Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | ₹16.3 L Quoted ₹16.9 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED |
| 2 | L2₹18.3 L+₹1.4 L (8.50%)Rejected-AOC | ₹18.3 L+₹1.4 L (8.50%) | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 3 | L3₹18.9 L+₹2.1 L (12.1%)Rejected-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | ₹18.9 L+₹2.1 L (12.1%) | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 4 | L4₹19.2 L+₹2.3 L (13.4%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹19.2 L+₹2.3 L (13.4%) | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 5 | L5₹19.8 L+₹2.9 L (17.0%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹19.8 L+₹2.9 L (17.0%) | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
30 May 2022, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR REPLACEMENT OF ELECTRIC WIRING IN MD ACCN AND REPAIR MAINTENANCE OF CEILING FANS EXHAUST FANS AND GEYSERS AT MIL STN GANDHINAGAR
2022_MES_522949_1
GE(A)/GNR/TOKEN/02 of 2022-23
Open Tender
Civil Works - Others
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹36,000
Yes
21 Jun 2022
9 May 2022
1 Jun 2022
9 May 2022
30 May 2022
17 May 2022
9 May 2022 - 16 May 2022
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete, including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets, etc excluing light fittings etc, removing materials to store for keeping in safe custudy or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One multi purpose socket 5 Amps, Independent board.
(c) One multi purpose socket 5 Amps, on the same board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F, in repair, lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F, in repair, switch piano, flush button single pole, one way 5 Amps complete all as specified and directed.
S&F, in repair, switch piano flush button single pole, one way 15 Amps complete all as specified and directed.
S&F, in repair, socket outlet multipurpose, 3 pin, 5 &15 Amps flush type complete all as specified and directed.
S&F, in repair, socket outlet 2 in1, 3 pin, 5 Amps, flush type complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 5 & 15 Amps flush type complete all as specified and directed.
S&F, in repair, switch socket combination 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed.
S&F, in repair, Ceiling rose, PVC/poly carbonate, isolated body three terminals, complete all as specified and directed
S&F, in repair, Distribution Board SPN 8 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S&F, in repair, Distribution Board Power line VTPN , 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, suitable for 4 pole MCCB 63 Amps for incoming supply and 12 Nos single pole MCBs 6 to 32 Amp for out going supply complete all as specified and directed.
S&F, in repair, for ceiling fan regulators, Electronic step type type, AC, 230 Volts complete all as specified and directed.
S&F, in repair, MCB’s single pole, 6 to 32 Amps 240 volts with ‘C’ curve,10KA, fixed in sheet metal board complete including connecting.
S&F, in repair, MCB’s SPN 32 Amps 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
S&F, in repair, MCCB Three pole and neutral 10KA, 63 Amps, 415Volts. complete all as specified and directed.
S&F, in repairs, LED light fitting, 1x20W, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fix LED light fitting 1 x 10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
Supply & Fix in repair LED type Bldg security light fittings, IP-66, 25W, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics including taking out old unsv fitting of any type complete all specified and directed.
M & L in replacement sub-main wiring with 2 single core 4 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC casing and capping ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 4.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
M&L for earthing and testing complete, in repair, with galvanized iron earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge plate at a depth not less than 1.5M below normal ground level connected to and including earth lead GI wire 4.0 mm dia, by means of bolts and nuts, check nuts and washers etc., made of GI and connected to panel/distribution board and earthing test point and earth dolly all as shown in elect plate No.3 of SSR Part-1 including necessary earth work,excavation PCC chamber cover with handle (PCC 1:2:4) incl 20mm dia GI pipe of medium grade for watering and 15mm dia GI pipe of light grade for protection of earthing lead ,wire mesh, funnel, charcoal dust,common salt,copper lugs etc all as specified and directed .
Supply, installation, commissoning and testing, factory made, LT Metal Box, wall mounted board made out of CRCA sheet of 2 mm thick indoor type totally enclosed weather, dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron (40x6 mm and 6" long) 04 No clamp welded to 40mm x 40mm x 5mm size angle iron frame alround panel body duly grouted on wall, 415 volts 3 phase, 4 wire AC 50 HZ having aluminium bus bar insulated with PVC sleeves, space for fixing single phase KWH electric meter of suitable capacity 04 Nos, copper lugs, spacers, mounting channels, rubber gasket, locking knobs, hylam sheet pieces, PVC shrinkable sleeves, nuts and bolts, washers etc and suitable size single core copper wire connections, suitable compartments and epoxy powder spray paint with primer complete all as specified including the following accessories including taking down old unserviceable distribution board, taking down and refixing serviceable electric KWH meter in new panel (all as per sample) complete comprising the followings :- (a) Incoming supply:- (i) MCCB, 415 Volts, 4 Pole, 25 KA breaking capacity of 63 Amps - 01 No. (ii) R-Y-B phase, LED indicating lamp - 03 Nos (iii) 200 Amp TPN main aluminium bus bar (b) Outgoing supply:- (i) MCB, SPN, 40 Amp, 10 KA = 04 Nos (ii) Space for mounting single phase energy meter - 04 Nos (iii) Copper cable 6 Sqmm wire and open terminals for all feeders.
Opening (De-assembling) of the ceiling fan, 1200mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of appropriate gauge, slot insulation, heat varnishing, greasing and re-assembling including replacement of split pin and flexible twisted copper cable of 23/0.0076 gauge and testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 2.5 Mfd suitable for 1200 mm sweep ceiling fan.
Supply only ball bearing suitable for 1200mm sweep ceiling fan.
Supply only gun metal bush suitable for 1200mm sweep ceiling fan of appropriate make.
S&F, in repair, PVC canopy set (Upper & Lower) suitable for ceiling fans complete all as specified and directed.
S&F, in repair, MS hanging clamp with rubber bush, bolts, nuts & washer with split pin suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
Taking down of ceiling fan 1200 mm sweep from existing position/hook, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 250 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 300 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
Opening (De-assembling) of exhaust fan 450 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 4.0 Mfd suitable for exhaust fan.
Supply only ball bearing suitable for 450mm sweep exhaust fan complete.
Supply only gun metal bush suitable for 450mm sweep exhaust fan complete.
Taking down exhaust fan of size 450 mm sweep from existing position, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
Disconnecting carefully water and electric connection from storage type water heater of 25 ltr cap of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing and re-fixing in existing position complete all as specified and directed. Note:- (i) Heating element, thermostat, air release valve, safty valve, indicating lamp and syphone assembly shall be measured and paid under relevant items as "Supply Only". (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
Supply only, heating element of 1.5 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
Supply only, heating element of 2.0 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
Supply only, thermostat assembly for geyser, tempetrature setting up to 85 degree centigrade, ISI marked complete all as specified and directed.
S&F, in repair, indicating lamp suitable for existing slot of geyser complete all as specified and directed.
S&F, in repair, 15mm bore 600mm long, PVC connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair, semi circular bottom cover plate of 25/50 ltr capacity geyser duly painted of appropriate make complete all as specified and directed.
S&F, in repair, wall mounting fan 400mm sweep electrically operated swing type suitable for working on 240 V, Single Phase AC Supply complete all as specified and directed.
S&F, in repair, 3 pin plug top of 15/16 Amp, 240 V AC supply ISI marked of Make Bajaj/Anchor or equivalent make as specified in Appx 'C'.
S&F, in repair, 3 pin plug top of 5 Amp, 240 V AC supply ISI marked of Make Bajaj/Anchor or equivalent make as specified in Appx 'C'.
Supply only Geyser assembly 8/9 complete all as specified and directed.
S&F, in repair, PVC insulated and PVC sheathed cable 3 core, 2.5 Sqmm, multistandard copper conductors for water coolers/ refrigerators complete all as specified and directed.
S&F, in repair, PVC insulated and PVC sheathed cable 3 core, 6 Sqmm, multistandard copper conductors for water coolers/ refrigerators complete all as specified and directed.
TRIMURTHI ENTERPRISES
Electromech Engineers
ARTI CONSTRUCTION
Abhishek Enterprises
Shree Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .