Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹50.5 L+₹4.9 L (10.6%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹50.8 L+₹5.1 L (11.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹51.9 L+₹6.3 L (13.7%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L4 | Rejected-Finance L4 | |
| 5 | L5₹53.6 L+₹7.9 L (17.4%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
5 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Bhamre Kiran S
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
REPAIR AND MAINTENANCE OF LIGHTENING PROTECTION SYSTEM AND CONNECTED ACCESSORIES OF VARIOUS TECHNICAL BUILDINGS AT GE(AF) JAMNAGAR NO.1
2021_MES_476300_2
8124/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO.1
₹89,000
Yes
27 Nov 2021
21 Oct 2021
6 Nov 2021
21 Oct 2021
5 Nov 2021
28 Oct 2021
60 days
Amount
M & L in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long all as specifed and directed.
M & L in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long all as specifed and directed.
S&F in repairs Air termination, with 5 spikes Star pointed copper rod 15 mm dia and 1500 mm long and 100 micron copper bonded lightening conductor with base fixed in position on pole complete with clamp and nut bolts all as specifed and directed.
Supply and fix in repairs 25 mm size epoxy type insulator suitable for fixing earthing strip including screw etc all as specifed and directed.
Supply and fixing in repairs copper earth strip of size 20 x 3.15 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal all as directed.
Supply and fixing in repairs copper earth strip of size 32x6mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal all as directed.
Supply & fix in repairs aluminium strip 25 mm x 3.15 mm complete with saddles and fixing screws for fitting the strip all as specifed and all as directed.
Supply and fix in repairs Test point terminal block made of gun metal or phosphorus bronze size of 75 mm x 75 mm x 25 mm drilled and screwed fixing in FRP box complete all as specifed and directed.
Material & Labour for brazing of copper strip of different size complete all as specifed and all as direced.
S&F in repairs PCC block Hollow (15cmx15cmx20cm) for fixing of GI/Aluminium/Copper strip with suitable size of insulators on roof top complete all as specified and as directed.
Material and labour in replacement for provision of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32 x 6 mm by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including.....
.....all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note : (i)Earth result after installation completely should be less than 5 Ohm . (ii)Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length.
Material and labour in replacement of earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to copper strip of size 20 mm x 3 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, .......
........type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:- Quoted rates shall be deem to include for earth strip with protection pipe of 7.5 M length.
Material and labour in replacement for tripod chemical earthing (comprising of three chemical earthing) as per drawing attached (Sketch No 01). The chemical earthing will have specification as follows :- Make:- Powertrac/McML Earthing Solution/Ashlock. (a) Copper electrode of wall thickness minimum 2 mm not less than 3 mtr length with not less than 75mm outer dia . (b) Fixing of copper Earth Electrode by drilling / boring 175 mm dia hole, 5.00 mtr deep in any type of strata, placing electrode in hole, return filling excavated soil by mixing min 10 kg GEL per bore and 75 kg Soil Resistivity Improvement (SRIP) compound as per manufacturer instruction
c) FRP earthing result display board 254 x 380mm made out of plastic material showing information related to type of earthing, earthing result, due date of testing along with fixing size 610mm height made of plastic hollow pipe of dia 20 mm. (d)Heavy duty poly plastic Earth pit cover of HDPE material, green color, Bottom diameter ( OD 320 mm / ID 290 mm) of wall thickness 5 mm, height 260 mm with top cover, fixed in position as per manufacturer instruction complete by use of pCC around the cover for setting it properly on ground surface.
(f) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work. (g) Contractor must produce the certificate from the manufacturer that chemical earthing has been carried out by manufacturer. (h) Extension strip from electrode strip up to 0.15 m height from GL and interconnecting strip of electrode shall be deemed included in quoted rate including brazing. (g) Earthing resistance result shall be less than 1ohm.if the result comes more than 1 ohm ,the contractor shall carry out the earthing at seperate location /sie given by engg- in- charge after taking out of earth electrode without any extra cost to the department.
M&L in replacement for stainless steel mast of 38 to 40 mm dia and length 2.30 metre (approximate weight 3 kilogram) fixed on roof slab/wall duly embedded in and including cement concrete (1:2:4)of size 40x40x40cm complete for supporting mast complete all as specified and directed.
M&L in replacement for stainless steel mast of 38 to 40 mm dia and length 3.0 metre (approximate weight 6.40 kilogram) fixed on roof slab/wall duly embedded in and including cement concrete (1:2:4)of size 40x40x40cm complete for supporting mast complete all as specified and directed.
S&F in repair Supporting tripods to fix lighting conductor or elevation masts to flat roofs and galvanised steel with bolt hole 12mm, height 330MM , dimensions of base 200x200mm and centraline distance 160x160mm Extension mast of stainless steel mast size 38 to 40mm dia of height 3 Mtr with screw and fixing kit (5 coolars, 4 nuts and bolts) including accessories all as specified and directed
S&F in repair of Early Streamer Emission (ESE) lightening arrestors of color- steel white and material- stainless steel, installed at pole on building height upto 16 mtr and shall confirmed to NFC 17-102-2011, Efficency >095 &<_98 for level 1 with the length 80cm , ∆t For early stremer warning 40 µSec for 58 protection redius at Height of 5 mtr and connected copper cable to earthing all as specified and directed . Make SABO model No LAP BX125 or equivanlent of ABB, powertec , Ashlok
S&F in replacement of Sheet moulding compound (SMC) junction box of size 200X140X95mm mild steel clamps, nuts and bolts complete. Make : SINTEX model No GSJB-2014 or equivalent make Legrand / EPP Composite Pvt Ltd
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil..
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and fixing in repair Unplasticised PVC pipe of pressure rating 10 kg/cm2 of size 15 mm bore (internal dia) ISI marked laid in trenches / on floor, ceiling etc including with all fitting such as elbow, union reducer tees bends etc complete all as specified and directed.
Supply and fixing in repair Unplasticised PVC pipe of pressure rating 10 kg/cm2 of size 20 mm bore (internal dia) ISI marked laid in trenches / on floor, ceiling etc including with all fitting such as elbow, union reducer, tees, bends, etc complete all as specified and directed.
Supply and fix in repair 15 mm size UPVC half turn cock valve for UPVC pipe and fixed ISI marked complete all as specified and directed.
Supply and fix in repair 20 mm size UPVC half turn cock valve for UPVC pipe and fixed ISI marked complete all as specified and directed.
Supply and fix in repair 15 mm size PVC perforated caps screw to end of puff or vent pipe fixed on UPVC pipe and its should ISI marked complete all as specified and directed .
Supply & Lay XLPE insulated PVC inner sheathed armoured with galvanised steel strip or wire, heavy duty LT underground cable ISI marked with aluminium multistranded conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches/duct passing through pipe/duct or fixed on pole and connecting and testing and including taking out old one with cable cover complete all as specifed and directed.
Supply & Lay XLPE insulated PVC inner sheathed armoured with galvanised steel strip or wire, heavy duty LT underground cable ISI marked with aluminium multistranded conductor 1100 volts grade of size 25 sqmm 3.5 core laid in trenches/duct passing through pipe/duct or fixed on pole and connecting and testing and including taking out old one with cable cover complete all as specifed and directed.
Supply & Lay XLPE insulated PVC inner sheathed armoured with galvanised steel strip or wire, heavy duty LT underground cable ISI marked with aluminium multistranded conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches/duct passing through pipe/duct or fixed on pole and connecting and testing and including taking out old one with cable covercomplete all as specifed and directed.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: For measurement purpose punned thickness of sand will be considered.)
Laying only PCC cable cover for HT / LT UG cable, of any description retrieved from item No 31, all as specified and directed by Engr-in-Charge.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
M&L for back filling earthing compound as per standard IS 3043, IEEE 80and IEC 62561-7 for improved gound resistivity improver compound in powder form for the earthing effectiveness and improves conductivity of the earth eletrode and ground contact area and Eco frindly & effective for mainly consist of moinsutre , high conductivity , non- corrosive in nature and absorbs > 13 times water than its volume , resistivity <0.5ohm-mtr and NABL lab tested 0.039 Ohm-metc and in power physical state with taking down exisitng chemical rod and fill the back filling compound with mixing with water all as specifed and directed by Engineer in charge Make -JJ Engineering / SM Infotech / Powertack/ Power Plus/SABO
Supply and fix in repair GI funnel of any type to be fix in existing earth pit. Cleaning of earth chamber is to be taken care complete all as directed by Engr-in-charge
Supply and fix in repair Stranded copper cable coated in PVC is used as an internal earth conductor size 10 Sqmm single core and high resistance insulation confirming with IS-694, IEC 62305, IEC 62561 for connecting with lighting termination and complete all as directed.
Raj brothers
ambika electric co
fakhrie apostrical
S t modi
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .