| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹11.9 L+₹94,555 (8.65%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹13.8 L+₹2.8 L (26.0%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹13.9 L+₹3.0 L (27.6%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹14.3 L+₹3.4 L (30.9%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
3 May 2021, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_434979_1
GE MAINT EZHIMALA 8370
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹30,000
Yes
14 Jun 2021
7 Apr 2021
5 May 2021
7 Apr 2021
3 May 2021
21 Apr 2021
8 Apr 2021 - 15 Apr 2021
Amount
S&F in replacement wall mounted 20 W LED 4ft batten output lumen > 100 lumen/watt ,CRI > 60,CCT >5500k ,internal surge protection up to 2 Kv , power factor > 0.93 having extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver with all accessories pre-wired and including connecting up 3 core flexible copper conductor cable suitable size from fitting to ceiling rose/connection terminals complete all as specified and directed by Engineer in charge. Make:- Crompton model TRIMLINE Cat part No. LDL-20-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement wall mounted 10 W LED 2ft batten output lumen > 100 lumen/watt ,CRI > 80 ,CCT >5500 k , internal surge protection up to 2 Kv , power factor > 0.93 having extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver with all accessories pre-wired and including connecting up 3 core flexible copper conductor cablesuitable size from fitting to ceiling rose/connection terminals complete all as specified and directed by Engineer in charge. Make:- Crompton model TRIMLINE Cat part No. LDL-10-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire out put lumen >100 lumen/w, CCT > 5500 k, power factor > 0.95 comprising of high brightness LEDs 10 W with opal diffuser with all accessories pre-wired and including connecting up with 3core flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals complete all as specified and directed by Engineer in charge. Make:- Jaquar Cat part No.LBL K01x010xW or equivalent in Havells/Wipro/Crompton
S&F in replacement Recess full lit luminaire with glare free uniform illumination with longer life and less maintenance 36 W (2 ' x 2 ') in MS housing with opal diffuser with colour temp 6000K, Luminous efficacy-> 100/watt,CCT> 5500 k,CRI- 80,Power factor >0. 95,THD < 10 with all accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/ connection terminals including aluminium frame for fitting the same complete all as specified and directed by Engineer in charge. Make:- Crompton model POLARIS N10-1 Cat part No. LCTLRNE-36-FO-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement surface full lit luminaire with glare free uniform illumination with longer life and less maintenance 36 W (2 ' x 2 ') in MS housing with opal diffuser with colour temp 6000K, Luminous efficacy-> 100/watt,CCT> 5500 k,CRI- 80,Power factor >0. 95,THD < 10 with all accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/ connection terminals including aluminium frame for fitting the same complete all as specified and directed by Engineer in charge. Make:- Crompton model POLARIS N10-111 Cat part No. LCTLSNE-36-FO-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement LED Downlighter 30W with colour temp 6000K , Luminous efficacy-> 100/watt,CCT> 5500 k,CRI- 80,Power factor >0. 95 deep recessed antiglare led downlight for general and accent lighting with premium white reflector matches the ceiling and accentuates the architecture of the area without compromising the light output including driver and all connected accessories with all accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals and adjusting rings for fixing etc complete all as specified and directed by Engineer in charge. Make:- Crompton Cat part No. LCDN-30-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement High efficacy 1x1 LED 18 watt surface full lit luminaire with glare free unifrom illumination with longer life and less maintenance and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals Luminous efficacy > 100/w, CCT .5500 k,CRI > 80,PF 0.95 complete all as specified and directed by Engineer in charge. Make:- Crompton model POLARIS N10-111 Cat part No. LCTLSNE-18-FO-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement High efficacy 1x1 LED 18 watt Recessed full lit luminaire with glare free unifrom illumination with longer life and less maintenance and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals ,Luminous efficacy > 100/w, CCT .5500 k,CRI > 80,PF 0.95 complete all as specified and directed by Engineer in charge. Make:- Crompton model POLARIS N101 Cat part No. LCTLRNE-18-CDL (1x1) or equivalent in Havells/Wipro/Jaquar
S&F in replacement suspended luminairies 36W LED 4 feet with colour temperature 6000K having extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including 02 Nos suspension kit, CRI -80,THD- < 10 %,Lumens >100,Powerfactor-.0.92,Internal surge voltage- 2kv, complete with all accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals complete all as specified and directed by Engineer-in-Charge. Make:- Crompton model TREND-1 Cat part No. LCLP54-36-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement 6W LED spot light ideal for wardrobes , furniture lighting,displays& interior decorations Luminous efficacy -> 100/watt ,CCT> 5500 k,CRI- 80,Power factor >0. 90 including connecting up 3 core copper conductor cable of suitable size from fitting to ceiling rose/connection terminals complete all as specified and directed by Engineer in charge. Make:- Crompton Cat part No. LCSRR-6-CDL or equivalent in Havells/Wipro/Jaquar
S&F in replacement LED surface downlighter 12W in round profile.Luminous efficacy-> 100/watt,CCT> 5500 k,CRI- 80,Power factor >0. 90 including connecting up 3 core 1 sqmm copper conductor cable from fitting to ceiling rose/connection terminals complete all as specified and directed by Engineer in charge. Make:- Crompton model PEARL NIOS - R Cat part No. LCDSPNL-R-12-CDL or equivalent in Havells/Wipro/Jaquar
M&L for submain wiring using 2 runs of 10 sqmm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC Conduit/casing caping along with 1 run of 10 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down of unserviceable wiring complete all as specified and directed by Engr-in-charge. Notes:- (i) One run of PVC conduit/ casing caping, 3 runs of 10 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
M&L for submain wiring using 2 runs of 6 sqmm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC Conduit/casing caping along with 1 run of 6 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down of unserviceable wiring complete all as specified and directed by Engr-in-charge. Notes:- (i) One run of PVC conduit/ casing caping, 3 runs of 6 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
M&L for submain wiring using 2 runs of 2.5 sqmm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC Conduit/casing caping along with 1 run of 2.5 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down of unserviceable wiring complete all as specified and directed by Engr-in-charge. Notes:- (i) One run of PVC conduit/ casing caping, 3 runs of 2.5 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
M&L for submain wiring using 2 runs of 4 sqmm FRLS, IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC Conduit/casing caping along with 1 run of 4 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down of unserviceable wiring complete all as specified and directed by Engr-in-charge. Notes:- (i) One run of PVC conduit/ casing caping, 3 runs of 4 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete including fittings such as switches ceiling roses, pendent, regulators, sockets, MCB/ MCCB/ MCB DB/ earth plug and socket etc and making good matching to the existing colour to the disturbed surface.
M&L for colour code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit /PVC casing caping not less than 20 mm of medium grade including modular metal flush box fitted with modular cover plate with frame (inner/ outer plate) including FRLS 1.5 sqmm earth wire copper insulated connected to common earth dolly complete all as specified and directed by Engineer in charge for the following:-
(a) One light/fan point controlled by one switch.
(b) One 3 pin socket outlet 6 Amps on the same board with other switches.
(c) 6 Amps socket point on independent board.
All as per item no 17 here in above but 2.5 sqmm for 5/15 Amps socket on independent board complete all as specified and directed by Engineer in charge.
S&F in repair modular switch 1 way 6 Amps 1 module suitable for fixing existing cover plate complete all as specified and directed by Engineer in charge.
S&F in repair modular switch 1 way 16 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in repair modular socket 6 Amps 2/3 pin combined 2 module suitable for fixing existing cover plate complete all as specified and directed by Engineer in charge.
S&F in repair modular socket 6/16 Amps 2/3 pin combined 2 module suitable for fixing existing cover plate complete all as specified and directed by Engineer in charge.
S&F in repair switch piano, flush type single pole, one way 5 Amp complete all as specified and directed by Engineer in charge.
S&F in repair socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed by Engineer in charge.
S&F switch socket combination 5 pin, 6 Amp ISI marked with PVC box complete all as specified and directed by Engineer in charge.
S&F in repair modular fan step regulator 120W, electronic 2 module step up type AC 230 Volts complete all as specified and directed by Engineer in charge.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten/bracket fittings complete all as specified and directed by Engineer in charge.
S&F in repair single pole and neutral enclosure with two pin and plug and socket complete with one single pole MCB 'C' series, AC 240 Volts, 20 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCB protected socket PVC plastic base model with one single pole MCB 'C' series, AC 240 Volts,25/32 Amps complete all as specified and directed by Engineer in charge.
S&F in repair triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amp 'C' series 415 Volts complete all as specified and directed by Engineer in charge.
S&F in repair modular white cover plate with frame, 2 module complete all as specified and directed by Engineer in charge.
All as per item no.31 here in above but 4 module complete all as specified and directed by Engineer in charge.
All as per item no.31 here in above but 6/8 module complete all as specified and directed by Engineer in charge.
All as per item no.31 here in above but 12 module complete all as specified and directed by Engineer in charge.
S&F in repair modular box suitable for fixing 1/2/3 module complete all as specified and directed by Engineer in charge. Note:- The rate quoted for replacing of modular box is deemed to be inclusive of necessary cement/putty work and finishing work for white wash /colur wash matching with existing surface.
S&F in repair modular box suitable for fixing 4 module complete all as specified and directed by Engineer in charge. Note:- The rate quoted for replacing of modular box is deemed to be inclusive of necessary cement/putty work and finishing work for white wash /colur wash matching with existing surface.
S&F in repair modular box suitable for fixing 6 module complete all as specified and directed by Engineer in charge. Note:- The rate quoted for replacing of modular box is deemed to be inclusive of necessary cement/putty work and finishing work for white wash /colur wash matching with existing surface.
S&F in repair modular box suitable for fixing 8/12 module complete all as specified and directed by Engineer in charge. Note:- The rate quoted for replacing of modular box is deemed to be inclusive of necessary cement/putty work and finishing work for white wash /colur wash matching with existing surface.
S&F in repair MCB DB SPN 230V double door type with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete all as specified and directed by Engineer in charge of following size :-
S&F in repair MCB DB TPN 415V double door type with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail suitable for fixing existing space and model vertical or horizontal complete with making good as per the existing surface all as specified and directed by Engineer in charge complete of following size:-
S&F in repair VTPN MCCB DB 415V double door type 8 way with bus bar of appropriate current carrying capacity,isolated neutral link, earth bar suitable for fixing of MCCB four pole 100 A/ 125 A/ 160 Amp and din rail suitable for fixing existing space and model vertical complete with making good as per the existing surface all as specified and directed by Engineer in charge.
S&F in repair MCB single pole AC 240 Volts, C series 50 Hz 10 kA breaking capacity, 6 to32 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCB single pole & neutral AC 240 Volts, 50 Hz ,C series 10 kA breaking capacity, 6 to 32 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCB single pole & neutral AC 240 Volts, 50 Hz , C series 10 kA breaking capacity, 40 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCB triple pole & neutral AC 240 Volts, 50 Hz , C series 10 kA breaking capacity, 40 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCB triple pole & neutral AC 240 Volts, 50 Hz , C series 10 kA breaking capacity, 63 Amps complete all as specified and directed by Engineer in charge.
S&F in repair capacitors 4 mfd, AC 440 Volts suitable for Exhaust fan complete all as specified and directed by Engineer in charge.
S&F in repair capacitors 2.5mfd, AC 440 Volts suitable for celling fan/exhaust fan complete all as specified and directed by Engineer in charge.
Dismantling of ceiling fan of 1200 mm sweep of any make and model,removing the defective burnt windings,rewinding the same with appropriate gauges of super enamelled copper winding wire including varnishing, drying and reassembling,refixing,making electrical connection complete in all respect all as specified and directed by Engineer in charge.
Dismantling of exhaust fan of 300/450 mm sweep / wall mounted fan of any make and model ,removing the defective burnt windings ,rewinding the same with super enamelled copper winding wire of appropriate gauge including varnishing, drying and reassembling , refixing,making electrical connecting complete in all respect all as directed .
S&F in repair MCCB four pole 100 Amps 16/18 kA 415 Volts, 50 Hz suitable for existing busbar complete all as specified and directed by Engineer in charge.
S&F MCCB four pole 160 Amps 25 kA 415 Volts, 50 Hz suitable for existing busbar complete all as specified and directed by Engineer in charge.
Disconnect electric connections and taking down carefully unserviceable Ceiling light/ Highbay light fittings of different capacities at Nalanda Main Bldg /Aryabhatta/Bhaskara/Panini Library by opening of cover and body for repair/ replacement of electrical items and refixing the same or fixing only new items /fittings including connecting/ testing complete. Note:- (a) Fitting are fitted at 16 to 20 mtr height.The contractor shall arrange ladder/ scaffolding of required height at his own arrangement.The rates quoted are deemed to be included for the above provision.
M&L for LED recessed full lit luminaire driver (Choke) with longer life less maintenance suitable for 2 feet x 2 feet Panel light complete all as specified and directed by Engineer in charge. Make:- Crompton/Havells/Philips
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground, earth pit not less than 2.25 meter deep below ground level, connected to 25x4 mm size galvanized iron strip as earthing strip by means of bolts, nuts, check nuts, and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including provn of necessary excavation and earthwork in any type of soil, PCC pit, RCC cover and 20 mm bore medium grade watering pipe, water funnel with GI wire mesh, 40 mm bore medium grade protection pipe, common salt, charcoal dust, returning filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed by Engineer in charge.
M&L for earth continuity conductor or main earthing lead fixed to wall on epoxy /OMC insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete all as specified and directed by Engineer in charge.
All as per item no.56 above but copper strip 20x3 mm size complete all as specified and directed by Engineer in charge.
Notes:- Maintenance and repairs shall be carried out immediately on receipt of complaint from users. The rate quoted for all items shall be deemed to be inclusive of the following provisions :- (a) Depute one electrician and one helper to attend the day to day complaint during the entire contract period. (b) To provide transportation arrangement to shift the materials. (c) Provide necessary tools and plants for attending the complaints. (d) Attend and complete the complaint within 24 Hrs. (e) If contractor fails to depute one electrician and helper for attending complaints a sum of Rs. 1200 per day will be recovered from payment.
Sreekrupa Enterprises
Jack Electrolinks Private Limited
ANAND REFRIGERATION
pk janardhanan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .