| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.8 LAccepted-Finance | 1 | Accepted-Finance L1 LOWEST BIDDER | |
| 2 | 2₹26.7 L+₹93,982 (3.65%)Rejected-Finance | 2 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 3 | 3₹27.0 L+₹1.3 L (4.87%)Rejected-Finance | 3 | Rejected-Finance RATES ARE ON HIGHER SIDE |
Tender Value
₹27 L
EMD Value
₹27,000
Closing Date
28 Feb 2020, 5:00 pmClosed
SE ETC AZAMGARH
220KV S/S COLONY HAFIZPUR AZAMGARH
DIVERSION OF 132 KV KOILSA-ATRAULIA LINE FOR CONSTRUCTION OF GORAKHPUR LINK EXPRESSWAY BY UPEIDA INCLUDING CONSTRUCTION OF LINE AND DISMANTLING WORK OF OLD LINE, UNDER ELECTY. TRANS. DIVISION AZAMGARH
2020_UPTCL_430988_1
128/AETC/2019-20
Open Tender
Electrical Works
Item Wise
120 days
AZAMGARH
UTR SLIP OF EMD TENDER FEE PAN CARD GST CERTIFICATE WORK EXPERIENCE etc.
2 documents required · 2 mandatory
₹3,186
SE ETC UPPCL AZAMGARH
₹27,000
5 Mar 2020
4 Feb 2020
29 Feb 2020
4 Feb 2020
28 Feb 2020
4 Feb 2020
4 Feb 2020 - 28 Feb 2020
Amount
Annexure-I Detail survey including preparation of schedule of material, marking of location ( route length) GPS survey of line with cordinates of each tower ( the length of line shall be authenticate by GPS survey.
Check Survey and final peg marking ( route length)
Cost of excavation of 132 KV tower foundation pits including all earth work, back filling and leveling etc.
Setting of stubs including all foundation work but excluding the cost of concerting and excavation ( rate per location) for following 132 KV DC towers. (i) DA No. 0.00 (ii) DB No. 2.00
(iii) DC
Cost of concreting for all types of 132 KV towers foundation including cost of cement, Dewatering, shoring and shutering, forming, curing but excluding cost of reinforcement brass with 1:2:4 mix concrete. PCC/RCC
Erection of super structures of 132 KV DA, DB and DC towers and their extension where ever required including all works above ground excluding hoisting insulator, hardware and accessories but including fitting of danger, number, phase plate, bird gard and fixing and punching.
Tack welding of all the bolts two the height of one section of the towers are 5 meters from gound level which ever is higher with 3 tacks at 1200 seperation of minimum 10 mm thickness with 10/12 mm electrode and application of zinc rich alluminium paints on the affected surface including cost of all materials.
Laying, stringing, tensioning, clamping, jointing etc. of ACSR panther conductor including hoisting of insulators, fitting of all necessary hardware and accessories. Fitting armour rods, vibration damper etc on all three phases of 132 KV SC line.
Laying, stringing, tensioning, clamping, jointing etc. of 7/10 SWG ground wire including fitting of all necessary hardware and accessories on 132 KV lines.
Grounding work including earthwork etc for pipe type grounding, including cost of Coke and salt.
Installation of steel re-inforcement bars in RCC foundation including cost of steel re-informent bars with cutting. bending, placing, binding etc.
Destringing of ACSR panther conductor including removal of all hardware and fittings, insulators, and there after transportation of dismantled material from site to UPPTCL store.
Destringing of earthwire including removal of all hardware and fittings, there after transportation of dismantled material from site to UPPTCL store.
Dismantling of 132 KV DC towers by de-tack welding of nuts and bolts and thereafter weighing, transportaton of dismantled material from work site to UPPTCL Store.
Annexure-II (A) Tower Accessories (i) Number Plate
(ii) Danger Plate
(iii) Phase Plate set (RYB)
(iv) Birdgaurd No. 0.00 (v) Earthing Set No. 4.00
(B) Conductor Accessories (1) Vibration damper for ACSR Panther conductor
(2) M.S. Joint suitable for ACSR Panther conductor
(3) Repair sleeve suitable for ACSR Panther conductor (4) P.A. Rod suitable for ACSR Panther conductor No. 0.00
(C) Ground wire Accessories (1) Suspension Clamp suitable for 7/10 SWG G.S. earthwire No. 0.00 (2) Tension Clamp suitable for 7/10 SWG G.S. earthwire
(3) M.S. Joint suitable for 7/10 SWG G.S. earthwire
(4) Vibration damper suitable for 7/10 SWG G.S. earthwire
(5) Copper wound
(D) Hardware fittings (1) Single suspension fittings for ACSR Panther conductor No. 0.00 (2) Single tension fittings for ACSR Panther conductor
(3) Double tension fittings for ACSR Panther conductor
(E) 120 KN Proceline Type Disc Insulator (F) 70 KN Proceline Type Disc Insulator No. 0.00
M/S SHIV MAKHAN ENTERPRISES
Rama Power construction
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .