Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹49.0 L+₹6.8 L (16.1%)Rejected-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹49.7 L+₹7.6 L (17.9%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹51.8 L+₹9.7 L (22.9%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹52.9 L+₹10.7 L (25.4%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
Refer Docs
Closing Date
5 Jan 2023, 6:00 pmClosed
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160003
SPECIAL REPAIR TO CERTAIN E/M INFRASTRUCTURE, PANELS AND CABLES OF DG SET/AC PLANT AND OTHER ASSOCIATED WORKS AT AF STN CHANDIGARH
2022_MES_565899_1
CWE/AF CHD/CHD/T-42/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per NIT
8 documents required · 8 mandatory
₹1,000
GE(AF) Chandigarh
Exempted
15 Feb 2023
29 Nov 2022
12 Jan 2023
29 Nov 2022
5 Jan 2023
22 Dec 2022
Amount
Note for item No 1 to 8 :- All MCCBs shall be fitted with phase separators and spreador links on both incoming and outgoing sides. All connections from main bus bars to incoming side of MCCB shall be done with colour code aluminium strips of suitable size. Legs of panel shall be fabricated out of 50mmx50mmx6mm MS angle iron. Unit rate quoted shall be deemed to include the cost of the same.
Material and labour for replacement of factory made LT feeder pillar box of size 750 mmx750 mm x 600 mm with 4 strip copper bus bar (200 Amp, 1100 volt grade, 600 mm long duly sleeved with relevant colored sleeve = 01 set), double door, outdoor type, weather proof , fabricated out of 3.15 mm CRCA sheet, welded on 40 X 40 X 6 mm angle iron frame & having four Nos of angle iron legs made out of 40 X 40 X 6 mm - 120 cm long below frame, grouted in ground with PCC 1:2:4 of suitable size block, with front & rear door, having locking arrangement, openable, bottom space for cable entry with & including powder coating, complete all as specified and directed
Supply and fixing water proof ABS electric distribution box , wheather proof, IP-65, suitable for out door use, pole mounted, made of MS, factory made, of size 300 x 250 x 150 mm, comprising of MCB SP 6 Amps, 240 Volts SPN bus bar not less than 25x5mm aluminium strip and fixing clamps of size 25 x 5 mm two nos, including necessary MS nut, bolts and locking arrangment with pressure type lock, connection hole four Nos each bus bar with nuts ,bolts and washer made of galvanised iron and connection thimble etc, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 185 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 50 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm 4 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm 2 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Material and labour for horizental boring of holes under road, Pavement, hard standing etc by trenchless technology using ultra sounding techique and necessary machine including supply and laying HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure in the drilled hole, complete all as specified and directed.
Supply, installation, connecting, testing and commissioning outdoor double door type 150 KVAr / 415 V APFC Panel board cubical type with MPP-H capacitor all as per manufacurer's design and specifications, of suitable size factory made, Rated Voltage 415 Vac, 3ø, 50 Hz, Delta Connection, Heavy Duty Cylindrical Capacitor compartment type, dust and vermin proof (IP-65 protection) suitable for 1100 volt grade 3 phase , 50 HZ AC , 4 wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX6 mm size angle iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 6mm, 120 cm long and with cable entry space in both side and with front door and back door openable/detachable having locking arrangement, inter connected with copper conductor strips and connected with suitable size thimbles/lugs with 11 tank process for corrosion proof powder coating including embedding legs in PCC 1:2:4 bed blocks of suitable size and with provision of bottom cable entry , double side earthing connection ( Ref. Standard: IEC 61921/ IS 8623 / IS 16636 / IEC 61439 ) complete all as specified and directed and complete with the following accessories :-
OUTGOING :- (a) 150 KVAr heavy duty capacitor bank consisting of 8 steps (1 x 5 KVAr + 2x10 KVAr + 5x25 KVAr) (b) Each 5 KVAR step shall be fitted & including the following :- (Total steps- 01 No) [i] MCB 16A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 5 KVAR capacitor - 01 No [iii] 5 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No [viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required (c) Each 10 KVAR step shall be fitted & including the following :- (Total steps- 02 Nos) [i] MCB 32 A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 10 KVAR capacitor - 01 No [iii] 10 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No
[viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required (d) Each 25 KVAR step shall be fitted & including the following :- (Total steps- 05 Nos) [i] MCB 63 A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 25 KVAR capacitor - 01 No [iii] 25 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No [viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required [e] [i] Internal connections with colour coded copper strip bus bars of suitable size copper thimbles etc as per manufacturers design and specfification [ii] Danger notice plate 440 V with conventional skull and bones in red signal colour - 02 Nos
MISCLANEOUS :- [f] [i] FAN 8" (200mm) SWEEP 230V AC,AXIAL with thermostat - 02 Nos [ii] Earthing terminals - 02 Nos [iii] Continuous earthing strip alumimnium - As required and directed by Engr-in-Charge Notes : - 1. Principle Operation : - (i) To continuously sense and monitor the load conditions by the use of the external CT (whose output is fed to the control relay). (ii) To automatically switch ON and switch OFF relevant capacitor steps to ensure consistent power factor. (iii) To ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out etc. (iv) To protect against any electrical faults in a manner that will ensure safe isolation of the power factor correction equipment 2. MCCBs/ capacitors/APFC relay shall be of the same make only. MCCBs shall be fitted with phase separators and spreader links on both incoming and outgoing sides. Unit rate quoted shall be deemed to include the cost of the same.
Supply, installation, connecting, testing and commissioning outdoor double door type 200 KVAr / 415 V APFC Panel board cubical type with MPP-H capacitor all as per manufacurer's design and specifications, of suitable size factory made, Rated Voltage 415 Vac, 3ø, 50 Hz, Delta Connection, Heavy Duty Cylindrical Capacitor compartment type, dust and vermin proof (IP-65 protection) suitable for 1100 volt grade 3 phase , 50HZ AC , 4 wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX6 mm size angle iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 6mm, 120 cm long and with cable entry space in both side and with front door and back door openable/detachable having locking arrangement, inter connected with copper conductor strips and connected with suitable size thimbles/lugs with 11 tank process for corrosion proof powder coating including embedding legs in PCC 1:2:4 bed blocks of suitable size and with provision of bottom cable entry , double side earthing connection ( Ref. Standard: IEC 61921/ IS 8623 / IS 16636 / IEC 61439 ) complete all as specified and directed and complete with the following accessories:-
OUTGOING :- (a) 200 KVAr heavy duty capacitor bank consisting of 10 steps (1 x 5 KVAr + 2x10 KVAr + 7x25 KVAr) (b) Each 5 KVAR step shall be fitted & including the following :- (Total steps- 01 No) [i] MCB 16A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 5 KVAR capacitor - 01 No [iii] 5 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No [viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required (c) Each 10 KVAR step shall be fitted & including the following :- (Total steps- 02 Nos) [i] MCB 32 A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 10 KVAR capacitor - 01 No [iii] 10 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No
[viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required (d) Each 25 KVAR step will be fitted & including the following :- (Total steps- 07 Nos) [i] MCB 63 A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 25 KVAR capacitor - 01 No [iii] 25 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No [viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required [e] [i] Internal connections with colour coded copper strip bus bars of suitable size copper thimbles etc as per manufacturers design and specfification [ii] Danger notice plate 440 V with conventional skull and bones in red signal colour - 02 No
MISCLANEOUS :- [f] [i] FAN 8" (200mm) SWEEP 230V AC,AXIAL with thermostat - 02 Nos [ii] Earthing terminals - 02 Nos [iii] Continuous earthing strip alumimnium - As required and directed by Engr-in-Charge Notes : - 1. Principle Operation : - (i) To continuously sense and monitor the load conditions by the use of the external CT (whose output is fed to the control relay). (ii) To automatically switch ON and switch OFF relevant capacitor steps to ensure consistent power factor. (iii) To ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out etc. (iv) To protect against any electrical faults in a manner that will ensure safe isolation of the power factor correction equipment 2. MCCBs/ capacitors/APFC relay shall be of the same make only. MCCBs shall be fitted with phase separators and spreader links on both incoming and outgoing sides. Unit rate quoted shall be deemed to include the cost of the same.
Supply , installation, connecting, testing and commissioning outdoor double door type 250 KVAr / 415 V APFC Panel board cubical type with MPP-H capacitor all as per manufacurer's design and specifications, of suitable size factory made, rated Voltage 415 Vac, 3ø, 50 Hz, Delta Connection, Heavy Duty Cylindrical Capacitor compartment type, dust and vermin proof (IP-65 protection) suitable for 1100 volt grade 3 phase , 50HZ AC , 4 wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX6 mm size angle iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 6mm, 120 cm long and with cable entry space in both side and with front door and back door openable/detachable having locking arrangement, inter connected with copper conductor strips and connected with suitable size thimbles/lugs with 11 tank process for corrosion proof powder coating including embedding legs in PCC 1:2:4 bed blocks of suitable size and with provision of bottom cable entry , double side earthing connection ( Ref. Standard: IEC 61921/ IS 8623 / IS 16636 / IEC 61439 ) complete all as specified and directed and complete with the following accessories :-
OUTGOING :- (a) 250 KVAr heavy duty capacitor bank consisting of 10 steps (1 x 5 KVAr + 2x10 KVAr + 5x25 KVAr + 2x50 KVAr) (b) Each 5 KVAR step shall be fitted & including the following :- (Total steps- 01 No) [i] MCB 16A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 5 KVAR capacitor - 01 No [iii] 5 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No [viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required (c) Each 10 KVAR step shall be fitted & including the following :- (Total steps- 02 Nos) [i] MCB 32 A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 10 KVAR capacitor - 01 No [iii] 10 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No
[viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required (d) Each 25 KVAR step will be fitted & including the following :- (Total steps- 05 Nos) [i] MCB 63 A 10KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 25 KVAR capacitor - 01 No [iii] 25 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No [vii] Contact block 1 NO + 1NC - 01 No [viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required [e] Each 50 KVAR step will be fitted & including the following :- (Total steps- 05 Nos) [i] MCCB 125 A 25 KA TP - 01 No [ii] Power contactor four pole with 240V Coil suitable for 50 KVAR capacitor - 01 No [iii] 50 KVAR/440V/50Hz MPP-H 3PH heavy duty Capacitor - 01 No [iv] ON push button flush mounted green - 01 No [v] Contact block 1 NO - 01 No [vi] Off push button flush mounted red - 01 No
[vii] Contact block 1 NO + 1NC - 01 No [viii] ON indicator LED 240 VAC red - 01 No [ix] MCB,6A,SP for control - 01 No [x] Neutral link, relays , timers etc - As required [f] [i] Internal connections with colour coded copper strip bus bars of suitable size copper thimbles etc as per manufacturer's design and specfifications [ii] Danger notice plate 440 V with conventional skull and bones in red signal colour - 02 No
MISCLANEOUS :- [i] FAN 8" (200mm) SWEEP 230V AC,AXIAL with thermostat - 02 No [ii] Earthing terminals - 02 Nos [iii] Continuous earthing strip alumimnium - As required and directed by Engr-in-Charge Notes : - 1. Principle Operation : - (i) To continuously sense and monitor the load conditions by the use of the external CT (whose output is fed to the control relay). (ii) To automatically switch ON and switch OFF relevant capacitor steps to ensure consistent power factor. (iii) To ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out etc. (iv) To protect against any electrical faults in a manner that will ensure safe isolation of the power factor correction equipment 2. MCCBs/ capacitors/APFC relay shall be of the same make only. MCCBs shall be fitted with phase separators and spreader links on both incoming and outgoing sides. Unit rate quoted shall be deemed to include the cost of the same.
Material and labour in replacement route indicator for LT cable disc type of size 150 mm dia CI, 8 mm thickness, embossed with "MES LT CABLE" and fixed on angle iron 35x35x5 mmm 600mm long as directed and painted in anti corrosive yellow colour paint including PCC 1:2:4 type B-1 foundation block of size 300x300x300 mm, duly fixed in ground, complete all as specified directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth; for laying/taking out cables and foundations of poles etc and getting out complete all as specified and directed.
Returning and filling in excavated soil including spreading levelling, watering and well ramming in layers each not exceeding 25mm thick in soft/loose soil, complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting point, complete all as spcified and directed.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, 8cm in depth before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed. Note : Consolidated/punned thickness of 18 cm (overall) shall be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, class LV type 2 flat, size 300mm x 180mm x 40mm complete all as directed.
Taking out / down old existing LT 1100 volt grade cables 185 Sqmm, 95 Sqmm, 70 Sqmm, 50 Sqmm, 25 Sqmm , 16 Sqmm, size, laid in trenches, including bricks/Precast PCC cable cover for protection, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 40mm bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including MS clamps,nut,bolts etc, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 50mm bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including MS clamps,nut,bolts etc, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 100mm bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including MS clamps,nut,bolts etc, complete all as specified and directed.
Diconnecting the electric supply and all cable/earthing connections and taking out the existing unserviceable panel boards/APFC panels of any size and type incl removing from site complete all as direcetd.
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mmx6mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe medium grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 50mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 5 Ohm. In case the test results are not found below 5 Ohm, complete earthing will be redone without any extra cost to Govt.
Note: The Total amount shall subject to adjustment of credit of Rs. 1,18,075.00 for old Materials as per Schedule of Credit.
UNITED ENGINEERING CORPORATION
R D Bansal
M/S MATLOOB AHMED
HARISH SALES CORPORATION
SS BUILDERS
M/S BALWINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .