| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.5 L+₹17,714 (0.57%)Rejected-Finance | L2 | Rejected-Finance Ll2 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
24 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMNAGAR NO.1
AIRFORCE STATION NO.1 JAMNAGAR GUJRAT
REPAIR/ MAINT TO SEWAGE LINE ALONG WITH MISC B/R WORKS AND REPAIR/MAINT TO SHORT ARM FIRING RANGE AT AFS SAMANA
2020_MES_356369_2
8736/E8
Open Tender
Civil Works - Highways
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR NO.1
₹86,000
Yes
17 Sept 2020
10 Aug 2020
25 Aug 2020
10 Aug 2020
24 Aug 2020
10 Aug 2020
60 days
Amount
M&L for Cleaning of sewage lines 100 to 200 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc outside MD land and refixing properly manhole covers etc complete all as specified and directed by Engineer-In-Charge.
M&L for Cleaning of sewage lines 300 mm to 450 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc outside MD land and refixing properly manhole covers etc complete all as specified and directed by Engineer-In-Charge.
M&L for Removal of blockage from Indian WC / EWC / floor trap / nahani trap by removing all sludge / waste etc including cleaning of connected pipe up to first manhole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc outside MD land all as directed by Engineer-in-Charge
M&L for Cleaning & desludging of manholes of depth not exc 1.0 meter, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc outside MD land complete all as specified and directed by Engineer-In-Charge.
M&L for Cleaning & desludging of manholes of depth exc 1.0 metre but not exc 2.0 meter, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc outside MD land complete all as specified and directed by Engineer-In-Charge.
M&L for Cleaning & desludging of manholes of depth exc 2.0 metre but not exc 5.0 meter, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc outside MD land complete all as specified and directed by Engineer-In-Charge.
Disconnecting existing tank of capacity exc 250 ltrs but n exc 500 ltrs setting aside or lowering if required for cleaning and reconnecting or refixing in same position or other position, including cleaning and removing all scale and dirt etc from tanks and from the mouths of circulating pipes etc complete all as specified and directed by Engineer-In-Charge.
Dismantling Reinforce Cement Concrete of Drain cover and in any position
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls and set in cement mortar 1:4 including taking down old cover complete all as specified and directed by Engineer-In-Charge. Note:- Reinforcement steel will be measured & paid separately
M&L for mild steel TMT bars 6 to 8 mm dia and over cut to length bent to shape and required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips complete.
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed by Engineer-In-Charge.
Extra over item No 11 hereinbefore for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, moulds, mitered/stopped and etc complete all as specified and directed by Engineer-In-Charge (inner girth to be measured only).
S&F in repair Cast iron, floor trap, with grating outlet dia 100 mm, including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
S&F in repair Salt-glazed stoneware gully traps, square or round mouthed, type of size 150 x 100 mm complete all as specified & directed by Engr-in-Charge.
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to a distance exc 1.5 km but n.exc 3 Km
M&L for Non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed by Engineer-In-Charge.
M&L for Non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed by Engineer-In-Charge.
M&L for digital printed joint free (edge cut) coloured glazed ceramic tiles 7 mm to 8 mm thick (square / rectangular) polished area of each tile exc 0.11 Sqm but n. exc 0.18 sqm as in skirting / dado etc laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed by Engineer-In-Charge.
M&L for light shade (double charged) colour vitrified ceramic tiles 8-10 mm thick (square/rectangular ) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match. the tiles complete all as specified and directed by Engineer-In-Charge.
M&L for Rubber moulded chequered cement concrete tile with white cement and pigment (of approved tint) of size 30 cm x 30 cm x 25 mm thick over and including 15 mm thick screed bed in cement Mortar 1:6, set, jointed and pointed in neat cement slurry complete all as specified and directed by Engineer-In-Charge.
M&L for green marble work 15 to 18 mm thick (table, rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar(1:4) including pointing in coloured cement(1:2) using marble dust with admixture of pigment to match with marble shade laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-In-Charge.
M&L 15-18 mm thick granite stone slab of any type with (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like set in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite slab laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed by Engineer-In-Charge.
M&L for outdoor coloured vitrified paving tiles, joint free (edge cut) of size 300 mm x 300 mm x 8 to 10 mm thick as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed by Engineer-In-Charge. Make - HR Johnson - Endura series or equivalent type of make mention in Appx 'B'
S&F in repair PVC waste pipe flexible type suitable for couplings 32 / 40 mm dia and 750 mm long. MAKE:- PRAYAG or equivalent make approved by the GE.
S&F in repair brass CP waste coupling (half or full threaded) of 32 / 40 mm size complete all as specified and directed by Engineer-In-Charge.
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 450 x 300 mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, 750 mm long PVC waste pipe, PVC connection pipe, 15 mm size and 450 mm long with PTMT nuts and washer at both end etc complete all as specified and directed by Engineer-In-Charge.
S&F corner basin white colour 400x400x210mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, 750 mm long PVC waste pipe, PVC connection pipe, 15 mm size and 450 mm long with PTMT nuts and washer at both end etc complete all as specified and directed by Engineer-In-Charge.
Supply and fix in repair white vitreous china table top basin of size 435 mm x 700 mm x 135 mm fixed in position as per manufacturer instruction and connecting to drain pipe complete all as specified and directed by Engineer-In-Charge. Make: Jaquar Cat No ARS-WHT- 39903 or equivalent of make mention Appx B
S&F in repair 15 mm bore fancy type pillar taps cast copper alloy capaston head chromium plated, screwed down high pressure with or without lettered “ HOT” or “ COLD” with long screwed shanks and fly nuts screwed for iron pipes fixed as in repair complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm size stop cock, cast copper alloy, chromium plated, fancy type with capstan head, with long shank and cup, screwed both end for iron pipes complete all as specified and directed by Engineer-In-Charge.
S & F in replacement Vitreous China squatting pan, of ‘Orissa pattern ‘ white of size 580 X 440 mm, with integral foot rests and 'P' or 'S' trap including provision of cement concrete (1 cement, 2 sand or surkhi and 5 aggregate) bedding minimum 150 mm thick complete all as specified and directed by Engineer-In-Charge.
S&F in repair Coupled floor mounted vitreous china wash down water closet pan (pedestal pattern) with flushing cistern and soft closing seat cover, closet pan size 660 mm x 415 mm x 830 mm, S trap of size - 220mm, hinges, accessories set and all fittings complete all as specified and directed by Engineer-In-Charge. Make:- Jaquar- Cat No for closet CNS-WHT-751SS and Cat No for cistern CNS-WHT-201 or equivalent of make mentioned in Appendix 'B'
S&F in repair health faucet with 1 meter long easy flex tube in chrome finish & wall hook, complete all as specified and directed by Engineer-In-Charge. Make:- Jaquar-ALD-CHR-565 or equivalent of make mentioned in Appendix 'B'
Supply and fix in repairs 10 Litre capacity PVC symphonic action type flushing cistern, duel flush type (ISI Marked) low level with inlet ball valve, float and handle & PVC flush pipe, fixed in position and connecting complete all as specified and directed by Engineer-In-Charge.
S&F in repair Vitreous China urinals, full stall type white, (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.
S&F in repair PVC flush bend 32 mm dia with two Nos check nuts for connecting low level flushing cistern to European type water closet or India type water closet including solvent cement joint complete all as specified and directed by Engineer-In-Charge.
S&F in repair 100 mm x 100 mm stainless steel grating grade 304 fixed over floor trap complete all as specified and directed by Engineer-In-Charge.
S&F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm.
Supply and fix in repair 500 litres capacity triple layer, white coloured rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed by Engineer-In-Charge.
Supply and fix in repair 1000 litres capacity triple layer, white coloured rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed by Engineer-In-Charge.
S&F in repair 20 mm size Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair and all as specified and directed by Engr-in-Charge.
S&F in repair PVC cabinet with mirror, of size 350 mm x 450 mm, fixed to wall with screw complete all as specified and directed by Engineer-In-Charge. Make:- Prayag Cat No 551 or equivalent of make Commander / Neelkamal / Polytuff
Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line including taking down old tubing all as specified and as directed by Engineer-in-Charge.
S&F in repair 15mm bore bib taps, fancy type brass chromium plated with crutch or battery handle screwed down, screwed for iron pipe or brass ferule.
S&F Bottle Trap (with Internal Partition) 32 mm Size with 250mm & 190mm Long with all Connection Pipes complete all as specified and directed by Engineer-In-Charge. Make: Jaquar Cat No ALD-769L or equivalent of make mention Appx B
Demolition and breaking up drain pipes of internal dia 150mm to 200 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar.
M&L for providing 150 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars.
M&L for providing 200 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars.
M&L for Concrete bed to drain pipes type C2 1:4:8 bore of pipe 150 mm including packing under, and haunching against the sides of pipes after they are laid and tested
M&L for Concrete bed to drain pipes type C2 1:4:8 bore of pipe 200 mm including packing under, and haunching against the sides of pipes after they are laid and tested
M&L cement concrete 1:3:6 Type C-2 (using 40mm graded aggregate) as in foundation,filling and mass concrete complete all as specified and directed by Engr-in-Charge.
Dismantling of cast iron pipe jointed in cement of 100 mm dia. incl bend junction etc complete all as specified and directed by Engineer-In-Charge.
Dismantling of cast iron pipe jointed in cement of 75 mm dia.incl bend junction etc complete all as specified and directed by Engineer-In-Charge.
S&F sand cast iron soil waste and vent pipes in any length with or without ears with cement joints in walls/floors of 100 mm bore complete all as specified and directed by Engineer-In-Charge.
S&F sand cast iron soil waste and vent pipes in any length with or without ears with cement joints in walls/floors of 75 mm bore complete all as specified and directed by Engineer-In-Charge.
S&F in repair cast iron bends (any) radius of 100 mm bore with access door complete all as specified and directed by Engineer-In-Charge.
S&F in repair cast iron bends (any) radius of 75 mm bore with access door complete all as specified and directed by Engineer-In-Charge.
S&F in repair cast iron cowls of 100 mm complete all as specified and directed by Engineer-In-Charge.
S&F in repair cast iron cowls of 75 mm complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of old decorated surfaces of walls by brooming down or steel wire brushes, scrapping down smoke soot, moulds, efflorescent salts etc and applying one coat of white wash complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of old decorated surfaces of ceiling by brooming down or steel wire brushes, scrapping down smoke soot, moulds, efflorescent salts etc and applying one coat of white wash complete all as specified and directed by Engineer-In-Charge.
M&L for Preparation of old distempered / decorated surfaces of walls including washing, rubbing down and stopping holes, trading oil and greasy spots and applying one coat of Distemper oil emulsion complete all as specified and directed by Engineer-In-Charge.
M&L for Preparation of old distempered / decorated surfaces of walls including washing, rubbing down and stopping holes, trading oil and greasy spots and applying two coats of Distemper oil emulsion complete all as specified and directed by Engineer-In-Charge.
M&L for complete removal of existing treatment from old painted surfaces of walls by brooming down or steel wire brushes, scrapping down smoke soot, moulds, efflorescent salts etc and applying two coats of Distemper oil emulsion over one coat of primer after applying 3 mm thick cement based wall care putty complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of old decorated surfaces of walls including pilasters / cornices etc and applying one coat of Acrylic emulsion (exterior weather coat) paint of any tint as approved applied as per manufacturer's instruction complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of old painted wooden surfaces, exc 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed by Engineer-In-Charge.
M&L for preparation of old painted steel surfaces, exc 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed by Engineer-In-Charge.
M&L for filling of wooden saw dust mixed with clean dry fine sand (mixed in the ratio of 1:1 by volume) and filling / spreading where directed at a level upto 8 metres above from the ground level and leveling in the required shape / slope complete all as specified and directed by Engineer-In-Charge. Note:- Measurement shall be carried out for net finished volume of work.
Removing old worn out (unserviceable) HDPE bags / gunny bags from stacks filled with sand etc and supply & placing in position new HDPE bags / gunny bags inner laminated layer standard quality, wt. of bag shall not be less than 90 Grams per bag and filled with locally available sand / soil (Approx. Qty – 1.20 Cuft. in each bags) including tying properly & stacking neatly, placing the bag at different heights etc. complete all as specified and directed by Engineer-In-Charge.
Dismantling of plain or corrugated steel sheeting any gauge, thickness, from roof coverings etc complete all as specified and directed by Engineer-In-Charge.
S&F 0.63 mm thick Galvanized corrugated mild steel sheeting, zinc coating not less than 120 grams / Sqm with two corrugation side lap and end overlap not less than 150 mm, fixed with J or L hook with cup washers etc as in roof covering complete all as directed by Engr in Charge.
S&F pre-painted galvanized aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering / cladding to wall, molding / folding in circular / semicircular of any position and height fixed with self tapping screws as specified, as directed by Engr-in-charge
Supply & Fix 06 mm thick plain, multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with self drilled screws and standard fittings, fixtures and accessories complete all as specified and as per manufacturer's instructions complete all as specified and directed by Engineer-In-Charge.
S&F Steel work in trusses fabricated with reactangular / Square hollow section, including special shaped, washers etc including cutting welding, bending in shape etc using tube of YST 310 grade confirming to to IS-4923 complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide.
S&F in repairs galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolt .including .securing or tying at crossing with and provision of galvanized mild steel wire staples or steel pins etc. as directed ( each line wire to be measured )
Supply and fix in repair mild steel galvanised punched type concertina coil of loop dia 1050 mm (dia of coil when up stretched) fixed to existing angle post strut and tying at three places ie two bottom & one at top with 3.15 mm dia galvanised mild steel wire all as specified and directed by Engineer in Charge.
Note:- The punched type concertina coil shall be stretched to maintain the dia of up stretched coil as 1050 mm and number of circles as 52 per coil and shall cover 8 running metre per coil.
Demolition of brick / stone / PCC block masonry / RCC Jalli fixed in cement mortar including all quoins, pillars, arches etc. complete all as specified and directed by Engineer-In-Charge.
Demolition of cement concrete in ground floor and pavings not exc 15cm thickness below or above ground level, all as specified and as directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-In-Charge.
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, complete all as specified and directed by Engineer-In-Charge.
M&L for providing precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks exe 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall or pillars complete all as specified and directed by Engineer-In-Charge.
All as per item No 83 above but except stone. Note:- Serviceable stone retrieved from item No 15 above shall be used for this item
M&L for reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like, weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed by Engineer-In-Charge. Note :- Reinforcement will be measured & paid separately
M&L for Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces and surface finished even and smooth without using extra cement.
M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and surface finished even and fair without using extra cement.
M&L for preparation of plastered surface of walls including plaster / cornices etc and applying two coats of Acrylic emulsion (exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of plastered surface of walls including plaster / cornices etc and applying two coats of oil bound distemper over one coat primer over and including one coat of cement base wall care putty applied as per manufacturer's instruction complete all as specified and directed by Engineer-In-Charge.
M&L for 100 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in Sub base / path / flooring complete all as specified and directed by Engineer-In-Charge.
M&L for 100 mm thick PCC 1:2:4 type B2 using 20 mm graded stone aggregate as in floor / hardstanding, laid in alternate bay system, finish the surface fair & even and fair complete all as specified and directed by Engineer-In-Charge.
Extra over item No 91 for broom finish to concrete surface of floor / hardstanding while concrete is green.
M&L for forming 12 mm thick Expansion joints filed with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound Grade 'A' for 100 mm thick concrete slab.
M&L for Forming Contraction (Dummy) joints 30 mm deep x 10 mm wide, filled with sealing compound Grade A.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L for 75 mm thick plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in plinth protection including finished even and smooth without using extra cement and all as directed by Engr-in-charge.
Material & Labour for machine pressed precast concrete interlocking paver block of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating, top surface with white cement and pigment laid over and including 20 mm thick (compacted thickness) sand screed bed complete all as specified and directed by Engineer-In-Charge.
M&L for Rubber moulded chequered cement concrete tile with white cement and pigment (of approved tint) of size 30 cm x 30 cm x 25 mm thick over and including 15 mm thick screed bed in cement Mortar 1:6, set, jointed and pointed in neat cement slurry complete all as specified and directed by Engineer-In-Charge.
M&L for outdoor coloured vitrified paving tiles, joint free (edge cut) of size 300 mm x 300 mm x 8 to 10 mm thick as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed by Engineer-In-Charge. Make - HR Johnson - Endura series or equivalent type of make mention in Appx 'B'
M&L for providing 300 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars.
M&L for Concrete bed to drain pipes type C2 1:4:8 bore of pipe 300 mm including packing under, and haunching against the sides of pipes after they are laid and tested
Sagathiya Builders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .