Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.3 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹36.9 L+₹59,000 (1.63%)Rejected-Finance DANGRA TOLI CHOWK PURULIA ROAD RANCHI | RANCHI | 2 | Rejected-Finance OTHER THAN LOWER |
| Sl No | Description | Qty | Unit | Blaca Corporations L2 | CHANDRA BROTHERS L1 |
|---|---|---|---|---|---|
| 1.00 | Supplying, installation, testing and commissioning of water cooled type vertical turbine pump set of Kirloskar /Jyoti/ WILO /WPIL make capable to discharge 135 m3/hr against a total head of 47 meter with suitable size of column assembly (MS), flange type 10’ long each heavy duty with line shafts, 60’(feet) spider bearings, cuttless rubber bushes, sleeves and discharge head etc as required coupled with suitable size of hollow/solid shaft, squirrel cage IE3 induction motor as per IS 12615 : 2011 with latest Amendments operated on 415 volt 3 phase, 50 c/s, 1400-1500 rpm with non reversible rather coupling (make Kirlosker/Jyoti/CGL/ABB or reputed) with suitable size of ISI marked heavy duty CIDF sluice valve, CIDF NR valve, pump strainer etc including transportation, loading and unloading charges all complete and testing on load. | 2 | Sets | 27,50,000 ₹27,50,000 | 27,00,000 ₹27,00,000 Lowest |
| 2.00 | Lifting of old pump set from well after opening on mounting bolts with all labour, tools and tackles. | 2 | Job | 16,000 ₹16,000 | 14,000 ₹14,000 Lowest |
| 3.00 | Fitting of sluice valve, NR valve with supply fitting of rubber insertion- 03 Kg nut bolt & washer ¾’ dia x 4’ long – 16 nos., 4” dia m/s pipe, 5’ long – 01 no., cutting and welding of pipe to common header with gas cutter & welding set and making leak proof joint testing on load including all labour tools and tackles. | 2 | Each | 48,000 ₹48,000 Lowest | 48,000 ₹48,000 Lowest |
| 4.00 | Supplying,Installation and commissioning
motor control panel Board with FASD starter suitablefor 40HP VT pump sets including supplying and
fitting following:
(A)Incoming feeder-
(i) 100 amp MCCB-1 no.
(ii) 200 amp copper bus bar arrangement (4 pole). (ii) Phase indicating lamp-02 nos.
(B) Out going feeder
(i) 63 amp MCCB-2 Nos.
(iü) Volt meter l no.
(iii) Amp meter -2 nos.
(iv) Pilot lamp - 4 nos.
(v) Selector switch-2 nos.
(vi) FASD (ml-04) starter -2 no.
(vi) Single phase preventor - 2 nos.
Complete internal wiring with suitable size of copper wire and testing on load. | 1 | Set | 2,50,000 ₹2,50,000 Lowest | 2,50,000 ₹2,50,000 Lowest |
| 5.00 | Supplying and laying of 10 mm2x 3 core PVC insulated and PVC sheathed copper conductor for power wiring from panel to motor for -02 sets.. | 40 | Mtrs | 29,600 ₹29,600 | 29,000 ₹29,000 Lowest |
| 6.00 | Supplying and laying of 35 mm2x 4 Core Copper Armoured Cable for power wiring from panel to change over and complete replacement of existing aluminium cable. | 20 | Mtrs | 55,000 ₹55,000 | 54,400 ₹54,400 Lowest |
| 7.00 | Supplying and erecting of earthing station as per IE rule including the cost of earth pit, 8 SWG copper wire, G.I. pipe all complete with sand, charcoal and salt etc to all electrical equipment in double way wire connection. | 2 | Nos | 24,000 ₹24,000 Lowest | 24,000 ₹24,000 Lowest |
| 8.00 | Supplying and fitting 200 A change over switch, L&T/Havell's. | 2 | Job | 45,000 ₹45,000 | 40,000 ₹40,000 Lowest |
| 9.00 | Supplying and fitting 200 A Switch fuse unit, L&T/Havell's | 1 | Job | 10,500 ₹10,500 | 10,000 ₹10,000 Lowest |
| 10.00 | Supplying installation testing and commissioning of 90 watt LED (make Havell's, Bajaj, reputed) at existing pole and building aiong with suitable arm/bracket wire 1.5 mm2, switch etc all complete. | 1 | Job | 9,300 ₹9,300 | 9,000 ₹9,000 Lowest |
Tender Value
₹36.2 L
EMD Value
₹72,500
Closing Date
23 Apr 2026, 5:00 pmClosed
Executive Engineer DW and S Mech Division Gumla
Executive Engineer, D.W. and S. Mech. Division, Gumla
Supplying installation and commissioning of VT pump sets having discharge 135 m3hr head of 47 mtr SF of electrical panel suitable for 40HP VT pump set 100 KVA stabilizer etc at RW P plant for Sisai old rural WSS Gumla
2026_DWSD_112934_1
e-tender no -01/2026-27
Open Tender
Pumps/Motors
Item Wise
45 days
GUMLA
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹72,500
18 May 2026
16 Apr 2026
25 Apr 2026
16 Apr 2026
23 Apr 2026
16 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, testing and commissioning of water cooled type vertical turbine pump set of Kirloskar /Jyoti/ WILO /WPIL make capable to discharge 135 m3/hr against a total head of 47 meter with suitable size of column assembly (MS), flange type 10’ long each heavy duty with line shafts, 60’(feet) spider bearings, cuttless rubber bushes, sleeves and discharge head etc as required coupled with suitable size of hollow/solid shaft, squirrel cage IE3 induction motor as per IS 12615 : 2011 with latest Amendments operated on 415 volt 3 phase, 50 c/s, 1400-1500 rpm with non reversible rather coupling (make Kirlosker/Jyoti/CGL/ABB or reputed) with suitable size of ISI marked heavy duty CIDF sluice valve, CIDF NR valve, pump strainer etc including transportation, loading and unloading charges all complete and testing on load. | - | Sets | - | - |
| 2 | Lifting of old pump set from well after opening on mounting bolts with all labour, tools and tackles. | - | Job | - | - |
| 3 | Fitting of sluice valve, NR valve with supply fitting of rubber insertion- 03 Kg nut bolt & washer ¾’ dia x 4’ long – 16 nos., 4” dia m/s pipe, 5’ long – 01 no., cutting and welding of pipe to common header with gas cutter & welding set and making leak proof joint testing on load including all labour tools and tackles. | - | Each | - | - |
| 4 | Supplying,Installation and commissioning
motor control panel Board with FASD starter suitablefor 40HP VT pump sets including supplying and
fitting following:
(A)Incoming feeder-
(i) 100 amp MCCB-1 no.
(ii) 200 amp copper bus bar arrangement (4 pole). (ii) Phase indicating lamp-02 nos.
(B) Out going feeder
(i) 63 amp MCCB-2 Nos.
(iü) Volt meter l no.
(iii) Amp meter -2 nos.
(iv) Pilot lamp - 4 nos.
(v) Selector switch-2 nos.
(vi) FASD (ml-04) starter -2 no.
(vi) Single phase preventor - 2 nos.
Complete internal wiring with suitable size of copper wire and testing on load. | - | Set | - | - |
| 5 | Supplying and laying of 10 mm2x 3 core PVC insulated and PVC sheathed copper conductor for power wiring from panel to motor for -02 sets.. | - | Mtrs | - | - |
| 6 | Supplying and laying of 35 mm2x 4 Core Copper Armoured Cable for power wiring from panel to change over and complete replacement of existing aluminium cable. | - | Mtrs | - | - |
| 7 | Supplying and erecting of earthing station as per IE rule including the cost of earth pit, 8 SWG copper wire, G.I. pipe all complete with sand, charcoal and salt etc to all electrical equipment in double way wire connection. | - | Nos | - | - |
| 8 | Supplying and fitting 200 A change over switch, L&T/Havell's. | - | Job | - | - |
| 9 | Supplying and fitting 200 A Switch fuse unit, L&T/Havell's | - | Job | - | - |
| 10 | Supplying installation testing and commissioning of 90 watt LED (make Havell's, Bajaj, reputed) at existing pole and building aiong with suitable arm/bracket wire 1.5 mm2, switch etc all complete. | - | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
NIT-1.pdf
Tender Documents • 3.01 MB
BOQ_152503.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .