Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79,525Accepted-AOC BETHAL THIRUMALA TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹87,087+₹7,562 (9.51%)Rejected-Finance THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical L3 |
Tender Value
₹97,258
EMD Value
₹2,500
Closing Date
5 Sept 2024, 5:00 pmClosed
Executive Engineer
Executive Engineer Thiruvananthapuram Corporation 695033
E3/MS/3806/23 Electrification Health and Wellness Center Near by Nemom Community Hall at Nemom Ward
2024_LSGD_687905_2
EE(C)/PLAN FUND TENDER/2024-25 (08)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹2,500
Yes
21 Jan 2025
27 Aug 2024
7 Sept 2024
27 Aug 2024
5 Sept 2024
27 Aug 2024
Amount
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. a) 1.55.2 : Group B
od1753362/2022_2023 : Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply. (5 star).
90.3.20 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 90.3.20.3 1200 mm 1X20W LED Lamp with box type fixture
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS732 as required.
1.47 : Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
MR (OD) Supply and installation of 18 watts ceiling mount LED light (down light)
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. As required.
od1753358/2022_2023 : Supply and providing the following types and power rated lamps in the existing fittings as required B22 LED bulb 10 W.
90.3.12 Conveyance and fixing charges of recess mounting down light fittings of all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required.
od1753357/2022_2023 : Supplying and fixing cast aluminium bulk head fitting with mesh guard with 7W LED bulb and giving connection etc. as required.
Od67349/2022-2023 : supply conveyance installation testing and commissioning of exhaust fan of sizes up to 450mm in the existing opening fixing necessary anchor bolt/bolt and nut etc. As required including giving connection with the supplied wire along with the exhaust fan 300/305mm sweep light duty exhaust fan in the metal frame working on 230v A/C supply.
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required
90.4.10 Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchorbolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
Supplying and fixing following way,single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 2.3.3 : 12 way double door.
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required.(For light plugs to be used in non residential buildings).
1.27.2 :Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular pate & switch box including connections but excluding modular plate etc. as required. A) 1.24.3 : 15/16 amps switch
B) 1.24.5 : 15/16 socket outlet
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. A) 1.14.1 : 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
B) 1.14.2 : 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth Wire.
C) 1.14.3 : 2X 4 sq. mm + 1 X 4 sq. mm earth Wire.
Od17437 /2022-23 : supply providing and fixing 32 amps SP&N disconnected fuse switch unit in sheet steel in enclosure with ISI marked HRC fuses on wall / angle iron frame including drilling holes in frame making connections etc as requires.
Od17435 / 2022-23 : supply and fixing 32 amps HRC fuse with HRC fuse link with connection in the existing meter board.Od17435 / 2022-23 : supply and fixing 32 amps HRC fuse with HRC fuse link with connection in the existing meter board.
Od17436 / 2022-23 : supply and fixing 32 amps 2 way neutral link mounted on DMC/SMC base with connections in existing meter board.
90.14.1.2 : Fabrication,supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurements will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame).
5.3 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection metre as required. 3.15 mm copper conductor ( 10 SWG)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG)
Od54401/2022-2023 : supply and providing brass bolt and nut 25 X 3mm.
90.3.18 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. 90.3.18.2 : 32 mm dia with HG company fabricated clamps. (For supporting service wire)
DIVIN SAM D S
ASOK ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1070462.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .