Tender ID
Tender Value
₹11.3 L
EMD Value
₹28,200
Closing Date
27 Feb 2026, 10:30 pmClosed
Public Works Department
EXECUTIVE ENGINEER
DETAILED SUB ESTIMATE FOR PROVIDING ELECTRIFICATION TO GOVT P U COLLEGE BELTHANGADY AT, D.K. DISTRICT.
PWD/2025-26/BD/WORK_INDENT32046
PWD/2025-26/BD/WORK_INDENT32046
Open
Buildings
Two Tender Document System(Two Cover)
PWD Division Office Mangaluru
3 documents required · 3 mandatory
Banker Details
CLI -Chief Inspectorate of Electrical
List of existing commitments and ongoing work
Assessed available tender capacity: (AxNx2.5-B), where A is the maximum value of civil engineering works executed in any one year during the last five years (updated to current financial year price level) (FY in which tenders are invited), taking into account the completed as well as works in progress. N: Number of years prescribed for completion of the works for which tenders are invited. B: Value, at the current financial year (FY in which tenders are invited) price level, of existing commitments and on-going works to be completed during the next 03 months. (Period of completion of the works for which tenders are invited)
Attach the last five years profit & loss statement certificate countersigned from a chartered accountant with UDIN Number is to be submitted.(2020-21 to 2024-25)
₹500
₹28,200
13 Feb 2026
13 Feb 2026
2 Mar 2026
26 Feb 2026
DETAILED SUB ESTIMATE FOR PROVIDING ELECTRIFICATION TO GOVT P U COLLEGE BELTHANGADY AT, D.K. DISTRICT.
1.10 Manual Means -
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming after watering with a lea... 30.00 m³
11.3.7 Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, includin... 5.00 m
1.6.1 Manual Means -
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, ... 30.00 m
Vol-6, Part - III , Utilization, I No. 1.2.1 Concealed Conduit System . Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and r... 840.00 m
Vol-6, Part - III , Utilization, I No. 1.2.2 Concealed Conduit System . Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and r... 450.00 m
Vol-6, Part - III , Utilization, I No. 1.1.1 Open Conduit System- Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using invert... 180.00 m
Vol-6, Part - III , Utilization, I No. 1.1.2 Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case... 140.00 m
Vol-6, Part - III , Utilization, I No.1.3.1 Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J ho... 540.00 m
Vol-6, Part - III , Utilization, I No. 1.3.2 Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J ho... 295.00 m
Vol-6, Part - III , Utilization, I No. 1.5.1 Supplying and fixing PVC/metal conduit Deep junction box. 19/20 mm deep Junction box ( COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Electrical), I No. 1.5.1) ---- including cost and ... 181.00 Each
Vol-6, Part - III , Utilization, I No. 1.5.2 Supplying and fixing PVC/metal conduit Deep junction box. 25 mm deep Junction box ( COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Electrical), I No. 1.5.2) ---- including cost and con... 130.00 Each
Vol-6, Part - III , Utilization, I No. 1.12 Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod. ( COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Electrical), I No. 1.12) ---- including cost and ... 54.00 No
Vol-6, Part - III , Utilization, I No. 5.18.1 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit bre... 12.00 Each
Vol-6, Part - III , Utilization, I No. 5.18.4 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit bre... 5.00 Each
Vol-6, Part - III , Utilization, I No. 5.18.7 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit bre... 2.00 Each
Vol-6, Part - III , Utilization, I No. 5.19.7 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single ph... 7.00 Each
Vol-6, Part - III , Utilization, I No. 3.4.1 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. ... 24.00 Each
Vol-6, Part - III , Utilization, I No. 3.4.3 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. ... 54.00 Each
Vol-6, Part - III , Utilization, I No. 3.4.5 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. ... 66.00 Each
Vol-6, Part - III , Utilization, I No. 3.4.6 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. ... 40.00 Each
Vol-6, Part - III , Utilization, I No. 2.2.1 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wi... 67.00 Point
Vol-6, Part - III , Utilization, I No. 2.2.2 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wi... 74.00 Point
Vol-6, Part - III , Utilization, I No. 2.2.3 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wi... 81.00 Point
Vol-6, Part - III , Utilization, I No.2.2.4 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wi... 14.00 Point
Vol-6, Part - III , Utilization, I No. 2.3.2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I... 1800.00 m
Vol-6, Part - III , Utilization, I No. 2.3.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I... 2000.00 m
Vol-6, Part - III , Utilization, I No. 2.3.4 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I... 770.00 m
Vol-6, Part - III , Utilization, I No. 3.5.1 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m... 24.00 Each
Vol-6, Part - III , Utilization, I No. 3.5.3 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m... 54.00 Each
Vol-6, Part - III , Utilization, I No.3.5.5 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m... 66.00 Each
Vol-6, Part - III , Utilization, I No. 3.5.6 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m... 40.00 Each
Vol-6, Part - III , Utilization, I No. 3.6.1 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PW... 380.00 Each
Vol-6, Part - III , Utilization, I No.3.6.2 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PW... 8.00 Each
Vol-6, Part - III , Utilization, I No. 3.6.3 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( ... 80.00 Each
Vol-6, Part - III , Utilization, I No. 3.6.4 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module (COMMON SR Vol-6 of 2023-24, Part - III , U... 10.00 Each
Vol-6, Part - III , Utilization, I No. 3.6.9 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD El... 38.00 Each
Vol-6, Part - III , Utilization, I No. 3.6.10 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket (COMMON SR Vol-6 of 2023-24, Part - III , Utilization... 38.00 Each
Vol-6, Part - III , Utilization, I No. 3.6.11 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone Socket (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( P... 20.00 Each
Vol-6, Part - III , Utilization, I No. 3.6.12 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6 (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ... 32.00 Each
Vol-6, Part - III , Utilization, I No.11.3.2 Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power I... 62.00 Each
Vol-6, Part - III , Utilization, I No. 11.5.3 Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewi... 23.00 Each
Vol-6, Part - III , Utilization, I No. 11.8.4 Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection ... 3.00 Each
Vol-6, Part - III , Utilization, I No. 6.3.1 Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball ... 10.00 Each
Vol-6, Part - III , Utilization, I No. 6.1 Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.(COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( ... 3.00 Each
Vol-6, Part - III , Utilization, I No. 13.2.1 Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL... 3.00 Each
Vol-6, Part - III , Utilization, I No. 13.7.1 Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires,... 85.00 Each
Vol-6, Part - III , Utilization, I No. 13.11 Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary lengt... 10.00 Each
Vol-6, Part - III , Utilization, I No. 13.12 Extra length of GI pipe of class B 19mm dia for down rod. (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Electrical), I No. 13.12) ---- including cost and conveyance of all materials all ... 6.00 m
Vol-6, Part - III , Utilization, I No. 13.14 Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.(COMMON SR Vol-6 of 202... 3.00 Each
Vol-6, Part - III , Utilization, I No. 5.42.2 Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front... 25000.00 Sq CM
Vol-6, Part - III , Utilization, I No. 5.40.1 Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insula... 2.00 m
Vol-6, Part - III , Utilization, I No. 5.41.2 Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint... 2.00 m
Vol-6, Part - III , Utilization, I No. 5.18.4 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit bre... 12.00 Each
Vol-6, Part - III , Utilization, I No. 5.18.7 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit bre... 6.00 Each
Vol-6, Part - III , Utilization, I No.5.33 Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT ... 1.00 Each
Vol-6, Part - III , Utilization, I No. 5.15.9 Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O... 1.00 Each
Vol-6, Part - III , Utilization, I No. 5.20.1 Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole (COMMON SR Vol-6 of 2023-24, Part - III , Utilizat... 4.00 Each
Vol-6, Part - III , Utilization, I No.5.12.2 Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 100 A (COMMON SR Vol-6 of 2023-24, Pa... 1.00 Each
Vol-6, Part - III , Utilization, I No.5.7.4 Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 100 A (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Elect... 6.00 Each
Vol-6, Part - III , Utilization, I No. 5.35 Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter.(COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD E... 1.00 Each
Vol-6, Part - III , Utilization, I No. 5.38 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.(COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Electrica... 3.00 Each
Vol-6, Part - III , Utilization, I No. 12.2.1 Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote, Ding Dong Bell (COMMON SR Vol-6 of 2023-2... 3.00 Each
Vol-6, Part - III , Utilization, I No. 32.13 Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as pe... 0.08 Km
Vol-6, (11 kV System), I.no. 21.06 Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff- LT Cable, 35 to 95 Sqmm (Common SR Vol-6 of 2023-24 (11 kV S... 0.08 Km
Vol-6, (11 kV System), I.no. 63.03 Supplying of Brass Cable Gland 40 mm .(Common SR Vol-6 of 2023-24 (11 kV System), I.no. 63.03) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charg... 4.00 No
Vol-6, (11 kV System), I.no. 59.02 Supplying of Haevy Duty Copper Terminal Long Barrel,… 35 Sqmm Copper Terminal Apprx Wt: 17 Gm (Common SR Vol-6 of 2023-24 (11 kV System), I.no. 59.02) ---- including cost and conveyance of all mate... 4.00 No
Vol-6, (11 kV System), I.no. 59.04 Supplying of Haevy Duty Copper Terminal Long Barrel,… 70 Sqmm Copper Terminal Apprx Wt: 28 Gm (Common SR Vol-6 of 2023-24 (11 kV System), I.no. 59.04) ---- including cost and conveyance of all mat... 6.00 No
Vol-6, Part - III , Utilization, I No. 12.56 Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit shoul... 5.00 No
Vol-6, Part - III , Utilization, I No.12.58.2 GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm GI strip (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Electrical), I No. 12.58.2) ---... 22.00 m
Vol-6, Part - III , Utilization, I No. 12.58.3 GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip (COMMON SR Vol-6 of 2023-24, Part - III , Utilization ( PWD Electrical), I No. 12.58.3) --... 34.00 m
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_document_kw-1-32046.doc
Tender Document • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .