Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹8.3 L+₹36,776.25 (4.63%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹9.0 L+₹1.1 L (13.9%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹9.3 L+₹1.4 L (17.4%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-Finance Being not lowest |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
30 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR 342011
REPAIR AND MAINTENANCE OF HT CABLES,HT JOINTS AND CONNECTED ITEMS IN TECH AREA AF STN JODHPUR
2024_MES_635422_1
86076/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF JODHPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE AF JODHPUR
₹29,000
Yes
23 Feb 2024
2 Jan 2024
6 Feb 2024
2 Jan 2024
30 Jan 2024
16 Jan 2024
Amount
Dismantling of cross arms / bracing supports / clamps / back plates or any other structural steel sections including removing nuts bolts washers etc complete all as specified and directed.
M&L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed.
Dismantling & taking down, old, defective, weak insulator, any type, any size any shape (pin/shack/loop) complete all as specified and directed.
S&F pin type insulator porcelain vitreous white / brown / green including one galvanised mild steel spindle, two galvanised iron washers, one galvanised iron nut, suitable for 11000 volts grade & of size 150 mm dia and 150mm height complete all as specified and directed.
S&F disc type insulator porcelain vitreous white / brown / green 11000 V, grade 145 mm height & 255 mm dia ball and socket type two in series assembly for tension with tension clamp for conductor working pressure 11000 volts complete all as specified and directed.
Dismantling & taking down old, deteriorated, switch air break and supply and fixing switch air break gang operated triple pole mechanically operated horizontal/vertical type mounted on insulator & steel frame, with operating mechanism worked from ground level for current rating upto 200 Amps horizontal type suitable for 11000 V. grade complete all as specified and directed.
Dismantling & taking down old, deteriorated, dropout fuse assembly and supply and fixing dropout fuse assembly with two insulators including HT fuse as per existing rating,suitable for 11000 V grade complete all as specified and directed.
M&L for servicing and greasing of mechanical parts of existing 11KV horizontal/vertical type GOD including replacement of parts i.e Male/female contact, jumper ,operating mechanism, GOD rod etc specified and directed by Engr-in charge.
M & L for trimming/cutting the tree branches/ bushes around the HT over head 4 pole structure and making safe clearance up to 4.00 metre distance from line wire all as directed by Engineer-in-Charge.
M&L of checking of HT 11 KV cable of any size by means of HT Cable Fault Locator Machine for identifying fault location in HT cable faults complete all as specified and directed.
Supply and fix in repair cable joint kit for 11 KV grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge.
Supply and fix in repair cable joint kit for 11 KV grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge.
S&F in repair cable joint kit for 11 KV grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size1 120 to 185 sqmm complete all as specified and directed by the Engineer - in - Charge.
S&F in repair cable joint kit for 11 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge.
S&F in repair cable joint kit for 11 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size from 120 to 185 sqmm complete all as specified and directed by the Engineer - in - Charge.
S&F in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge.
S&F in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed by the Engineer - in - Charge.
S&F in trench/wall / pole XLPE insulated PVC sheated armoured heavy duty HT electric cable with aluminium stranded conductor 11000 volt grade of sizes 95 Sqmm 3 Core complete all as specified and directed.
S&F in trench/wall / pole XLPE insulated PVC sheated armoured heavy duty HT electric cable with aluminium stranded conductor 11000 volt grade of sizes 185 Sqmm 3 Core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.
M&L for Sand cusioning for cable with screened & washed sand & punning to provide a required cover complete all as specified and directed.
M & L for Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surroundings to make a over all presentable condition all as directed by Engineer - in - Charge.
S&F in replacement GI tubing light grade 80 mm dia for /pole cable protection including fixing clamp, nut bolt washer complete accssories complete all as specified and directed.
Dismantling & taking down old, deteriorated, lightening, arrestor and supply and fixing testing litghtening arrestor Expulsion out door type discharge current 10 KA assembly suitable for 12 KV including all clamps ,nuts, bolts and washers and connection to earth with 32 x 6 mm GI strip and including expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 Voltrs complete all as specified and directed.
Material & labour for earthing complete with copper earthing electrode 60cmx60cmx 3.15mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip of 20x3mm, by means of nuts, bolts, check nuts and washer etc, made of copper and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore light grade GI protection pipe, test point etc. Complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. Copper strip beyond 7.5 Metre shall be measured and paid for separately
Material and labour for stone slab/patti, 40 to 50mm thick, rough dressed, Jodhpur stone slab cover in trenches for protection of cables, 25mm to 35mm wide and 80 cm long, laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
M&L in replacement danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 KV of size 25 x 20 cm complete all as specified and directed.
M&L in replacment GI pipe Light grade with all fittings complete laid in trenches/fixed on pole with suitable clamp all as specified for 100 mm bore of pipe for protection of UG cable complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 32mm x 6mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore light grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
S&F in repairs end termination box HT side with cover made of 3mm thick MS sheets including fibre board insulation sheets & including nut bolts and washer including painting of steel surfaces with two coats of red oxide zinc chorme primer all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 36 above but for LT side.
S&F in repairs heat shrink right angled boots for XLPE 11 KV 95 Sqmm cable including dismantling of HT cable from HT side of Transformer / HT Breakers.
S&F in repairs heat shrink right angled boots for XLPE 11 KV 185 Sqmm cable including dismantling of HT cable from HT side of Transformer / HT Breakers.
Taking down/Shifting carefully transformer/RMU any capacity, any make, any type from pole / plinth by dismantaling, dis-connecting HT & LT sides, earthings of transformer/RMU , supporting angles/cross arms, Shifting / transporting transformer/RMU carefully from the site to the other location within the Air Force Station, Jodhpur premises location and refixing at site with all electrical connection to the entire satisfaction of Engineer -in- Charge.
Dismantaling top cover of transformer of capacity upto 630 KVA , any make for repair / replacement of HT/LT bushing of transformer, including replacement of top cover gasket, bushing gasket for inspection of transformer or for internal repairs of transformer all including draining carefully transformer oil as required / upto the required level and refilling the same, re fitting the top cover of transformer after completion of the work including testing complete etc all as specified and directed. Note: Spare parts required for repair work shall be measured and paid separately under respective items.
Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket / seal , or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.
M&L for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer/Voltage stabilizer with the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV all as directed by Engineer-in Charge. Note:- (i) Dehydration/filtration machine will be arrange by the contractor and he will make his own arrangement and to carry the machine at various sub stations including vehicle and towing arrangement. The rate shall be inclusive as above. (ii) Contractor will submit before & after testing report of transformer oil.
S&F in replacement of transformer oil in site for toping up the level of oil having dielectric strength between 55-65 KV during filling after initial filtration of any capacity complete all as specified and directed by engineer -in- charge.
M&L for replacement of defective silica gel breather assembly with silica gel complete set upto 630KVA all as directed by Engineer-in-Charge
M&L for replacement of LT bushing of brass with neoprene rubber bush for Transformer upto 630KVA capacities all as directed by Engineer-in Charge.
M&L for replacement of HT bushing of brass with neoprene rubber bush for Transformer upto 630KVA capacities all as directed by Engineer-in Charge.
Suply only Silica gel complete all as specified and directed by Engineer -in- Charge.
Supply and laying stone aggregate of size 40mm graded laid on ground around of two/four pole structure complete all as specified and directed. Note: For the payment of loose aggregate a deduction @ 12.5% shall be made from the net measured quantity.
Supply and laying stone aggregate of size 20mm graded laid on ground around of two/four pole structure complete all as specified and directed. Note: For the payment of loose aggregate a deduction @ 12.5% shall be made from the net measured quantity.
LOKESH ELECTRICAL WORKS CONTRACTOR
Nvimal Engineers and Contractor
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .