Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.0 LAccepted-AOC PLOT NO 19 PAOTA C 3RD ROAD JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹57.8 L+₹86,205 (1.51%)Rejected-Finance 37 SUBHASH NAGAR AIR FORCE JODHPUR 342 008 | JODHPUR | JODHPUR | RAJASTHAN | 342008 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹62.3 L+₹5.3 L (9.39%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹62.7 L+₹5.8 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
₹58.2 L
EMD Value
₹1.1 L
Closing Date
9 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR
85952 E8 PROVN OF SECURITY INFRA OF CERTAIN TECH PORTION AND DOMESTIC AT 32 WING AIR FORCE STN JODHPUR UNDER GE AF NO 2 JODHPUR
2022_MES_565049_1
85952/E8
Open Tender
Civil Works
Item Rate
240 days
GE AF NO 2 JODHPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE AF NO 2 JODHPUR
₹1.1 L
Yes
1 Feb 2023
24 Nov 2022
11 Jan 2023
24 Nov 2022
9 Jan 2023
26 Dec 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth as in foundation etc as hard and dense soil complete all as specified and as directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in approved soft/loose soil, including spreading, leveling, wateirng and well ramming in layers n.exc 25 cm thick complete all as specified and as directed by Engineer -in- Charge
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer -in- Charge
M & L Pre-cast cement concrete type C1 1:3:6 20 mm graded aggregate block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed by Engineer -in- Charge
Excavating in Hard & dense soil for post holes (or similar holes) each n exc 0.5 cu. M, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm. complete all as specified and as directed by Engineer-in-Charge.
M & L PCC 1:4:8 type D-2 (with using 40mm graded stone aggregate) as in foundation and mass concrete, complete all as specified and as directed by Engineer-in-Charge.
M & L PCC 1:3:6 type C-2 (with using 40mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge.
S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for fire, etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, blting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 as directed by Engineer-in-Charge.
M&L Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 as specified & directed by Engineer-in-Charge.
M&L 15 mm thick rendering on concrete surface/ stone masonry/ brick surface in cm 1:4, finished even and fair faces complete all as specified & directed by Engineer-in-Charge.
M & L for preparing of new wall surface of walls of plastered or unplastered surface and applying three coat of white wash comlete all as specified and as directed by Engineer-in-Charge.
S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other each screw to be fitted with one hexagonal or square nut lingth of bolts n exc 10 cm and dia of shank 5-10 mm as directed by Engineer-in-Charge.
Supply only GI chain link fencing including line wires, any mesh and any size and type to any type of standards rails etc complete all as specified as directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified as directed by Engineer-in-Charge.
S & F galvanised, 2 stand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails staining bolts incl securing or tying at crossing with and provision of galvanised mild steal wire staples or steel pins etc as directed (each line wire to be measured) complete all as specified as directed by Engineer-in-Charge.
S & F S&F Razor type Concertina coil hot galvanised spring tensile wire 145 to 150 Kg/Sqmm. Weight of coil shall be minimum 8.57 Kg per coil. Stretch of each coil shall be min six meters. No of each coil shall be 50. Galvanised razor ribbon tape shall be of size 0.5 mm thick. 19mm wide before wrapping on central core wire etc all as specified as directed by Engineer-in-Charge.
M & L for two coats of synthetic enamel paint over one coat of red oxide primer on new steel surfaces of any description over 10 cm in width or girth not otherwise described including preparation of surface all as specified as directed by Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as spefied as directed by Engineer-in-Charge.
S & F Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes; framed of water tanks and similar work conforming to Fe. 290. Gde- E-165 extra only over for portions framed and ung as gates including pintile hinges, stops, hand-made sliding bolts etc as directed by Engineer-in-Charge.
M & L PCC 1:2:4 type B-2 (40 mm graded aggregate) in walls or retaining walls, any thickness, size or shape including plasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) as directed by Engineer-in-Charge.
M & L PCC 1:2:4 type B-1 20 mm graded aggregate (Nominal Mix) in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed by Engineer-in-Charge.
M & L Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified as directed by Engineer-in-Charge.
Ditto, but 6mm to 8mm dia as directed by Engineer-in-Charge.
Use and waste of form work to sides of concrete foundations, footing, bases of columns raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical ot to batter for flat of rought finished surface of concrete complete as specified as directed by Engineer-in-Charge.
M & L for preparing of plastered surfaces of walls and applying two coat of cement based paint over a coat of primer chalk whiting complete all as specified as directed by Engineer-in-Charge.
M&L welding in repairs exe 2.5 cm but not exe 5 cm in length thickness of matel to be welded exe 6 mm but not exe 9mm all as spacified as directed by Engineer in charge.
M&L raised pointing on squared rubble masonry coursed or uncoursed (Banglore Pattern) in cement mortar 1:4 as directed by Engineer-in-Charge.
S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as spacified as directed by Engineer in charge.
DEV INDUSTRIES
M/S KAUTILYA GARG
Bansal Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .