Electrical Installation Work for the office Accomodation of the Dte. of Anti-Corruption Branch for Enhanced effectiveness at 5th Floor Benfish Tower and 6th floor of Benfish Bhawan---SITC of Air Conditioning Machines at 6th Floor of Benfish Bhawan
2026_WBPWD_5075832_1
WBPWD/EE/BED/e-NIQ-123/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Benfish Bhawan
Please refer Tender documents.
6 documents required · 6 mandatory
₹24,441
28 Sept 2026
28 Sept 2026
3 Oct 2026
28 Sept 2026
1 Oct 2026
28 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
Cooling Capacity- 3.5 kW (Minimum) , Air Flow Rate:400 CFM (Minimum), ISEER-5.0 (Minimum) (Make- O General/ Mitsubishi Electric/Daikin) | 6 | Nos. | - | - |
| 1.01 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum), ISEER-5.0 (Minimum) (Make- O General/ Mitsubishi Electric/Daikin) | 4 | Nos. | - | - |
| 1.02 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:600 CFM (Minimum), ISEER-5.0 (Minimum) (Make- O General/ Mitsubishi Electric/Daikin) | 6 | Nos. | - | - |
| 2 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm. (Make-Raiku/Totaline) | 240 | P/Mtr | - | - |
| 2.01 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm. (Make-Raiku/Totaline) | 240 | P/Mtr | - | - |
| 3 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type) | 256 | P/Mtr | - | - |
| 4 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. [Make:- Suprime/Oriplast] | 320 | P/Mtr | - | - |
| 5 | Dismantling of 1.5 ton/ 2.0 ton Air Conditioner Machine with necessary tools and tackles and store in safe place as per direction of EIC. | 3 | Nos. | - | - |
| 6 | Supplying fabrication & fixing of M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40mm) for making Base Frame/platform for installation of outdoor unit of above mentioned AC machines incl. drilling 2 nos holes in each channel, cutting holes into the wall & grouting the same with cement concrete(1:1 1/2:3) etc.fabricated with . horizontal angle of 25 mm x 25 mm x 6 mm and supporting angle of 50mm x50mm x 6mm in each platform in the outer edge for transmitting the load cenrally through 2 nos (50 mm x50mm x6 mm) angle inserted into the existing wall incl. fiber sheet shade as per Direction of E.l.C. The entire structure must be safe to carry out maintenance of ODU, as per Direction of E.l.C. | 1,200 | P/Kg | - | - |
| 7 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge.
(This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly.
(a) 3.9 meter height | 16 | Nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_5167169.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .