Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.5 LAccepted-AOC | ₹29.5 L | 1 | Accepted-AOC Awarded |
| 2 | 2₹29.9 LRejected-AOC | ₹29.9 L | 2 | Rejected-AOC Not Awarded |
| 3 | 3₹30.2 LRejected-AOC | ₹30.2 L | 3 | Rejected-AOC Not Awarded |
| 4 | 4₹35.5 LRejected-AOC | ₹35.5 L | 4 | Rejected-AOC Not Awarded |
Tender Value
₹29.9 L
EMD Value
₹30,000
Closing Date
8 Oct 2020, 5:00 pmClosed
S.E., E.T.C., Bareilly
Superintending Engineer Transmission Campus Near L.I.C. Office Rampur Garden, Bareilly
Operation and Preventive, Routine and Breakdown Maintenance, General Cleaning, Maintenance of Lawns, Cable Trench Cleaning, Operation and Maintenance of Mulsifyre and Hydrant System, Periodic Cutting of Grass at 220KV S/S Pilibhit under ETD-II, Bly
2020_UPTCL_511608_1
E-Tender No. 28 / W / ETC(B) / 2020 - 21
Open Tender
Electrical Works
365 days
Bareilly
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
Yes
A/c No 10897666087 IFSC SBIN0000615 S.B.I. Bly
₹30,000
14 Oct 2020
15 Sept 2020
9 Oct 2020
15 Sept 2020
8 Oct 2020
15 Sept 2020
15 Sept 2020 - 8 Oct 2020
Amount
Operation and Preventive, Routine & General / Normal Breakdown Maintenance of the Sub Station including Daily General Cleaning, Regular Maintenance of Lawns, Cable Trench Cleaning, Operation & Minor Maintenance of Mulsifyre & Hydrant System, Periodic Cutting of Grass & Jungle Clearance and Periodic Up-Rooting of small Wild Trees / Plants alongwith other associated Works at 220KV S.A.S. Sub Station Pilibhit under E.T.D. - II, Bareilly during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021, as per Details below :
(1) Operation of 220KV S.A.S. Sub Station Pilibhit, Round the Clock in 3 Shift of 8 Hours each Per Day by Deploying a Team Consisting of the Technical Personnel (1 No. TG - II / S.S.O. with I.T.I. in Electrical Trade and having Knowledge of Computer Application and 1 No. Skilled Helper to Assist the T.G. - II on Duty in Shift) in each Shift (Total 4 No. Shifts; 1 No. Shift being on Rest per Day) by due Operation of the Sub Station Equipments, Transformers including DG Set etc. as per Standard Practices of UPPTCL and Instructions of S.D.O. / J.E. and SLDS / ALDS alongwith Recording of Operational Activites, System Information / Data, Messages etc., as per Details in Annexure - A, during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021, with all Cost of Men Required for the Job. (1 Job for each Month)
(2) Preventive, Routine & General / Normal Breakdown Maintenance of the Transformers, Outdoor / Indoor Equipments, Control & Relay Panels, RTCC Panels, PLCC Equipments, ACDBs, Battery Chargers, DCDBs, Battery Sets etc., Split / Window ACs, Indoor & Outdoor Lighting Arrangement etc. at 220KV S.A.S. Sub Station Pilibhit, as per Details in Annexure - B, Round the Clock and / or as and when Required by a Team Consisting of the Following Technical Personnel as per Standard Practices of UPPTCL and Instructions of S.D.O. / J.E., during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021, with all Cost of Men, Misc. Consumables, T&Ps etc. Required for the Job except the Spares / Items / Materials / Equipments, that shall be Provided by the Department. (1 Job for each Month) : (a) T.G. - II (Experienced I.T.I. in Electrical Trade) : 1 No. (b) Line Man / Fitter / Technician (Experienced) : 2 No. (c) Skilled Helper (Experienced) : 2 No.
(3) Daily General Cleaning and Maintenance / Upkeep of Control Room, associated Offices, Carrier Room, Battery Room, Control Room Building, etc. by Brooming & Mopping alongwith Cleaning of associated Toilets including Brooming of C.C. Roads / Floors, Trench Covers & Scraping of Unwanted Growths in between Joints of the C.C. Roads at 220KV S.A.S. Sub Station Pilibhit and associated Colony Premises, as per Details in Annexure - C by Deploying Required Man Power / Sweeper during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021, with all Cost of Men, Toiletries, Misc. Consumables, T&Ps etc. Required for the Job. (1 Job for each Month)
(4) Regular Maintenance of Lawns / Garden, Flower Bed, Hedges, Flower Vases etc. including Proper Cutting / Trimming of Grass, Hedges, Ornamental Plants / Trees, Seasonal Flowers etc. including Watering, Making Loose Soil around the Plants / Trees, Flower Beds etc. at 220KV S.A.S. Sub Station Pilibhit, as per Details in Annexure - D by Deploying 1 No. Experienced Gardener to Keep them Healthy & Green including Replacement of Aired Plants, Grass, Seasonal Flowers etc. with Fresh Plants, Grass, Seasonal Flowers etc. of same Variety and Providing of well Decomposed Organic Manure, during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021, with all Cost of Men, Materials, Misc. Consumables, T&Ps etc. Required for the Job. (1 Job for each Month)
(5) Thorough Cleaning of Cable Trenches of various Sizes alongwith associated Cable Racks at 220KV S.A.S. Sub Station Pilibhit in the Month of October / November 2020 after end of Rainy Season by Removing Mud, Silt, other Foreign Materials in the Cable Trenches and from the Cable Racks after due Opening of the Trench Covers, then Disposal of the Garbage, Mud, Silt, Waste, Foreign Materials etc. Outside the Sub Station Premises and Finally, Covering the Cable Trenches with respective Trench Covers after Completion of the Work with all Cost of Men, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer.
(6) Regular Operation, Checking, Servicing & Minor Maintenance of Mulsifyre System installed on 160MVA & 100MVA 220/132KV Transformers and Hydrant System installed at the Sub Station on Daily basis and as per Requirement during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021. The Work includes Regular Checking & Arresting of Leakage of Water, Changing of Gland Rope, Maintaining Proper Level of Water in Tank, Keeping Constant Watch on Frequency of Running of Water Jockey Pump, Smooth Running of Main Pump, Self Starting System, Condition of Battery & Battery Charger so as to Keep Battery Healthy with its Required Maintenance, Servicing of Deludge Valve, Foot Valve, Gate Valve, Sluice Valve etc., Replacement & Cleaning of Defective Nozzles, Replacement of Quartz Bulb etc. that shall be Provided by the Department, as per Requirement including Recording all Parameters during Operation of the Mulsifire System and Hydrant System in the Register. (1 Job per Month)
(7) Periodic Clearance of Dense Jungle and Cutting of Grass, Kusha & Kansa including Uprooting of the Rank Vegetation, Grass, Bushes, Shrubs etc. by Scrapping of Grass, Bush, Bush Wood, Shrubs & Plants etc. above 2" over the Ground Level; Weeding out the wild Growth Roots, Seeds etc. and Collection of the Foreign Materials like Kankar, Ballast, Pebbles, Waste Papers etc. in Switchyard Area between Chain Link Fencing & Security Fencing / Wall, Area around Control Room / Committee Room, Area around Store Shed, Open Store Yard, Colony Area etc. at 220KV S.A.S. Sub Station Pilibhit and Finally, Disposal of all the Removed Vegetation, Rubbish & Garbage etc. by Throwing it Outside the Periphery of the Sub Station Premises during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021, with all Cost of Men, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer, as per Details below : (a) 1st Cutting between 1st November 2020 to 30th November 2020
(b) 2nd Cutting between 1st February 2021 to 28th February 2021
(c) 3rd Cutting between 1st May 2021 to 31st May 2021
(d) 4th Cutting between 1st August 2021 to 31st August 2021
(8) Periodic Up-Rooting of small Trees in Switchyard Area, Area between Chain Link Fencing & Security Fencing / Wall, Area around Control Room / Committee Room, Area around Store Shed, Open Store Yard, Colony Area etc. at 220KV S.A.S. Sub Station Pilibhit by Digging and Taking out the complete Root, then Leveling the Ground, so Excavated and Finally, Disposal of all the Removed Vegetation, Rubbish & Garbage etc. by Throwing it outside the Periphery of the Sub Station Premises during the Period of 1 Year w.e.f. 01.11.2020 to 31.10.2021, with all Cost of Men, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer, as per Details below : (a) 1st Up-Rooting between 1st November 2020 to 30th November 2020
(b) 2nd Up-Rooting between 1st February 2021 to 28th February 2021
(c) 3rd Up-Rooting between 1st May 2021 to 31st May 2021
(d) 4th Up-Rooting between 1st August 2021 to 31st August 2021
LASHANI ENTERPRISES
Technocrat Electrical
A.RAMAN POWER ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid