Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹29.9 L+₹5.4 L (21.8%)Rejected-Finance 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹32.0 L+₹7.5 L (30.4%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹32.5 L+₹7.9 L (32.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 May 2019, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
AS PER BOQ AND TENDER DOCUMENTS
2019_MES_245899_1
GE FORT KOCHI 8618/E8
Open Tender
Civil Works
Item Rate
240 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹60,000
Yes
22 May 2021
13 Apr 2019
7 May 2019
13 Apr 2019
6 May 2019
26 Apr 2019
14 Apr 2019 - 25 Apr 2019
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard and dense soil all as specified and as directed.
M & L Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified.
M&L sand cushioning in trenches using clean dry river sand for cable cushioning all as specified and as directed. Note : Thickness of sand cushioning after punning down will be measured and paid.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
M & L Returning and filling in of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified.
Taking out Old UG cables of any sizes from trenches/walls including all mounting accessories and GI tubing and keeping aside in safe custody for relaying after repairs including making good to disturbed areas.
Relaying of UG cable, nominal crosss section area of 10 to 50 sqmm 2/4 core after testing, carrying out of joining works including removal of Unsv portions complete all as specified. and as directed. Note:- Necessary Joints will be measured and paid seperately under relevant item of BOQ
Relaying of UG cable nominal cross section area of 70 to 150 sqmm 3.5 core after testing, carrying out of joining works incl removal of UNSV portions complete all as specified. and as directed. Note:- Necessary Joints will be measured and paid seperately under relevant item of BOQ
M&L for LT Cable joining kit straight through cold shrinkable type complete with joining materials suitable for LT armoured cable of size upto 10/16 Sqmm 2 core all as directed
All as per Srl item No. 9 here in above but for cable sizes 25 sqmm to 50 sqmm 4 core.
All as per Srl item No. 9 here in above for cable sizes 70 to 150 sqmm 3.5 core
Taking down old unserviceable LT panel board/ feeder pillars of any size including mounted switch gear/Energy meters etc. complete
Supply, install, testing and commissioning of factory made, Indoor LT panel board cubicle type, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated aluminium bus bar of rating 400 Amps for phases and 200 Amps for neutral fixed on porcelain/epoxy insulators. The panel shall be dust and varmin proof and fabricated out of 2.0 mm CRCA sheet duly powder coated after seven tank process and mounted on MS angle iron frame work.The panel shall have adequate space n.less than 1.50 x 1.00 x 0.20 m for mounting acessories such as LT switchgear and measuring instruments etc including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties :-
(a) MCCB 415 Volts,200 Amp , rating 4 Pole, Microprocessor based release (Service Breaking Capacity 25 KA =1 No (Incoming). .(b) Outgoing MCCB 415 Volts,160 Amps, rating 3 Pole, Microprocessor based release (Service Breaking Capacity 18 KA) - 03 Nos. (c) Digital Ampere meter 0-300 Amps with and including CTs-01 No (d) Digital volt meter 0-500 Volts-01 No (e) Internal wiring of panel with stranded copper cable of suitable size (f) Neon/LED phase indicating lamp(Set of three)-01 Set
Supply, install, testing and commissioning of factory made, Indoor LT panel board cubicle type, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated aluminium bus bar of rating 1000 Amps for phases and 800 Amps for neutral fixed on porcelain/epoxy insulators. The panel shall be dust and varmin proof and fabricated out of 2.0 mm CRCA sheet duly powder coated after seven tank process and mounted on MS angle iron frame work.The panel shall have adequate size not less than 1.80 x 0.95 x 0.30 m for mounting acessories such as LT switch gear and measuring instruments etc including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard in practice , comprising of followings acessorties :-
(a) MCCB 415 Volts,630 Amp , rating 4 Pole, Microprocessor based release (Service Breaking Capacity 25 KA =1 No (Incoming). .(b) Outgoing MCCB 415 Volts,250 Amps, rating 4 Pole, Microprocessor based release (Service Breaking Capacity 25 KA) - 03 Nos. (c) Digital Ampere meter 0-500 Amps with and including CTs-01 No (d) Digital volt meter 0-500 Volts-01 No (e) Internal wiring of panel with stranded copper cable of suitable size (f) Neon/LED phase indicating lamp(Set of three)-01 Set
Supply, install, testing and commissioning of factory made, Outdoor LT panel board cubicle type, compartmentalised design with front and rear openable doors suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated aluminium bus bar of rating 600 Amps for phases and 400 Amps for neutral fixed on porcelain/epoxy insulators. The panel shall be dust and varmin proof and fabricated out of 3.15 mm CRCA sheet duly powder coated after seven tank process and mounted on MS angle iron frame work.The panel shall have adequate size n.less than 1.3 x 1.1 x 0.6 m for mounting acessories such as LT switchgear and measuring instruments etc including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties :-
(a) MCCB 415 Volts,250 Amp , rating 4 Pole, Microprocessor based release (Service Breaking Capacity 25 KA =1 No (Incoming). .(b) Outgoing MCCB 415 Volts,200 Amps, rating 4 Pole, Microprocessor based release (Service Breaking Capacity 25 KA) - 02 Nos. .(c) Outgoing MCCB 415 Volts,160 Amps, rating 4 Pole, Microprocessor based release (Service Breaking Capacity 25 KA) - 01 No. (d) Digital Ampere meter 0-500 Amps with and including CTs-01 No (e) Digital volt meter 0-500 Volts-01 No (f) Internal wiring of panel with stranded copper cable of suitable size (g) Neon/LED phase indicating lamp(Set of three)-01 Set
M&L in repairs PVC insulated multi stranded copper flexible wire 16 sqmm, sigle core for inter connections in LT panel boards
M& L in repairs PVC insulated multi stranded copper flexible wire 25 sqmm, sigle core for inter connections in LT panel boards
M& L for overhauling of LT Panel boards outdoor/indoor of sizes upto 200 x 150 x 50 cms installed at various locations of SMA/DAD/NPOL, by disconnecting from mains, taking out burnt cable ends and reconnecting using necessary lugs, cable glands, gland plate, gaskets etc and application of necessary mechanical and electrical lubrication when and where as directed by Engr-in-Charge.
M& L for overhauling of LT Feeder pillars outdoor/indoor of sizes upto 100 x 100 x 40 cms installed at various locations of SMA/DAD/NPOL, by disconnecting from mains taking out burnt cable ends and reconnecting using necessary lugs, cable glands, gland plate, gaskets etc and application of necessary mechanical and electrical lubrication when and where as directed by Engr-in-Charge.
M&L for fixing in repairs Aluminium Bus bar of desired sizes, bend to shape as reqd at site including all necessary drilling works,repairing of burnt cable ends using new lugs , all as directed
M&L for fabrication of sheet metal components of panel boards using 2.00 mm thick CRCA powder coated sheets when and where as required as in doors, partitions etc including fixing to exisitng panels using all necessary hinges, panel locks, weather proof gaskets etc as reqd at site complete incl taking down of old one, all as directed .
M& L for painting to old steel surface of LT Panel boards, outdoor/indoor of sizes upto 200 x 150 x 50 cms installed at various locations of SMA/DAD/NPOL, by scrapping out of rusted uneven surfaces and applying by spray painting two coats of synthetic enamel paint over a coat of primer, all as specified and as directed .
M& L for painting to old steel surface of LT Panel boards outdoor/indoor of sizes upto 100 x 100 x 40 cms installed at various locations of SMA/DAD/NPOL, by scrapping out of rusted uneven surfaces and applying by spray painting two coats of synthetic enamel paint over a coat of primer , all as specified and as directed .
M&L preparation of old treated surfaces of walls and applying one coat of cement based paint of approved make and colour complete all as specified.
Supplying and laying 80 mm bore GI tubing light grade for encasing cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles with complete accessories such as bends/sockets/reducers/saddles including taking down of old GI tubing all as specified and directed
All as per Srl item No.25 here in above but 50 mm bore
All as per Srl item No.25 here in above but 40 mm bore
All as per Srl item No.25 here in above but 32 mm bore
S & F in replacement MCCB 63 Amps , 415V,TPN, 16 kA,4pole thermal magnetic release with spreader terminals and incl making necessary connections, fixing existing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and directed .
S & F in replacement MCCB 100 Amps ,415V ,TPN 16 kA,4pole thermal magnetic release with spreader terminals and incl making necessary connections, fixing to existing panel Boards and ensure compatibility with existing MCCB in fit and finish complete, all as specified and directed .
S & F in replacement MCCB 125 Amps,415V TPN 16 kA, 4pole, thermal magnetic release with spreader terminals and incl making necessary connections, fixing to existing panel Boards and ensure compatibility with existing MCCB in fit and finish complete, all as specified and directed.
S & F in replacement MCCB 160 Amps,415V TPN 25 kA, 4pole, thermal magnetic release with spreader terminals and incl making necessary connections, fixing to existing panel Boards and ensure compatibility with existing MCCB in fit and finish complete, all as specified and directed.
S & F in replacement MCCB 200 Amps,415V TPN 25 kA, 4pole, thermal magnetic release with spreader terminals and incl making necessary connections, fixing to existing panel Boards and ensure compatibility with existing MCCB in fit and finish complete, all as specified and directed.
S & F in replacement MCCB 250 Amps,415V TPN 25 kA, 4pole, thermal magnetic release with spreader terminals and incl making necessary connections, fixing to existing panel Boards and ensure compatibility with existing MCCB in fit and finish complete, all as specified and directed.
S & F in replacement MCCB 400 Amps,415V TPN 25 kA, 4pole, thermal magnetic release with spreader terminals and incl making necessary connections, fixing to existing panel Boards and ensure compatibility with existing MCCB in fit and finish complete, all as specified and directed.
S & F in replacement MCCB 630 Amps,415V TPN,50 kA, 4pole, thermal magnetic release with spreader terminals and incl making necessary connections, fixing to existing panel Boards and ensure compatibility with existing MCCB in fit and finish complete, all as specified and as directed.
M&L Mounting enclosure for MCCB of size not less than 60x25x15 cms fabricated out of powder coated CRCA sheet 1.6 mm thick including supply and fixing one microprocessor based four pole MCCB of capacity 160 Amps,25 kA incl all necessary mounting accessories like lugs, Glands etc complete , all as specified and as directed.
Supply and fix in repairs Air termination single pointed aluminium rod 12 mm dia and 300 mm long fixed on the roof including all fittings, fixed on PCC blocks(1:2:4, type B-1 using 20mm graded stone aggregate ) size100 mm x 100 mm x 100 mm complete, all as specified and as directed.
Supply and fix in repairs Air termination single pointed copper rod 12 mm dia and 300 mm long fixed on the roof including all fittings,fixed on PCC blocks(1:2:4, type B-1 using 20mm graded stone aggregate ) size100 mm x 100 mm x 100 mm complete, all as specified and as directed.
Supply and fix in repairs Earth Test point terminal block made of gun metal or phosphorus bronze size 75X75X25 mm of 6 mm thickness drilled and secured including 4 Nos 8mm dia, 25mm long hexagonal head brass screws , secured to wall complete , all as specified and as directed.
M&L taking down Aluminium strip of size up to 25 x 3.15 mm,and refixing the same with new saddles , screws etc. for roof conductors and down conductors connected with existig system using rust proof nuts and bolts all as directed.
Supply and fix aluminium strip 25 X 3.15 mm fixing with saddles/insulators ,screws etc in roof and down conductors connected with rust proof nuts and bolts including taking down of old strip all as specified and as directed.
Supply and fix copper strip 25 X 3.15 mm fixing with saddles/insulators ,screws etc in roof and down conductors connected with rust proof nuts and bolts including taking down of old strip all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in foundation for GI pipe post in parapet wall for lightening protection complete allas specified and directed at site.
M&L in repairs HDPE Corrugated flexible pipe ,double wall heavy duty of internal dia 80 mm on walls or laying in trenches including all accessories,all as specified and as directed. Make:- Apollo, Jain, gamson,.
M&L in repairs HDPE Corrugated flexible pipe ,double wall heavy duty of internal dia 50 mm on walls or laying in trenches including all accessories,all as specified and as directed. Make:- Apollo, Jain, gamson,.
M&L in replacement Industrial batteries of capacity 02 Volts 200 Ah deep cycle tubular battery, electrolyte filled in transparent containers of size 210 x 203 x 426 cms including initial charging, all as specified and as directed. Make:- Exide Cat part No- Plante YKP17 or equivalent from Amaron, Osakaya.
Demolition of concrete of any description and in any position not otherwise provided for, all as specified and as directed.
M & L Providing cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping and including weathering, slightly rounded or chamfered angles and throating and including necessary form work with fair finished concrete surfaces, all as specified and as directed.
M&L for pre-cast cement concrete 1:3:6, type C1 using 20mm graded stone aggregate as in block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed. including demolition of existing damaged masonary work, all as specified and as directed.
M&L 15mm thick rendering on brick/concrete surfaces in CM 1:6 finished even and smooth w/o using extra cement, all as specified and as directed.
M&L for clearing /cutting of Grass, Shrubs and other growings by uprooting around poles and feeder pillars in various locations as directed
S & F in repairs Mild steel work in framed work such as Clamps, gratings, ladders etc., with ends of bars welded and/ or riveted, or forged and similar work confirming to Fe 410 - O or Fe 310 - O a as directed.
M& L preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer , all as specified and as directed.
M& L in replacement GI Strip 32x6 mm fixing with saddle,screws etc , all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI strip 32x6mm mm by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
AR Traders
WELTRONENGINEERINGSERVICES
AB CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .