Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹34.4 L+₹1.7 L (5.21%)Rejected-Finance RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹38.3 L+₹5.6 L (17.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹38.7 L+₹6.0 L (18.2%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹38.7 L+₹6.0 L (18.3%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
21 May 2022, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_519577_1
GE MAINT EZHIMALA 8470
Open Tender
Civil Works
Item Rate
180 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹88,000
Yes
31 May 2022
23 Apr 2022
23 May 2022
23 Apr 2022
21 May 2022
9 May 2022
25 Apr 2022 - 2 May 2022
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets upto a height of 12 m complete all as specified and as directed. Note:- The quoted rate is deemed to be inclusive of necessary scaffolding needed for the work and no claim whatsoever is entertained on this account.
M&L for Gl frame work suitable for multilevevel seamless ceiling of approved shape and design (dome, stepped, curved etc) comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and providing necessary hangers/ suspenders for the frame work complete all as specified and as directed by Engg in Charge. Note:- The work need to be done at a height upto 12 m. The quoted rate is deemed to be inclusive of necessary scaffolding needed for the work and no claim whatsoever is entertained on this account.
M&L for 12 mm thick seamless gypsum board of size not less than 1800x1200mm for multi level ceiling of approved design and shape (dome, stepped, curved etc ) and at any height made out of gypsum board material fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and applying 1 mm putty and over that applying two coat of texture painting of approved pattern over a coat of primer complete all as specified and as directed by Engg in Charge. Notes:- 1. The plan area will be measured for payment. 2. The quoted rate is deemed to be inclusive of necessary scaffolding needed for the work and no claim whatsoever is entertained on this account. 3. Contractor need to submit coloured 3D image of false ceiling design (including painting pattern) and get approval from Engg in Charge prior to commencement of work.No extra charge will be payable to contractor in this regard.
Dismantling floor hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and rubbish of the premises complete all as specified and as directed.
M&L for vitrified coloured ceramic tiles 10mm thick (square/ rectangular), light shade polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 20mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for vitrified ceramic tiles 10mm thick (square/rectangular), light shade polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the light shade including 15mm thick backing coat plaster in CM 1:4 complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting in hard/dense soil complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and as directed.
M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for sand filling for cushion bed below interlocking paver blocks complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and as directed.
M&L for colour code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC casing caping with suitable size GI flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting 6 Amps switch with socket on independent board including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and as directed at the site. Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for sub main wiring using 2 runs of 4 Sqmm FRLS PVC insulated copper conductor 1100 volts grade confirming to IS specification drawn through and including PVC casing and caping along with 1 run of 4 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly completed all as specified and directed by Engr in charge. Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) One run of casing caping, 3 run of 4 sqmm PVC insulated copper conductor cable will be measured as one unit length. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for sub main wiring using 4 runs of 10 Sqmm FRLS PVC insulated copper conductor 1100 volts grade confirming to IS specification drawn through and including suitable size of PVC conduit along with 2 run of 10 Sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly completed all as specified and directed by Engr in charge. Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) One run of PVC Conduit, 6 run of 10 sqmm PVC insulated copper conductor cable will be measured as one unit length. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
S&F Modular switch one way 20A, 1 module with suitable modular plates and boxes complete all as specified and directed by Engr in charge.
S&F Modular AC socket with MCB single pole 25/32 Amps C-series, AC 240Volts complete all as specified and directed by Engr in charge.
S&F MCB TPN 63 Amps C curve complete all as specified and as directed by Engr in charge.
S&F recess mounted 36W luminaire 2x2 Tile, out put lumen greater than 100 lumen/watts glare free uniform illumination housing with opel diffuser with colour temp 600K s complete all as specified and directed by Engr in charge. Make:- Crompton Model Polaris NIO I LCTLRNE-36-FO-CDL or equivalent in Wipro/Philips/Havells.
SANDR
Abraham Builders
KDR CONSTRUCTION
Gates Infra Construction Co
GMS Builders
RS ENTERPRISES
Palace constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .