Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC | ₹1.7 L | L1 | Accepted-AOC Lowest Bidder |
Tender Value
₹1.7 L
EMD Value
₹4,200
Closing Date
21 May 2026, 4:00 pmClosed
ASST. EXECUTIVE ENGINEER, ELECTRICAL SUBDIVISION,
OFFICE OF THE ASSISTANT EXECUTIVE ENGINEER, ELECTRICAL SUBDIVISION, TDB,SOUTH NADA-SREEKRISHNASWAMY TEMPLE,MAVELIKKARA-690101
DB UPS Angadikkal Electrical Repair and Maintenance at DB UPS Angadikkal in Preparation for School Reopening.
2026_TDB_850476_2
AEE/EL/ET-78/2026-27
Open Tender
Electrical Works
10 days
OFFICE OF THE ASST. EXECUTIVE ENGINEER
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
₹4,200
29 May 2026
18 May 2026
21 May 2026
18 May 2026
21 May 2026
18 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Electrical Works | ||||||
| 1.001 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,273.18 | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | - | each | 2,244.96 | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | - | each | 4,665.37 | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 90.2.1.14:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent Plug - Medium Point | - | each | 809.25 | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size | - | metre | 313.66 | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 90.12.1.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm | - | metre | 415.67 | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | - | each | 424.29 | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | - | each | 377.01 | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module | - | each | 174.16 | - | BI01010001010000000000000515BI0100001122 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1438986.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
priliminaryagreement.pdf
Tender Documents • 0.33 MB
specialcondition.pdf
Tender Documents • 0.24 MB
approvedmaterials.pdf
Tender Documents • 0.51 MB
BOQ_1438986.xls
BOQ • 0.33 MB
tendernotice26.pdf
Tender Documents • 0.31 MB
Download all tender documents and submit your bid