Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 Cr+₹22.3 L (14.5%)Rejected-AOC | ₹1.8 Cr+₹22.3 L (14.5%) | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | t.p antony L1 | K T Mathew and Co L2 |
|---|---|---|---|---|---|
| 1.00CONSTRUCTION OF BRIDGE | |||||
| 1.00 | 2.4.2.B:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Prestressed / reinforced cement concrete grade M-20 & above - By Mechanical Means | 8.82 | cum | 1,620 ₹14,288.4 Lowest | 2,500 ₹22,050 |
| 1.00 | 2.4.4.B:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Dismantling Stone Masonry - Rubble stone masonry in cement mortar. | 108.8 | cum | 873 ₹94,982.4 Lowest | 2,900 ₹3,15,520 |
| 1.00 | OD98984/2025-2026:Putting up ring bund as per approved shape 2.5m bottom width, 1m top width using empty gunny/polythene bags filled with earth placed in 2 rows at 0.6m apart and filled in between with puddle clay to form bund for an average height 2.00m including labour dismantling the bund after completion of the work etc. complete (Derived CPWD Building Item No. 60.1.1) | 25 | metre | 2,705 ₹67,625 | 1,800 ₹45,000 Lowest |
| 1.00 | OD99003/2025-2026:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete.(Derived from CPWD Buildings Item No. 60.2.2) | 240 | hour | 513 ₹1,23,120 | 468 ₹1,12,320 Lowest |
| 1.00 | 3.13.1.B:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work. Ordinary soil - Mechanical Means - (Depth upto 3 m) | 30.24 | cum | 270 ₹8,164.8 | 100 ₹3,024 Lowest |
| 1.01 | OD99067/2025-2026:Providing casing pipe of 1000mm inner dia made out of 6mm thick M.S. plate for casting insitu bored piles and erecting at site in lines and levels and driving down to the required depth including cost and conveyance of all materials, all fabrication charges and welding charges with all leads and lifts etc. complete according to the necessity at site as directed by the deptl. officers. (Derived MoRTH Item No.12.22) | 5.53 | MT | 1,27,440 ₹7,05,252.96 Lowest | 1,27,600 ₹7,06,138.4 |
| 1.01 | OD98975/2025-2026:Bored cast-in-situ M35 grade R.C.C. Pile 1000mm dia using rotary boring (Hydraulic rotary type piling) Using Concrete Mixer excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Pile diameter-1000 mm. (Due to the proximity of existing buildings, hydraulic rotary piling shall be adopted instead of percussion piling to prevent potential damage and ensure safety.) | 327 | metre | 12,483 ₹40,81,941 Lowest | 14,290 ₹46,72,830 |
| 1.01 | 12.39:Providing and laying of PCC M15 leveling course 100 mm thick below the pile cap | 2.7 | cum | 9,000 ₹24,309 | 8,280 ₹22,364.28 Lowest |
| 1.01 | 12.38.C.1:Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specifications RCC Grade M30 - Using Concrete Mixer | 21.22 | cum | 11,007 ₹2,33,524.51 Lowest | 11,500 ₹2,43,984 |
Tender Value
₹1.6 Cr
EMD Value
₹50,000
Closing Date
7 Oct 2025, 5:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer Roads South Circle,TVPM
GENERAL Providing BM BC to Thuruvelikunnu Attuvelakadavu Kandathilparambu road 0000 to 03 840 km and CGPS to Kandathilparambu Nanadom road 850m Balance Estimate General Civil Work
2025_PWD_798275_1
TR/RD/2017/9524_5_3_3/1
Open Tender
Civil Works - Roads
Item Rate
360 days
kottayam
Please refer Tender documents.
7 documents required · 7 mandatory
₹6,508
Yes
₹50,000
Yes
11 Nov 2025
17 Sept 2025
10 Oct 2025
17 Sept 2025
7 Oct 2025
17 Sept 2025
Amount
CONSTRUCTION OF BRIDGE
2.4.2.B:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Prestressed / reinforced cement concrete grade M-20 & above - By Mechanical Means
2.4.4.B:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Dismantling Stone Masonry - Rubble stone masonry in cement mortar.
OD98984/2025-2026:Putting up ring bund as per approved shape 2.5m bottom width, 1m top width using empty gunny/polythene bags filled with earth placed in 2 rows at 0.6m apart and filled in between with puddle clay to form bund for an average height 2.00m including labour dismantling the bund after completion of the work etc. complete (Derived CPWD Building Item No. 60.1.1)
OD99003/2025-2026:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete.(Derived from CPWD Buildings Item No. 60.2.2)
3.13.1.B:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work. Ordinary soil - Mechanical Means - (Depth upto 3 m)
OD99067/2025-2026:Providing casing pipe of 1000mm inner dia made out of 6mm thick M.S. plate for casting insitu bored piles and erecting at site in lines and levels and driving down to the required depth including cost and conveyance of all materials, all fabrication charges and welding charges with all leads and lifts etc. complete according to the necessity at site as directed by the deptl. officers. (Derived MoRTH Item No.12.22)
OD98975/2025-2026:Bored cast-in-situ M35 grade R.C.C. Pile 1000mm dia using rotary boring (Hydraulic rotary type piling) Using Concrete Mixer excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Pile diameter-1000 mm. (Due to the proximity of existing buildings, hydraulic rotary piling shall be adopted instead of percussion piling to prevent potential damage and ensure safety.)
12.39:Providing and laying of PCC M15 leveling course 100 mm thick below the pile cap
12.38.C.1:Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specifications RCC Grade M30 - Using Concrete Mixer
12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications
13.5.G.P.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M30 - Using concrete Mixer - Height upto 5m
13.6:Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications
14.1.D.1:Furnishing and Placing RCC/PSC Grade M35 Using Concrete Mixer in super-structure as per drawing and Technical Specification
14.2:Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
14.4:Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
14.10:PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification.
14.11:Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification.
14.6:Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.
OD99102/2025-2026:Drainage Spouts complete as per drawing and Technical specification
APPROACH ROAD
12.1.B.1:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil - Depth upto 3m - Mechanical Means
OD99535/2025-2026:DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site ( Derived CPWD Buildings 60.7.8 )
OD99544/2025-2026:Dry stone masonry with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site (Derived from CPWD Buildings Item No.60.7.1)
12.8.B.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> PCC Grade M20<br>
12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications
OD99551/2025-2026:DR PACKING Under foundation - Dry stone packing under the foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at the site. (Derived from DAR 60.7.2)
3.15:Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means
3.16:Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.
3.17:Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2.
4.1.B.2:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-VI - For sub-base cum drainage layer - Mix in Place Method
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
55.22:Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete.
13.5.C.q.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M25 - Using concrete Mixer - Height 5m to 10m
55.38a:Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on Structural Steel c section vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of structural steel c section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.3.
55.10.1:Providing and erecting retro-reflectorised Object Hazard Marker 300mm x 900mm Providing and erecting retro-reflectorised Object Hazard Marker sign with 07 years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick / aluminium composit material sheeting 4 mm thick with suitable back support frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly fixed 30cm above ground level by means of properly designed foundation with M 15 grade cement concrete 30cmx30x45cm, 45cm below ground level including painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as per approved drawing and clause 801.300 mm x 900 mm
55.14:Providing and fixing retro-reflectorised ceramic tilesProviding and fixing retro-reflectorised ceramic tiles of size 10cmX20cm using High Intensity Micro Prismatic (Type IV) grade sheeting with 7 years warranty fixed over Ist quality ceramic glazed tiles including cost of glue, cutting charges, fixing with suitable adhisive on concrete or other surface etc complete.
8.15:Supplying and installation of delineator (Roadway indicators) posts 80- 100cm high above ground level, pained black, and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorized panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)
8.4.1:Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminum sheeting, 2 mm thick/aluminum composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. 90 cm equilateral triangle
8.5:Providing and fixing of direction and place identification retro-reflectorised sign with 7 years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.
8.8:Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
CONSTRUCTION OF TEMPORARY FOOTPATH
OD101220/2025-2026:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. Including labour for dismantling after completion of the work complete as per the direction of dept. officers ( Derived from DAR 10.16.1)
OD101221/2025-2026:Supply, fabricating, and setting out of 3mm thick Al chequered plates including the cost of conveyance charges, etc. including labour for dismantling after completion of the work complete as per the direction of dept. officers. (Derived from DAR 85.104 & 10.2)
K T Mathew and Co (BID ID -2375328)
Bidder Name
K T Mathew and Co
t.p antony
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .