Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹8.7 Cr | L1 | Accepted-AOC Being Lowest Tender |
| 2 | L2₹9.9 Cr+₹1.2 Cr (14.1%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹9.9 Cr+₹1.2 Cr (14.1%) | L2 | Rejected-Finance Higher than Lowest Tender |
| 3 | L3₹10.0 Cr+₹1.3 Cr (15.6%)Rejected-Finance | ₹10.0 Cr+₹1.3 Cr (15.6%) | L3 | Rejected-Finance Higher than Lowest Tender |
| 4 | L4₹10.4 Cr+₹1.7 Cr (20.1%)Rejected-Finance | ₹10.4 Cr+₹1.7 Cr (20.1%) | L4 | Rejected-Finance Higher than Lowest Tender |
| 5 | Konstelec Engineers Pvt. Ltd. L5₹11.6 Cr+₹2.9 Cr (34.0%)Rejected-Finance | ₹11.6 Cr+₹2.9 Cr (34.0%) | L5 | Rejected-Finance Higher than Lowest Tender |
Tender Value
₹14.5 Cr
EMD Value
₹10.5 L
Closing Date
27 Jan 2021, 6:00 pmClosed
CE KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
AUGMENTATION OF ELECTRIC SUPPLY AT BARRACKPORE MILITARY STATION
2020_MES_393515_1
89026/E8
Open Tender
Civil Works
Item Rate
540 days
GE BARRACKPORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE BARRACKPORE
₹10.5 L
Yes
23 Mar 2021
7 Nov 2020
29 Jan 2021
7 Nov 2020
27 Jan 2021
20 Jan 2021
Amount
SCHEDULE 'A' PART I (SITE CLEARENCE AND AREA DEVELOPMENT)
M&L for approved earth filling, earth obtained from outside of MD land by rough excavation not exc 1.5 m in soft/loose soil and removing excavated soil to a distance exc 5 km up to total distance 15 km and depositing where directed by Engr in Charge and levelling in layers n exc 25 cm thick and complete all as specified and directed.
M&L for hard core stone aggregates of guage not exceeding 63mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface completed all specified and as directed.
Grubbing up tree trunk (girth of tree exc 30 cm but n exc 100 cm) including cutting of trunk protion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc 50m and clearing site.
Grubbing up tree trunk (girth of tree exc 100 cm but n exc 150 cm) including cutting of trunk protion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc 50m and clearing site.
Site clearence in soft/loose soil including cleared of shrubs,vegetation,grass brush,weed,trees and saplings not exc 30 cm and complete all as specified and directed.
SCHEDULE 'A' PART II (ROAD/PATH)
Rough excavation not exc 1.5 m deep and getting out in soft/loose soil and complete all as specified and directed.
Rolling and consolidating formation surfaces in cutting with 8 to 12 tones power roller and complete all as specified and directed.
M&L for 150mm thick (compacted thickness) solling or (sub base) (in two layers and each layer of 75mm thick) with broken boulder or quarried stones including filling of interstices, forming surfaces, rolling and consolidatation to required gradient and camber with 8 to 12 tonne power roller complete all as specified and as directed. (NOTE:- rate shall be quoted for two layers & measured as one compacted layer of 150mm)
M&L for 150 mm thick (Compacted thickness in two layers and each layer of 75mm thick) WBM with granite, trap or basalt, coarse stone aggregate of of grading-2 (63mm to 40mm size) or grading-3 (50mm to20 mm sizes) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller and complete all as specified and as directed. (NOTE:- rate shall be quoted for two layers & measured as one compacted layer of 150mm)
Preparing surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc on unsurfaced WBM and complete all as specified and directed.
Preparing surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc on black top surface and complete all as specified and directed.
M&L applying evenly a priming/tack coat with paving bitumenious primer @ 05 Kg per 10 Sqm with mechanical pressure sprayer complete all as specified and directed.
M&L applying evenly a priming/tack coat with paving bitumenious primer @ 10 Kg per 10 Sqm with mechanical pressure sprayer complete all as specified and directed.
M/L for bituminous premix semi dence asphltic concrete 40 mm consolidated thickness with paving bitumen any penetration 5.5% binder content by weight of total mix laid using mechanical paver machine rolled and compacted to required camber and gradiant complete all as specified and directed.
M/L for bituminous premixed carpet, 40 mm consolidated thickness with 0.54 cum of stone chipping mixed with 29.20 kg of binder,rolled and compacted to required camber and gradiant with power roller and premixed carpet shall be laid with mechanical paver and complete all as specified and directed.
M&L for preparation of black bituminious surfaces of road as required/directed and applying thermoplastic road marking paint with an applicator machine, the material shall be laid uniformally heated mixture with a starting mechanismamt a temprature of 160 degree centigrade. the thickness of paint shall not less than 2 mm and more than 2.5 mm, the width pattern and complete all as specified and directed.
M&L moorum/Red baijri, 75 mm thickness, spread,rolled and consolidated to graident and camber required and complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B1 ussing 20 mm graded stone agg. As in kerbs/kerb stone and the like Including weathring slightly rounded or chamferd Angles and throating etc.and complete all as specified and as directed.
M&L for 60mm thick Machine pressed precast concrete interlocking paver block glossy type any shape and size with grey cement and pigment with glossy finish confirming to IS 15658-2006 of 60 mm thick M-35 grade laid over and complete all as specified and as directed.
M& L for Preparation of new cement surfaces of kerb stones over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
SCHEDULE 'A' PART III (COMPOUND WALL)
M&L RCC M-25 (Design mix) , 20 mm graded aggregates in fdns,including raft footings, foundation beams plinth beams , bases for columns etc basement slab, under-ramed piles and mass concrete complete all as specified and as directed
Used &Waste Steel Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similiar works not exc 200 mm thick (Horizontal or sloping) for fair finished surfaces and complete all as specified and directed.
Used and Waste Steel Formwork to sides of concrete fdns, footings, bases of column , raft and raft beams , sides and soffits (if any) of fdn and plinth beam and similar work verticle or to go batter for fair finished surfaces and complete all as specified and directed..
M&L RCC M-25 (Design mix), (20mm graded aggregates) in columns , pillars ,piers, posts and struts complete all as specified and as directed.
Used and Waste Steel Formwork to sides of pillars, posts, struts,piers, columns and stanchions complete all as specified and as directed.
M&L RCC M-25 (Design mix) , (20mm graded aggregates) in Beams, cantilevrs, bressummers, lintel over 1.5m span complete all as specified and as directed.
Used and Waste of steel Formwork to edge of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete wall floor and roofs exc 5 cm but not exc 10 cm wide for fair finished surfaces. And complete all as specified and directed.
S&F Rolled Mild steel in Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated) Fe-410-W (Gde-E-250) quality A, drilled and counter sink for bolting or riviting with nut for iron fillets and complete all as specified and as directed.
M&L Rendering 15mm thick cement plaster in cement mortar 1:6 on Brick/conc.Surface.and finshing even and smooth without using extra cement complete all as specified and as directed.
M& L for two coats of cement base paint over one coat of primer including Prepration of newly plastered surfaces, and complete complete all as specified and as directed.
S&F for Broken glass on top of walls and complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of zink chrome primer,including prepartion of new steel surfaces any description, over 10 cm width or girth, not otherwise described and complete all as specified and as directed.
S&F for MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering , doors etc, to be prepared for hanjing or sliding with and inc, either hooks and hinges or steel hanging door fittings (exclusine of steel sheeting or other conering , runing rails and guides) and hangings also fastening and fixing and complete all as specified and as directed.( FE 410-W, Gde-250 quality A ).
S&F Galvanised. 2 strand, steel barbed wire 2.24 mm dia, barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) and complete all as specified and as directed.
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates as in surface channel etc including weathering, slightly rounded or chamffered angle and throating including necessary form works and finished surfaces fair and even with using extra cement and complete all as specified and as directed.
SCHEDULE 'A' PART IV (AREA DRAINAGE)
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregates as in surface channel and drains and complete all as specified and as directed.
M&L for Extra for forming fair finished drain or channel 40 cm inner girth in cement concrete including formwork and using extra cement, mould mitred/stopped ends etc and complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm and complete all as specified and as directed.
M&L for providing precast cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregates) set in CM (1:6) as in slab for water tank/shelf, landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs,mangers, shelves and similar articles with plain faces complete with joints to match and all as specified and as directed.
M&L for Reinforced concrete pipe , class NP-2, laid and jointed complete with collers 200 mm bore and complete all as specified and as directed.
SCHEDULE 'A' PART V (SEWAGE DISPOSAL)
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth for foundation , etc n exc 10 Sqm on plan and n exc 1.5 m depth beyond and getting out in hard/dense soil all as specified and directed.
M&L for soil glazed stone ware drain pipes laid in tranches and jointed as specified 150 mm pipes with 150 mm thick PCC bed in D2 (1:4:8) including packing under, and haunching against the sides of pipes after laid and tested and complete all as specified and directed.
Removing of excavated material exc 250m and n exc 500m and depositing where directed at a level n exc 1.5 m above the starting point.
M&L for LLDPE Septic tanks for 10 users, fixing in any type of including connection etc vent shaft complete upflow filter including media etc, and complete all as specified in technical drawings and as directed
M&L for soakage wells of size 2.4 m dia X 3.00 m deep, excavated in ordinary soil, Fdn in PCC 1:3:6, well in honey combed and solid in PCC M-25 (Design Mix) including intercepting chamber, screen chamber, with honey comb BW in CM, RCC cover slab in M-25/RR masonry/filling with brick bats, with Cement Plaster in CM 1:4, 15 mm thick using Water Proofing Compound duly filled with clean dry sand and complete all as specified in TD and as directed as per Drg.
SCHEDULE 'A' PART VI (EXTERNAL WATER SUPPLY)
Supply and lay 3 layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial wlded having thermal stability for cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floor etc(inner antimicrobial, outer UV stabilized) ISI marked, IS-15801 PP-R pipes SDR 11 (PN-10) and PPR plain fitting in trenches/walls/ceilling or laying in floors complete of size outer dia 25 mm including all fittings and necessary accessories and complete all as specified and directed.
Supply and fixing PPR gate valve(brass insert) of outer dia 25 mm and complete all as specified and directed.
M & L for cutting of existing 40 to 50 mm bore GI pipe in position and insertion of GI tee of suitable size with union, nipple etc all as directed for provision of GI branch connection etc complete including necessary excavation and earth work, all as specified and directed.
SCHEDULE 'A' PART VII (REFG & AC)
Supply,and installed water cooler electric driven (single phase), Stainless Steel body and Tank, and using enviornment friendly refrigerant having approx storage capacity of 40 litre and nominal cooling capacity of 40 litres per hour, complete all as specified and as directed.
Suppply and Fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 volts with output voltage stabilized at 230 volts with accuracy of +/- 2.5 % and of capacity 1.0 KVA, complete all as specified and as directed.
SCHEDULE 'A' PART VIII (LIGHTING PROTECTION)
Supply and Fixing Air termination, single pointed Aluminium rod 12 mm dia and 300 mm long, single pointed at top and mounted on GI Pipe with two numbers of MS clamp of suitable size and connecting up with Aluminium strip complete with clamps and all accessories and all as specified and as directed. Note : GI Pipe and PCC Block for mounting of Air Termination Rods to be measured and paid for separately.
Supply and Fixing of Aluminium strip size 25 x 3.15 mm with saddles and fixing screws for roof conductors and down conductors above ground fixed to roof by means of stand-of hold fast placed on PCC blocks and fixed to wall / parapet on insulated saddles complete all as prescribed and all as specified and as directed. Note; Aluminium strip in roof conductors shall not be directly fixed/touching on roof surface.
Test point terminal block made of Gun metal or phosphorous bronze size 75x75x25 mm grilled & screwed including 3 Nos. of 8 mm dia 25 mm long hexagonal head brass screws complete all as specified and as directed at site .
Supply and Fixing of GI Strip 32 x 6 mm buried in ground 150 mm below normal ground level including connecting up with earth electrode plates of earthing on both ends with GI nuts, bolts & washers, in addition to welding and also including all excavation, earth work and returning filling-in, levelling, compacting, etc complete all as specified and as directed. (For extention of earthing). Note : The earthing strip shall not pass through or be enclosed/encased into any metallic pipes.
Material and labour for plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate, including necessary form work for casting of PCC Blocks for placing air termination rods/roof conductors all as specified and as directed at site.
Material and labour for galvanized steel water tubing light grade 40 mm bore for fixing up of the air termination rod including necessary clamps etc complete all as specified and as directed at site.
SCHEDULE 'A' PART IX (ELECTRIC SUPPLY)
Supply, installation, testing and commissioning of 33/11KV, 2500 KVA Outdoor Type 3 Phase, 50 Hz, with neutral grounding system, ONAN Cooled, Oil Immersed Copper Wound Step Down Power Transformer complete with first filling of IS : 335 ISI marked filtered & Dehydrated Transformer Oil and other Standard fittings/Accessories and including providing OFF load Tap Changer suitable of input voltage variation in Range : + 5 % to -15 % in steps of 1.25% each, for high voltage variation and with Vector Group DYn-11 mounted on R.C.C platform foundation as per manufacturers recommendations with following Technical Specifications and Fittings/Fixtures/Accessories as per description given here-in after :- Contd/-
TECHNICAL SPECIFICATIONS: 1. Type/Service: Outdoor. 2. KVA Rating: 2500 KVA (Copper Wound). 3. Rated Voltage HV/LV Windings: 33/11 KV. 4. Rated Frequency: 50 HZ. 5. Number of Phases: Three Phase with neutral grounding on LV side. 6. Connections HV/LV Windings: Delta/Star, Connection Symbol: DYn-11. 7. Tapping: Range- +5% to -15% in steps of 1.25% each, Number of steps-17 Nos including the principal tapping for Variation of Voltage on HV side. 8. Ambient conditions i.e. Temperatures and Humidity: as prevalent at Barrackpore near Kolkata. Design considerations for high humidity to be kept in view. 9. Type of Cooling: Oil Natural Air Natural (ONAN). 10. Maximum Temperature rise- Top Oil (By Thermometer)-50 Degree Centigrade, Windings (By Resistance) - 55 Degree centigrade. 11. Component losses : No load losses at rated voltage and frequency -Not exceeding 3400 Watts, Load Losses at rated current and principal tapping at 75 Degree C- Not exceeding 26000 Watts, Total Losses-Not exceedings-29400 Watts. 12. Percentage impedance at 75 Degree C, rated current and principal tapping- between 6.25-7.15 %. 13. Cooling: The radiators are to be detachable type with radiator valve mounted on transformer tank body. 14. Insulation Levels: Separate source power frequency voltages withstand HV Wingings-70.0 KV, LV Windings-28 KV, and Induced over voltage withstand-HV Windings- 66 KV, LV Winding- 22 KV applied across LV Terminals. Full waves Impulse withstand voltage- HV Windings-170 KVP, LV Windings-75KVP. 15. Efficiency at 75Degree C and U.P.F- at 100% full load-Not less than 98.84, at 75% of full load-not less than 99.05%, at 50% full load- not less than 99.21%. 16. Efficiency at 75Degree C and 0.8 P.F- at 100% full load-Not less than 98.55, at 75% of full load-not less than 98.81%, at 50% full load not less than 99.02%. 17. Tapping Arrangements:- Off Load Tap Changer provided on HV Windings 18. Terminal Arrangements: - Outdoor type solid porcelain bushings with horn gap on HV Side and Cable end box arrangements on LV Side. Additional neutral bushings shall also be provided. 19. Provision of Earthing (Two Independent earths for Neutral and Body each) with suitable size (As per OEMs recommendations) of Copper strips along with earthing pits shall be deemed to be included in quoted rates. 20. Reference Standards : IS:2026( Part I to IV), IS: 6600, IS:3347, IS:2099, IS;335, IS: 8468. Contd/-
FITTINGS/FIXTURE/ACESSORIES 1. NAME, RATING & DIAGRAM PLATE - 01 No 2. BODY EARTHING TERMINALS- 02 Nos. 3. OFF CIRCUIT TAP CHANGING SWITCH 4. LIFTING LUGS- 2 Nos. 5. OIL LEVEL INDICATOR (FLUSH TUBE) - 1No. 6. OIL DRAIN VALVE WITH PLUG-1 No. 7. OIL FILTER VALVE WITH PLUG -1 No. 8. CONSERVATOR WITH OIL FILLING HOLE-1 No. 9. THERMOMETER POCKET-1 No. 10. 4” DIAL TYPE THERMOMETER STEM TYPE -1 No. 11. .AIR RELEASE PLUG- 1 No. 12. SILICAGEL BREATHER- 1 No. 13. REMOVABLE INSPECTION OPENING - 01 NO 14. EXPLOSION VENT - 1 No. 15. BIDIRECTIONAL C.I. ROLLERS - 4 Nos. 16. ARCHING HORN SET (Only for HV Bare Bushing Type Transformer)-3 Nos 17. BUCHHOLZ RELAY (Double Float Type) (Having Contacts for Alarm & Trip) 01 No 18. OIL TEMPERATURE INDICATOR – 6” DIAL TYPE - 01 No (Having Contacts for Alarm & Trip) 19. WINDING TEMPERATURE INDICATOR - 01 No (Having Contacts for Alarm & Trip) 20. MARSHALLING BOX - 01 No (Having TTB, Heater, Lamp, Door Switch & MCB) 21. MAGNETIC OIL LEVEL GAUAGE (Having Contacts for Alarm or Trip) - 01 No 22. PRESSURE RELIEF VALUE (PRV) (Having Contacts for Alarm or Trip) - 01 No 23. User/Maint manual and Test certificates etc. (Note Cost of RCC foundation for Power Transformer according to transformer size as per OEM recommendations shall be deemed to be included in the unit rate. The platform shall have adequate space all around for a man to comfortably stand for carrying out repairs and maintenance. )
Supply, install, testing and commissioning of 33/0.433 KV Outdoor Type 3 Phase, 50 Hz, ONAN Cooled Oil Immersed Copper Wound Outdoor Type Step Down Power/Distribution Transformer for Substation lighting complete with first filling of IS : 335 ISI marked filtered & Dehydrated Transformer Oil and other Standard fittings/Accessories including providing Off Circuit Tap Changer with range + 2.5%, +5% & +7.5% and 7 position and including the Principle Tapping for High Voltage Variation, mounted Two Steel Tubular pole Structure as per manufacturers recommendation with following Technical Specifications and Fittings/Fixtures/Accessories as per description below :-- Contd/-
TECHNICAL SPECIFICATIONS: 1. Type/Service: Outdoor Pole Mounted. 2. KVA Rating: 100 KVA (Copper Wound). 3. Rated Voltage HV/LV Windings: 33/0.433 KV. 4. Rated Frequency: 50 HZ. 5. Number of Phases: Three Phase with neutral grounding on LV side. 6. Connections HV/LV Windings: Delta/Star, Connection Symbol: DYn-11. 7. Tapings: Range- +/- 2.5%, +/- 5%, +/-7.5%, Number of steps-7 Nos including the principal tapings for Variation of Voltage on HV side. 8. Ambient condition Temperatures and Humidity: as prevalent at Barrackpore near Kolkata. Design considerations for high humidity to be kept in view. 9. Type of Cooling: Oil Natural Air Natural (ONAN). 10. Maximum Temperature rise- Top Oil (By Thermometer)-35 Degree Centigrade, Windings (By Resistance) - 40 Degree centigrade. 11. Component losses : No load losses at rated voltage and frequency -Not exceeding 240 Watts, Load Losses at rated current and principal tapings at 75 Degree C- Not exceeding 1100 Watts, 12. Percentage impedance at 75 Degree C, rated current and principal tapping- between 4-5 %. 13. Cooling: The radiators are directly mounted on transformer tank body. . 14. Insulation Levels: Separate source power frequency voltage withstands, HV Wingings-70.0 KV, LV Windings-3 KV, and Induced over voltage withstand-HV Windings- 66 KV, LV Winding- 866 Volts applied across LV Terminals. Full wave Impulse withstands voltage- HV Windings-170 KVP, LV Windings-N.A. 15. Efficiency at 75Degree C and U.P.F- at 100% full load-Not less than 98.70, at 75% of full load-not less than 98.80%, at 50% full load not less than 98.95%. 16. Efficiency at 75Degree C and 0.8 P.F- at 100% full load-Not less than 98.36, at 75% of full load-not less than 98.60%, at 50% full load not less than 98.75%. 17. Tapping Arrangements: - Off Load Tap Changer provided on HV Windings, hand operated. 18. Terminal Arrangements: - Outdoor type solid porcelain bushings on HV Side and Cable end box arrangements on LV Side. Additional neutral bushings shall also be provided. 19. Provision of Earthing (Two Independent earths for Neutral and Body each) with suitable size (As per OEMs recommendations) of Copper strips along with earthing pits shall be deemed to be included in quoted rates. 20. Reference Standards : IS:2026( Part I to IV), IS: 6600, IS:3347, IS:2099, IS;335, IS: 8468. Contd/-
FITTINGS/FIXTURE/ACESSORIES 1. NAME, RATING & DIAGRAM PLATE - 01 No. 2. EARTHING TERMINALS- 02 Nos. 3. LIFTING LUGS- 02 Nos. 4. OIL LEVEL INDICATOR (FLUSH TUBE) - 01No. 5. OIL DRAIN VALVE WITH PLUG - 01 No. 6. OIL FILTER VALVE WITH PLUG (on & above 160 KVA) - 01 No. 7. CONSERVATOR WITH OIL FILLING HOLE - 01 No. 8. THERMOMETER POCKET - 01 No. 9. 4” DIAL TYPE THERMOMETER STEM TYPE & WITH -1 No. 10. AIR RELEASE PLUG- 01 No. 11. SILICAGEL BREATHER- 01 No. 12. REMOVABLE INSPECTION OPENING - 01 NO. 13. EXPLOSION VENT - 1 No. 14. UNIDIRECTIONAL C.I. ROLLERS - 04 Nos. 15. ARCHING HORN SET (Only for HV Bare Bushing Type Transformer) - 03 Nos. 16. Off circuit tap switch, provided on the HV winding, three phases, externally, hand operated, having tap position marking on the dial and capable to be locked in any particular tap position. 17. OIL DRAIN CUM FILTERING VALVE WITH PLUG- 1 No. 18. OIL FILLING CUM FILTERING VALVE WITH PLUG- 1 No. 19. SILICAGEL BREATHER -01 No. 20. User/Maint manual and Test certificates etc. (Note: - Steel Tubular Poles, Steel work for platform, GOD, DO, and LA and its Earthings to be measured and paid for separately. All other items as required are deemed to be included in the unit rate)
Supply, installation, connecting, testing and commissioning of 11 KV Compact Sub Station (CSS) with extensible RMU consisting of 1 No manually operated 11 KV/630 Amps VCB (as incomer) and 2 Nos. Fixed Manual Load Break Switch (as Outgoings) in SF6 insulated stainless steel enclosure, suitable rating HT Cable, Bus bar, Transformer 500 KVA - 01 No,11KV/433 CRT dry type & associated HT/LT devices complete fitted on RCC. Foundation as per manufacturer recommendation. Note: CSS shall be installed/erected on RCC base as per OEM recommendations and including cable incoming and outgoing ducts in RCC basement as per site requirement. RCC base work should be 2 feet from above GL with necessary steps and cattle fencing up to 1.5 meter height all around up to 4 meter width from the CSS side to fence and suitable MS Gate and locking arrangement as directed and specified. Cost of RCC foundation, cattle fencing, MS Gate and other allied material shall be deemed to be included in the unit rate. The 11 KV Outdoor Package Sub-Station shall be consisting of following :- Contd/-
A. HT SWITCHGEAR :- i. 11kV, 630Amps, 21KA/3 sec. Extensible Ring Main Unit Compact switchgear consisting of Two numbers Fixed Manual Load Break Switch and One no Fixed Manual Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 150 sq.mm Aluminium Unarmoured XLPE cable and including providing necessary functioning connected all accessories.-01 No. ii. Numerical Self Powered Communicable Relay of RS 485 Port (50, 50N, 51,51N) -01 No. iii. Protection CT shall be 50/1A 2.5VA 5P10.-01 set iv. Manometer -01 No. B. TRANSFORMER :- i. 500 KVA 11KV/433V DYn11 Copper Wounded Cast Resin Dry Type Transformer, Class F Insulation, Temp Rise 90 Deg Centigrade over an ambient of 50 Deg C, Transformer tappings +5% to -5% @2.5% per step, % Impedance: 4.5%(Approx).- 01 No. ii. Winding Temperature Indicator with Alarm and Trip Contact - 01 No. C. LVS PANEL- 800AMPS ALUMINIUM BUSBAR (FOR PHASE 100% AND NEUTRAL 50%):- INCOMER FROM TRANSFORMER i. 800AMPS 415V 4P 50 KA Manual Draw out Type (MDO) type Air Circuit Breaker (ACB) with Microprocessor Based over current, short circuit & Earth Fault release. 01 No. ii. LED Type Indicating Lamps- R,Y,B Phase Contact - 01 Set. OUTGOINGS i. 315A, 433V, 4P, 50kA, MCCB with microprocessor based release. 05 No. ii. ON-OFF-TRIP LED Lamps Contact - 05 Sets. Contd/-
A. OUTDOOR ENCLOSURE :- i. Outdoor type enclosure having construction of Galvanized Sheet Steel of thickness 2 mm for Load bearing member and 1.5 mm for Non Load bearing member with 4 mm HRCA Base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (Colour Light Gray & D.A.Gray). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV and LV compartment. Separate switch operated bulkhead lamp with hooter in transformer compartment. 01 Set. B. INTERCONNECTION AND EARTHING:- Interconnection between HT switchgear & Transformer using 1Cx3x150 Sq.mm Al. unarmorured XLPE Cable. & Interconnection between Transformer & LT switchgear using Aluminium Busbars. Internal earthing connections by using 50X6 mm GI Flat including Transformer Neutral. 01 Set.
Supply, installation, connecting, testing and commissioning of 11 KV Compact Sub Station consisting of 1 No manually operated 11 KV/630 Amps VCB in SF6 insulated stainless enclosure, HT Cable/Bus bar ,1 No transformer 250KVA,11KV/433 CRT dry type & associated LT devices complete fitted on RCC. Foundation as per manufacturer recommendation. :- Note: CSS shall be installed/erected on RCC base as per OEM and including cable incoming and outgoing ducts in RCC base as per site requirement. RCC base work should be 2 feet from above GL with necessary steps and cattle fencing up to 1.5 meter height all around up to 4 meter width from the CSS side to fence and suitable MS Gate and locking arrangement as directed and specified. Cost of RCC foundation, cattle fencing, MS Gate and other allied material shall be deemed to be included in the unit rate. The Outdoor Package Sub-Station shall be consisting of following :- Contd/-
A. HT SWITCHGEAR i. 11 KV, 630 A,( 21 KA for 3 Sec) Compact switch gear consisting of one fixed manual vacuum circuit breaker in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. Interconnection between HT switchgear and primary of transformer should be through 1C, 95 sq mm aluminium, armoured XLPE cable and including providing necessary functioning connected all accessories.:- 01 No. ii. Numerical Self Powered Communicable Relay of RS 485 Port (50, 50N, 51,51N):- 01 No. iii. CT of ratio 40/1A, CL - 5P10, Burden - 2.5VA for protection. : - 03 No. iv. Manometer: - 01 No. B. TRANSFORMER. i. 250KVA 11KV/433V DYn11, Cast Resin Dry Type Transformer, Class F Insulation, AN Cooling, IP-00 Class Transformer, Off Circuit Tap Links +5% to -5% @2.5% per step, % Impedance: 5%..:- 01 No. ii. Winding Temperature Indicator with alarm and trip contact: - 01 No. C. LVS PANEL - 630AMPS ALUMINUM BUSBAR ( 100% for Phase & 50% Neutral , Current density- 1amp/sq mm):- INCOMER FROM TRANSFORMER i. 630 Amps 433V 50KA 4P Manually Fixed Type MCCB type Moulded Case Circuit Breaker (MCCB) microprocessor based over current, short circuit and Earth fault protection-. 01 No. ii. RYB, ON-OFF-TRIP Indication - 01 Set. OUTGOINGS i. 100A, 433V, 4P, 50kA, MCCB with microprocessor based release. 03 No. ii. ON-OFF-TRIP LED Lamps - 03 Sets. Contd/-
D. OUTDOOR ENCLOSURE :- i. Outdoor type enclosure having construction of Galvanized Sheet Steel of thickness 2mm for Load Bearing Member and 1.5mm for Non Load Bearing Member with 4mm HRCA base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure shall be Powder Coated (Colour Light Gray & D.A.Gray). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Separate Switch Operated Bulked lamp with hooter in Transformer compartment. 01 Set. E. INTERCONNECTION AND EARTHING:- Interconnection Between HT switchgear & Transformer using 1Cx3x95 Sq.mm XLPE Single core cable & Interconnection between Transformer & LT switchgear using AL. Busbars. Internal earthing connections by using 50 x 6mm GI strips including Transformer Neutral. 01 Set.
Supply, installation, connecting, testing and commissioning of HT 33 KV 3 phase 50 cycles totally enclosed metal clad SF 6 switchgear outdoor type water proof, weather proof overload & earth fault protection , ammeter , voltmeter with following specifications:- Type :- Outdoor, Reference Standard - IEC 62271-100.Rated Voltage - 33kV, Maximum Rated Service Voltage- 36KV, Normal Current Rating- 1250 A, Frequency- 50 Hz, Short Time Current Rating 25kA for 3sec, Breaking Capacity -25kA,Making Capacity -62.5kA peak, Maximum Temperature rise over ambient Within limits as per EC 62271-100, Dry 1 minute power frequency withstand :- (a) Between line terminal and grounded objects - 70KV rms. (b) Between terminals with breaker contacts open- 70KV rms. Dry 1.2/50 minute power frequency with stand (a) Between line terminals and grounded objects - 170KV peak. (b) Between terminals with breaker contacts open- 170KV peak. Rating of the circuit breaker capacitor switching -400A Opening Time-45 (+15/-10) ms Closing Time -65 (±15) ms Total Creep age distance - 900mm, Number of poles of circuit breaker - 03 (a)Those closed when breaker is closed-4 (b) Those open when breaker is closed - 4 Type of operating mechanism - spring operated mechanism Control circuit voltage-30VDC (a) Operating voltage of tripping coil - 70% to 110% of the Control voltage (b) Operating voltage of closing coil - 85% to 110% of the Control voltage Voltage of spring charging Motor - 230V AC Time required for motor to charge the spring fully-15 sec (Max)
Supply, install, test and commissioning of 11 KV 400 Amp 26.3KA 15 panel VCB (consisting of VCB's three numbers incoming, two bus coupler and 8 outgoing and two Nos bus riser ) totally enclosed metal clad suitable for 11 KV, 3 phase, 50 Hz electric supply with vacuum circuit breaker (VCB) indoor draw out type, vertical isolation, with integral earthing facility complete with all necessary CTs, PT, and relay and battery bank complete with all connection arrangements with following items of descriptions :- Contd/-
Uni Gear Type - Single Bus bar, Delivery version - Complete Panels, Standard - IEC 62271-200, FAT - Standard FAT, Altitude of Installation - Less than 1000m, Rated Voltage - 12KV, Service Voltage - 11KV, Rated frequency - 50 Hz, Power Frequency withstand voltage at altitude <= 1000m - 28kV rms, BIL at altitude <=1000m-75kv peak, Short time withstand current-26.3 kA rms - 1s, Peak withstand current - 65.75kA peak, Internal arc withstand current - 25 kA rms-1s, Bus bar rated current - 400A, Loss of service continuity- LSC 2B, Internal arc classified- IAC A FLR, Portion Class - PM, Protection degree outer cover (IEC 60529)- IP4X, Protection degree inner partitions (IEC 60529)-IP2X, Ambient Temperature (IEC 60694)- -5 to +40 Degree C, Painting colour - RAL 7032, Painting Treatment - Standard, Gas duct - Standard gas duct with Chimneys, Feeder and apparatus doors closing version - Central Handle, LV compartment closing doors version - Screws, Floor fixing - Anchoring bolts, Ant condensation heater - In cable compartment in apparatus compartment, LV compartment internal lighting- Provided with limit switch, Apparatus spring loading voltage - 230V AC 50Hz, Control auxiliary Voltage - 110DC, Lighting & heating voltage - 230V AC 50Hz, Control circuits wires section -1.5 Sqmm, Voltage Circuits wires section - 1.5 Sqmm, Current circuits wires section -2.5 Sqmm, Earthing circuits wires section - 4 Sq mm, Wiring cable rated voltage - Standard, Wiring Cable type - Standard, Wiring Cable rated Voltage - 1.1 kv, Wiring cables colour - As per IEC standard rule, Colour of Auxiliary AC -Black, Colour of Auxiliary DC - Grey, Colour of CT Circuits-R-Y-B-Black, Colour of VT Circuits - R-Y-B-Black, Communication protocol-Serial MODBUS single, Communication connection media - Metallic Contd/-
11KV, 25 KA, 400A Indoor VCB 2 Panel Board. It comprises of 11KV 26.3KA, 400A Indoor VCB Incoming Panel - 03 Nos, 11 KV, 26.3KA, 400 Indoor VCB Bus Coupler Panel - 02 Nos, 11 KV Bus Riser - 02 Nos, 11 KV 26.3KA, 400A Indoor VCB Outgoing Panel - 08 Nos and each panel should consist of the following items and quantities shown against each all as specified and directed :- Contd/-
11 KV, 26.3KA, 400A Indoor VCB Incoming Panel - 03 No’s This panel should consist of the following specification of each items and quantities shown against each all as specified and directed :- a. Bulbar Current - 400A, b. Rated Voltage - 12KV, c. Rated Current - 400A, d. Short Circuit Current - 25KA, e. Auxiliary Contacts, Spring Charging motor voltage - 230V AC 50 Hz, f. Trip Coil Motor Voltage - 110DC, g. Control coil control voltage - 110VDC, h. Incomer - 01 No i. Copper Bus bars - 400A, j. Vacuum Circuit Breaker 12 kV, 400A, 25 kA as per IEC 62271-100-200 - 01 No, k. Current Transformer - 150-50/1+1A, Core 1:1.0/5VA, Core 2:5P10/5VA- 03 Nos, l. Voltage Transformer - 11kV/v3/110V/110V/V3 Core 1:0.5/50VA, Core 2:3P/50VA-Core-1 - 03 Nos, m. Additional Articles : Protection relays (50, 50N, 51, 51N, 68, 86, 95). without Communication 4/6 DI/DO - 01 No, n. Pluggable Auxiliary relays Pluggable Antidumping Relay with Base - 110VDC - 01 No, o. Auxiliary Relay: Master Trip Relay DC Aux - Part of Numerical Relay. p. Instrument Digital Ammeter with built in SS - 01, Digital Voltmeter with built in SS - 01 No, Digital Voltmeter with built in SS - 01 No, Digital MFM type: - 01 No, q. Miscellaneous. TNS Switch - 01 No, Local/Remote Switch - 01 No, LED Indicating Lamp. (Other Color) - 11 Nos, MCB for Panel AC - 02 No. MCB for Panel DC - 02 Nos. MCB for spring charging AC - 01 No. MCB for PT secondary - 1A - 01 No’ Power Pack (I/P : 230V AC O/P V DC) - 01 No Contd/-
11 KV, 26.3KA, 400A Indoor VCB Bus coupler Panel - 02 Nos This panel should consist of the following specification of each items and quantities shown against each all as specified and directed :- (a) Bus bar Current - 400A, (b) Rated Voltage - 12KV, (c) Rated Current - 400A, (d) Short Circuit Current - 25KA, (e) Auxiliary Contacts, Spring Charging motor voltage - 230V AC 50 Hz, (f) Trip Coil Motor Voltage - 110DC, (g) Control coil control voltage - 110VDC, (h) Bus coupler - 01 No (I) Copper Bus bars - 400A, (j) Vacuum Circuit Breaker 12 kV, 400A, 25 kA as per IEC 62271-100-200 - 01 No, (k) Current Transformer - 150-50/1+1A, Core 1:1.0/5VA, Core 2:5P10/5VA- 03 Nos, (l) Additional Articles : Protection relays (50, 50N, 51, 51N, 68,86,95) without Communication 4/6 DI/DO - 01 No, (m) Pluggable Auxiliary relays Pluggable Antipumping Relay Type CRM 4 with Base - 110VDC - 01 No, (n) Auxiliary Relay: Master Trip Relay Type PQ8 (86) DC Aux - Part of Numerical Relay. (o) Instrument Digital Ammeter with built in SS - 01, Digital MFM type: Elite 443 - 01 No, (p) Miscellaneous. TNS Switch - 01 No, Local/Remote Switch - 01 No, LED Indicating Lamp (Other Color) - 8 Nos, MCB for Panel AC - 02 Nos MCB for Panel DC - 02 Nos MCB for spring charging AC - 01 No, MCB for Main AC - 01 No MCB for Main DC - 01 No Power Pack (I/P : 230V AC O/P V DC) - 01 No Contd/-
11 KV, BUS RISER - 02 Nos This panel should consist of the following specification of each items and quantities shown against each all as specified and directed :- (a) Rated Current - 400A, (b) Short Circuit Current - 25KA, (c) Auxiliary Contacts, Spring Charging motor voltage - 230V AC 50 Hz, (d) Trip Coil Motor Voltage - 110DC, (e) Control coil control voltage - 110VDC, (f) Bus Riser - 01 No (g) Copper Bus bars - 400A, (h) Miscellaneous. MCB for Panel AC - 02 Nos MCB for Panel DC - 02 Nos Contd/-
11 KV, 26.3KA, 400A Indoor VCB Outgoing Panel - 08 Nos This panel should consist of the following specification of each items and quantities shown against each all as specified and directed :- (a) Bus bar Current - 400A, (b) Rated Voltage - 12KV, (c) Rated Current - 400A, (d) Short Circuit Current - 25KA, (e) Auxiliary Contacts, Spring Charging motor voltage - 230V AC 50 Hz, (f) Trip Coil Motor Voltage - 110DC, (g) Control coil control voltage - 110VDC, (h) Copper Busbars - 400A, (I) Vacuum Circuit Breaker 12 kV, 400A, 25 kA as per IEC 62271-100-200 - 01 No, (j) Current Transformer - 150-50/1+1A, Core 1:1.0/5VA, Core 2:5P10/5VA- 03 Nos, (k) Additional Articles : Protection relays (50, 50N, 51, 51N, 68,86,95) without Communication 4/6 DI/DO - 01 No, (l) Pluggable Auxiliary relays Pluggable Antipumping Relay Type CRM 4 with Base - 110VDC - 01 No, (m) Auxiliary Relay: Master Trip Relay Type PQ8 (86) DC Aux - Part of Numerical Relay. (n) Instrument Digital Ammeter with built in SS - 01, Digital MFM type: Elite 443 - 01 No, (o) Miscellaneous. TNS Switch - 01 No, Local/Remote Switch - 01 No, LED Indicating Lamp (Other Color) - 8 Nos, MCB for Panel AC - 02 Nos MCB for Panel DC - 02 Nos MCB for spring charging AC - 01 No, Power Pack (I/P : 230V AC O/P V DC) - 01 No
Supply, install, test and commissioning of RMU 03 way (consisting of VCB's two numbers as incoming, and 01 No outgoing) totally enclosed metal clad suitable for 33 KV, 3 phase, 50 Hz, indoor draw out type, vertical isolation, with integral earthing facility complete with rupturing capacity 350 MVA of rating 630 amps. With necessary CTs, PT and relays and metering panel with all connection arrangements all as specified and directed. Contd/-
STANDARDS AND MECHANICAL DATA Metal Enclosed switchgear: IEC 62271-200 General Purpose switches: IEC 60265-1 Disconnectors and Earthing switches: IEC 62271-102 Switch Fuse Combination: IEC 62271-105 Common clauses: IEC 60694 Pressure of SF6 gas: 1.4 bar at 20 °C Cable bushings outside cone: interface C Temperature class: -25 °C - +40 °C Outdoor Degree of protection: - SF6 tank: IP 67 - Outdoor Enclosure IP 54 - Front cover: IP 2X - Cable cover: IP 3X Busbars: 306 mm2 Cu Earth bar (external): 120 mm2 Cu - Bolt dimension: M10 Thickness of Stainless Steel Tank: 2.0 mm Colours: - Front cover: RAL 7035 - Side and cable cover: RAL 703 Contd/-
ELECTRICAL DATA – 36 kV Nominal voltage: 33 kV Rated frequency: 50 Hz Rated current for busbars: 630 A Rated current for cable switch disconnector: 630 A Short time withstand current (1 sec) cable switch disconnector: 25 kArms Rated current for transformer T-off: 630 A Short time withstand current (1 sec) V-module vacuum circuit breaker: 25kArms Impulse withstand voltage: To earth and between phases: 170 kV Insulation level: - Power frequency 1 min: 70 kV Contd/-
Vacuum circuit breaker module with vacuum circuit breaker, stored energy spring mechanism for O - 0,3 s - CO – 15 s - CO operating sequence, two-position operating mechanism for the isolator and earthing switch, busbars , interlocking and earth bar. Vacuum circuit breaker 36kV, 630A, 20kA - 01 No Cable compartment standard - 01 No Cable bushings interface C (400 bolted), 630 A, standard - 01 No Manometer - 01 No Single cable connection - 01 No Capacitive voltage indication fixed type VPIS - 01 No Stored energy mech. for manual operation - 01 No Additional sidewall right side - 01 No Protection relay type with display - 01 No Aux. switch for vacuum circuit breaker position 2NO + 2NC - 01 No Aux. switch for disconnected position 2NO + 2NC - 01 No Aux. switch for earth switch position 2NO + 2NC - 01 No Low voltage compartment - 01 No Cable support bars, standard for 1-way unit - 01 No Ring core current transformer type 80/1, 2.5VA, Class 5P10 for protection- 03 Nos Ring core current transformer type 80/1, 2.5VA, Class 1.0 for metering - 03 Nos Digital Ammeter with S/S - 01 No Contd/-
Vacuum circuit breaker module with vacuum circuit breaker, stored energy spring mechanism for O - 0,3 s - CO – 15 s - CO operating sequence, two-position operating mechanism for the isolator and earthing switch, busbars , interlocking and earthbar. Vacuum circuit breaker 36kV, 630A, 20kA - 01 No Cable compartment standard - 01 No Cable bushings interface C (400 bolted), 630 A, standard - 01 No Manometer - 01 No Single cable connection - 01 No Capacitive voltage indication fixed type VPIS - 01 No Stored energy mech. for manual operation - 01 No Additional sidewall right side - 01 No Protection relay with display - 01 No Aux. switch for vacuum circuit breaker position 2NO + 2NC - 01 No Aux. switch for disconnected position 2NO + 2NC - 01 No Aux. switch for earth switch position 2NO + 2NC - 01 No Low voltage compartment - 01 No Cable support bars, standard for 1-way unit - 01 No Ring core current transformer type 80/1, 2.5VA, Class 5P10 for protection- 03 Nos Ring core current transformer type 80/1, 2.5VA, Class 1.0 for metering - 03 Nos Digital Ammeter with S/S - 01 No ON-OFF-TRIP LED indication Contd/-
Vacuum circuit breaker module with vacuum circuit breaker, stored energy spring mechanism for O - 0,3 s - CO – 15 s - CO operating sequence, two-position operating mechanism for the isolator and earthing switch, busbars , interlocking and earthbar. Vacuum circuit breaker 36kV, 630A, 20kA - 01 No Cable compartment standard - 01 No Cable bushings interface C (400 bolted), 630 A, standard - 01 No Manometer - 01 No Single cable connection - 01 No Capacitive voltage indication fixed type VPIS - 01 No Stored energy mech. for manual operation - 01 No Additional sidewall right side - 01 No Protection relay with display - 01 No Aux. switch for vacuum circuit breaker position 2NO + 2NC - 01 No Aux. switch for disconnected position 2NO + 2NC - 01 No Aux. switch for earth switch position 2NO + 2NC - 01 No Low voltage compartment - 01 No Cable support bars, standard for 1-way unit - 01 No Ring core current transformer type 80/1, 2.5VA, Class 5P10 for protection- 03 Nos Ring core current transformer type 80/1, 2.5VA, Class 1.0 for metering - 03 Nos Digital Ammeter with S/S - 01 No ON-OFF-TRIP LED indication Contd/-
Metering Module M is an air insulated metering module. M: Air insulated metering module 36kV, 630A- 1 No Potential transformers with HT fuse on primary side and MCB on secondary side for protection- 3 Nos Primary voltage: 33000:V3 V-01 No Secondary voltage: 110:V3 V- 01 No Burden winding 1: 25 VA- 01 No Class winding 1: 0.5- 01 No Digital Multifunction Meter with acc 1.0- 01 No Space Heater with Thermostat - 01 No Operating handle-01 No 24VDC, 12Ah batteries;230VAC charger input shall also be inclusive n scope.- 01 No NOTE FOR ITEM NO. 9.22 to 9.28 HERE IN BEFORE: This item is required to be executed as per specifications and under supervision of WBSEDCL authorities. Contractor shall submit detailed specifications, and dimensional General arrangement drawings from OEM. The specification and drawing shall be got approved from WBSEDCL before execution.
Supply and install HT 33 KV , 3-Phase outdoor type drop out fuse assembly, ISI Marked, CPRI tested, factory assembled on a hot dip galvanized steel cross arm suitable for mounting on steel poles, along with mounting brackets, with all contacts in ETP grade Copper and silver plated, All terminals in Brass-duly plated for connection with Copper or Aluminium Conductors, with Fuse tube holders having an outer layer of fiber glass and inner layer of bone liner, for effective extinguishing of arc, and with outer layers of fuse tube having a layer of UV resistant paint, easily replaceable fuse carrier tubes, the hinged mechanism made of brass duly electroplated, the spring loaded stainless steel flipper arranged toggle mechanism ensuring a wiping action during arc interruption process, with a safety latch to prevent fuse carrier from dropping due to vibration, Rated Voltage-33 KV, Rated Continuous current-100 Amps, No of Poles-3 Nos., Rated frequency-50Hz, Maximum normal current of fuse base-200 Amps, Maximum normal current of fuse holder-100 Amps, Power frequency withstand voltage across the isolating distance-70KVrms, Power frequency withstand voltage to Earth and between poles-70KVrms, Lightning Voltage withstand test across isolating distance-170KV Peak, Lightning voltage withstand test across phase to earth-170 KV, Breaking Current at 36 KV -4 KA, Earth Stirp 16 KA, along with bird cap complete with one fixed and one spare set of fuses.
Supply and erecting of a single piece non linear resistor type lightening arrestor gapless metal oxide (ZnO) suitable for 3 wire 33 KV overhead lines with rated voltage of 30 KV (rms) 10 KA discharge current with a (station class) with facility to record number of surge and complete with galvanized clamping arrangements clamp, bolt, nuts washers etc as required.
Supply and install HT 33 KV , 3-Phase outdoor gang operated air break switch(Isolator), ISI Marked, CPRI tested, factory assembled, mechanically operated , mounted on insulators and steel frame suitable for 2-Pole, Horizontal mounting fixed type complete with nine numbers of porcelain insulators( Three post insulators per pole) with Earthed Switch with post insulators , with bottom MS channel of adequate dimensions and strength, self lubricating central bush bearing , copper contacts made of ETP grade high conductivity copper and spring loaded for adequate contact pressure, duly plated to improve resistance to corrosion, All MS plate and hardware to be duly hot dip galvanized, with tin plated copper wire of adequate cross sections , operating mechanism through an insulated operating mechanism worked from ground level and mechanical locking facility, Rated Voltage-33 KV, Highest System Voltage-36 KV, Rated Continuous current-200 Amps, No of Poles-3 Nos., Rated frequency-50Hz, Power frequency withstand voltage across the isolating distance-80 KVrms, Power frequency withstand voltage to Earth-70KVrms, Lightning Voltage withstand test across isolating distance-170KV Peak, Lightning voltage withstand test across phase to earth-195 KVpeak, complete all as specified.
Supply installation testing and commissioning of single phase dry type outdoor type dual core dual ratio current transformer for main incomer as well as transformer protection suitable for 33 KV , Single Phase, 50 HZ and 15 VA Burden with fault level of 25 KA for 3 seconds and creep age 31.0 mm/kv conforming to relevant IS and all as specified and directed by Engineer in charge. (i) Core 1: 100-50/1 or 5, Accuracy Class 5 P 10, (ii) Core 2: 100-50/1 or 5 , Accuracy class 0.5, 15 VA
Supply installation testing and commissioning of type potential transformer with outdoor type dry type fault level of 25 KA for 3 seconds and creep age 31.0 mm/kv conforming relevant IS. (i) Winding 1 : 33KV/√3 : 110V/√3, 0.2 Class 100 VA & Winding 2 : 33KV/√3 : 110v/√3, 0.2 Class 100 VA
Supply and install HT 11 KV , 3-Phase outdoor gang operated air break switch(Isolator), ISI Marked, CPRI tested, factory assembled, mechanically operated , mounted on insulators and steel frame suitable for 2-Pole, Horizontal mounting fixed type complete with Earthed Switch with Post Insulator , nine numbers of porcelain insulators( Three post insulators per pole) with bottom MS channel of adequate dimensions and strength, self lubricating central bush bearing , copper contacts made of ETP grade high conductivity copper and spring loaded for adequate contact pressure, duly plated to improve resistance to corrosion, All MS plate and hardware to be duly hot dip galvanized, with tin plated copper wire of adequate cross sections , operating mechanism through an insulated operating mechanism worked from ground level and mechanical locking facility, Rated Voltage-12 KV, Rated Continuous current-200 Amps, No of Poles-3 Nos., Rated frequency-50Hz, Power frequency withstand voltage across the isolating distance-32KV, Power frequency withstand voltage to Earth-28KV, Lightning Voltage withstand test across isolating distance-85KV Peak, Lightning voltage withstand test across phase to earth-75 KV, Rated short time & Peak withstand current-20KA, complete all as specified.
Supply and install HT 11 KV , 3-Phase outdoor type drop out fuse assembly, ISI Marked, CPRI tested, factory assembled on a hot dip galvanized steel cross arm suitable for mounting on steel poles, along with mounting brackets, with all contacts in ETP grade Copper and silver plated, All terminals in Brass-duly plated for connection with Copper or Aluminium Conductors, with Fuse tube holders having an outer layer of fiber glass and inner layer of bone liner, for effective extinguishing of arc, and with outer layers of fuse tube having a layer of UV resistant paint, easily replaceable fuse carrier tubes, the hinged mechanism made of brass duly electroplated, the spring loaded stainless steel flipper arranged toggle mechanism ensuring a wiping action during arc interruption process, with a safety latch to prevent fuse carrier from dropping due to vibration, Rated Voltage-12 KV, Rated Continuous current-100 Amps, No of Poles-3 Nos., Rated frequency-50Hz, Maximum normal current of fuse base-200 Amps, Maximum normal current of fuse holder-100 Amps, Power frequency withstand voltage across the isolating distance-32KV, Power frequency withstand voltage to Earth and between poles-28KV, Lightning Voltage withstand test across isolating distance-85KV Peak, Lightning voltage withstand test across phase to earth-75 KV, Breaking Current at 15 KV -8 KA, Mounting Angle to vertical Axis -20 Degree, Total Creep age Distance 320 mm, Protected creep age distance 84 mm, complete along with two set of drop out Fuses of 20 Amps current capacity all as specified.
Supply and lay of high voltage insulation mat of size 2mx1mx3mm thick mase of elastomeric polymers class "C" suitable for system voltage 1 1 KV to 33 KV, breakdown voltage 45 KV, IS-5424" all as specified.
Electric rubber hand gloves, ISI Marked 11 KV all as specified and directed.
Electric rubber hand gloves, ISI Marked 33 KV all as specified and directed.
Supply, laying & testing HT Cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminum Conductor, 11000 volts grade cross sectional area of size 95 Sq mm 3 Core Complete all as specified and directed.
Supply, laying & testing HT Cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminum Conductor, 11000 volts grade cross sectional area of size 120 Sq mm 3 Core Complete all as specified and directed.
Supply, laying & testing HT Cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminum Conductor, 11000 volts grade cross sectional area of size 185 Sq mm 3 Core Complete all as specified and directed.
Supply, laying & testing HT Cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminum Conductor, 33000 volts grade cross sectional area of size 240 Sq mm 3 Core Complete all as specified and directed.
Supply and laying PVC insulated PVC sheathed galvanised steel strip or wire armoured , electric control cables ( heavy duty )with stranded copper conductor of size 2.5 sqmm 2 Core 1100 volts grade all as specified and directed.
Supply and laying PVC insulated PVC sheathed galvanised steel strip or wire armoured , electric control cables ( heavy duty )with stranded copper conductor of size 4 Core 2.5 sqmm 1100 volts grade Control Cables all as specified and directed.
Supply and laying PVC insulated PVC sheathed galvanised steel strip or wire armoured , electric control cables ( heavy duty )with stranded copper conductor of size 8 Core 1.5 sqmm 1100 volts grade Control Cables all as specified and directed.
Supply and fix ACSR conductor on angle iron fabricated structure with continuous GI earth wire, for 33 KV bus bar and looping/connecting wire all as specified and directed.
Supply and fix cable jointing kit for 33 KV grade cable for out door termination heat shrink type joint complete and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 240 to 400 sqmm all as specified and directed.
Supply and fix cable jointing kit for 33 KV grade cable for in door termination heat shrink type joint complete and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 240 to 400 sqmm all as specified and directed.
Supply and fix cable jointing kit for 11KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminiuml conductor cable of size 50 to 95 sq mm all as specified and directed.
Supply and fix cable jointing kit for 11KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sq mm all as specified and directed.
Supply and fix cable jointing kit for 11KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sq mm all as specified and directed.
Supply and fix cable jointing kit for 11KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sq mm all as specified and directed.
M&L for Cross arms, bracings, supports, clamps, fabricated rectangular pole structure (for 33KV bus bar, breaker CT,PT, Gang & LA etc.) & back plates fabricated from structural steel sections/angle iron including galvanized nuts, bolts, washers welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of Aluminium paint paint all as specified and directed.
Supply, install, connection, testing and commissioning of UPS 5 KVA with 30 Volt DC low maintenance type chargeable battery of 15 cells of 02 Volts, 100 Amp-hour floor mounted type for input 230 volts (+ ) (-) 5% single phase 50 Hz AC complete for 33 KV&11 KV VCB panel with complete control wiring for connecting the DC tripping system to relays wiring shall be copper conductor of single core and size not less than 2.5 Sqmm running PVC conduit all as specified & directed complete.
Supply ,installation , testing & commissioning of grid earthing for outdoor switch yard all as per IS 3043-1987(Reaffirmed 2006)"Code of Practices for earthing " with 32x6 mm GI strip running parallel to each other in grid pattern spaced 3 M apart on one side and 6 M apart on the other side and earth electrode with earthing complete all as specified and directed at site . Items deemed to be included in the job are (a) Earthing of machinery /equipment installed at power house/sub station using 32x6 mm galvanized strip and size 600x600x6 mm GI plate as earth electrode -12 Nos. (b) Supply and fixing GI strip for connecting earth electrode and making earthing grid -800 RM (Earthings and Strips, if required extra shall be paid for separately under respective items.)
Material and labour for earthing complete with Copper earth plate electrode 600mmX 600mmX 3.15mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 meters below ground level, connected to and including Copper strip as earthing lead of size 25X3 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh, including char coal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value for Neutral and Body earthing of Power Transformer all as specified and directed.
Supplying, transporting to site, erecting and fixing in position of steel tubular swaged type poles 11 meters long, pole weight approximately 175 to183 kgs, pole should be in one piece only and smooth finishing, ISI marked complete with all accessories such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continuous GI earth wire as specified type 410 SP-55 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed make as approved. Note (i) Steel tubular pole shall be swaged and welded at manufacturer's factory and not at site inner surface shall be factory painted.
M&L for steel tubular swaged type poles 9 meters long, pole weight approximately 154 kgs, pole should be in one piece only and smooth finishing, ISI marked complete with all accessories such as cast iron base plate, finial taper plug, pole cap, bolts, nuts, screws, washers and drilling of holes for continuous GI earth wire as specified type 410 SP-32 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed make as approved. Note (i) Steel tubular pole shall be swaged and welded at manufacturer's factory and not at site inner surface shall be factory painted.
Supply and fix LED street light of Maximum 40W, total System lumens not less than 5200 Watts, High pressure die-cast aluminium housing, IP-66 ratings, Toughened clear glass front cover, Suitable for pole mounting with bracket arm 40-50 mm dia, Epoxy powder coated with additional treatment for anti-corrosive finish, High Bright LED with Lens, System efficacy not less than 130 Lumens per watt, Colour Temperature not less than 5700 Degree Kelvin, Colour Rendering Index Not Less than 74, Life Not Less than 50000 Hours of operation, Opticx-60 Degree beam angle, BIS Certified Silicongel potted driver, with APFC, PF not less than 0.9, THD less than 10%, with operating voltage-140 to 270 Volt AC, 50 Hz, With Heat Sink also including LM-79 and LM-80 Test reports from NABL Accredited Labs having TOP opening separate driver compartment with IP-66 protection and impact resistance of IK-07 with 10KV built-in-surge protection device including connecting of suitable pipe with brackets, nuts, bolts etc all as specified and directed.
Supply and fix cable junction box water & fire retardant proof out door type of approved size, hinged/screwed type made of SMC plastic single door with incoming and outgoing connector/terminals and comprising of MCB SP 6 Amps,240V,10KA,'C' Series and including galvanized flat iron clamps of size 25X5mm thick -02 Nos GI nuts, bolts & washers etc for fixing on PCC/Steel tubular pole/ wall surface etc and including dismentling & removing of old unserviceable item complete all as specified and directed "MAKE-SINTEX CAT NO GSJB4030 OR HENSIL CAT NO K9255"
Material and labour for PVC conduit heavy duty of size 20 mm dia from looping box to Street light connector, holding in MS clamp of size 25X2 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc and including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to light fitting connector and including dismentling & removing of old unserviceable item complete all as specified and directed..
Supply and fix GI bracket pipe of size 40 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on PCC & Steel poles/on wall surfaces and including suitable fabricate galvanized flat iron clamps of 30X6 mm thick -02 Nos suitable for fixing any place of poles with nuts, bolts & washers including grouting on wall etc and including dismentling & removing of old unserviceable item complete all as specified and directed.
Supply and fix 35W LED post top lantern new generation, post top, energy saving environmental friendly long life aesthetically designed with good indirect symmetrical light distribution die-cast aluminium landscape IP65 luminaries with high power COB LES as light source and providing suitable fixing arrangements such as lugs, glands, nuts, bolts and washers and complete all as specified and directed.
Supply & fixing of LED flood light on poles/Building as directed of Maximum 80W, total System lumens not less than 9600 Watts, High pressure die-cast aluminium housing, IP-65 ratings, Toughened clear glass front cover, Suitable for pole mounting with bracket arm 40-50 mm dia, Epoxy powder coated with additional treatment for anti-corrosive finish, High Bright LED with Lens, System efficacy not less than 120 Lumens per watt, Colour Temperature not less than 5700 Degree Kelvin, Colour Rendering Index Not Less than 74, Life Not Less than 50000 Hours of operation, Opticx-60 Degree beam angle, BIS Certified Silicongel potted driver, with APFC, PF not less than 0.9, THD less than 10%, with operating voltage-140 to 270 Volt AC, 50 Hz, With Heat Sink also including LM-79 and LM-80 Test reports from NABL Accredited Labs suitable for highlighting architectural façade and general purpose lighting with all connecting arrangement like brackets, bolts, nuts etc all as specified and directed by Engr-in-Charge
S & F Pin type insulator porcelain vitreous brown or white brown or green insulator including one galvanized mid steel spindle with one GI nut and two washer etc of size 260mm height and 290mm dia for 33000 volts electronic pressure, complete all as specified
Supply, install, connection of 11 kv single phase in door resin cast CT of ratio 400/5-5A class 1.0/5P10,burden 15VA-15 VA all as specified and as directed.
Supply, install, connection of 11 kv single phase in door resin cast PT of ratio 11 KV/rt3/110/rt3/110V/rt3, class 0.5 -3, Burden 50VA -50VA all as specified and as directed.
Supply & Fix PG clamps/flat pad connectors/sub stn. connectors made of aluminium alloy for making connection on 33 KV bus bar (OH Lines), CTs , PTs , VCBs etc complete all as specified.
S & F for four in series disc type assembly insulator porcelain vitreous white, brown or green in colour of size 145 mm height and 255 mm dia, disc insulator for tension with tension clamps for conductors, working pressure 11000 volts lts grade ball & socket type including nut complete all as specified and directed.
Supply, installation, testing and commissioning outdoor type CPRI approved LT feeder pillar box suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz ,outdoor type, double door type cubicle, floor mounted, free standing, dust and vermin proof, air ventilation made out of 3.0 mm thick CRCA sheet and MS angle of size 50 x 50 x 6 mm and flat duly powder coated and any manufacturer shall be followed CPRI norms and Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and civil work/PCC foundation as per site requirement and removing of old unserviceable LT panel from existing location after disconnecting of existing cables complete all as specified and directed including comprising of following:- (a) MCCB 315 Amps, FP, 16 KA,415 volts,50Hz-01 No. (b) MCCB 100 Amps,FP,16 KA,415 volts,50Hz-4 Nos (c) MCCB 63Amps,FP,16 KA,415 volts,50Hz-2Nos (d) Digital voltmeter, with VSS -01 set (e) Digital, Ammeter, with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 500 Amps rating -01 set (h) Panel control wiring with 4/6sqmm copper conductor and MCB DP 6-32 Amps.
Supply, installation, testing and commissioning CPRI approved LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz ,outdoor type, double door type cubicle, floor mounted, free standing, dust and vermin proof, air ventilation made out of 3.0 mm thick CRCA sheet and MS angle of size 50 x 50 x 6 mm of angle iron and flat duly powder coated and any manufacturer shall be followed CPRI norms and as approved by GE.Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and civil work/PCC foundation as per site requirement complete all as specified and directed including comprising of following:- (a) MCCB 125 Amps,FP, 16 KA,415 volts,50Hz-01 No (b) MCCB 63Amps,FP,16 KA,415 volts,50Hz-4 Nos (c ) Analogue time switch(Daily time switch) with suitable power contactor 32-40 Amps ML-2 type,3Phase,415 volts,Auto/Manual operating switches complete set for functioning -01 No's (d) Digital voltmeter,with VSS -01 set (e) Digital, Ammeter,with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 160 Amps rating -01 set (h) Panel wiring with 6.0 sqmm copper conductor and MCB DP 2-32 Amps.
Supply and fix LPR (Linear Polarization Resistance) Three phase static energy meter of accuracy class 1.0, three phase 240V, AC, 10-60 A and all as specified.
M&L for VTPN DB, 8 way,for 415V, Ac, 50Hz supply and MCCB 63A as incommer and MCB TPN 32A as outgoing complete with all connection and installation. Note:- Incoming and outgoing MCCB/MCBs will be measured and paid separately.
M&L for MCCB 4 pole 63 Amps to 100 Amps,50 Hz,415 volts with rupturing capacity 35 KA all as specified and directed.
M&L for MCB TPN 32A, 415V, Ac, 50 Hz rating all as specified and directed.
Supply and fix compact air insulated aluminium busbar 315 Amps,breaking capacity of 35 KA of 8 way and IP 54 protection complete with enclosure upto 1 m length with suitable MS Angle Iron for grouting of Busbar in ground/floor, necessary opening and locking arrangement, hinged door with rubber gaskets, bottom cable entry holes with PCC foundation as per site requirement all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 400 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 185 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm ; 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm ; 4 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm ; 4 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm ; 2 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm ; 2 core all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 sqmm ; 2 core all as specified and directed.
M&L for laying of Fly Ash Bricks over UG cable for protection complete all as specified and as directed.
Material and labour for GI pipe 50 mm dia "light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection complete all as specified and directed.
Material and labour for GI pipe 80 mm dia "light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection complete all as specified and directed.
Material and labour for GI pipe 100 mm dia "light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Supply and installation of Ring main unit (Four way ) Comprising of one incoming outdoor non-extensible Manual VCB and Three outgoing load break switch in SF6 filled enclosures each of 11 KV ,630 Amp 21kA/3sec, Non Extensible all as specified and directed at site. Non-Extensible Outdoor Manual VCB (1 No. Incomer) Details as under :- Nominal voltage: 11 kV Rated frequency: 50 Hz Rated current busbars: 630 A Rated current cable switch disconnector: 630 A Short time withstand current: - Cable switches disconnector with interface C (400-bolt) bushing: 21 k Arms 3 sec. - Vacuum circuit breaker with interface C (400-bolt) bushing: 21 k Arms 3 sec. Rated current for transformer T-off : 630 A Impulse withstand voltage: To earth and between phases: 75 kV Insulation level: - Power frequency 1 min: 28 kV Contd/-
Vacuum Circuit Breaker: Vacuum circuit breaker module with vacuum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy mechanism. Vacuum circuit breaker 12kV, 630A - 01 No Bushing Outside cone interface C for connection of external busbar - 01 No Self-Powered Over current and Earth Fault Protection Relay - 01 No Ring Core epoxy cast resin current transformer 100-50/1A, 2.5VA, 5P10 for protection - 03 Nos Capacitive Voltage indication system fixed 9-15 kV - 01 No Stored energy mech. for manual operation - 01 No Busbar Cover - 01 No Cable cover standard with Interlocking - 01 No Cable bushings interface C (400 bolted), 630A - 01 No Cable support bars, standard for 1-way unit - 01 No Contd/-
Each Load Break Switch (3 Nos Ougoings) Details as under :- Cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar. Cable switch 12kV, 630A - 01 No Bushings outside cone interface C for connection of external busbar - 01 No Manometer - 01 No Busbar cover - 01 No Snap action mech. for manual operation - 01 No Cable cover standard with Interlocking - 01 No Cable bushings interface C (400 bolted), 630 A, standard - 01 No Capacitive voltage indication fixed - 01 No Contd/-
Standards and Mechanical Details :- Metal Enclosed switchgear: IEC 62271-200 General Purpose switches: IEC 60265-1 Disconnectors and Earthing switches: IEC 62271-102 Switch Fuse Combination: IEC 62271-105 Circuit Breakers: IEC 62271-100 Common clauses: IEC 60694 Pressure of SF6 gas: 1.4 bar at 20 °C Cable bushings: DIN 47636 Temperature class: -25 °C - +40 °C Outdoor Degree of protection: - SF6 tank: IP 67 - Front cover: IP 2X - Cable cover: IP 3X - Enclosure IP 54 Busbars: 240 mm2 Cu Earth bar (external): 120 mm2 Cu - Bolt dimension: M10 Thickness of Stainless Steel Tank: 2.5 / 3.0 mm Colours: - Front cover: RAL 7035 - Side and cable cover: RAL 7035 - Enclosure IS 632
Supply and Fix Solar LED standalone street light range (2 days backup) for panel, battery, Pole, all accessories at required Watt -30W, Luminaire, System Voltage 12V, Lumen - 3150, MPPT, Solar Panel Wp 125, Battery LMLA/GEL) Ah-75, HDG Tubular Pole above ground -6M TUB Pole all as specified and directed.
M & L , hardcore of gauge not exceeding 40mm, deposited ,spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and directed.
M&L for Cable route indicator showing "HT Cable MES" and route/joint of cable with arrow made of CI path indicator 100 dia and 6 mm thick circular shape and fixed on angle iron 40x40x6mm, 600mm long painted with two coats of synthetic enamel paint cover a coat of red oxide primer duly embaded in PCC block 0.30x0.30x0.30 in ground complete all as specified.
Material and labour for PCC 1:2:4 type B1 using (20 mm graded stone aggregate) for making good cutting portion coping of pole and filling of foundation all as specified and directed.Note:- Top surface of pole coping to making smooth finishing and white washing made by the contractor, complete all as specified. (cost deemed to be included into quoted rete only).
S & F anticlimbing device, spikes type fabricated out of MS bars (round squre and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole , complete all as specified.
Material and labour for Construction of Soak Pit of Size 2000 X 2000 X 1500 mm internal dimensions , excavated in ordinary soil, Fdn in PCC 1:3:6, well in honey combed and solid in PCC M-25 (Design Mix) including intercepting chamber, screen chamber, with honey comb BW in CM, RCC cover slab in M-25/RR masonry/filling with brick bats with Cement Plaster in CM 1:4, 15 mm thick using Water Proofing Compound duly filled with clean dry sand all as specefied in TD & as directed as per Drg..
Supply and fixing HT 33 KV Danger notice plate of size 250mm x200 mm made of mild steel 1.6 mm thick and vitreous enamel wide on both side and inscription in signal red colour with skull and bone on front side complete with words in Hindi, English and Bengali, all as spiced and directed
Supply and fixing HT 11 KV Danger notice plate of size 250mm x200 mm made of mild steel 1.6 mm thick and vitreous enamel wide on both side and inscription in signal red colour with skull and bone on front side complete words in Hindi, English and Bengaliall as spiced and directed
Supply and installing at approved location approved make 04 Nos. fire buckets of 24 gauge galvanized steel painted white inside and red out side and black on the bottom inscribed with letters FIRE in black and gold including stand fabricated out of sheet metal 16 gauge shade platform and associated civil work painting etc as approved.
Supply only fire extinguishers dry chemical type powder type ISI marked portable trolley type capacity 6 Kg complete all as specified and as directed.
Supply only ISI marked portable fire extinguishers CO2 type capacity 4.5Kg complete all as specified and as directed.
Supply and fixing standard shock treatment charts in English & Hindi and Bengali duly framed and covered with glass complete all as specified and directed.
Supply and fixing first aid box as per IS-2271 and all as directed at site.
Supply and eracting of single piece non linear resistor type lightening arrestor gapless metal oxide (ZnO) suitable for 3 wire 11 KV overhead lines with rated voltage of 11 KV (rms) 10 KA discharge current with a (station class) with facility to record number of surge and complete with galvanized clamping arrangments clamp, bolt, nuts and washers etc as required.
SCHEDULE 'A' PART X (MISC COMMON B/R & E/M ITEMS)
Surface excavation not exceeding 30cm deep and averaging 15cm deep and geting out in soft/loose soil complete all as specified and as directed.
M&L for lying of sand for cushioning for cable protection over cables/filling under floor or in fdn complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified.
M&L for PCC (1:3:6) type C2 using (40 mm graded stone aggregate) for planting depth of pole , in foundation filling and mass concrete including necessary formwork etc complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using (40 mm graded stone aggregate) for making bed concrete, filling of foundations etc complete all as specified and directed.
Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed..
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth for foundation , etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 Sqm on plan and n exc 1.5 m depth beyond and getting out in soft/loose soil all as specified and directed.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m nean radius, built in CM 1:4 and complete all as specified and as directed.
S&F TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to complete all as specified and as directed.
S&F TMT bars 5 mm dia and over upto and including 10mm dia in stirrups spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to complete all as specified and as directed..
M&L for Reinforced concrete pipe , class NP-2, laid and jointed complete with collers 450 mm bore and complete all as specified and as directed.
M&L for rendering 15 mm thick on Brick Work or Concrete Surfaces in CM (1:4) finished even and smooth without using extra cement including WPC and complete all as specified and directed.
M&L for providing pre cast RCC cover built in 1:2:4 (type B1) using 20 mm graded aggregates and set in CM 1:4 and complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregates) as in coping, bed plates, kerbs etc including weathering, slightly rounded or chamfered angle and throating including necessary formwork and finished surfaces fair and even using extra cement all as directed.
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth for foundation , etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 Sqmm on plan and n exc 1.5 m depth beyond and getting out in soft/disintigrated rock all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32X6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh, including char coal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed.
SCHEDULE 'A' PART XI (OPEN DUCT)
M&L for chequred plates channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410, Grade E-250 complete all as specified and as directed.
FRIZO INDIA PVT LTD
M M Brothers
SHRI GANESH ENTERPRISES
Konstelec Engineers Pvt. Ltd.
Sant Construction Co.
Saggi Electric company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .