Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC VALID AND ADMITTED | |
| 2 | L2₹15.6 L+₹39,634 (2.61%)Rejected-AOC | L2 | Rejected-AOC VALID AND ADMITTED | |
| 3 | L3₹18.9 L+₹3.7 L (24.3%)Rejected-AOC | L3 | Rejected-AOC VALID AND ADMITTED |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
25 Jan 2020, 6:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2019_MES_309235_1
8489
Open Tender
Civil Works
Item Rate
120 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹46,000
Yes
24 Feb 2020
28 Dec 2019
30 Jan 2020
28 Dec 2019
25 Jan 2020
31 Dec 2019
28 Dec 2019 - 28 Dec 2019
Amount
Material and labour for Sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two/three/four/five/six single core 1100 V grade PVC insulated unsheathed FRLS cable with stranded copper conductor of nominal cross section area as under drawn into and including surface PVC non metallic rigid conduit of suitable size as per SSR Part-I with and incl PVC insulated unsheathed FRLS stranded copper conductor of nominal cross section area as under continous earth continuity wire complete all as specified and as described in Item No. 1.00 to 1.05.
Four runs of 16 Sq mm as current carrying conductor and two runs of 16 Sq mm as earth conductor in 40mm dia non metallic PVC conduit (Six runs of cable and one run of conduit shall be measured as one unit)
Four runs of 10 Sq mm as current carrying conductor and two runs of 10 Sq mm as earth conductor in 32mm dia non metallic PVC conduit (Six runs of cable and one run of conduit shall be measured as one unit)
Four runs of 6 Sq mm as current carrying conductor and two run of 6 Sq mm as earth conductor in 25mm dia non metallic PVC conduit (Six runs of cable and one run of conduit shall be measured as one unit)
Two runs of 6.0 Sq mm as current carrying conductor and one run of 6 Sq mm as earth conductor in 20mm dia non metallic PVC conduit (Three runs of cable and one run of conduit shall be measured as one unit)
Two runs of 4.0 Sq mm as current carrying conductor and one run of 4 Sq mm as earth conductor in 20mm dia non metallic PVC conduit (Three runs of cable and one run of conduit shall be measured as one unit)
Supply , installation & commissioning MCB Load Distribution board Vertical type TPN double door, for mounting of MCCBs as Incomer and DP/ SP/TP/ MCBs as outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The MCCB/DP/SP/TP MCB shall be of same make as DB. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified including dismantling of existing DB.The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed at site .Make - Legrand/Schneider/L&T/C&S
DB VTPN 6 way (MCCB + 18 SP)
DB VTPN 4 Way (MCCB + 12 SP) Note : Rates deemed to be included for carefully disconnecting all existing light/power/AC circuits wires from old deteriorated MCB distributin boards MCB's and reconnecting the same circuits to new MCB distribution boards MCB's(As per item 2.01 & 2.02) and testing for smooth fucntioning of circuits complete all as specified and directed.
Supply and Fix in repair MCCB TPN,160 Amps 4-Pole, 415 volts, breaking capacity 36 KA complete all as specified(In VTPN 6 Way as Incomer)
Supply and Fix in repair MCCB TPN,125 Amps 4-Pole, 415 volts, breaking capacity16 KA complete all as specified (In VTPN 4 Way as Incomer)
Supply and Fix in repair MCCB TPN,63 Amps 4-Pole, 415 volts, breaking capacity16 KA complete all as specified (In VTPN 4 Way as Incomer)
S/Fix in repair MCB DB factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc.Make - Legrand/Schneider/L&T/C&S completed of following sizes:-
SPN 08 way
TPN 4 way
S&F in repairs MCBs 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB (DB will be measured and paid separately under respective items of sch A)Make - Legrand/Schneider/L&T/C&S:-
MCB SPN 40 Amps.
MCB SP 5 to 32 Amps 'C' Curve
MCB TPN upto 63 Amps
MCB TP upto 63 Amps
Supply and fix in repair sheet metal enclosure single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps,240V, 50 Hz complete all as specified and directed Make : Legrand/C&S/Schneider/L&T
M & L for replacement of on load change over switch 4 Pole, 415 Volt, 100 Amps complete with sheet steel enclosure Make-L&T/HPL/Schneider all as specified & directed.
M & L for replacement of on load change over switch 4 Pole, 415 Volt,125 Amps complete with sheet steel enclosure Make-L&T/HPL/Schneider complete all as specified & directed.
Supply and fix, testing and commissioning AC three phase LT CT operated Multifunction Trivector Meter in Poly carbonated body Class 0.5 (Base Mounting), 3x 240 V, 50 Hz, LCD display,backlit, WIH Optical & RS232 port, confirming to IS-13779 and relevant IEC standards, anti-tamper features, including suitable CTs for smooth functioning . Similar to Cat part No TLBP28231300000CA0 of make HPL or in equivalent model of make L&T/Capital/Cyantech. (Note : Old unserviceabl will be deposited in AGE E/M store)
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed
M&L for sand cushoning, to cable with river sand and punning to provide required cover for UG cables all as directed at site. (Punned thickness shall be measured and paid)
M&L brick protection cover to electric cable with class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm.
Supply and laying in trenches,XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 70 sq. mm 3.5 Core.
Supply and fixing on wall/pole or passing through pipe,XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 70 sq. mm 3.5 Core.
Supply and laying in trenches ,XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 35 sq. mm 3.5 Core .
Supply and fixing on wall/pole or passing through pipe,XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 35 sq. mm 3.5 Core .
M&L for galvanized steel tubing light Grade of 80 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
M&L for galvanized steel tubing light Grade of 50 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
M&L for horizontal boring under roads for crossing/passing of cable at suitable depth. Horizontal boring under roads to be done manually without causing any damage to existing road. Dia of horizontal boring should be suitable to lay 80mm dia GI pipe.
M&L earthing complete with galvanized steel earth plate electrode 600mmX600mmX6mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, CI Cover with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe15mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Supply and fix Deep freezer Metal top not less than 320 litre capacity Single phase tempreture renge not less than <-18 degree centrigrate having Double door. BEE 5 star rating all as specified as directed by Engr in Charge make- VOLTAS /BLUE STAR/CARRIER
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA. Make: Microtek, V guard, Vintec
M&L point wiring complete with 2.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC conduit, medium grade minimum 19mm dia ISI marked and conduit accessories fixed on wall/ceiling /roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings, switches, sockets outlets, regulators etc complete including provisining of 2.5 sqmm PVC insulated unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for 15/16 amp multi purpose socket combination point on independent board.
M&L Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal.
S & F MCBs DB SPN 4 way factory made IP 42 protection class metal single door with 200 Amp rating bus bar 240/430V complete all as directed by Engr-incharge. Make: C&S/Havells/HPL
Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 2.5 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 2.5 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. NOTE : Two runs of single core 2.5 sqmm and one run of 2.5 sqmm copper FRLS cable as earth continuity conductor and PVC conduit with accessories shall be measured as one unit .
Supply and fix air cooled split type unit indoor/ outdoor air conditioner with copper condenser coil complete with cordless remote control unit and electric driven, single phase of capacity of 1.5 Ton, BEE 3 star rated make VOLTAS ,LG,BLUE STAR (The quoted rate shall be inclusive of making good exisitng surfaces).
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA Suitable for 1.5 Ton AC. Make: Microtek, V guard, Vintec
M&L for galvanized steel tubing light Grade of 40 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Supply, installation & commissioning MCB Load Distribution board Vertical type TPN 4 Way double door, for mounting of MCCBs as Incomer and DP/ SP/TP/ MCBs as outgoing, factory made, confirming to IS.The DBs shall be double door type with hinged door with locking arrangement. The MCCB/DP/SP/TP MCB shall be of same make as DB. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed at site .Make - Legrand/Schneider/L&T/C&S
Supply and Fix only MCCB 100 Amps, 4-Pole, 415 volts,50 Hz, breaking capacity 16 KA with all necessary lugs and glands etc complete all as specified and directed .Make - Legrand/Schneider/L&T/C&S (In VTPN 4 Way as Incomer)
Supply and fix sheet metal enclosure Triple pole and neutral encolsure with a three pin and earth plug with socket complete with one triple pole MCB one triple pole MCB 63 Amps,415V, 50 Hz complete all as specified and directed.Legrand/Schneider/L&T/C&S
MCB SP 5 to 32 Amps 'C' Curve.Make - Legrand/Schneider/L&T/C&S
MCB TPN upto 63 Amps.Make - Legrand/Schneider/L&T/C&S
Earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to and including GI earth strip 32 X 6 mm dia GI earth lead as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete
M&L for making hole in existing wall of 230mm thickness, suitable for housing of 380/300/250/200 mm sweep Exhaust fan complete including grouting of 04 Nos bolt fasteners, PCC work etc including making good disturbed surfaces all as specied and as directed by Engineer in charge.
M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC conduit, medium grade minimum 20mm dia ISI marked and conduit accessories fixed on wall/ceiling /roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings, switches, sockets outlets, regulators etc complete including provisioning of 1.5 sqmm PVC insulated unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :-
One exhaust point controlled by one switch 6 Amp one way
M&L switch piano flush type single pole, one way 6amp .
Supply and fix ceiling rose 65x17mm three terminals .
Supply, fixing, testing & commissioning of Iron body exhaust fan 300 mm sweep 1400 RPM with minimum airflow/air delivery 1710 Cmh, totally enclosed heavy duty motor, die cast aluminium rotor mounted on double ball bearing, IP-55, polarity-4, 230 Volt AC supply (single phase), rated power input not more that 90watt, with louvers fixed outside bldg for auto opening and closiing and connecting up including provison of PVC insulated overall PVC sheathed copper conductor cable from ceiling rose to fan. Make : CG/Bajaj/Havells or equivalent. Similar to Crompton Greaves model No EXHD300-4-1
Supply, fixing, testing & commissioning of Exhaust fan 225 mm sweep, metal body rust proof body & blades, with louvers for protection from birds, 230 Volt AC supply, rated power input not more that 45watt, with louvers fixed outside bldg for auto opening and closing connecting up including provison of cable from ceiling rose to fan. Make : CG/Bajaj/Havells or equivalent. Similar to Crompton Greaves model No Trans Air 9"
Shiv Projects
PATELS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .