Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.2 Cr
EMD Value
₹1.2 L
Closing Date
26 Nov 2026, 4:00 pm2d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
The Superintending Engineer
Bi-Annual Rate Contract (ARC) for restoration of 66kV Tower transmission lines damaged due to natural calamity or in any emergency situations under Navsari Circle
363299
TCNS/ET-132/2026-27
Open
Electrical
Works
Navsari
23 documents required · 22 mandatory · 1 optional
₹8,850
GETCO
₹1.2 L
5 Nov 2026
5 Nov 2026
5 Nov 2026
26 Nov 2026
5 Nov 2026
180 days
Estimated Cost – Rs.
Price of tender fee – Rs. 8850.00.00
Time limit- 24 Months
TENDER NO. TCNS/ET-132/2026-27
(Restoration of 66kV Tower transmission line)
Labour Cost - Part-A Erection
SOR Description. Unit Rates Qty
The work of detail survey, preparation and
submission of profiles in 6 copies (PLSCAD as
well as hardcopy),
Detail scope of Work :-
(a) Fixing of tower as per actual requirement,
site condition and plotting of line on profile
having standard details i.e. span length, lat-
long (co-ordinate), chainage, weight and
wind span, all dimensions, scale, legends,
tower spotting data etc. as per requirement
and along with all require details.
(c) Preparation and submission of tower
schedule as per standard require details with
all the Major - Minor crossing details in profile
PART- drawing and tower schedule, along with due As per site
A-2 care of clearance as per prevailing standards execution
i.e., for all electric line with pole, all type of
track, river, pond, nala, road, canal etc.
(d) Details of Right of Way in profile drawing.
i.e. Building, Temple, Well etc.
(g) Plotting line on TIKKA-MAP (Revenue Land
map) - Required TIKKA-MAP will be provided
Importantly, any work other than mentioned
will align with the specific requirements
outlined by the Engineer-in-Charge.
Note : The survey report will be submit with
sign and stamp of the surveyor agency and
engineer in charge.
Check Survey along with plotting of line
route on village (tika) map with Coordinates
PART- including detailed survey, preparation of As per site
A-3 profiles and revision in original route execution
alignment, if any and as per instruction of
Excavation excluding back filling, but
including shoring, shuttering, dewatering,
PART- tree cutting for tower footings etc. for :- As per site
A-4 a) Normal soil either dry or wet/Sandy soil Cu.m 307 execution
b) Black Cotton Soil either dry or wet Cu.m
c) Normal submerged/marine soil where
dewatering is necessary.
d) Black cotton submerged/marine soil
where dewatering is necessary.
e) Soft Rock Cu.m
f) Hard Rock Cu.m
Installation of steel reinforcement in
concrete foundation including supply of
GETCO Approved M.S. bars, binding wire.
PART- Work also includes their cutting, bending, As per site
A-5 shaping and binding with binding wire and execution
fixing in position of TMT bars as per drawing
before the concrete work and as per
instruction of the EIC
Stub-setting with prop or template including
back-filling, during back filling dispose of (upto6Meter
excess soil and levelling of site is to be done extn)
PART- as per instructions of EIC but excluding As per site
A-6 excavation and concreting etc. for all types execution
of towers/extensions except special towers. (upto 9 to
(Weight of stub, cleat & template with Bolt & 25 Meter
Nuts of stub & template shall be counted) extension
Concreting of foundation by M20/M15/M25
mixture including shoring, shuttering,
compaction, dewatering etc. for normal (M20
tower / tower with extension upto 25mtr. mixture)
PART- As per site
6 After completion of concrete work, curring Cu.m
(watering to concerte) is to be done as per
instruction of EIC. (M15
(Rates are inclusive of supply of GETCO mixture)
approved Cement only.)
Grounding of towers with pipe type earthing
including excavation and back filling, with
supply of all materials like 32mm dia heavy
PART- As per site
7 duty 3 mtr. long G.I. Pipe, 50 x 6 mm G.I. flat, Set.
GI bolt-nuts, with GI spring washer, salt,
charcoal etc. as per drawing and as per
instruction of EIC.
Grounding of towers with COUNTER POISE
TYPE including excavation and back-filling
PART- and supply of all materials like GSS wire, GI As per site
A-9 lugs, GI bolt-nuts, GI Spring Washer, salt, execution
charcoal etc. as per drawing and as per
instruction of EIC.
Erection of super structure upto 6 meter
extension including tree cutting, fixing of
tower accessories, attachments except ACD
PART- /DP /NP /CIP /PP and excluding tack welding As per site
A - 14 of bolts as per instruction of EIC. This execution
includes taking delivery of tower materials
and bolt-nuts from GETCO’s stores etc. for
normal, extension & special towers at
destination and keeping them in safe custody
and transporting the same to erection site.
Same as above but erection of
PART- As per site
10 9/12/15/18/21/25 Mtr. extension with MT
A - 15 execution
Same as Sr.No.14 but erection of Special
River crossing super structure only and
PART- including fixing of ACD / DP / NP / PP / CIP As per site
A - 16 etc. with material like barbed wire, plates, execution
ladder etc. (Total BOM weight is to be
Stub-setting and/OR Anchor bolt-setting of
PART- River crossing tower / above 25 m extension As per site
A - 17 back-filling but excluding excavation and execution
concreting as per instruction of EIC.
Fixing of Anti-climbing devices including
PART- supply of barbed wire as per drawing and as As per site
13 per instruction of EIC.
A - 18 execution
Fixing of DP / NP / PP / CIP including supply
of plates and supply of G.I. bolts-nuts & tack
welding as per drawings and as per
PART- instruction of EIC. As per site
A - 19 a) S/C Loc. 1690 execution
Tack welding of nuts upto approx. 10 mtrs.
height OR two bottom-most panel from
PART- ground level at three places on the nuts Per As per site
A - 20 diametrically and applying zinc rich paint Bolt. execution
immediately after tack welding and as per
instruction of EIC.
Dismantling of any type of tower including
PART- transportation & crediting to nearest Per As per site
A - 21 GETCO’s store or substation as per instruction MT execution
Cutting of stubs of old tower to be dismantled
including breaking of chimney/cutting of RCC
PART- upto 450mm below ground level & crediting Per As per site
A - 22 stubs & steel bars to GETCO's store or tower execution
substation including back-filling & leveling of
site as per inst. of EIC.
Work of Painting of Line name, Location No.,
PART- two coat Painting Color code of desired As per site
A - 23 length and telephone no. on Tower Leg with execution
letter of Gujarati language using ISI marked
Paint as per instruction of EIC including
Supply of paints and other require materials.
a) All four legs - For 4 Nos. of Line (M/C)
b) All four legs - For 2 Nos. of Line (D/C)
c) Two legs - For 1 Nos. of Line (S/C)
Labour Cost - Part-B Stringing Work
SOR Description. Unit. Rate Qty
Stringing of ONE ground wire including laying,
jointing, tensioning, clamping with accessories,
PART-B As per site
1 jumpering, & sister wire, vibration damper RKM
earth bond etc.& including tree cutting as per
instruction of EIC.
Stringing of ACSR/ AAAC 3 (Three) conductors
for single circuit including laying, jointing,
tensioning, clamping with armour rods, hoisting
PART-B of insulator string fixing of jumpers, dampers As per site
-3 etc. & with required tree cutting on entire execution
length for adequate clearances / safe charging
of line, as per instruction of EIC - ACSR Dog
Stringing of ACSR/ AAAC 3 (Three) conductors
for single circuit including laying, jointing,
tensioning, clamping with armour rods, hoisting
PART-B of insulator string fixing of jumpers, dampers As per site
-3 etc. & with required tree cutting on entire execution
length for adequate clearances / safe charging
of line, as per instruction of EIC - ACSR Panther
-do- but for Stringing of ACSR/ AAAC 6 (SIX)
PART-B As per site
4 conductors for double circuit - For ACSR Dog RKM
-do- but for Stringing of ACSR/ AAAC 6 (SIX)
PART-B As per site
5 conductors for double circuit - For ACSR Panther RKM
-do- but for Stringing of ACSR/ AAAC
PART-B As per site
6 (Twelve) conductors for Multi circuit - For ACSR RKM
-do- but for Stringing of ACSR/ AAAC
PART-B As per site
7 (Twelve) conductors for Multi circuit - For ACSR RKM
Panther Conductor
PART-B Work as per Item Sr. No. 2 but for HOT LINE
-6 stringing work - For ACSR Dog conductor
PART-B As per site
a) Upto 5 KM RKM
PART-B Work as per Item Sr. No. 2 but for HOT LINE
-6 stringing work - For ACSR Panther conductor
PART-B As per site
a) Upto 5 KM RKM
Work as per Item Sr. No. 1 but for special river
PART-B crossing section from one anchor tower to As per site
-7 another anchor tower - For ACSR Dog conductor execution
& ACSR Panther conductor.
Stringing of ONE ground wire including laying,
jointing, tensioning, clamping with accessories,
PART-B As per site
11 jumpering, & sister wire, vibration damper RKM
earth bond etc.& including tree cutting as per
instruction of EIC. but for Hot line stringing
Stringing of ACSR/ AAAC 3 (Three) conductors
for single circuit including laying, jointing,
tensioning, clamping with armour rods, hoisting
of insulator string fixing of jumpers, dampers
PART-B etc. & with required tree cutting on entire As per site
- 10 length for adequate clearances / safe charging execution
of line, as per instruction of EIC - ACSR Dog
Conductor, but for special river crossing section
from one anchor tower to another anchor
tower.- For ACSR Dog conductor
Stringing of ACSR/ AAAC 3 (Three) conductors
for single circuit including laying, jointing,
tensioning, clamping with armour rods, hoisting
of insulator string fixing of jumpers, dampers
PART-B etc. & with required tree cutting on entire As per site
- 10 length for adequate clearances / safe charging execution
of line, as per instruction of EIC - ACSR Dog
Conductor, but for special river crossing section
from one anchor tower to another anchor
tower.- For ACSR Panther conductor
Stringing of ACSR/ AAAC 6 (SIX) conductors for
PART-B double circuit - For ACSR Dog Conductor, but for As per site
- 11 special river crossing section from one anchor execution
tower to another anchor tower.
Stringing of ACSR/ AAAC 6 (SIX) conductors for
PART-B double circuit - For ACSR Panther Conductor, As per site
- 11 but for special river crossing section from one execution
anchor tower to another anchor tower.
Stringing of ACSR/ AAAC 12 (Twelve) conductors
PART-B for Multi circuit - For ACSR Dog Conductor, but As per site
- 12 for special river crossing section from one execution
anchor tower to another anchor tower.
Stringing of ACSR/ AAAC 12 (Twelve) conductors
PART-B for Multi circuit - For ACSR Panther Conductor, As per site
- 12 but for special river crossing section from one execution
anchor tower to another anchor tower.
Dismantling of conductors and line materials of
existing line including transportation &
creaditing to nearest GETCO's store or
substation as per instruction of EIC.:
(A) COLD CONDITION - For ACSR Dog conductor
- 3 Conductors (S/C) RKM
- 6 Conductors (D/C) RKM
- 13 As per site
- 1 Earthwire RKM
(B) HOT LINE CONDITION- For ACSR Dog
- 3 Conductors (S/C) RKM
- 1 Earthwire RKM
Dismantling of conductors and line materials of
existing line including transportation &
creaditing to nearest GETCO's store or
substation as per instruction of EIC.:
(A) COLD CONDITION - For ACSR Panther
PART-B - 3 Conductors (S/C) RKM
- 6 Conductors (D/C) RKM
(B) HOT LINE CONDITION- For ACSR Panther
- 3 Conductors (S/C) RKM
Termination and connection for making LOOP-
IN-LOOP-OUT arrangement with existing line
during specified outage including restringing of
existing conductors OR dismantalling / new
stringing for making LILO arrangements with
PART-B Job As per site
20 existing line or for change over line as per
- 14 Work execution
approved LILO arrangement in profile as per
instruction of EIC in COLD CONDITION and
dismentalled materials to be credited to near by
GETCO's store or sub station as per inst. of EIC.
- For ACSR Dog conductor
Termination and connection for making LOOP-
IN-LOOP-OUT arrangement with existing line
during specified outage including restringing of
existing conductors OR dismantalling / new
stringing for making LILO arrangements with
PART-B Job As per site
21 existing line or for change over line as per
- 14 Work execution
approved LILO arrangement in profile as per
instruction of EIC in COLD CONDITION and
dismentalled materials to be credited to near by
GETCO's store or sub station as per inst. of EIC.
- For ACSR Panther conductor
Work of attending the fault of Broken conductor
/ conductors and/or Snapping from tower only
at any one location (Tension to Tension
Location), in COLD LINE CONDITION including
mobilization of man power at site. Required
PART-B materials i.e., H/W and Conductor will be Job As per site
- 22 provided by GETCO at free of cost. Also, Work execution
materials to be taken from the GETCO's store
and after using of the materials, balanced and
old dismantled materials to be credited to the
- Tower Line - For ACSR Dog conductor
Work of attending the fault of Broken conductor
/ conductors and/or Snapping from tower only
at any one location (Tension to Tension
Location), in COLD LINE CONDITION including
mobilization of man power at site. Required
PART-B materials i.e., H/W and Conductor will be Job As per site
- 22 provided by GETCO at free of cost. Also, Work execution
materials to be taken from the GETCO's store
and after using of the materials, balanced and
old dismantled materials to be credited to the
GETCO's store.- Tower Line - For ACSR Panther
Work of attending the fault of Broken of
conductor / conductors and/or Snapping from
H-Frame only at any one location (Tension to
Tension Location), in COLD LINE CONDITION
including mobilization of man power at site.
PART-B Required materials i.e. H/W and Conductor will Job As per site
- 23 be provided by GETCO at free of cost. Also, Work execution
materials to be taken from the GETCO's store
and after using of the materials, balanced and
old dismantled materials to be credited to the
- H-Frame Line - For ACSR Dog conductor
Work of attending the fault of Broken of
conductor / conductors and/or Snapping from
H-Frame only at any one location (Tension to
Tension Location), in COLD LINE CONDITION
including mobilization of man power at site.
PART-B Required materials i.e. H/W and Conductor will Job As per site
- 23 be provided by GETCO at free of cost. Also, Work execution
materials to be taken from the GETCO's store
and after using of the materials, balanced and
old dismantled materials to be credited to the
GETCO's store.- H-Frame Line - For ACSR
Panther conductor
Work of attending the fault of Broken of
conductor / conductors and/or Snapping from
tower only at any one location (Tension to
Tension Location), in HOT LINE CONDITION
including mobilization of man power at site.
PART-B Required materials i.e. H/W and Conductor will Job As per site
- 24 be provided by GETCO at free of cost. Also, Work execution
materials to be taken from the GETCO's store
and after using of the materials, balanced and
old dismantled materials to be credited to the
- Tower Line - For ACSR Dog conductor
Work of attending the fault of Broken of
conductor / conductors and/or Snapping from
tower only at any one location (Tension to
Tension Location), in HOT LINE CONDITION
including mobilization of man power at site.
PART-B Required materials i.e. H/W and Conductor will Job As per site
- 24 be provided by GETCO at free of cost. Also, Work execution
materials to be taken from the GETCO's store
and after using of the materials, balanced and
old dismantled materials to be credited to the
GETCO's store.- Tower Line - For ACSR Panther
Stringing of HTLS - 3 (THREE) conductors for
single circuit including laying, jointing,
tensioning, clamping with armor rods, hoisting
PART-B As per site
28 of insulator string fixing of jumpers, dampers RKM
etc. & with required tree cutting on entire
length for adequate clearances / safe charging
of line. – COLD Line- For ACSR Dog conductor
Stringing of HTLS - 3 (THREE) conductors for
single circuit including laying, jointing,
tensioning, clamping with armor rods, hoisting
PART-B of insulator string fixing of jumpers, dampers
- 29 etc. & with required tree cutting on entire
length for adequate clearances / safe charging
of line. – COLD Line- For ACSR Panther
Stringing of HTLS - 6 (SIX) conductors for single
circuit including laying, jointing, tensioning,
clamping with armor rods, hoisting of insulator
30 string fixing of jumpers, dampers etc. & with RKM 1112071 N.A.
required tree cutting on entire length for
adequate clearances / safe charging of line. –
COLD Line - For ACSR Dog conductor
Stringing of HTLS - 6 (SIX) conductors for single
circuit including laying, jointing, tensioning,
clamping with armor rods, hoisting of insulator
31 string fixing of jumpers, dampers etc. & with RKM 1275167 N.A.
required tree cutting on entire length for
adequate clearances / safe charging of line. –
COLD Line - For ACSR Panther conductor
Labour Cost - Part-C H-Frame
SOR Description. Unit Rates Qty
Erection of ‘H’ frame structure with
channels, bracings, clamps etc. for
‘A’/’B’ type location including
excavation in Normal/ black cotton soil
(Dry / Wet / submerged) and back filling
of earth and leveling of the land as per
inst. of EIC. Also with supply of bolts, nuts
and painting of the complete structure
PART-C - As per site
1 including required tree cutting. Before No.
erection, one coat of good quality primer
must be applied to the complete
structure and black paint of standard
make should be applied up to 3 mtr. from
bottom. After erection, two coats of
aluminium paint of Asian / Burger /
Nerolac make shall be applied to the
complete structure.
As per Item Sr. No. 1, but for angular
PART-C - As per site
2 location upto 60 Degree deviation / dead No.
end – ‘C’ type.
Erection of 105 Lbs./ Rail or RSJ 150 x
PART-C - As per site
3 mm size single pole as per work indicated No.
in Item Sr. No.
Stringing of ACSR/AAAC - 3 (Three)
PART-C - Route As per site
4 conductors for single circuit including
5 Km. execution
laying, jointing, tensioning, clamping
with armour rod, hoisting of insulator
string, jumpering, fixing of dampers etc.
complete as per specification including
required tree cutting with adequate
clearance and safe charging of Line and
as per instruction of EIC. - For ACSR Dog
Stringing of ACSR/AAAC - 3 (Three)
conductors for single circuit including
laying, jointing, tensioning, clamping
with armour rod, hoisting of insulator
PART-C - string, jumpering, fixing of dampers etc. Route As per site
5 complete as per specification including Km. execution
required tree cutting with adequate
clearance and safe charging of Line and
as per instruction of EIC. - For ACSR
Panther conductor
Grounding of above ‘H’ frame/single pole
structure with pipe type earthing as per
drawing including excavation by augering
& back filling & supply of all materials
PART-C - As per site
6 like 32mm dia. heavy duty 3 mtr. long GI Set.
pipe (B-Class) & G.I. flat of 50x6mm size
including supply of bolt nuts, salt, coal,
charcoal etc. as per drawing. and as per
instruction of EIC.
Erection of stay set complete including
excavation with stay clamp, turn buckle,
PART-C - As per site
7 eye bolt, anchor rod and binding with 7/8 Set.
or 7/10 SWG earth wire, as per
instruction of EIC.
Concreting of foundation for all the
structures, with M15 mix. including
concreting of stay sets with supply of
materials like cement of 43 grade, sand,
metal etc. with muffing (400 mm Dia x
PART-C - As per site
8 300 mm Ht.) above ground level for all CU.M.
the structures.
After completion of concrete work,
watering to concerte is to be done as per
instruction of EIC. Rates are inclusive of
supply of GETCO approved Cement only.
Tack welding of nuts at three places on
the nuts diametrically fitted to ‘A’, ‘B’
PART-C - and ‘C’ TYPE structures and applying red Per As per site
9 oxide & zinc rich paint on it immediately Bolt. execution
after tack welding, as pre instruction of
Transportation of Girder / Rail from
PART-C - GETCO’s nearest / any Store Centre to As per site
10 one end of the line including loading and execution
unloading and as per instruction of EIC.
up to 70 KMs (Upto 6 MT) - Lumsum
(To be executed / considered for a Job /
particular Job / Lot while weight is not Lot
increasing 6 MT per Trip )
(ii) upto 70KMs (Beyond 6 MT) - proportionate Per MT
(iii) Beyond 70KMs.
Conversion of ‘A’ type ‘H’ frame
structure into ‘B’ type ‘H’ frame
structure in existing line by replacing
necessary channels etc. and termination
and restringing of Dog or Panther
conductors for making LILO arrangement
with existing line or for change over of
line during availability of specified
PART-C - work As per site
11 outage only.Supply of require size GI N/B
11 (Per execution
will be in the scope of contractor. Item
also include transportation of new B type
channel from store / Substation as per
availability to site and to be creadit the
dismental old channel / any hardware
and other materials if replaced to TR
dept with necessary inventory as per
instruction of EIC.
Dismantling of ‘A’ & ‘B’ type ‘H’ frame
structure by breaking of muffing upto
mm depth from ground level and cutting
PART-C - the girders from 450 mm depth from As per site
12 ground level by gas cutting & crediting execution
the material to GETCO Store or
Substation including transportation as
instructed by Engineer in-charge.
PART-C - As per site
13 - do – but for ‘C’ type structure. Loc.
Dismantling of all three conductors and
line materials such as insulators,
hardwares etc. and crediting to the
PART-C - GETCO’s Store or Substation including Route As per site
14 transporation as per instruction of Km. execution
Engineer in-charge with submission of
pole wise inventory for preparing
Providing & fixing of NP with name of line
PART-C - As per site
15 / DP including supply of bolts & nuts and Loc.
tack welding/ punching as per drawings.
Providing & fixing of ACD on Single Pole
PART-C - As per site
16 girders as per drawing and as per Loc.
instruction of EIC.
Providing & fixing of ACD on A / B Type
PART-C - As per site
17 H-Frame as per drawing and as per Loc.
instruction of EIC.
Providing & fixing of ACD on C Type H -
PART-C - As per site
18 Frame as per drawing and as per Loc.
instruction of EIC.
Work of Painting of Line name, Location
No., two coat Painting Color code of
desired length and telephone no. on
PART-C - As per site
19 Single Pole girder with letter of Gujarati per loc
language using ISI marked Paint as per
instruction of EIC including Supply of
paints and other require materials.
Work of Painting of Line name, Location
No., two coat Painting Color code of
desired length and telephone no. on H-
PART-C - As per site
20 Frame (2 Leg) with letter of Gujarati per loc
language using ISI marked Paint as per
instruction of EIC including Supply of
paints and other require materials.
The rate indicated above includes taking delivery of all stringing material from
1 contractor store/ GETCO’s store keeping them in safe custody and transporting the
same to erection site.
For any crediting of material related work, agency has to submit the original gate
2 pass copy / CR copy with required documents as per inst. and as per requirement of
EIC or when demanded.
If condcutor provided by GETCO, Contractor has to retuned back empty steel drums
at GETCO's store immediately on complition of stringing work as per instruction of
EIC. If fail to submit in given time period the necessary action will be imposed by
concered authority.
4 All above rates are excluding GST
Superintending Engineer
I am / we are willing to pay the cost of old line material stated above at
--------------------------------------- Percentage BELOW / ABOVE.
The estimated cost for all above lines including GST & other taxes as
The total amount of old line materials cost that will be Paid
The total amount of old line materials cost that will be Paid
with above percentage is Rs. -------------------- (in figures) -------------
-------------------------(in words) including GST & other taxes as
Note: Evaluation of above quoted price shall be done on the basis of overall
maximum financial benefit to the Company i.e. the Bidder offering/quoting
difference of total cost of Schedule B, Lot - I (b) & total cost of Schedule
B, Lot - I (a) maximum shall be the lowest for this particular Lot No.I.
Signature of Authorised
representative Company /Agency
Name of Tendering Company. --------------------
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
TCNS-ET-132 66kV Tower line emergency restoration Tech Bid.pdf
TCNS-ET-132 66kV Tower line emergency restoration pricebid.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .