| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | ₹39.4 L Quoted ₹40.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹44.1 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹44.1 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹46.2 LRejected-Finance | ₹46.2 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹68.3 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹68.3 L | L4 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/s.Bhavin Electricals L3 | JAMNAGAR ELECTRIC AND MACHINERY CO L4 | M/s Balaji Enterprise L1 | BHAVNA IMPERIAL ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. | 451 | Cubic Metre | 300 ₹1.4 L | 340 ₹1.5 L | 260 ₹1.2 L | 200 ₹90,200 |
| 2.00 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed. | 341 | Cubic Metre | 48 ₹16,368 | 125 ₹42,625 | 90 ₹30,690 | 60 ₹20,460 |
| 3.00 | Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. | 110 | Cubic Metre | 70 ₹7,700 | 150 ₹16,500 | 80 ₹8,800 | 60 ₹6,600 |
| 4.00 | M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed. | 60 | Running Metre | 390 ₹23,400 | 550 ₹33,000 | 250 ₹15,000 | 170 ₹10,200 |
| 5.00 | M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed.
Notes :-
(i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used.
(ii) For the purpose of payment, only punned thickness shall be measured. | 74 | Cubic Metre | 850 ₹62,900 | 1,000 ₹74,000 | 700 ₹51,800 | 700 ₹51,800 |
| 6.00 | Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed. | 6,060 | Each | 1 ₹6,060 | 3 ₹18,180 | 0.5 ₹3,030 | 1 ₹6,060 |
| 7.00 | Laying only LT PCC cable covers of any type & size for protection of UG LT electric cables in trenches, obtained serviceable from serial item No. 6 here-in-above, complete all as specified & as directed. | 250 | Each | 3 ₹750 | 5 ₹1,250 | 0.5 ₹125 | 1 ₹250 |
| 8.00 | Supply and laying un-reinforced precast concrete cable cover, Class LV, Type-1, Flat, size 250mm x 150mm x 40mm for protection of underground electric cable in trenches complete all as specified and as directed. | 5,810 | Each | 17 ₹98,770 | 22 ₹1.3 L | 15 ₹87,150 | 17 ₹98,770 |
| 9.00 | Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed. | 775 | Running Metre | 96 ₹74,400 | 100 ₹77,500 | 62 ₹48,050 | 111 ₹86,025 |
| 10.00 | M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.
Note :- Excavation & earthwork shall be measured & paid for separately. | 20 | Running Metre | 900 ₹18,000 | 550 ₹11,000 | 300 ₹6,000 | 800 ₹16,000 |
Updated dates
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
23 May 2026, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
Repair/ replacement and maintenance of External Electrical Supply System and Distribution Panels/ Feeder Pillar and connected Items at INS Valsura, Jamnagar
2026_MES_762414_1
8957/VAL/E8
Open Tender
Electrical and Maintenance Works
335 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹76,000
Yes
27 May 2026
27 Apr 2026
25 May 2026
27 Apr 2026
23 May 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. | 451 | Cubic Metre | - | - |
| 2 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed. | 341 | Cubic Metre | - | - |
| 3 | Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. | 110 | Cubic Metre | - | - |
| 4 | M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed. | 60 | Running Metre | - | - |
| 5 | M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed.
Notes :-
(i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used.
(ii) For the purpose of payment, only punned thickness shall be measured. | 74 | Cubic Metre | - | - |
| 6 | Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed. | 6,060 | Each | - | - |
| 7 | Laying only LT PCC cable covers of any type & size for protection of UG LT electric cables in trenches, obtained serviceable from serial item No. 6 here-in-above, complete all as specified & as directed. | 250 | Each | - | - |
| 8 | Supply and laying un-reinforced precast concrete cable cover, Class LV, Type-1, Flat, size 250mm x 150mm x 40mm for protection of underground electric cable in trenches complete all as specified and as directed. | 5,810 | Each | - | - |
| 9 | Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed. | 775 | Running Metre | - | - |
| 10 | M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.
Note :- Excavation & earthwork shall be measured & paid for separately. | 20 | Running Metre | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8957TENDER.pdf
Tender Documents • 1.06 MB
BOQ_854007.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid