Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-AOC GOUSALA ROAD VIKASH NAGAR DIST RAMGARH JHARKHAND 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Since accepted L1 | |
| 2 | L2₹3.0 L+₹11,175.95 (3.87%)Rejected-Finance ARGADA RAMGARH JHARKHAND 829101 | RAMGARH | JHARKHAND | 829101 | L2 | Rejected-Finance Rejected since L2 | |
| 3 | L3₹3.0 L+₹13,403.45 (4.64%)Rejected-Finance KUJU DIST RAMGARH | KUJU | RAMGARH | L3 | Rejected-Finance Rejected since L3 |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
29 Dec 2023, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO(EnM)
GM UNIT KUJU
Dismantle, commissioning and shifting of 01 no. lighting tower at Karma OCP under Kuju Area
2023_CCL_296521_1
GM (K)/EnM/eTender/23-24/143
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
GM UNIT KUJU
2 documents required · 2 mandatory
₹4,000
1 Mar 2024
19 Dec 2023
30 Dec 2023
19 Dec 2023
29 Dec 2023
19 Dec 2023
19 Dec 2023 - 26 Dec 2023
Amount
Eredion of metallic pole of following length in cement concrete 1:3:6 (1 cement 3 coarse sand: 6 graded stone aperegate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener), 7/3.15mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excovation and refilling and also with 0.6 m long brace of size 50 mm x 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metrc) cross arm for 4 wire over head line complete with clamps, bcIts, nuts and washer etc including crilling of holes for insulator pins etc (as pcer drawing) and painting with primcr and finished paint as required
Supplying and erection of 100 mm X 110 mm shackle insulator with G. i. Bolt, nuts and straps etc. as required
Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nErection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and laying G.I tape 32 mm X 6 mm from earth electrode directly in ground as required
Providing and laying in position cement concrete 1:3 6 (1 cement: 2 coarse sand: 6 praded stone aggregate 40 mm nominal sirel in foundation of pump, DG set etc including form work etc as required
Supplying. installing. testing and commissioning of following capacity TPN tap off box made of 1 6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required 100 AMP
Erection and commissioning of Lighting Tower with alignment charges by providing only men power
Dismantling of Lighting Tower with transporting charges to work site by providing only men power
Earth work in excavation by mechanical means (Hydralic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sam on plan ), including dressing of sides and rammine of bottoms, lift upto 1.5 m, including getring out the excavated soil and disposal of surplus excovated soil as directed, within a lcad of 50 m.
Supply & Fixing of Tower Bolt Foundation Bolt 25mm X 400mm
Supply & Fixing of Nut & Bolts
Total impact of GST for the purpose of CTC
M/S VAISHALI ELECTRIC COMPANY
NEW NATIONAL ELECTRICAL WORKS
techsummary_307122.pdf
PDF • 1.38 MB
finsummary_307122.pdf
PDF • 1.38 MB
LOA143.pdf
PDF • 1.31 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .