Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹73,504
EMD Value
₹2,500
Closing Date
24 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER, KSCADC
KSCADC Building, Kamalewsaram , Manacaud P.O. Thiruvananthapuram Pin-695009
Ezhukone Gramapanchayath Annual Plan 2025-26 Ezhukone Panchayath Mahatma Gandhi Auditorium cum Panchayath Office Renovation Additional Electrical Works for the modification of incoming supply.(Project No.134/2024-25)
2026_SCADC_828352_1
ET-90/2025-26
Open Tender
Electrical Works
Item Rate
30 days
Ezhukone In Kollam -District
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
₹2,500
27 Jan 2026
16 Jan 2026
27 Jan 2026
16 Jan 2026
24 Jan 2026
16 Jan 2026
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
OD256585/2025-2026:Supply and fixing of TP, 63A, 415V, 'C', curve 10kA, MCB in the existing DB/enclosure, as required. (Approved make by CPWD/KPWD/KSCADC)
OD256586/2025-2026: Supply, installation and commission of TP, 40A, 415V MCB, 'C', curve, 10kA inside DB (Make: Legrand DX3, ABB or any equivalent make approved by KPWD/CPWD/KSADC)
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
cabling
90.12.6.28:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm
90.12.6.40:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
90.12.6.42:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 25 sq mm
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD256589/2025-2026:Supply and fixing of FP, 40A, 415V, 'C', curve 10kA, MCB in the existing DB/enclosure, as required. (Approved make by CPWD/KPWD/KSCADC)
OD256590/2025-2026:Supply and fixing of Four pole, 16SWG, powder coated metallic enclosure, single door on surface/recess without MCB/Isolator/RCCB
OD256591/2025-2026:Supply and fixing of copper grounding clips (shim) 60 mm long x 20 mm wide x 1.20 mm thick for single compression glands for cable size 25sqmm to 95sqmm
OD256592/2025-2026:Supply and fixing of copper grounding clips (shim) 60 mm long x 12 mm wide x 1 mm thick for single compression glands for 4sqmm to 16sqmm cables.
Energy Meter Box
OD256593/2025-2026:Supply and installation of HRC Fuse Base with HRC Fuse link of the following rating on the existing panel board/Enclosure, as required. 80A
OD256594/2025-2026:Supply and installation of following rated 2 Way neutral links mounted on DMC/SMC base on panel board/enclosure, as required. 80A
2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
OD256595/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100A
Additional
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
OD256596/2025-2026:Supply, fixing and merging of High-Quality Polyolefin Material Heat Shrink Tube for Wire Insulation, Cable Sleeves Wrap, Multi Colors and Sizes. Charging Cable Repair Sleeves having Continuous Operating Temperature: -45℃to125℃ and Shrinkage Ratio: 2:1. size 7mm, 8mm and 10mm of 1M length. (Red/White/Blue/Green/Black)
OD256597/2025-2026:Labour charges for removing/dismantling the existing conduit, wire, cable, LAN cable, Electrical inventories etc… and placing them on an appropriate place for further actions.
finance_1390546.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
TD7900126.pdf
Tender Documents • 3.59 MB
BOQ_1390546.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .