Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.5 CrAccepted-AOC 203 GURU CHAMBERS 2501 8 BEADONPURA KAROL BAGH DELHI DELHI 110005 | CENTRAL DELHI | DELHI | 110005 | ₹1.5 Cr | L-1 | Accepted-AOC L1 |
| 2 | L-2₹2.2 Cr+₹69.7 L (45.4%)Rejected-Finance 201 202 LALA 1 LANDMARK MG ROAD HYDERABAD HYDERABAD | ₹2.2 Cr+₹69.7 L (45.4%) | L-2 | Rejected-Finance L-2 |
| 3 | Rejected-Technical 104 FIRST FLOOR LSC NATIONAL ARCADE GHAZIPUR MAIN ROAD GHAZIPUR MAIN ROAD GHAZIPUR EAST DELHI DELHI 110096 | EAST DELHI | DELHI | 110096 | - | - | Rejected-Technical Firm did not meet NIT criteria |
| 4 | Rejected-Technical C 2 MADEL INDUSTRIAL ESTATE NEAR VIRWANI INDUSTRIAL ESTATE ROAD NO 2 GOREGAON E MUMBAI 400063 | MUMBAI | MUMBAI | MAHARASHTRA | 400063 | - | - | Rejected-Technical Firm did not meet NIT criteria |
| 5 | Rejected-Technical | - | - | Rejected-Technical Firm did not meet NIT criteria |
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
8 Jul 2019, 6:00 pmClosed
AGME(E)-I
AAI, OPS BLDG, 1ST FLR, EMD-II, NSCBI AIRPORT, KOLKATA-52.
Provision of Tyre Killers and Hydraulic Bollards at Various locations at NSCBI Airport, Kolkata.
2019_AAI_27482_1
AAI/EMD-II/SEC/2019
Open Tender
Electrical Works
Item Rate
120 days
NSCBI AIRPORT, KOLKATA
Please refer to the e-NIT.
14 documents required · 14 mandatory
₹1,120
AAI
₹6.4 L
10 Jan 2020
25 Jun 2019
11 Jul 2019
25 Jun 2019
8 Jul 2019
25 Jun 2019
25 Jun 2019 - 2 Jul 2019
Amount
SH:- I (CAPITAL Portion)
DSITC of TRL/MIRA or any other equivalent independent international agency crash test certified high security hydraulically operated bollards with crash rating suitable for 7.5 TN vehicle with speed of 80Km/Hr. (As per PAS 68/ASTM F2656-15/ IWA 14-1:2013 standards), Blocking Height: 1000 mm, Diameter: 275mm, The Bollard assembly shall be supplied Complete with following accessories: 1. Drainage pump. 2. PLC based control panel (suitable for outdoor application). 3. Excavation of existing road, making suitable civil foundation as per approved drawing duly vetted by IITs/ State Engineering College or AAI empaneled authorized consultant i/c excavation of existing road and making good the same after installation of Bollards complete as required i/c crossing the RCC drain (if applicable) by making suitable openings and sealing the gaps thereafter comprising of items and features as per enclosed technical specifications. 4. Laying of GI pipes for incoming & outgoing power & control cables. 5. Hydraulic system, Logic circuit. 6. Accumulator system for hydraulic operation in case of power failure. 7. Any other accessories as required for making the complete system fully functional as required or as directed by the Engineer-In-Charge.
Set of 6
4 Mtr blocking Width
6 Mtr blocking Width
Supply of following size PVC /XLPE insulated PVC Sheathed armored Al cable of 1.1 KV grade conforming to IS:7098(Part-I) as amended upto date.
4 Core X 35 Sq.MM
4 Core X 50 Sq.MM
Laying of LT cables
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required & as directed by the E-I-C. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing masonry open duct as required & as directed by the E-I-C. Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required & as directed by the E-I-C. Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required.
4 X 35 sq. mm (32mm)
4 X 50 sq. mm (35mm)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
63 A, 35 KA, FP MCCB
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer i/c excavation and re-filling etc. as required
SH:- II (R & M Portion)
All Inclusive Comprehensive Maintenance Contract after completion of Two years Defect Liability Period for the above bollards (As per item no-01 under SH-1) i/c periodical, preventive, break down maintenance as per the OEM recommendations & AAI requirements and attending emergency breakdowns as and when required on 24 hrs basis (on all days including holidays) and including all necessary spares and consumables to keep the whole bollard system in perfect working condition etc. complete as required and as per the particular specifications specified i/c provision of 1 no skilled and 1 no semi-skilled man power as mentioned in particular specification of this work. (The manpower shall be taken for the whole AICMC portion and the same to be provided during the DLP also)
Set of 6
For 1st Year(after Two years DLP)
For 2nd Year(after Two years DLP)
For 3rd Year(after Two years DLP)
For 4th Year(after Two years DLP)
For 5th Year(after Two years DLP)
All Inclusive Comprehensive Maintenance Contract after completion of Two years Defect Liability Period for the above Tyre Killers(As per item no-02 under SH-1) i/c periodical, preventive, break down maintenance as per the OEM recommendations & AAI requirements and attending emergency breakdowns as and when required on 24 hrs basis (on all days including holidays) and including all necessary spares and consumables to keep the whole tyre killer system in perfect working condition etc. complete as required and as per the perticular specifications specified.
4 Mtr blocking Width
For 1st Year(after Two years DLP)
For 2nd Year(after Two years DLP)
For 3rd Year(after Two years DLP)
For 4th Year(after Two years DLP)
For 5th Year(after Two years DLP)
6 Mtr blocking Width
For 1st Year(after Two years DLP)
For 2nd Year(after Two years DLP)
For 3rd Year(after Two years DLP)
For 4th Year(after Two years DLP)
For 5th Year(after Two years DLP)
GODREJ AND BOYCE MFG CO LTD
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .