICATION, CEILING FANS, COOLING APPLIANCES, DESERT COOLERS, EARTHING PITS, LT PANELS,
2020_MES_313140_1
GE AF/AMB-59/2019-20
Open Tender
Civil Works
Item Rate
330 days
GE AF AMBALA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹80,000
Yes
26 Feb 2020
9 Jan 2020
7 Feb 2020
9 Jan 2020
5 Feb 2020
24 Jan 2020
Amount
Manning & Operation of the following water supply installations and STPs by providing 01 FGM each in 02 (two) shifts (each shift of 8hours) in each installation on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge: (a) Submersible pump set of capacity upto 30HP electric driven complete with LT panel, starter and sluice valves, etc. complete for boosting/shifting the water in OH reservoir, etc. (b) Operation of chloronome plant and bleaching dozer of any type as per requirement while pumping the water to reservoir (c) Operation of standby DG set installed in the same pump house for standby supply to the pump set as required basis on main electric supply failure, etc. (d) Operation of sewage treatment plant including all items viz. submersible motor, boiler motor through electric panel complete
Manning & Operation of sub-station with DG set 160kVA including attending internal and external electric complaints of HT/LT electrification including street lights, perimeter lights, etc. by providing 01 (one) qualified electrician, in 03 (three) shifts of 8hours each (round the clock 24hrsx3 shifts = 3 electricians) on all days including Sundays and holidays for technical area at 260SU complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation for sub-station with DG set 160kVA including attending internal and external electric complaints of HT/LT electrification, including street lights, perimeter lights, etc. by providing 01 (one) mate working as helper each in 01 (one) shift of 8hours on all days including Sundays and holidays for technical area at 260SU complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of sub-station with DG sets of various capacities at various locations by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrsx3 shifts = 3 FGMs) on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Notes for serial item Nos. 1 to 4: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) 'NIL'or 'Zero' quoting of rates against any items will be treated as 'Non Bonafide'. (iii) The rate quoted shall not be less than minimum fair wages as notified by the Government of India / State Government / Local bodies / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable. In case, the rates quoted by the bidder are less than the minimum fair wages as notified by the Government of India / State Government / Local body / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, his tender will be treated as 'NON BONAFIDE' and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only.
(iv) The minimum wages as derivied by the Deartment including all statutory provision such as ESIC, Bonus, GST, taxes, etc. except the Contractor's profit for skilled person works out to Rs. 705/-per person per shift and for un-skilled person Rs. 552/- per person per shift (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase will be passed over to the workers
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc.not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc.not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
M&L for plain cement concrete type C-1,1:3:6 (using 20mm graded stone aggregates) in copings to poles, padding, PCC bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, etc. including necessary formwork complete all as specified and as directed
S&F cable route/path indicator made out of 300x300x1.6mm thick MSl sheet duly rivetted and welded to 600mm long MS angle iron of size 30x30x5mm and duly embedded in PCC 1:3:6 type C-2 block of size 300x300x300mm including necessary excavation and earthwork and painting all exposed steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and writing size and voltage of cables complete all as specified and as directed
Supplying, laying / fixing, testing and commissioning of electric cable 1100V grade aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
3.5 core 185sqmm
3.5 core 150sqmm
3.5 core 120sqmm
3.5 core 95sqmm
3.5 core 70sqmm
3.5 core 50sqmm
3.5 core 35sqmm
4 core 25sqmm
4 core 16sqmm
2 core 10sqmm
Supplying, laying / fixing, testing and commissioning of electric cable 11kV grade 3 core 95sqmm aluminium conductor XLPE insulated, galvanised steel armoured power cables conforming to IS-7098 (Part-I)-1988, XLPE insulation, earthed including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed Note: Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to PCC/steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
Supplying, erecting and fixing up in position steel tubular swaged pole overall height 9m type 410 SP-31 with cast iron base plate, pole cap, finial taper plug bolt, nut, washer, etc. including shop coat of red oxide primer, 3No. bent/strips with post office red/yellow colour (300mm wide each) synthetic enamel paint at a distance 300mm from plinth block and marking pole No. with black synthetic enamel paint, tarring one coat of steel surfaces embedded in concrete complete all as specified and as directed
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
S&F MS galvanised chain link fencing, any size or type including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as specified and as directed
S&F angle iron posts & struts in fencing including cutting top to shape, drilling holes, notching for wire including all necessary drilling bolts or rivetting & similar works conforming to Fe-290 grade E-165 (for securing chain link fencing, etc.) complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in sub-bases, filling, platforms, etc. complete all as specified and as directed
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
M&L for cleaning & utility servicing HT Vacuum Circuit Breaker (VCB), 11kV (outdoor type), 400/630Amp, 3 phase, checking of each moving parts, spring charging system, triping system, indication system, metering system, remote operation, closing & trip coil assembly and proper oiling, greasing and proper adjustment of trip bars, closing bar complete with the following testings complete all as specified and as directed (i) ON/OFF testing in local and remote position (ii) Spring charge system (iii) Tripping test in overload and earth fault position by external current injecting Kit on both primary & secondary sides (iv) Meggar testing between phase to phase and phase to earth in ON / OFF position both (v) Calibration of earth fault / over current relay Notes: (a) Tests shall be carried out through competent labs / test houses as approved by the GE (b) All the test reports shall be submitted to the Engineer-in-charge and shall be made part of RAR / FB
S&F half gear assembly suitable for HT VCB, operating on 24/110Volt system and testing complete all as specified and as directed
Supply, fixing, connecting and testing spring charging motor (universal motor) for outdoor type, 11kV, VCB, operated on 230V AC/ DC, with charging time less than 15seconds of approved rating complete all as specified and as directed
S&F shunt trip coil assembly suitable for HT, OCB/ VCB, operating on 24/110V system and testing complete all as specified and as directed
S&F closing coil operated on 110/24V system suitable for working of relay of HT OCB / VCB complete all as specified and as directed
S&F under voltage coil assembly suitable for HT OCB/ VCB operated on 110/24V system and testing complete all as specified and as directed
S&F in repairs indication lamp (LED type) Red / Yellow / Green colour suitable for 110V AC / 110V DC / 30V DC (as required at site) complete all as specified and as directed
S&F electric heater suitable for VCB as per existing size and capacity complete all as specified and as directed
S&F charging gear box for 11kV, VCB, operated on 230/24Volt AC/DC as per approved rating, size, type, material shall be synchronised with the present system as per existing complete all as specified and as directed
S&F vacuum interprator set (stud/non-stud type) for 11kV VCB, as per existing size and type and material synchronised with the present system complete all as specified and as directed
S&F bus bar insulator for 11kV VCB as per existing size and type complete all as specified and as directed
Supply only of insulation support set panel for 11kV VCB all as per existing size and type complete all as specified and as directed
S&F insulating sleeves of HT VCB of capacity 630A 11kV resin cast insulator of existing size and type complete all as specified and as directed
M&L for switch air break gang operated, tripple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200Amps 11000V grade with 9 insulators including 25mm dia GI medium grade pipe, supports worked from ground level vertically operated including taking down old unserviceable switch from existing place and disposing off complete all as specified and as directed
M&L for carrying out tests for locating faults in LT cable of any size with the help of fault locator machines, etc. complete all as specified and as directed
S&F lightening arrester, expulsion type, 65kA discharge capacity transmission class, suitable for 11kV system including staging as required complete all as specified and as directed
S&F in repairs MCCB 3 pole 3 Phase 415V 63Amps 25kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 3 pole 3 Phase 415V 100Amps 25kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 160Amps 36kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 200Amps 36kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 250Amps 50kA adjustable thermal release type complete all as specified and as directed
M&L for taking out burnt HT/LT winding from transformers, etc. cleaning all the limbs, replacing with new winding with super enemelled copper wire of same specification, varnishing by vacuum impregnating, replacing insulating material, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs single phase preventer VSP 3, 415Volt, 50Hz complete all as specified and as directed
S&F in repairs LT/HT side bushes of existing size, specifications and make of equipment complete all as specified and as directed
S&F in repairs HT/LT bushing rubber (ring) gaskets set of transformer complete all as specified and as directed
S&F in repairs transformer top gaskets (cork sheet) set of transformer complete all as specified and as directed
S&F in replacement silica gel of existing specification complete all as specified and as directed
Supply & filling the transformer oil (as per IS 339-1989) breaking down capacity more than 40kV to replace/topping up low breaking down capacity oil in at site including filteration & dehyderation complete all as specified and as directed
M&L for filteration, dehyderation and checking of transformer oil including necessary connection, testing, etc. on refilling / re-pouring into equipments complete all as specified and as directed
M&L for cleaning and utility servicing of transformer upto 200kVA including checking and tightning of all HT and LT connections, plugging of oil leakage, adjustment of tapsm, change over switches, etc. and restoring overall functionality complete all as specified and as directed Notes: (a) Servicing shall be carried out through authorised agents as approved and as dircted by the Engineer-in-charge
M&L for disconnecting, dismantling and removing transformer of capacity upto 200kVA, any make / any type (indoor/outdoor) from any locations / site, transporting the same to workshop, opening, draining out oil, taking out core assembly in the presence of JE/Engineer-in-Charge and estimating the repairs of damaged parts, cleaning /washing of tank removing the dirt sludge and sticky materials from all parts of the transformer including core tank and cooling tubes, removal of damaged parts, re-assembling after replacement of damaged parts of the transformer after repairs including preparation of old surfaces and painting with two coats of synthetic enamel paint (grey tint) on entire outer surfaces, writing trnasformer No. etc. making all connections and filling with fresh transformer oil and dehydration of oil by wax centrifuging and testing for all type of tests including reinstallation of transformer at site complete all as specified and as directed Note: Rate quoted shall be inclusive of cost of all de-installing, loading / unloading, carting, reinstalling, etc. to and fro from site to workshop all necessary T&P, etc. complete
S&F synthetic insulating mat of size 2x1m x 25mm thick suitable for HT 11000V imnstallation including bolting, etc. complete all as specified and as directed
M&L for disconnecting and taking out capacitor bank panel from foundation, in any location, removing to store / workshop for repair works including testing and calibration of APFC relay, repairs to on delay timer, repair/replacement to indicating lamps, repair to all necessary internal wiring of panel with required size copper lead along with lugs, repairs to power capacitor, repair/replacement of 3 position spring return switch with NO & NC elements, repair to ON Delay suitable for mounting on contactors timer and reinstalling panel in its original position including making good the disturbed foundation / platform complete all as specified and as directed Note: Rate quoted shall be inclusive of all necessary T&P, loading / unloading, carting to and fro to workshop, etc.
S&F in repairs power capacitor, power quality heavy duty 20kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power capacitor, power quality heavy duty 10kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power factor controler PFC-14 relay, single phase, 230V, 50Hz complete all as specified and as directed
S&F in repairs power contactor 3 pole with AC/DC coil for 20kVAR power capacitor including all connections and testing complete all as specified and as directed
S&F in repairs power contactor 3 pole with AC/DC coil for 10kVAR power capacitor including all connections and testing complete all as specified and as directed
M&L for taking down old street light / security light / high mast light / guard post light fittings and refixing after necessary repairs including cleaning of perplex covers, etc., tightening of loose connections on poles / walls, and replacing and dead bulb / tube rod, worn out minor parts, etc. and making the fitting functional complete all as specified and as directed Note: Minor parts, bulb/tube rod shall be measured and paid separately under respective items herein
Supply only open construction ballast 150W suitable for HPSV/MH fitting, 220/240V, 50Hz complete all as specified and as directed
Supply only open construction ballast 400W luminaire type suitable for HPSV/MH fitting, 220/240V, 50Hz complete all as specified and as directed
Supply only HPSV lamp 150W tubular, 240V complete all as specified and as directed
Supply only HPSV lamp 400W tubular, 240V complete all as specified and as directed
Supply only lamp holder suitable for 150W SV/MH lamp, 240V 520Hz complete all as specified and as directed
Supply only Ignitors for 70 to 250W for SON/MH lamp, 240V, 50Hz complete all as specified and as directed
Supply only capacitors 20MFD + 5%, 240V, AC, 50Hz complete all as specified and as directed
S&F heavy duty PVC earth pit cover (bucket type) for existing chemical earthing incliding cap complete all as specified and as directed
S&F FRP looping box of size 250x150x105mm with suitable 100A bus bar, 230V, 50Hz and porcelain connector with MCB SP 6Amps, 10kA fixed with and including requisite clamps, nuts, bolts, washers, etc. mounted on poles/ walls, etc. and taking down and disposing off old box complete all as specified and as directed
M&L for bands, straps, supports or stays including bolts, if required hooks (stay), hand made sliding bolts, clamps, hold fasts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 grade E-165 including duly painting with two coats of synthetic enamel paint complete all as specified and as directed
S&F brass earth test points of existing size with nuts and bolts du;y embedded at existing location complete all as specified and as directed
M&L for removing / scrapping of old worn out paint from MS fencing posts, MS flats, welded mesh, etc. by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
S&F 1.5m long 40mm bore light grade GI pipe bracket duly cut to size and bent to shape required duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, including 2Nos. FI 50x6mm clamps as required to fix on concrete / steel poles and taking down and disposing off old unserviceable brackets complete all as specified and as directed
S&F LED street light fitting, 45W, 230V, 50HZ, suitable for operation over voltage range of 140V to 270V, duly housed in pressure die cast aluminium housing, compressing of LED with individual optical lens, electronic driver with IP 66 protection and impact reistance of IK 07, including connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting and taking down and disposing off old unserviceable fitting complete all as specified and as directed
S&F flood swiveling type light fittings with switch gear, control gear unit, with and including 400W MH lamp with all fixing accessories, positioning, drilling, bolting, etc. and connecting up complete all as specified and as directed
Servicing of DG set of capacity 15 to 40kVA 3 phase at site including, cleaning of diesel tank internally thoroughly with water and air pressure, removing the sludge from the tank, opening of oil chamber cover, draining out used engine oil, cleaning the chamber throughly internally and refixing the chamber cover, taking off and replacing worn out / unserviceable parts and making DG set functional including all testing on full load, etc. complete all as specified and as directed
Servicing of DG set of capacity 63kVA 3 phase at site including, cleaning of diesel tank internally thoroughly with water and air pressure, removing the sludge from the tank, opening of oil chamber cover, draining out used engine oil, cleaning the chamber throughly internally and refixing the chamber cover, taking off and replacing worn out / unserviceable parts and making DG set functional including all testing on full load, etc. complete all as specified and as directed
Notes for serial item Nos. 90 & 91: (i) Serviceable parts shall be fixed in position and replacement of unserviceable parts with new parts viz. nuts, bolts, washers, thimbles, wire, fuse, gasket, locking nuts, small springs, `O’ rings, screws, packing material, studs shall be deemed to be included in quoted rate. (ii) Other new replaced parts shall be measured and paid for separately under respective items of BOQ hereinafter (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump with kerosene oil (iii) Fresh engine oil if oil is replaced shall be supplied by the Contractor and shall be measured and paid separately under respective item of BOQ (iv) Rates for replacing components / filling of oil shall be deemed to be included in the quoted rate
Supply and pouring fresh coolant
Supply and pouring fresh lubricant engine oil
Replacement of lubricant oil filter element (set of two) for DG set of capacity 15 to 40kVA
Replacement of fuel filter element (set of two) for DG set of capacity 15 to 40kVA
Replacement of by-pass filter element for DG set of capacity 15 to 40kVA
Replacement of air cleaner filter element set for DG set of capacity 15 to 40kVA
Replacement of fan belt set for DG set of capacity 15 to 40kVA
Replacement of radiator hose pipe of suitable size for DG set of capacity 15 to 40kVA
Replacement of lubricant oil filter element (set of two) for DG set of capacity 63kVA
Replacement of fuel filter element (set of two) for DG set of capacity 63kVA
Replacement of by-pass filter element for DG set of capacity 63kVA
Replacement of air cleaner filter element set for DG set of capacity 63kVA
Replacement of fan belt set for DG set of capacity 63kVA
Replacement of radiator hose pipe of suitable size for DG set of capacity 63kVA
Replacement of starting switch / self starter 12/24V suitable for 40/63kVA DG sets
Replacement of pinion gear suitable for 40/63kVA DG sets of existing size, type and make
Replacement of armature suitable for 40/63kVA DG sets of existing size, type and make
S&F stopper alongwith relay for 40kVA DG set all as per existing type and size complete all as specified and as directed
S&F relay iOPS-0404D-9/M-7/Y15/N for 40kVA DG set all as per existing type and size complete all as specified and as directed
S&F relay relay of 8 pin suitable for 40kVA DG set all as per existing type and size complete all as specified and as directed
M&L for checking/servicing of DG set battery 12V 92/180AH by cleaning the battery terminals with hot water and applying petrolium jelly over terminals, checking water level and topping up with distilled water and testing functionality complete all as specified and as directed Note: Replaced parts / components will be measured and paid separatly under respective items herein
Supply only heavy duty brass battery terminals of existing type, size and make including nuts/bolts
Supply only battery cable 70sqmm multi-stranded copper conductor of existing core
Supply only distilled water for batteries in sealed bottles
M&L for taking out radiator assembly from DG sets, of capacity 40/63kVA, carefully and servicing, cleaning the same internally as well as externally with chemical, cleaning the fins throughly, replacing worn out spares and refixing the same at its original position and testing complete all as specified and as directed Note: Spares / parts replaced will be measured and paid under relevant items herein
S&F in repairs battery charger 240V 50Hz charging range 6 to 24volt with trickle / boost charging mode complete all as specified and as directed
M&L for servicing self starter of capacity 12V suitable for 15 to 63kVA DG set, reparing the same by rewinding armature, field coil, replacing the pinion, carbon brush and fixing at its original position and testing on completion complete all as specified and as directed
M&L for taking down unserviceable alternator from engine of DG set of any capacity for servicing and replacement of carbon brushes, PCB and refixing after servicing of unserviceable parts and testing for functionality complete all as specified and as directed
S&F fly wheel ring suitable for DG sets 40/63kVA including dismantling and taking out unserviceable fly wheel ring by separating alternator and diesel engine and testing on completion complete all as specified and as directed
M&L for servicing and repairing AMF panel for 63kVA DG set at site including changing of contactor (2NO+2NC BCH15 T22 BCH 15) and relay (MC320KE32 MD DMD control relay) and all other minor unserviceable spares/items and making the panel functional complete all as specified and as directed
S&F copper thimbles 10 to 95sqmm size of existing type and make complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 11kV earthed grade cable heat shrink type joint with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor/outdoor straight through / end termination type, for 1.1kV earthed grade cable heat shrink type joint with jointing material and accessories suitable for 3.5 core, 25 to 70mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor/outdoor straight through / end termination type, for 1.1kV earthed grade cable heat shrink type joint with jointing material and accessories suitable for 3.5 core, 95 to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for earthing with galvanised steel earth wire electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth wire 4sqmm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
M&L for earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth strip of size 32x6mm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for item Nos. 129 & 130: (i) The cost of GI earth continuity conductor/wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item
Supply, installation, testing and commissioning maintenance free tripod chemical earthing system consisting of 3Nos. of solid copper earth rod of 10ft length, 17.2mm dia and 3m long on outer surface having 250microns (minimum thickness) with exothermically jointed copper bus bar of 150x25x3mm for long lasting and connecting each copper rod and the exothemically jointed bus bar, both CPRI tested on at leat 25kA fault current ensuring high current carrying capacity of the system and earth rod should be certified by laboratories confirming to comply with UL 467 international standards grounding and bonding equipment and each rod should be used with minimum 50kg earth enhancing compund that should be ROHS tested and have passed leaching sulpher, corrosion, resisitivity test shall be less than 0.05lhm mtr and international standard for earth enhancement compound by NABL acredited laboratory and each rod should be interconnected with 8mm dia copper clad steel conductor at the distance of 3m to make a shape of traingle with top of the bore finished with 40mm thick PCC in 1:2:4 type B-1, 75mm thick PCC in 1:4:8 type D-2 and back fill/JAM compund shall be covered with advanced polymer pit cover of 30x30mm size including taking out old unserviceable earthing complete all as specified and as directed
Notes: (i) The earthing shall comply to IS 3043, UL 467, BS/EN50164-7 (ii) The earth resistance shall be less than 01Ohm. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect (iii) To obtain earth resistance less than 01Ohm, if a combination two or more earthings are to be inter-connected or the length of the electrode/s is/are to be increased it shall be measured and paid as one earthing only (iv) Testing of earth shall be carried out in presence of Departmental rep and requisite test reports shall be submitted (v) Cost of all excavation & earthwork required shall be deemed to be included in the quoted rate
Supply and filling in existing earth pits bentonite base earthing enhancement back fill compound complying to latest Indian Standards complete all as specified and as directed
Supply and filling in existing earth pits graphite base earthing enhancement back fill compound complying to latest Indian Standards complete all as specified and as directed
Taking up or down steel water tubing and connections and disposing off, etc. complete all as specified and as directed for the following bores:
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches complete all as specified and as directed of the following bores:
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
M&L in replacement for CI specials for spigot and socketed pipes, such as tee, bends, collar, tapers, adopter, tail pieces, etc. any type, size and radius & shape as per IS specification size up to 200mm dia complete all as specified and as directed Note: Excavation / earthwork and lead joints shall be measured and paid separately under respective items herein
M&L for rubber gasket (tyton) joints for 100mm bore cast iron pipes including jointing material like spun yarn, etc. complete all as specified and as directed
M&L for rubber gasket (tyton) for 150mm bore cast iron pipes including jointing material like spun yarn, etc. complete all as specified and as directed
M&L for run lead joints for 100mm bore cast iron pipes including jointing material like spun yarn, etc. complete all as specified and as directed
M&L for run lead joints for 150mm bore cast iron pipes including jointing material like spun yarn, etc. complete all as specified and as directed
S&F sluice valve cast iron body class PN 1.6 marked both ends fanged with brass spindle and brass check nuts with cast iron hand wheel including jointing material like rubber insulation sheet 3mm thick, bolts, nuts and fixed to pipe line, including testing on installation and taking out / down and disposing off old / unserviceable sluice valve complete all as specified and as directed of the following sizes:
150mm dia
100mm dia
S&F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, and earthwork in any type of soil or breaking/cutting into road/interlocking tiles/cement concrete, etc. and making good the disturbed surfaces complete all as specified and as directed of the following sizes:
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
M&L for arresting leakage in GI pipe lines of sizes 15 / 20 / 25mm bore by replacing with new pipes upto 1.5m long with necessary cutting, threading, cleaning, etc. including inserting of new fittings viz. nipples, unions, elbows, tee, sockets, bends, etc. as required complete all as specified and as directed
M&L for arresting leakage in CI pipe lines of sizes 80 / 100 / 150mm bore by replacing with new pipes upto 1.5m long with necessary cutting, threading, cleaning, etc. including inserting of new fittings viz. nipples, unions, elbows, tee, sockets, bends, etc. as required complete all as specified and as directed
M&L for potability testing by chemical analysis of water through NABL accredited and PPCB & CPCB authosied laboratories including all necessities viz. collecting of water from the source, suitably carting to and fro to Lab, etc. complete all as specified and as directed. Notes: (i) Testing shall comprise of all necessary analyis viz. pH value, colour, odour, taste, turbidity, total hardness, total alkalinity, iron, chloride, residual contents, fluoride, dissolved solids, sulphate, nitrate, total coliform, E coli, etc. and all other tests as stipulated in relevant IS. (ii) Test reports from the Lab shall be submitted in triplicate (iii) All requirements to get the sample tested shall be borne by the Contractor
Taking up cast iron water mains (including all fittings) with spigot and socketed ends and lead joints including burning out lead from joint and recovering lead and disposing off complete all as specified and as directed
100mm bore
150mm bore
M&L for CI pipes with socketed and spigot ends suitable for tyton joints centrifugally cast (spun) class LA conforming to IS:1536 cut to any length and laid in trenches including rubber gaskets joints complete all as specified and as directed of the following sizes: Note: Fittings shall be measured and paid separately under respective items herein
100mm bore
150mm bore
S&F in repairs closing/opening multi-pod valve upto 1.5inch filter as per existing type and capacity complete all as specified and as directed
M&L for taking down, carting submersible water pump set of capacity 35HP 3 Phase 415V from site to workshop, dismantling pump set, taking out burnt winding wire from 6"/8" dia motor and rewinding with suitable size PVC coated copper winding wire as per existing wieght and pattern, including all insulating material, repair/replacement of unserviceable parts required like sealing kit, O ring gasket water drain plug, sand guard, cable packing, cable gland ring, upper/lower bearing, adopter piece, motor key upper/lower flange, neck ring, bowl stud section case, hex bolt, circlip washer, motor/pump coupling, bowl stud, motor / pump bush, etc. and reassembling pump set, tesing and commissioning pump complete all as specified and as directed Note: Rate quoted shall be inclusive of cost of all de-installing, loading / unloading, carting, reinstalling, etc. to and fro from site to workshop
M&L for disconnecting and dismantling sewage pump and motor of capacity upto 5HP carefully for servicing, cleaning bearing/bush by cleaning solution and replacing unserviceable minor items like bearing, nut bolt & washers, etc. greasing of bearing, and all moving parts, cleaning of valve, RE-assembling and refixing in the original place, connecting up and testing for successful operation complete all as specified and as directed
M&L for disconnecting and dismantling filter feed pump and motor of capacity upto 5HP carefully, dismantling for servicing, cleaning the bearing/bush by cleaning solution and replacing unserviceable minor items like bearing, nutb bolt & washers, etc. greasing of bearing and all moving parts, cleaning of sewage pump, replacement of gasket and valve, re-assembling motor & pump and refixing in the original place, connceting up and testing for successful operation complete all as specified and as directed
M&L for cleaning of internal surfaces of RCC overhead tank of 75000 gallons capacity including staging to a height approx 18m by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed
M&L for desilting and cleaning of equilisation tank of STP by scrubing the surface with the help of coir brush, jute cloth and flushing out all accumulated mud/silt/scum in 260 SU AF Stn Patiala including cleaning of flow rotameter using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks, and applying two coats of lime wash to all internal surfaces and writing date of cleaning, etc. complete all as specified and as directed
M&L for desilting and cleaning of MBBR tank, tube settler tank, CCT tank, TWT tank of STP by scrubing the surface with the help of coir brush, jute cloth and flushing out all accumulated mud/silt/scum in 260 SU AF Stn Patiala including cleaning of flow rotameter using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks, and applying two coats of lime wash to all internal surfaces and writing date of cleaning, etc. complete all as specified and as directed
Supply only chlorination chemical highly efficient (high strength) calcium based granular disinfectant, more stable than chlorine gas, highly stable, in sealed container to check no sodium, iron/mercury/heavy metal contaminations, etc. complete all as specified Note: (i) Paid vouchers of calcium based granular disinfectant shall be submitted (ii) The calcium based granular disinfectant shall be brought at site/store in sealed plastic container of appropriate capacity / size asked (iii) The brand of chemical shall be as approved by the GE
Supply only sodium hypochloride complete all as specified Note: (i) Paid vouchers shall be submitted (ii) The calcium based granular disinfectant chemical shall be brought at site/store in sealed containers of appropriate capacity / size asked
S&F in repairs flange of size up 80mm bore pipe with 6/8 hole as per sample approved for pump at STP including valves as per existing size and type complete all as specified and as directed
M&L for FAB media as per existing shape, size and make including disposing off old unserviceable bed outside MD land including all necessary carting, etc. complete all as specified and directed.
S&F in repairs diffuser as per existing shape, size and make complete all as specified and as directed
M&L for disconnecting and dismantling blower of STPs of any size carefully for servicing by cleaning the bearing/bush with cleaining solution and greasing including replacing unserviceable items viz. nut bolt, washer, etc. re-assembling the blower unit and refixing in the original place, connecting up and testing for operation on installation complete all well as specified and as directed
S&F chlorination dozing pump of capacity 4LPH, maximum pressure 5.5kg/sqcm, stroke speed 100 duly fixed with suction/delivery pipes, plcaed and fixed at any location and testing on commissioing including disposing off old/unserviceable pump complete all as specified and as directed
M&L for draining out entire water from semi-underground static water tank 50000 gallons capacity, cleaning of all accumulated sand, sandy mud, insoluble particles, silt, etc. inside the tank, with the help of coir brush, jute cloth and flushing out/wiping off clean and applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. complete all as specified and as directed
M&L for supplying and filling activated carbon 800 ID including testing on completion for successful functioning and removing of old carbon any type & size from carbon filter bed of STP with all necessary lifting/carting/ loading /unloading, etc. complete all as specified and as directed
M&L for laying sand in filtering / media bed including cleaning off the tank bed and disposing off old sand bed outside MD land including all necessary lifting/carting/loading/unloading, etc. complete all as specified and as directed
M&L for construction of brick masonry valve pit chamber with 100mm thick foundation using PCC 1:3:6 (type C-2) using 40mm graded stone aggregates, 230mm thick brick masonry wall built in CM 1:6, 10mm thick internal and 15mm thick external plastering in CM 1:4, finished even and smooth without using extra cement and 6mm thick MS sheet cover including 40x40x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x6mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surfaces including excavation and earth work in any type of soil and disposal of surplus soil to a distance of not exceeding 50m, complete all as specified and as directed for the following sizes (internal dimensions) Note: The cost shall be inclusive of all items of work required for the execution and entire completion of this item and nothing extra shall be paid separately in any other items of BOQ
Taking down carefully batten type copper / alluminium point wiring including fittings such as light fittings, sockets, switches, ceiling roses, regulators, board outlets, etc., and disposing off including making good the disturbed surfaces with its original specifications complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed in walls / roofs / floors / ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one switch
One bell point controlled by one bell push
One switch socket outlet 3 pin 5Amps on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring complete with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed in walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly for 3 pin 15Amps switch socket power point on independent board complete all as specified and as directed
M&L for point wiring with 2 runs of 4sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories surface on walls / roofs / floors / ceiling etc. and including provision of 2.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for metal clad plug and socket 15A complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5amps, 240V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 6amps, 230V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 16amps, 230V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 5amps flush type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 6amps modular type, ISI marked, 230V complete all as specified and as directed
S&F socket outlet, multi-purpose, 3 pin, 16Amps, and 1 pin 6Amps, modular type, ISI marked, 230V controlled by one switch complete all as specified and as directed
S&F switch socket combination outlet, multi-purpose, 2 in 1, 3 pin, 5Amps, ISI marked, 240V controlled by one switch complete all as specified and as directed
S&F switch socket combination outlet, multi-purpose, 2 in 1, 3 pin, 15Amps, ISI marked, 240V controlled by one switch complete all as specified and as directed
S&F bell push flush button type, 5Amps, 240V complete all as specified and as directed
S&F bell push modular type, with cover plate, 6Amps, 230V complete all as specified and as directed
S&F PVC lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F bell buzzer, ding dong type, 240V, single pole complete all as specified and as directed
S&F electronic fan regulator, stepped type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F electronic fan regulator, stepped modular type (5 steps), 120W, 50Hz, 230V, ISI marked with cover plate duly connected up complete all as specified and as directed
S&F modular white cover plate with frame suitable for 2 modules ISI marked complete all as specified and as directed
S&F modular white cover plate with frame suitable for 3 modules ISI marked complete all as specified and as directed
S&F modular white cover plate with frame suitable for 6 modules ISI marked complete all as specified and as directed
S&F modular white cover plate with frame suitable for 12 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 2 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 3 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 6 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 12 modules ISI marked complete all as specified and as directed
M&L for sub-main wiring with two runs of 6sqmm, single core PVC insulated, heavy duty, ISI marked, FRLS, unsheathed cable, 1100V grade, multistranded copper conductor drawn through and including 25mm dia non-metallic rigid PVC conduit with conduit accessories concealed /fixed to walls / roofs / floors, etc. and one run of PVC insulated, heavy duty, ISI marked, unsheathed cable 1100V grade 4sqmm for earth continuity copper conductor including taking down of old submain wiring and making good the disturbed surfaces to match with the exisiting surfaces complete all as specified and as directed Note: 2 runs of 6sqmm and one run of 4sqmm conductor and one run of PVC conduit shall be measured as one length
M&L for sub-main wiring with two runs of 4sqmm, single core PVC insulated, heavy duty, ISI marked, FRLS, unsheathed cable, 1100V grade, multistranded copper conductor drawn through and including 25mm dia non-metallic rigid PVC conduit with conduit accessories concealed /fixed to walls / roofs / floors, etc. and one run of PVC insulated, heavy duty, ISI marked, unsheathed cable 1100V grade 2.5sqmm for earth continuity copper conductor including taking down of old submain wiring and making good the disturbed surfaces to match with the exisiting surfaces complete all as specified and as directed Note:2 runs of 4sqmm and one run of 2.5sqmm conductor and one run of PVC conduit shall be measured as one length
S&F metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket with and inlcuding one SP MCB 20A 10kA including taking down and disposing off old/unserviceable socket complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 415V triple pole and neutral 4 way double door, flushed inside the wall with 200Amps rated busbar with and including 1No. 4P MCCB 63A 16kA as incomer and making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 240V single pole and neutral 8 way double door, flushed inside the wall with 200Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F repairs sheet metal enclosures for MCB distribution board 240V single pole 12 way double door, flushed inside the wall with 200Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F in repairs MCB SPN, 230V, 40Amps 10kA complete all as specified and as directed
S&F in repairs MCB SP 240V, 5 to 40Amps 10kA complete all as specified and as directed
S&F in repairs DP RCBO for earth leakage, overload and short circuit protection, 40A 100mA complete all as specified and as directed
S&F in repairs DP RCBO for earth leakage, overload and short circuit protection, 63A 100mA complete all as specified and as directed
S&F in repairs house service bracket (hook type) fabricated out of 3m long GI tubing 40mm bore medium grade with 02Nos. 90o bends including necessary fixing arrangements with suitable MS clamps, nuts, bolts, washers, etc. and taking down and disposing off old bracket any type complete all as specified and as directed
S&F in repairs digital electric meter single phase, 50Hz, range 10 to 50A rating connected with suitable sized PVC copper cable to DB complete all as specified and as directed Note: Old / unserviceable meters shall be deposited at store of Engineer-in-charge
Taking down carefully exhaust fans (with or without louvers) of 300/380/400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, removing old worn out paint from fan and blades by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and sutable sized font) in body of fan, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed
Taking down carefully ceiling fans, 1200/1400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, removing old worn out paint from fan and blades by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and sutable sized font) in body of fan, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed
M&L for taking out burnt winding of exhaust fans of size 300/380/450mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of ceiling fans of size 1200mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of ceiling fans of size 1400mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
S&F PVC 3 core chord, flexible copper insulated cable 24/0.2mm size black/grey in colour and fixed / laid complete all as specified and as directed
S&F condenser 2.5/3.5/4MFD for ceiling fans / exhaust fans complete all as specified and as directed
S&F ball bearing of existing size suitable for 1200/1400 ceiling fans complete all as specified and as directed
S&F ball bearing of existing size suitable for 300/380/400mm exhaust fans complete all as specified and as directed
S&F canopy of existing size, colour and design suitable for ceiling fans (set of two) complete all as specified and as directed
S&F rubber reel of existing size and make suitable for 1200/1400mm sweep ceiling fans with nuts, bolts and wahsers, etc. complete all as specified and as directed
S&F gun metal bushes of existing size and make suitable for 1200/1400mm sweep ceiling fans complete all as specified and as directed
S&F LED 1x20W batten tube light fitting, wall mounted, extruded heat dessipation, integrated crystal glass body, 230V with connector block, etc. internally pre-wired and connecting up with twin core twisted flexible copper conductor cable of suitable size, with all accessories and 18W LED tube rod including taking down and disposing off of old fitting complete all as specified and as directed
S&F LED light fitting 36W of size 2'x2' environmental friendly new generation aesthetically designed, ultra modern recess mounting luminaire with high bright LED light suitable for false ceiling grid complete all as specified and as directed
S&F in repairs flame proof light (FLP-WP), fluorescent fittings groups IIA & II B, IS 2206 (Part II)/1976, 240V, alongwith LED 2x36/40W all internally connected with all accessories complete all as specified and as directed
Disconnecting from mains and water inlets / outlets and taking down carefully storage water heaters / geysers 25litres capacity, for carrying out required repairs viz. replacing worn out parts, cleaning the same, re-fixing in position, connecting up to power and water lines, testing on re-installation complete all as specified and as directed Note: Spares viz. safety valves, non-return valves, indicator lamps, stainelss steel dome, heating element, thermostat shall be measured and paid separately under respective items herein
Supply only heating element 1.5kW, ISI marked, of existing make
Supply only heating element 2kW, ISI marked, of existing make
Supply only thermostat, ISI marked, of existing make
Supply only indicator lamp Red/Green, ISI marked, of existing make
Supply only air release valve suitable for geysers, ISI marked, of existing make
Supply only stop valve 15mm dia suitable for geysers, ISI marked, of existing make
Supply only rubber gasket for inner tank suitable for geysers, ISI marked, of existing type and make
Supply only thermostat suitable for geysers, ISI marked, of existing type and make
Supply only storage water heater tank of existing size and type suitable for geysers 25litres, ISI marked
Supply only fusable lead nut for safety pressure suitable for geysers, ISI marked, of existing type and make
Supply only geyser base assembly (syphon system) of existing size and make with rubber gasket for 25litres capacity of existing type and size
M&L for for brazing of storage type water heaters (Geysers) 25litres capacity, to stop leakage, dripping, etc. and testing on completion complete all as specified and as directed
Supply only PVC connections 15mm size with PTMT nuts, 600mm long (for hot and cold water inlet and outlet) suitable for geysers
M&L for removing / scrapping of old worn out paint from geysers 25 / 35litres capacity by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (white tint) over a coat of red oxide zinc chrome primer and writing MES number of geysers (tint as approved and sutable sized font) in body of geyser complete all as specified and as directed
S&F riser pipe, header pipe, footer pipe with coating suitable for solar water heaters of existing size, make and capacity including testing on completion complete all as specified and as directed
S&F solar water storage tank of capacity 300litres including cladding with glass wool, GI powder coated sheet of suitable size, connecting hose pipe 25mm dia and connecting up complete all as specified and as directed
S&F solar flat plate collector of existing size and type, suitable for 300litres capacity solar water heaters complete all as specified and as directed
S&F heating element with thermostat 3kW with electric connections complete all as specified and as directed
M&L for taking down split type AC 1.5/2TR capacity for required servicing, cleaning of cooling coil, air filters/plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solutions, etc., checking serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches, knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: Spares / components replaced shall be measured and paid separately under respective items herein
M&L for taking down window type AC 1.5TR / 2TR capacity for required servicing, cleaning of cooling coil, air filters / plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solution, checking the serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: Spares / components replaced shall be measured and paid separately under respective items herein
Supply only running capacitor 36 / 45MFD
Supply only starting capacitor 100-150MFD
Supply only starting relay 1022/1622/2000
Supply only thermostat switch 2059/2064/2054
Supply only plastic condenser fan blade for split type AC 1.5/2T
Supply only plastic condenser fan blade for window type AC 1.5/2T
Supply only copper filter, double capillary, pencil type
Supply only thermocol sheet 40x20inch and 20mm thick
Supply only wiring kit for AC window/split type 1.5/2T
Supply only remote control for split AC 1.5/2T of existing make
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2T
Supply only plastic louvers for front panel for window AC units as per existing type and design
Supply only suction/discharge valve set for split AC units as per existing type and capacity
Supply, installing, testing and commissioning of compressors of AC units in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed for the following types and capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
Split type air conditioner of capacity 2Ton
Split type air conditioner of capacity 1.5Ton
Window type air conditioner of capacity 2Ton
Window type air conditioner of capacity 1.5Ton
Supply, installing and testing of fan motor / blower motors of AC units split type of capacity 1.5/2Ton in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, vacuuming the fins, etc. taking out the fan / blower motor, cleaning, removing dust / dirt, etc., around and replacing motor and finally put the rest back together and commissioning including disposing of old unserviceable motor complete all as specified and as directed for the following types and capacities: Notes: (i) Fan / blower motors shall be from existing manufacturer / as approved by the GE (ii) Fan / blower motors shall bear a minimum guarantee of 5years and as given by manufacturers
Supply, installing and testing of fan motor / blower motors of AC units window type of capacity 1.5/2Ton in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, vacuuming the fins, etc. taking out the fan / blower motor, cleaning, removing dust / dirt, etc., around and replacing motor and finally put the rest back together and commissioning including disposing of old unserviceable motor complete all as specified and as directed for the following types and capacities: Notes: (i) Fan / blower motors shall be from existing manufacturer / as approved by the GE (ii) Fan / blower motors shall bear a minimum guarantee of 5years and as given by manufacturers
Supply, installing and testing of condenser coils of AC units in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed for the following types and capacities: Notes: (i) Condenser coils shall be of existing manufacturer / as approved by the GE (ii) Condenser coil shall bear a minimum guarantee of 5years and as given by manufacturers
Window type air conditioner of capacity 1.5/2Ton
Split type air conditioner of capacity 1.5/2Ton
S&F copper pipe with all necessary brazing, welding, providing butt bolts and screws of required sizes, clamps, etc. including taking down old unserviceable copper pipes of any sizes / dia and disposing off complete all as specified and as directed for the following sizes:
Supply, fixing and testing of cooling coils of AC units in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable cooling coil complete all as specified and as directed for the following types and capacities: Notes: (i) Cooling coils shall be of existing manufacturer / as approved by the GE (ii) Cooling coil shall bear a minimum guarantee of 2 years and as given by manufacturers
Window type air conditioner of capacity 1.5/2Ton
Split type air conditioner of capacity 1.5/2Ton
M&L for charging refrigerant gas F-22/R-134A in window type / split type AC units of capacity 1.5/2Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for removing / scrapping of old worn out paint from window AC units / outer unit of split ACs by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for taking down of split type AC 1.5/2TR capacity by disconnecting both the copper tubes from indoor and outdoor unit, duly storing of its refrigerant, carrying out minor brazing/welding in copper tubing, etc. then duly filling up refrigerant as per desired pressure, refixing in same or other location, making all electrical connections and testing on completion complete all as specified and as directed
S&F in repairs copper Flair nut of size 1/2 inch all as per existing and as approved complete all as specified and as directed
S&F in repairs copper Flair nut of size 1/4 inch all as per existing and as approved complete all as specified and as directed
S&F in repairs insulated piping of split AC units as per existing and as approved complete all as specified and as directed
S&F in repairs MS stand for outer unit of split AC .5/2TR as per the existing size duly fixed / bolted on wall with nuts, bolts and washers including all necessary drilling, welding, etc. at location as approved complete all as specified and as directed
M&L for collecting unserviceable voltage stabilizer of capacity 3 to 5kVA from different locations at Patiala, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
M&L for collecting unserviceable voltage stabilizer of capacity 20kVA from location at Patiala, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
M&L for collecting unserviceable voltage stabilizer of capacity 63 to 200kVA from location at Patiala, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
Supply only voltmeter (Anlogue) 0 to 300V any type / shape single phase 50Hz AC supply
Supply only digital type voltmeter 0 to 300V any type / shape single phase 50Hz AC supply
Supply only printer circuit control card suitable for 3kVA
Supply only printer circuit control card suitable for 4 to 5kVA
Supply only input/output switch
Supply only push-on switch
Supply only indicator with bulbs
Supply only trigger transformer for 3 to 5kVA
Supply only relay for 3 to 5kVA voltage stablizer
Supply only time delay and high/low voltage cutoff circuit with relay suitable for 3 to 5kVA
M&L for taking out burnt winding of transformers of voltage stabilisers 3kVA capacity carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of transformers of voltage stabilisers 4kVA capacity carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of transformers of voltage stabilisers 5kVA capacity carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding and rewinding of buck boost transformer installed in voltage stablizer with copper winding wire as per original gauge, using super enameled/DPC winding wire as per relevant IS, including insulating materials such as cotton tape, packing and sleeves etc. varnishing by vacuum impregnation and testing for proper functioning complete all as specified and as directed
Supplying, installing and testing servo motor of rated torque 3kgcm, 240V,AC supply, syncronised with the existing voltage stablizer complete all as specified and as directed
Supply only capacitor 4MFD for desert cooler
Supply only PVC pipe 1/2 " bore with plastic elbow of existing length
S&F 6mm thick wooden ply of size 3’x6’, water proof, for fixing of desert coolers / window ACs, etc. complete all as specified and as directed
Supply only MS front show grill of existing type and make complete all as specified and as directed
Supply only plastic front show grill of existing type and make complete all as specified and as directed
Supply only wood wool cooler pad (set of three) having weight 500gm/set of existing type and size complete all as specified and as directed
Supply only aluminium fan blades for cooler motor fan of existing type and size complete all as specified and as directed
S&F cooler fan motor of capacity 1/10HP, single phase AC 240V 3 speed suitable for dessert coolers including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F angle iron stand for desert coolers made out of angle iron 40x40x5mm of existing size with four legs including leg supports duly painted with 2 coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed
S&F in repairs MS sheet bottom of tanks for dessert coolers as per exisiting size including fixing arrangement, drilling, bolting, etc. complete all as specified and as directed
S&F in repairs MS sheet side panels of dessert coolers as per exisiting type of size 700x700mm including fixing arrangement, drilling, bolting, etc. complete all as specified and as directed
Disconnecting from mains and taking down for servicing water coolers, 150litres capacity including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions all as specified and as directed Note: Spares / parts / componenets reaplced will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in these unit rates quoted
S&F condenser fan motor of capacity 1/10HP, 1/16 HP single phase AC 220V suitable for water coolers of capacity 80/150litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F in repairs condenser coil fins as per existing type, size and pattern suitable for 40/150litres water coolers complete all as specified and as directed
S&F in repairs evaporator / cooling coil as per existing type, size and pattern suitable for 40/150litres water coolers complete all as specified and as directed
S&F water lifting pump, heavy duty, single phase 240V single phase AC suitable for water coolers of capacity 150litres including disconnecting the electric mains and taking out and disposing off the unserviceable pump and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F company made new sealed compressor units for water coolers 40/150litres including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed for the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
M&L for charging refrigerant gas F-22 in water coolers of capacity 150/80/40litres including taking down of compressor units, cooling coils, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for removing / scrapping of old worn out paint from water coolers 40/150litres by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of coolers (tint as approved and sutable sized font) in body of cooler complete all as specified and as directed
S&F in repairs water cooler tap, self closing, 15mm dia complete all as specified and as directed
Supply only overload protector device suitable for water coolers 40/150litres all as specified and as directed
Supply only starting relay open / box type suitable for water coolers 40/150litres all as specified and as directed
Supply only starting capacitor 80 to 100MDF suitable for water coolers 40/150litres all as specified and as directed
Supply only running capacitor 25MFD suitable for water coolers 40/150litres all as specified and as directed
Supply only drain hose pipe 40mm bore suitable for water coolers 40/150litres all as specified and as directed
Supply only plastic condensor motor fan blade 1/10HP or 1/16HP suitable for water coolers 40/150litres all as specified and as directed
Supply only MS condensor motor fan blade 1/32HP or 1/35HP suitable for water coolers 40/150litres all as specified and as directed
Supply only copper filter pencil single / double capillary suitable for water coolers 40/150litres all as specified and as directed
M&L for taking out water cooler tank from water cooler 40 to 150litres capacity, repairing the tank with brazing, welding, etc. to stop leakage, etc. cleaning, providing and inserting new glass wool, tarpaulin sheet, etc. and and refixing in position and testing on commissioning complete all as specified and as directed
S&F top door made out of stainless steel 20 guage sheet with suitable handle and locking arrangement with double keys including door gasket, recommended insulation material and PVC inner sheet of suitable thickness for 40 to 150litres capacity water coolers as per eixsiting size and shape, including all necessary welding, drilling works and providing new nuts, bolts, washers, etc. as required complete all as specified and as directed
S&F PVC connections 15mm size with PTMT nuts, 900mm long suitable for water coolers complete all as specified and as directed
S&F stop vlave cast copper alloy screw down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm dia bore for water coolers complete all as specified and as directed
M&L for disconnecting from mains for servicing refrigerator / deep freezer of capacity 165 to 310litres, cleaning of cooling coil, condenser, compressors, with vacuum cleaner and cleaning solution including detecting of any leakage of gas, refilling if required, checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc. and checking serviceability of the unit for satisfactory working condition complete all as specified and as directed Note:- Defective spares shall be replaced and will be measured and paid separately under relevant items herein
Supply only thermostat switch with knob suitable for refrigerators / freezers
Supply only starting relay 1/6HP open type with OLP suitable for refrigerators / freezers
Supply only starting relay 1/8HP open type with OLP suitable for refrigerators / freezers
Supply only copper filter single capilary pencil type suitable for refrigerators / freezers
Supply only door lock suitable for refrigerators / freezers
Supply only door switch suitable for refrigerators / freezers
Supply only interior light fitting suitable for refrigerators / freezers
Supply only door handle of existing design suitable for refrigerators / freezers
Supply only compartment glass suitable for refrigerators / freezers
M&L for charging refrigerant gas F-12/22/R-134A in refrigerators 165 to 310litres capacity including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
S&F company made new sealed compressor units for refrigerators, 165/310litres capacity including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
Swami Engineers
Buttar Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .