Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹5.0 LAccepted-AOC | l1 | Accepted-AOC L1 Bidder | |
| 2 | Rejected-Technical | - | Rejected-Technical NOT FULFILFILLING THE REQUIED CRITERIA | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT FULFILFILLING THE REQUIED CRITERIA | |
| 4 | Rejected-Technical FCA 560 BLB EAST CHAWLA COLONY SAURAJ SINGH YADAV BALLABGARH VILLAGE TOWN CHAWLA COLONY CITY FARIDABAD FARIDABAD HARYANA 121004 INDIA | FARIDABAD | HARYANA | 121004 | - | Rejected-Technical NOT FULFILFILLING THE REQUIED CRITERIA |
Tender Value
Refer Docs
Closing Date
10 Jun 2021, 6:00 pmClosed
CWE NO 2
CWE NO 2
ADDN ALTN AND UPGRADATION OF JCOS MD ACCN AT BASANTAR LINE UNER GE WEST DELHI CANTT
2021_MES_444674_1
3001/04/E3
Open Tender
Consultancy Services
Item Rate
30 days
GE WEST DELHI CANTT
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
18 Oct 2021
21 May 2021
12 Jun 2021
22 May 2021
10 Jun 2021
24 May 2021
22 May 2021 - 23 May 2021
Amount
1. Visual inspection : To carry out a detailed visual inspection for surface damages, cracks, seepage, local weakness and to identify locations of structural and functional distress and locations suspected to develop structural and functional distress of the buildings. 2. Non destructive test(NDT) : Non destructive evaluation of the structural elements by various tests as required locations and structural assessment based on these parameters. 3. Rebound Hammer Test : To check the compressive strength of concrete as per IS-13311-1992 Part II. 4. Ultrasonic Pulse Velocity (UPV) : as per IS-516, measurements on the RCC elements to find out the quality of concrete. 5. PH value test : To draw sample of concrete and PH value test (to check alkanity of concrete) as per relevant IS-456:2000, BS-8110. 6. Carbonation : To check the penetration depth of carbonation in concrete. 7. Core cutting & compressive strength test : Take out the sample of cylindrical concrete and carryout compressive strength test at a min of one location per dwelling unit. 8. (viii) Corrosion monitoring : To measure the risk and rate of corrosioin of steel in concrete by half cell potential of reinforcement to assess the risk of corrosion. 9. Concrete cover measurement : Measurement of thickness of concrete cover to reinforcement bars by cover meter test. 10. Chemical analysis : To draw samples of concrete and carry out chemical analysis of the sample including measurement of chloride content. 11. Thermographic imaging : for inspection of moisture/dampness in the structures for pin pointing the moisture trail. 12. Structural Evaluation and Retrofitting Scheme : This would include assessment of adequacy of existing structural components and providing retrofitting scheme to strengthen the inadequate structural components including repair methodology, preparation of bill of quantities (BOQ), specifications for the work. Report must be submetted in quadruplicate. Report/BOQ/Drawings on structural issue should be vetted by IIT/NIT. Report must be submitted in quardruplicate.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .