Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-Finance ADMITTED | |
| 2 | L2₹24.4 L+₹3.2 L (15.2%)Accepted-Finance | L2 | Accepted-Finance ADMITTED | |
| 3 | L3₹24.9 L+₹3.7 L (17.6%)Accepted-Finance | L3 | Accepted-Finance ADMITTED | |
| 4 | L4₹27.6 L+₹6.4 L (30.4%)Accepted-Finance | L4 | Accepted-Finance ADMITTED | |
| 5 | L5₹28.0 L+₹6.9 L (32.5%)Accepted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L5 | Accepted-Finance ADMITTED |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
3 Jul 2023, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
CERTAIN BR REPAIRS AND PERIODICAL SERVICES TO SINGLE TO MULTISTORIES BUILDINGS IN SVN COLONY GE COMPLEX AND MES KEY PERSONAL QUARTERS AT 104 AREA UNDER AGE BR I OF GE ND VISAKHAPATNAM
2023_MES_601022_1
8273GEND
Open Tender
Civil Works
Item Rate
240 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹74,000
6 Sept 2023
5 Jun 2023
8 Jul 2023
5 Jun 2023
3 Jul 2023
19 Jun 2023
Amount
The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work). NOTE:- Tenderers/bidders are advised to vist the site and see the buildings and quote their rate accordingly and no claim whatsoever in this regard shall be admissible at any later stage.
Preparing old decorated platered surfaces of walls by using vaccume based hand held or long handle sander machine and cleaning the surfaces by using Jet washer and applying one coat of cement based paint by using auto roller or airless sprayer machine complete all as specified and directed .
Complete removal of existing treatment on wall and prepration of surface by using vaccume based hand held or long handle sander machine and cleaning the surfaces by using Jet washer and applying 3 mm thick cement based wall putty by using automatic putty sprayer, (the putty shall be mixed with multipurpose mixer only) to achieve even and smooth surfaces and applying two coats of exterior weather proof (100% acryllic paint) over a coat of suitable primer by using auto roller or airless sprayer machiner over a coat of primer complete all as specified and directed
Prepration of old decorated surfaces of wall by using vaccume based hand held or long handle sander machine and cleaning the surfaces by using Jet washer and applying one coat of exterior weather proof (100% acryllic paint) by using auto roller or airless sprayer machiner over a coat of primer complete all as specified and directed
Complete removal of existing treatment on wall and prepration of surface by using vaccume based hand held or long handle sander machine and cleaning the surfaces by using Jet washer and applying two coats of exterior weather proof (100% acryllic paint) over a coat of suitable primer by using auto roller or airless sprayer machiner over a coat of primer complete all as specified and directed
Preparing old surfaces of walls by using vaccume based hand held or long handle sander machine and applying one coat of white wash by using auto roller complete all as specified and directed .
Preparing old surfaces of ceilings by using vaccume based hand held or long handle sander machine and applying one coat of white wash by using auto roller complete all as specified and directed .
M&L Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) by using auto roller or airless sprayer machine complete all as specified and as directed.
M&L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint by using auto roller or airless sprayer machine complete all as specified and as directed.
M&L Preparation of old painted concrete surfaces of any description, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) by using auto roller or airless sprayer machine complete all as specified and as directed.
Preparing old surfaces of walls by using vaccume based hand held or long handle sander machine and applying one coat of oil bound distemper by using Auto roller or Airless sprayer machine complete all as specified and directed .
Complete removal of existing treatment on wall and prepration of surface by using vaccume based hand held or long handle sander machine and applying 3 mm thick cement based wall putty by using automatic putty sprayer, (the putty shall be mixed with multipurpose mixer only) to achieve even and smooth surfaces and applying two coats of oil bound distemper over a coat of suitable primer by using auto roller or airless sprayer machiner over a coat of primer complete all as specified and directed
Removing plants /herbs grown on duct /wall portion, SWR pipes joint area for multistoried Buildings at any storey, Cleaning with steel brush and rubbish down all dirt, mud and Shabby materials from the SWR pipe joints & duct / wall portion complete and applied neat Cement slurry/cement mortar on the leakages of SWR pipe joints vertical stacks with Necessary safety measures i.e scaffoldings/hanging platform upto 9 floors complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick screed bed or bedding layers in CM 1:4 complete all as specified and directed.
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick screed bed or bedding layers in CM 1:4 complete all as specified and directed.
M&L for Non - skid coloured ceramic tiles 8 to 10 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in vertical surfaces like skirting, dado, risers of staircase etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM (1:4) as rough surface on vertical surfaces as backing coat of wall tiles complete all as specified and as directed.
M&L Glazed ceramic tiles in vertical surface 450x 300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including Screed bed or bedding layer of cement mortar (1:4) 15 mm thick for laying floor finishes complete all as specified and as directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc and removing rubbish off the premises complete all as specified and directed
M&L Machine cut kota stone slab 20-25 mm thick in flooring over and including cement screed base of 15 mm in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of The slab including rubbing and polishing complete all as specified and directed.
S & F Kota stone slab 25mm thick in riser of steps, skirting, dado and pillar laid over and including cement screed 10 mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting and polishing complete all as specified and directed.
M & L for injecting/ grouting cement slurry mixed with Conbextra EP 10 (Epoxy resin Injection grout) of M/s Fosroc Chemicals or equivalent approved chemical from list of makes as approved by GE in to roof/Sunken slabs of toilet by drilling holes at an interval not more than 1 M c/c to a depth of 60mm and 20 mm diameter and grouting the slurry by mechanical means with required Pressure including testing the sunken floor for 48 hours duly filled with water complete all as per manufacturers instructions and as directed by the Engineer-in-Charge. complete all as per technical specifications and as directed. [Note: The work shall be executed by authorised Applicator of the chemical Manufacturer and contractor will have to submit all necessary documents for the same]
M & L for Cutting / Chipping the spalled loose concrete of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Zinc rich epoxy primer to all steel surfaces as antirust agent and welding steel wire Fabric / Mesh of aperture 75mm and 2mm dia of wire to existing reinforcement, applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd as per manufacturer's instructions and providing pressure Guniting not exceeding 25 mm (average thickness) at a pressure of not less than 6 KG / Sqcm in CM 1:3 duly mixing the mortar with and including polycrete admixture of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 2% of weight of cement, finishing the surface rough and finally rendering with 15 mm thick in CM 1:4 and finishing the top surface even and smooth without using extra cement conforming to proper geometrics to match with the existing surface including providing double scaffolding and safety measures as required and removal of the same on completion and disposal of demolished materials / debris outside MD land complete all as specified and as directed. (Note:(a) steel welded mesh to be welded with the existing reinforcement. The cost of welded mesh is to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed. (b) The work is to be carried out through the authorized reps/technicians of original manufacturers and contractor will have submit all necessary documents and proofs in this regard.
M & L for Cutting / Chipping the spalled loose concrete of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Zinc rich epoxy primer to all steel surfaces as antirust agent and welding steel wire Fabric / Mesh of aperture 75mm and 2mm dia of wire to existing reinforcement, applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd as per manufacturer's instructions and providing pressure Guniting exceeding 25 mm and not exceeding 50 mm (average thickness) at a pressure of not less than 6 KG / Sqcm in CM 1:3 duly mixing the mortar with and including polycrete admixture of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 2% of weight of cement, finishing the surface rough and finally rendering with 15 mm thick in CM 1:4 and finishing the top surface even and smooth without using extra cement conforming to proper geometrics to match with the existing surface including providing double scaffolding and safety measures as required and removal of the same on completion and disposal of demolished materials / debris outside MD land complete all as specified and as directed. (Note:(a) steel welded mesh to be welded with the existing reinforcement. The cost of welded mesh is to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed. (b) The work is to be carried out through the authorized reps/technicians of original manufacturers and contractor will have submit all necessary documents and proofs in this regard.
Taking down plaster on brick or concrete surfaces including raking out joints for key and srubbing down with water etc complete all as specified and directed.
M&L for rendering 5 mm thick in CM (1:3) on ceiling sufaces, finished even & smooth without using extra cement , complete all as specified and directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick or concrete the surface even and smooth without using extra cement in CM (1:4) Mixed with water proofing compound @ 3% of weight of cement complete all as specified and directed. Note :Water proofing compound shall be measured and paid separately
Preparing new plastered surfaces of walls by using vaccume based hand held or long handle sander machine and applying Two coats of white wash by using auto roller complete all as specified and directed .
Prepration of new plastered wall surfaces by using vaccume based hand held or long handle sander machine and cleaning the surfaces by using Jet washer and applying 3 mm thick cement based wall putty by using automatic putty sprayer, (the putty shall be mixed with multipurpose mixer only) to achieve even and smooth surfaces and applying two coats of exterior weather proof (100% acryllic paint) over a coat of suitable primer by using auto roller or airless sprayer machiner over a coat of primer complete all as specified and directed
Prepration of new plastered surfaces by using vaccume based hand held or long handle sander machine and applying a layer of chalk whitning and applying two coats of oil bound distemper over a coat of suitable primer by using auto roller or airless sprayer machiner over a coat of primer complete all as specified and directed
Demolition Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for PCC 1:5:10, type E-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete as in sunken floors including demolition of old concrete complete all as specified. [Notes: Quoted rate is inclusive for (i) Demolition of WC, traps, sanitary connections and removing all debris outside defence land. (ii) Sealing the gaps / joints between WC and flooring, joints of nahani trap & connecting pipes with sealent as recommended by the manufacturer
Supply only liquid water proofing compound of approved quality complete all as specified and directed
Applying of Nitto bond or equivalent chemical from list of makes ,two coats on plastered surface as per manufacturer instructions complete all as specified and directed.
Sri Venkateswara Constructions
Sri Shiridi Sai Engineering
Sri balaji Constructions
S RAMAKRISHNA RAJU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .