| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.7 L+₹2.9 L (9.87%)Rejected-Finance 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹35.7 L+₹6.0 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹36.7 L+₹7.0 L (23.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹39.8 L
EMD Value
₹79,660
Closing Date
29 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) BAREILLY
GE(AF) BAREILLY-243002
PROVN OF CERTAIN EM MINOR WORKS AND WORKS SERVICES FOR REPLACEMENT OF HANGAR DOOR MOTORS AT AIR FORCE STN BAREILLY UNDER GE (AF) BAREILLY
2024_MES_677607_1
GE(AF)/BLY/T-40/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) BAREILLY
₹79,660
Yes
3 Dec 2024
1 Oct 2024
31 Oct 2024
1 Oct 2024
29 Oct 2024
16 Oct 2024
Amount
Supply, install, testing & commissioning of split type air conditioner of capacity 1.5 TR, wall mounted type, working on single phase, 240 volts, 50 Hz AC, R-32 CFC free refrigerant with cordless remote control unit, inverter type (variable speed), BEE 5 Star rating complete with 100% copper condenser coil including fixing of indoor and outdoor unit with necessary copper pipe connections including cutting, bending, brazing, insulation on pipe, PVC drain pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated multi-stranded copper cable complete all as directed by Engineer-in-Charge. [Make: Blue Star /Voltas/ Carrier] Note: (a) Power cable between indoor and outdoor unit, copper piping (3.0 mtr) with heat/ cold resistant nitrile rubber/ foam type insulation, iron stand powder coated for outdoor unit and drain pipe up to the ground level shall be deemed to be included in quoted rate of this item. (b) It is the responsibility of contractor to fill the blanks/ holes made for copper piping and drain system to install the ACs to match with the existing surface.
S&F for wall mounted voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage satbilized at 230 volt with accuracy +/- 2.5% and speed of correction 8 volts per second of capacity 4 KVA complete all as specified and directed. Make:Microtek/Bluebird/V Guard.
S&F for Single Pole and Neutral enclosures with two pin and earth plug & socket 240 volt complete with one number Single Pole MCB 20 Amp complete all as specified and directed.
S&F for MCB Single Pole & Neutral, 240 Volts, 63 Amps 50Hz, 16 KA. 'C' series all as specified and directed.
S&F for MCB Single Pole 240 volts, 5 to 32 Amps, 50HZ, 10 KA, ‘C’ series all as specified and directed.
S&F for sheet metal enclosures MCB distribution board, Single pole and Neutral 220 Volts, 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting chases in wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed.
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 4 Sqmm 1100 Volts grade and one run of PVC insulated unsheathed stranded copper conductor FRLS cable of size 4 Sqmm 100 Volts grade as earth continuity conductor drawn through in and including rigid non metallec PVC casing caping on roof/ wall/ ceiling including making good the disturbed surfaces of wall etc complete all as directed. (Note :- Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
Supply , laying & testing XLPE insulated , armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 2 core complete all as specified and directed.
M&L for dry sand cushioning to underground cables with 8 cm thick before laying of cable and 15 cm thick after laying and stretching of cable complete all as specified. (Note : Only punned thickness i.e. 18 cm shall be measured and paid).
M&L for sub class 'B' brick for covering to under ground cable laid dry flat transversally width equal to the length of the cable all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in any type of soil for laying of cables, foundation of poles, and stay assembly all as specified and directed.
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25CM thick all as specified and directed .
Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge .
Supply and fixing bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.2 ltrs, heating capacity 0.9 ltrs/hr working with CFC free refrigerant complete all as specified and directed by Engr-in-Charge. Make:VOLTAS/ CROMA /BLUE STAR
Supply, installation, commissioning and testing of refrigerator, electric driven, single phase of capacity 175 ltrs , frost free, direct cool, single door, CFC free refrigerant, 2 star rated, including making connections complete all as specified and directed by Engr-in-Charge. Make:LG/ SAMSUNG /HAIER/Whirlpool/Lloyd.
M&L for point wiring with 1.5 Sqmm FRLSH PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade drawn in and including concealed non-metallic rigid PVC conduit medium grade with all fittings (ISI Marked) not less than 20 mm external dia but shall be increased as per actual site reqmt in accordance with clause no 19.125 of SSR Part- I fixed concealed / recessed in wall / ceiling etc including 1.5 Sqmm FRLSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts gradeas earth continuity wire including MS sunken pressed steel terminal boxes of suitable size, made of sheet 1.6mm thick with 3.0 mm thick bakelite sheet top cover for one light point/fan point controlled by one way switch complete all as specified.
S&F for wall mounted fan 40 mm sweep, 230 Volt, AC with built in regulator and swing function including electric connecion from ceiling rose to fan connector with PVC insulated 2 core copper cable size 0.75 Sqmm complete including taking down existing fan and handing over to AGE E/M store all as directed. (Make: 'Swing' of Havells or its equivalent in Almonard/Bajaj/Crompton)
S&F for ceiling rose, surface bakelite, 65 mm x 50mm, three terminals all as specified and directed.
S&F for switch piano flush type single pole one way 5/6 Amp complete all as specified and directed.
Supply, installing, testing and commissioning, factory assembled diesel Engine driven generating set , fully wired alternator AC to given an output of 30 KVA, CPCB IV+, continuously rating at a PF of 0.8 lagging, 415 Volts AC 3 phase 4 wire 50 Hz +/-1% supply, 1500 RPM, directly coupled with diesel engine. DG Set shall be water cooled mounted on common base frame complete with fuel tank provided within canopy on base frame (Service tank) of adequate capacity with fuel line and accssories, PCC foundation work as per manufacturer instructions, vibration and damper pads, control panel and other accessories etc and comprising of the following:- (a) Radiator with blower fan or heat exchanger with guard (b) Pipe coupling for engine cooling system piping (c) Corrosion inhbitor coolant (d) Paper element filters (i) Fuel (ii) Lube oil (e) Fly wheel housing and fly wheel to suit alternator (f) Engine bearing machanism in fly wheel housing (g) Shunt off coil with safeties for LLOP/HWT/over speed (h) Dry type air cleaners and vaccum indicators (j) Residential silencers (k) Stainless steel exhaust flexible bellows (l) Battery charging alternator (m) Exhaust priming made out of STIC class 'C', MS pipe inclusive of all accessories and hardware, necessary support scaffoldiong as per manufacturer's recommendations to sustain back pressure with rain cap (n) Mineral wool insulation 2" thick suitable for 400 temperature claded with aluminum sheet of 30 guage for the entire length of the exhaust pipe (o) First fill of oil, coolent and diesel during testing (p) Interconnecting copper cabling of adequate capacity between batteries control (q) Fuel pipe class 'C' STIC 1"/1.5"/2" dia - 01 lot (r) Self starter of suitable capacity (s) Electronic governor (t) Fuel injection pump (u) Electronic instrument panel complete with all accessories as per manufacturer specifications displaying the following :- (i) Battery voltage & battery charging indicator. (ii) Water temperature (iii) Lubricating oil pressure (iv) Engine speed (v) Engine hours (vi) Freqency (vii) Voltage (w) Emergency stop button (x) Safety control (Trip and indication) (i) High water temperature (ii) Low lube oil pressure (y) Base Frame :- Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer design alongwith AVM pads. (z) Battery 12 Volts, 120AH, maintenance free with leads and terminals (Make - Exide/Amron)-01 No (aa) Fuel tank :- Not less then 08 Hrs full load diesel storage capacity fuel tanks with mounting brackets factory made of 5 mm thick HR/MS sheet with level indicator fuel outlet, fuel inlet, air vent, drain plug, inlet arrangement for diesel filling from exterior of canopy (without opening its panel etc, complete all as specified. (ab) Alternator :- Suitable rated at 30 KVA at 0.8 PF, 415 Volts, 3 Phase, 4 wire 50 Hz, at 1500 RPM, self excited and self regulated with AVR brushless excitation, screen protected, drip proof, Insuylation class H IP-23, self ventilated and conforming to BS: 5000/IS : 4722 suitable for engine as mentioned here in before. (ac) Acoustic Enclosure : M&L for acoustic enclosure of suitable size as per manufacturer design for the above 30 KVA DG Set to reduce noise level to 75db measured at 1.0 m distance for auidable frequencies as per guidelines of central pollution control board and manufacturer specification and comprising of following from authorised OEMs of Gen set Manufacturers specified : (i) Sound insulation 100 mm thick rock wool (density 64 kg/cum) (ii) Outer body : 1.6 mm thick CRCA (iii) Door : 1.6 mm thick CRCA (iv) Inner surface : 1.0 mm thick CRCA/GI sheet (v) Base frame:" ISMC 300 (vi) Inside illumination: 01 No - 1x15 watts LED fitting of make Philips/Bajaj/Crompton.
Supply, laying and testing XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete specified and directed by Engr-in-Charge.
M&L for horizontal boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes of 40mm bore and making good the disturbed surface complete all as specified and as directed. [Note: GI pipe will be measured and paid separately]
S&F for 40 mm bore galvanised iron tubing light grade with fittings for cable protection in floors/under roads/along poles etc. complete all as specified and directed. (Note: Clamps, nuts, bolts & washers etc as required shall be deemed included in the unit rate of this item)
S&F for OFF LOAD changeover switch 415 Volt in sheet metal enclosure 4 pole of capacity 100 Amp complete all as specified and directed. Make - C&S Cat part No CSCSOF100CO4RE or its equivalent in Havells/ Legrand)
S&F for OFF LOAD changeover switch 415V in sheet metal enclosure 4 pole of capacity 63 Amp complete all as specified and directed. (Make - C&S Cat part No CSCSOF63CO4RE or its equivalent in Havells/ Legrand)
M&L for earthing complete with galvanized earth plate electrode of size 60 Cm x 60 Cm x 6 mm buried directly in ground vertically at a depth not less then 2.25 mtrs below normal ground level with top edge of earth plate at a depth not less then 1.5 mtrs below normal ground level surrounded from all sides by 15 Cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanized iron strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers made of galvanized iron and protected by light grade 40 mm dia GI pipe upto test point or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:3:6 type C-2 (using 40 mm grade stone aggregate) including excavation and earth work in any type of soil, returning, filling in soil and disposal of surplus soil to a distance not exceeding 50 mtrs all as specified and shown on plate No 05 of SSR Part I.
S&F for sheet metal enclosures MCB distribution board, Three Pole and Neutral 415 Volts, 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting chases in wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed.
S&F for MCB Triple Pole & Neutral, 415 Volts, 63 Amps with rupturing capacity 10 KA, complete all as specified.
Supply , laying & testing XLPE insulated , armoured, Heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm 3.5 core complete all as specified and directed.
M&L for sub main wiring complete with two single core multi stranded copper conductor 2.5 Sqmm (nominal area) PVC insulated unsheathed cable drawn in and including medium grade PVC conduit ISI Marked not less than 25 mm dia concealed including making good distrubed surface of wall including single core multi stranded copper conductor 2.5 sqmm size as earth wire drawn in same conduit including taking down existing submain wiring complete all as specified and directed(Note: One run of two single core copper wire 2.5 Sqmm and one run of 2.5 Sqmm copper earth wire and one run of conduit shall be measured as one unit).
M&L for sub main wiring complete with two single core multi stranded copper conductor 6.0 Sqmm (nominal area) PVC insulated unsheathed cable drawn in and including medium grade PVC conduit ISI Marked not less than 25 mm dia concealed including making good distrubed surface of wall including single core multi stranded copper conductor 6.0 sqmm size as earth wire drawn in same conduit including taking down existing submain wiring complete all as specified and directed (Note: One run of two single core copper wire 6.0 Sqmm and one run copper earth wire of 6.0 Sqmm and one run of conduit shall be measured as one unit).
Supply, laying and testing XLPE LT insulated, screened PVC bedded galvanised steel strip armoured, electric power cables (heavy duty) 1100 volts grade with standard aluminium conductor of size 25 Sqmm 4 Core including taking down existing cable complete all as specified.
Supply, laying and testing XLPE LT insulated, screened PVC bedded galvanised steel strip armoured, electric power cables (heavy duty) 1100 volts grade with standard aluminium conductor of size 16 Sqmm 4 Core including taking down existing cable complete all as specified.
S&F in replacement of factory made epoxy powder coated distribution board SPN 8 way 240 Volt (SPN MCB DB) with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail , earth bar and cable ties for cable management , top and bottom removable gland plates withknockouts complete all as specified and directed
S&F in replacement of teeth gear of chain required for operating of hanger gate complete all as specified and directed by Engr-in-Charge.
S&F in replacement of chain of teeth gear required for operating of hanger gate complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TP 20 Amp 'C' curve compete all as specified.
S&F in replacement of motor protection circuit Breaker switch, 415 volts suitable for 3 phase 1.5 KW Induction motor with thermal protection adjusting range 2.5-4.0.complete all as specified.
S&F in replacement of Mini contactor AC, three pole upto 6 Amp, 415 volts, 50 Hz complete all as specified.
S&F in replacement of MCB, SPN, 6 to 32 Amp, 240 Volt, 'C' curve breaking capacity 10 KA complete all as specified.
S&F in repair flexible copper conductor cable of size 2.50 Sqmm 4 core PVC insulated and sheathed, 1100 Volt grade multi stranded complete all as specified.
S&F in replacement of push button switch for hanger doors with elements 6 Amp, 415 Volts, 50 Hz complete all as specified.
S&F in replacement of geared rotary limit switch 3 phase, 415 Volts, 50 Hz, 10 Amp No. 22-1210-2 KV suitable for hanger doors any capacity and any motion complete all as specified.
S&F in replacement of cable carrier complete all as specifed and directed.
S&F in replacement of motorization system of hangar door including copper wound motor capacity not less than 1.5 HP including fixing arrangement all accessories with facility of manual operation, Idler braking system, safety hooter cum flasher, auto limit power cut off, weather proof control panel with safety of motor system complete with a guarantee period of 24 months for smooth jurk free forward and reverse smooth operation of door without any indication of de-railing from track fully enclosed motor gear idler braking assembly with manual declutching facility chain sprocket assembly with foundation one for each leaf of size not less than 5m x10m with weather proof control panel with safety device one for each motor system i.e for each leaf and auto power cut limit switches one pair for each motor system i.e for each leaf and hooter cum flasher - one for each motor system motor system i.e for each leaf and fire rated XLPE cable 4 Sqmm 4 core in suitable length for each motor system i.e for each leaf and fire rated XLPE cable 0.75 Sqmm 2 core in suitable lenth for each motor system i.e for each leaf and Fire rated MS Conduit of suitable dia suitable length for each motor system i.e for each leaf and fasten C- Channel slider/rope wire cable carrier arrangement complete for each motor system complete all as speciifed and directed by Engr-in-Charge.
M&L for rewinding of electric motors with suitable copper winding wire of 6.7 KW, 3 Phase, 920 / 960 RPM Electric Motor along with class 'B' insulation with and including dismantling, transporting, re-fixing and testing on full load complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of electric motors with suitable copper winding wire of 4.5 KW, 3 Phase, 920 / 960 RPM Electric Motor along with class 'B' insulation with and including dismantling, transporting, re-fixing and testing on full load complete all as specified and directed by Engr-in-Charge.
M&L for horizontal boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes up to 100 mm bore and making good the disturbed surface complete all as specified and as directed by Engr-in-Charge.
S&F in repair Galvanised iron tube 80 mm bore light grade with all fittings and laid in trenches or inserting in horizontal boring complete all as specified.
S&F in replacement of MCB Single Pole 240 volts, 6 to 32 Amps, 50HZ, 10 KA, ‘C’ series all as specified and directed.
Vishal Traders (BID ID -3151178)
M/s Agarwal Builders (BID ID -3146975)
VINYAK TRADERS (BID ID -3152642)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .