Divisional Engineer-(Electrical), Tirumala
Asst.Technical Officer
Annual preventive maintenance and service contract of UPS systems, AMF panels, APFC panels, ACB panels ad 150 KVAR APFC panels etc, available in VQC, NGGH and ATC sections in ESD-West, Tirumala for the year 2026-27
1010689
328/DE(Elec)/TTD/TML/2026-27
OPEN - NCB
Electrical Works
TIRUPATHI
7 documents required · 7 mandatory
₹900
₹63,600
25 Nov 2026
25 Nov 2026
25 Nov 2026
90 days
Part-A (AMC of UPS systems)
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 2 KVA to 3 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 4 KVA to 6 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 7.5 KVA to 10 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 15 KVA to 20 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Only Labour / Engineering Supervision Service Charges for dismantling, shifting one place to another place in same city and Re- installation work UPS Systems with battery Bank.
Supply and fixing of 12V 18/26 AH SMF battery with 3 years Warranty, including wire leads, connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 42 AH SMF battery with 3 years Warranty including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 65 AH SMF battery with 3 years warranty including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 100 AH SMF battery with 3 years warranty including wire leads, connections etc complete. Makes: Quanta / Racket / Exide
Supply and fixing of 12V 180 AH Lead Acid Exide battery XP-1800 / equivalent for DG set with 3 years warranty including wire leads, connections etc complete.
Purchase cost for old life over (failure) existing batteries any make any model under buy back offer.
Part-B :-AMF panels & APFC panels, ACBs
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactor type) 100 to 200 KVAR and Inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete. (Except APFC relay, Capacitors, 100A and above main incomer MCCB / SFDU switch etc.).
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG Set 100KVA to 750KVA) and inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers, Contactors, fuses, indicators, MCBs, etc, complete (Except AMF Relay, 100A and above main incomer contactors / MCCB / ACB switch etc.).
Supply of 24V 20 Amps Battery Charger Working Voltage 230V AC with battery Reverse & Over load / Short circuit protection without Volt / Ammeter.
Supply 12 Stage APFC Relay for APFC Panels, Visa, Baulk or Reputed make.
Supply & Fixing of AMF relay suitable for AMF Panel of 100 to 750 KVA DG Set.
Supply of 3 Pole 110 Amps Power Contactor
Supply of 3 Pole 250 Amps Power Contactor.
Supply of LT PF Heavy Duty 3 Phase 440V capacitors cylindrical Type.
Supply and fixing of DC filter capacitors 2.5Kmfd to 10Kmfd 100 to 250V DC 1 set (3 Nos) 72V to 192V DC operating system 3 to 10KVA On-Line UPS system.
Supply and fixing of DC filter capacitors 2.5Kmfd to 10Kmfd 1 set (3Nos) 120V to 400V DC operating system 10 to 30KVA On-Line UPS system.
Carryout routine maintenance, servicing and testing of 630A to 1000A LT ACB by cleaning fixed contacts, moving contacts and arcchutes including servicing and putting the ACB in perfect working condition after detting all relay and ON, OFF mechanism etc, done with only manufacturing companies.
Note: 1. The service representative should attend maintenance of each ACB for a year and keeping in good working condition. 2. In case there is any break down calls under emergency condition the service engineer should attend under scope of this agreement
Conditions: 1. Contract Agreement will be executed after conformation of AMC work order. 2. Preventive maintenance will be carried out once in Two months. 3. All breakdowns calls, complaints will be attended within 12 hours in rectification or Standby agreement in case delay happen more than 12 hours. 4. The AMC charges are inclusive of all spares cost old spares properly of the company and exclusions of the following spares and service not included this AMC scheme. but could be done on payment basis.
a) Missing /Stolen parts in the systems. b) Shifting of system with accessories. c) Replacement of Battery Bank, APFC relay, Capacitors, AMF relay, main incomer switches and other major spares.
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
Part-A (AMC of UPS systems)
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 2 KVA to 3 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 4 KVA to 6 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 7.5 KVA to 10 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 15 KVA to 20 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Only Labour / Engineering Supervision Service Charges for dismantling, shifting one place to another place in same city and Re- installation work UPS Systems with battery Bank.
Supply and fixing of 12V 18/26 AH SMF battery with 3 years Warranty, including wire leads, connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 42 AH SMF battery with 3 years Warranty including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 65 AH SMF battery with 3 years warranty including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 100 AH SMF battery with 3 years warranty including wire leads, connections etc complete. Makes: Quanta / Racket / Exide
Supply and fixing of 12V 180 AH Lead Acid Exide battery XP-1800 / equivalent for DG set with 3 years warranty including wire leads, connections etc complete.
Purchase cost for old life over (failure) existing batteries any make any model under buy back offer.
Part-B :-AMF panels & APFC panels, ACBs
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactor type) 100 to 200 KVAR and Inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete. (Except APFC relay, Capacitors, 100A and above main incomer MCCB / SFDU switch etc.).
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG Set 100KVA to 750KVA) and inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers, Contactors, fuses, indicators, MCBs, etc, complete (Except AMF Relay, 100A and above main incomer contactors / MCCB / ACB switch etc.).
Supply of 24V 20 Amps Battery Charger Working Voltage 230V AC with battery Reverse & Over load / Short circuit protection without Volt / Ammeter.
Supply 12 Stage APFC Relay for APFC Panels, Visa, Baulk or Reputed make.
Supply & Fixing of AMF relay suitable for AMF Panel of 100 to 750 KVA DG Set.
Supply of 3 Pole 110 Amps Power Contactor
Supply of 3 Pole 250 Amps Power Contactor.
Supply of LT PF Heavy Duty 3 Phase 440V capacitors cylindrical Type.
Supply and fixing of DC filter capacitors 2.5Kmfd to 10Kmfd 100 to 250V DC 1 set (3 Nos) 72V to 192V DC operating system 3 to 10KVA On-Line UPS system.
Supply and fixing of DC filter capacitors 2.5Kmfd to 10Kmfd 1 set (3Nos) 120V to 400V DC operating system 10 to 30KVA On-Line UPS system.
Carryout routine maintenance, servicing and testing of 630A to 1000A LT ACB by cleaning fixed contacts, moving contacts and arcchutes including servicing and putting the ACB in perfect working condition after detting all relay and ON, OFF mechanism etc, done with only manufacturing companies.
Note: 1. The service representative should attend maintenance of each ACB for a year and keeping in good working condition. 2. In case there is any break down calls under emergency condition the service engineer should attend under scope of this agreement
Conditions: 1. Contract Agreement will be executed after conformation of AMC work order. 2. Preventive maintenance will be carried out once in Two months. 3. All breakdowns calls, complaints will be attended within 12 hours in rectification or Standby agreement in case delay happen more than 12 hours. 4. The AMC charges are inclusive of all spares cost old spares properly of the company and exclusions of the following spares and service not included this AMC scheme. but could be done on payment basis.
a) Missing /Stolen parts in the systems. b) Shifting of system with accessories. c) Replacement of Battery Bank, APFC relay, Capacitors, AMF relay, main incomer switches and other major spares.
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
(Rupees Twenty five lakhs fourty thousands five hundred twenty four and paise fourty eight only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ 328.xls
TENDER_DOCUMENT • 2.01 MB
NIT 328.docx
TENDER_DOCUMENT • 0.17 MB
NIT 328.xlsx
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .