| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAdmitted-Finance | ₹14.9 L | L1 | Admitted-Finance |
| 2 | L2₹15.7 L+₹88,742 (5.97%)Admitted-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹15.7 L+₹88,742 (5.97%) | L2 | Admitted-Finance |
| 3 | L3₹23.8 L+₹9.0 L (60.3%)Admitted-Finance | ₹23.8 L+₹9.0 L (60.3%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected as per NIT |
| Sl No | Description | Qty | Unit | DWARKADHISH ENTERPRISE L2 | M/s Prakash Enterprises L1 | Krishna Bhoomi Enterprise L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for carrying out repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as specified and directed.
Note:- Repairing such as rewinding, replacement of defective spare part, connecting wire, Over hauling and painting etc will be measured & paid separately under subsequent items. | 885 | Each | 50 ₹44,250 Lowest | 82 ₹72,570 | 125 ₹1,10,625 |
| 2.00M & L for rewinding of ceiling fan of any make by dismantling the ceiling fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing and reassembling. Providing three core copper cable PVC insulated multistranded 0.5mm 30cm length for connection of fan from ceiling rose and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of ceiling fan:- | ||||||
| 2.10 | (a) 1200mm sweep | 600 | Each | 500 ₹3,00,000 | 400 ₹2,40,000 Lowest | 800 ₹4,80,000 |
| 2.20 | (b) 1400 mm sweep | 100 | Each | 510 ₹51,000 | 300 ₹30,000 Lowest | 850 ₹85,000 |
| 3.00M & L for rewinding of exhaust fan motor of any make by dismantling the exhaust fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing ,applying cotton tape and reassembling complete. Providing twin core copper cable 30cm length for connection and testing of fan complete all as complete all as specified and directed. Rewinding should be carried out for the following size of exhaust fan :- | ||||||
| 3.10 | (a) 450mm sweep | 25 | Each | 550 ₹13,750 | 400 ₹10,000 Lowest | 775 ₹19,375 |
| 3.20 | (b) 300mm sweep | 50 | Each | 500 ₹25,000 | 300 ₹15,000 Lowest | 750 ₹37,500 |
| 3.30 | (c) 200mm sweep | 50 | Each | 350 ₹17,500 | 300 ₹15,000 Lowest | 650 ₹32,500 |
| 4.00M & L for rewinding of pedestal fan motor of any make by dismantling the pedestal fan, removing shaft ,bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing ,applying cotton tape and reassembling complete. Testing of fan should be carried out to entire satisfaction of Engr-in-charge. The size of pedestal fan for rewinding shall be as under:- | ||||||
| 4.10 | (a) 300 mm sweep. | 10 | Each | 500 ₹5,000 | 300 ₹3,000 Lowest | 650 ₹6,500 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Jul 2026, 6:00 pmClosed
GE (AF) JAMNAGAR NO.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINT OF CEILING FAN, EXHAUST FAN, WALL MOUNTED FANS AND OTHER APPLIANCES ALONG WITH CONNECTED REPAIR WORKS IN SMQ, OMQ, VARIOUS MESSES AND OTM ACCN AT AF-I UNDER GE (AF) JAMNAGAR NO.2
2026_MES_772801_1
8634/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO.2
₹40,000
Yes
24 Jul 2026
17 Jun 2026
17 Jul 2026
17 Jun 2026
15 Jul 2026
1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for carrying out repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as specified and directed.
Note:- Repairing such as rewinding, replacement of defective spare part, connecting wire, Over hauling and painting etc will be measured & paid separately under subsequent items. | 885 | Each | - | - |
| 0.0 | M & L for rewinding of ceiling fan of any make by dismantling the ceiling fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing and reassembling. Providing three core copper cable PVC insulated multistranded 0.5mm 30cm length for connection of fan from ceiling rose and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of ceiling fan:- | - | - | - | - |
| 0.0 | (a) 1200mm sweep | 600 | Each | - | - |
| 0.0 | (b) 1400 mm sweep | 100 | Each | - | - |
| 0.0 | M & L for rewinding of exhaust fan motor of any make by dismantling the exhaust fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing ,applying cotton tape and reassembling complete. Providing twin core copper cable 30cm length for connection and testing of fan complete all as complete all as specified and directed. Rewinding should be carried out for the following size of exhaust fan :- | - | - | - | - |
| 0.0 | (a) 450mm sweep | 25 | Each | - | - |
| 0.0 | (b) 300mm sweep | 50 | Each | - | - |
| 0.9 | (c) 200mm sweep | 50 | Each | - | - |
| 0.0 | M & L for rewinding of pedestal fan motor of any make by dismantling the pedestal fan, removing shaft ,bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing ,applying cotton tape and reassembling complete. Testing of fan should be carried out to entire satisfaction of Engr-in-charge. The size of pedestal fan for rewinding shall be as under:- | - | - | - | - |
| 0.9 | (a) 300 mm sweep. | 10 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_865359.xls
BOQ • 0.36 MB
08PTenderDocs.pdf
Tender Documents • 0.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .