Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC | ₹33.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹45.6 L+₹12.3 L (37.0%)Rejected-Finance SCO 26 SEC 30 KURUKSHETRA 136118 | KURUKSHETRA | HARYANA | 136118 | ₹45.6 L+₹12.3 L (37.0%) | L2 | Rejected-Finance Highest |
| 3 | Rejected-Technical PLOT NO 729 INDUSTRIAL AREA PHASE 2 | - | - | Rejected-Technical Rejected |
Tender Value
₹44.2 L
EMD Value
₹88,380
Closing Date
21 Feb 2022, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. of Malaria Office Building in the campus of Civil Hospital, Sec.-6, Panchkula. (Pdg. Central Air Conditioning System).
2022_HRY_206379_1
PWD/Elect-KNL/Elect-AMB/110227
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹88,380
Yes
25 Apr 2022
7 Feb 2022
22 Feb 2022
7 Feb 2022
21 Feb 2022
7 Feb 2022
Amount
Part-A : High Side Works Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. HSR No. 20.72
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp HSR No. 23.22.1.3
4 pole MCCB 200 to 250 amp HSR No. 23.22.1.11
MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP HSR No. 23.22.2.2
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR No. 24.1.3
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR No. 24.1.5
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HSR No. 24.1.7
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR No. 24.1.8
Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core HSR No. 24.2.4.3
Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core HSR No. 24.2.7.4
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm HSR No. 24.2.8.8
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Meter below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia HSR No. 24.5.2.5
NS Items Outdoor Units-Heat Pump (Eco Friendly Gas) Supply, installation testing and commissioning of Modular type outdoor units equipped with highly efficient scroll compressors, low noise condenser fan .COP shall not be less than 3.8 at full load complete in all respectl etc. with capacities as mentioned below : (Non Chinese) Make : Daikin/Mitsubishi-----/LG/Carrier/Tosiba 20 HP NS NS-1
Indoor Units Supply, installation testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. All the vendors can supply the most nearest capacity machines as per below indoor unit details of the same make of ODU Hi Wall 0.8 TR NS NS-2
1.5 TR NS ii)
Supply installation and commissioning of 4 Way Cassette AC with Grills extra of the same make of ODU 1.5 TR NS NS-3
2.08 TR NS ii)
2.56 TR NS iii)
3.01 TR NS iv)
4.55 TR NS v)
Corded and Cordless Remotes NS NS-4
Refnet, (Y-Joint ) Set of Suction & Discharge Pipe NS NS-5
Supply and Installation of Copper Refrigerant Pipe Interconnecting refrigerant pipe work for VRV SYSTEM with 13 mm/19mm thick closed cell elastomeric nitrile rubber tabular insulation between each set of indoor & outdoor units as per VRV specifications and flushing. 28.6mm NS NS-6
22.2mm NS ii)
19.1mm NS iii)
15.9mm NS iv)
12.7mm NS v)
9.5mm NS vi)
6.4 mm NS vii)
Supply and Installation of Electrical Wire an ISO Certified Providing & fixing control cum transmi-ssion wiring /Power/ Control Cabling of copper in suitable conduits between indoor and out door unit & indoor unit & its controller. 2C X 1.5 Sq mm NS NS-7
Rigid PVC Drain piping complete with fittings,supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation. 25mm dia NS NS-8
32 mm dia NS
Cable Tray Perforated GI Tray with threaded rod,nut and washer for hangers &c-chanel for supports of copper piping (250 mm wide) NS NS-9
Refrigerant Commissioning, Nitrogen Flushing, Vacuuming, Refrigerant Charging with R410A NS NS-10
Platform for Outdoor unit with MS Angle/Channel NS NS-11
Supply of aluminiumarmoured cable of size 70 Sq. mm 3.5 Core, Make as per approved list NS NS-12
Supply of aluminiumarmoured cable of size 25 Sq. mm 4 Core, Make as per approved list NS NS-13
Axial Smoke Spill Fans S/I/T/C of single spped axial flow fans complete with totally enclosed fan cooled motor ditect driven and fan shaft, motor mount, bird screen, isolators as per the specification. Fan motor shall be suiatbel for 415 + 10% volts, 50 Cycle, 3 phase power supply. Fans for high temnperature (except for fresh air) rating shall be capable to work at 250 degree celcius for at least two hours. The axial fan shall be supplied witjh power panel. Fan capacity shall be as follows:- High Temperature suitable for 9000 CFM with 25mm static NS NS-14
1st Year - Comprehensive maintenance& Operation cost (after free warranty period only) @ 4% on Original work done amount 1
2nd Year - Comprehensive maintenance& Operation cost @ 4.5% on Original work done amount 2
3rd Year - Comprehensive maintenance& Operation cost @ 5% on Original work done amount 3
4th Year - Comprehensive maintenance& Operationcost @ 5.50% on Original work done amount 4
5th Year - Comprehensive maintenance& Operationcost @ 6% on Original work done amount 5
Pacific Engineers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .