| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC 19 PAOTA C ROAD JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹37.4 L+₹2.3 L (6.49%)Rejected-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Rejected-AOC Not lowest bidder | |
| 3 | L3₹37.9 L+₹2.7 L (7.77%)Rejected-AOC 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-AOC Not lowest bidder | |
| 4 | L4₹39.5 L+₹4.4 L (12.4%)Rejected-AOC | L4 | Rejected-AOC Not lowest bidder | |
| 5 | L5₹39.7 L+₹4.6 L (13.0%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L5 | Rejected-AOC Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 May 2025, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No 2 Jodhpur AF Stn Jodhpur
Repair/maint of water supply installation and allied CI/GI pipeline work under AGE EM GE AF No2 Jodhpur in domestic area of AF Stn Jodhpur and Repair/replacement/maint of old vintage GICI water pipe line including allied accessories and works at Sahu
2025_MES_705359_1
8519/E8
Open Tender
Construction Works
Item Rate
180 days
GE (AF) No 02 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹90,000
Yes
21 Jun 2025
24 Apr 2025
23 May 2025
24 Apr 2025
21 May 2025
8 May 2025
24 Apr 2025 - 1 May 2025
Amount
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipe lines, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in hard/dense soil/rocks & getting out old brick or precast cable cover complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
Taking up or down steel water tubing and connections of 15 mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and as directed. Note : Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
All as per serial item No. 4.00 here-in-before but 20 mm dia bore
All as per serial item No. 4.00 here-in-before but 25 mm dia bore
All as per serial item No. 4.00 here-in-before but 40 mm dia bore
All as per serial item No. 4.00 here-in-before but 50 mm dia bore
All as per serial item No. 4.00 here-in-before but 80 mm dia bore
All as per serial item No. 4.00 here-in-before but 100 mm dia bore
All as per serial item No. 4.00 here-in-before but 150 mm dia bore
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings complete, fixed to walls and ceilings or laid in floors/trenches, complete all as specified and directed.
All as per serial item No. 12.00 here-in-before but 20 mm dia bore
All as per serial item No. 12.00 here-in-before but 25 mm dia bore
All as per serial item No. 12.00 here-in-before but 40 mm dia bore
M&L for galvanized steel water tubing medium grade of 50mm bore with & including all fittings complete, laid in trenches, complete all as specified and directed.
All as per serial item No. 16.00 here-in-before but 80 mm dia bore
Supply, laying, jointing and testing centrifugally cast Ductile Iron spun pressure pipes (Class K7) of 100 mm bore with internal cement mortar lining and external zinc coating (130 gm/sqm minimum) and bituminous finish layer (minimum thickness 70 microns) with socket & spigot ends (ISI marked) conforming to IS 8329 suitable for push on rubber gasket joint/tyton joints complete laid in trenches all as specified & as directed. Note :- (i) DI fittings shall be measured & paid for separately under relevant items of this Schedule. (ii) Pipe shall be laid in trenches already excavated for taking out GI pipe line. No extra Earth work shall be admissable.
All as per serial item No. 18.00 here-in-before but 150 mm dia bore.
S&F in replacement 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete, all as specified & directed.
All as per serial item No. 20.00 here-in-before but 25 mm dia bore.
All as per serial item No. 20.00 here-in-before but 40 mm dia bore
All as per serial item No. 20.00 here-in-before but 50 mm dia bore
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80 mm bore, ISI marked with IS 14846 : 2000, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete, all as specified & directed.
All as per serial item No. 24.00 here-in-before but 100 mm dia bore
All as per serial item No. 24.00 here-in-before but 150 mm dia bore
S&F in replacement cast iron, Non return valve/reflux valve with rubber seat flanged type with by pass arrangement suitable for 80 mm bore pipe, ISI marked, conforming to IS – 5312: 2004 with atainless steel spindle, CI agte with brass nuts, bolts, washers and jointing with necessary rubber gasket etc., complete all as specified & directed
All as per serial item No. 27.00 here-in-before but 100 mm dia bore
Supply and fixing DI fittings (ISI marked) upto 150 mm bore, conforming to IS: 9523 : 2000, such as bends (any type, radius & angle), Tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket & spigot), collars, caps & plugs suitable for spigot & socketed pipes, complete, all as specified & directed.
M&L for construction of brick masonary valve pit of internal size 60cm x 60cm x60cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mm x40mm x6mm, MS Sheet cover of 3mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surface an dgrouting the frame in PCC 1:2:4, type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock including dismantling of old existing unserviceable vale pit etc., complete all as specified & directed. Notes:- (i) Brick wall shall be 230mm thick built in CM 1:4. (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8)type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surface of valve pit. (vi) Depth of valve pit shall be reckoned from thetop of PCC in foundation.
All as per serial item No. 30.00 here-in-before but internal size 90cm x 90cm x 90cm
All as per serial item No. 30.00 here-in-before but internal size 150cm x 150cm x 90cm
M&L for ‘D’ joint suitable for DI/CI/GI pipe size 50 mm dia bore including excavation work and other fittings as required including testing at site complete all as specified & directed.
All as per serial item No. 33.00 here-in-before but 80 mm dia bore
All as per serial item No. 33.00 here-in-before but 100 mm dia bore
All as per serial item No. 33.00 here-in-before but 150 mm dia bore
S&F in repair 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed all as specified and directed.
All as per serial item No. 37.00 here-in-before but 20 mm dia bore
All as per serial item No. 37.00 here-in-before but 25 mm dia bore
Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
Material and labour in repair for earthling complete with copper plate electrode 60cmx60cmx3.15mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead copper strip 20 x 3 mm by means of bolts, nuts, check-nuts and washers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc., all as specified and directed.
S&F in replacement 80mm dia butterfly valve complete all as specified and directed by Engineer-in-charge.
All as per Srl item No. 42.00 above but 100 mm dia bore.
All as per Srl item No 42.00 above but 150 mm dia bore.
All as per Srl item No 42.00 above but 200 mm dia bore.
Preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing paint of Elect motor with pump including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F in replacement contactor ML-2, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type ML 2) Cat Part No SS90701 or equivalent of Siemens / English Electric / ABB / Legrand.
S&F in replacement contactor ML-3, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type ML 3) Cat Part No SS90721 or equivalent of Siemens / English Electric / ABB / Legrand.
S&F in replacement contactor MNX80, 3 phase 415 volts having auxiliary contracts suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge.Make: L&T / Siemens / English Electric / ABB / Legrand.
S&F in replacement contactor MNX110, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge. Make : L&T / Siemens / English Electric / ABB / Legrand.
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm, single phase, as suitable range, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement overload relay, suitable for 10 HP to 40 HP motor, 3 phase, 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in replacement overload relay, suitable for 50HP to 75 HP , motor 3, phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 15 HP pump set ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 50 HP pump set ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in replacement fully automatic star delta starter type ML2 FASD having relay of range 20 - 32 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No SS90705 or equivalent Crompton Greaves / ABB / Schneider / Seimens
S&F in replacement fully automatic star delta starter type for 10 HP having relay of range 08 - 12 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge.
S&F in replacement DOL starter range 13 - 22 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part NoSS96228 or equivalent Crompton Greaves / ABB / Schneider / Seimens
S&F in replacement DOL Starter range 28 - 42 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part NoSS96228 or equivalent Crompton Greaves / ABB / Schneider / Seimens
S&F in replacement single phase preventer type SDz5, SPPR + Timer, 415 V including necessary copper connection, lugs etc complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No XM818090000 or equivalent in ABB.
S&F in replacement electronic timer type ET100, 110 / 240V, 50 HZ including necessary electric connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No SE 92003 or equivalent in ABB
S&F in replacement on / off switch (push button) complete all as specified & as directed by Engineer-in-charge.
S&F in replacement indicating lamp with holder and cover as per existing complete all as specified & as directed by Engineer-in-charge.
S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make: Legrand Cat Part No. DPX 160 420055 or equivalent in L&T / Schneider / Standard
All as per item No. 68.00 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt Make: Legrand Cat Part No. DPX 160 420056 or equivalent in L&T / Schneider / Indo asian
All as per item No. 68.00 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 25 KA, 415 Volt Make: Legrand Cat Part No. DPX 160 420057 or equivalent in L&T / Schneider / Indo asian
All as per item No. 68.00 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt Make: Legrand Cat Part No. DPX 250 420249 or equivalent in L&T / Schneider / Indo asian
KRISHNA CONSTRUCTION COMPANY (BID ID -3299747)
GITANSH ENGINEERS AND COMPANY (BID ID -3297264)
L C ASSOCIATES (BID ID -3301360)
Nvimal Engineers and Contractor (BID ID -3296506)
SANJOLI CONSTRUCTION COMPANY (BID ID -3301719)
Shri Electrical Enterprises (BID ID -3299672)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .