| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.2 L+₹91,480 (2.16%)Rejected-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L2 | Rejected-AOC L2 | |
| 3 | L3₹45.8 L+₹3.5 L (8.35%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L3 | Rejected-AOC L3 | |
| 4 | L4₹49.4 L+₹7.1 L (16.8%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
29 Jun 2020, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun The Mall Road Dehradun Cantt
REPAIR AND MAINT OF HT INSTALLATION TRANSFORMER UG CABLE AND CONNECTED WORKS AT GARHI CANTT DEHRADUN
2020_MES_342688_2
9582/DDN/06/E8
Open Tender
Civil Works
Item Rate
120 days
Dehradun
As per NIT
8 documents required · 8 mandatory
₹1,000
GE Dehradun
₹1.1 L
Yes
11 Aug 2020
23 May 2020
1 Jul 2020
23 May 2020
29 Jun 2020
15 Jun 2020
Amount
Disconnecting of HT/LT Connections including drain out of oil in barrels and kept aside for reuse and lifting with crane including transportation of transformer of capacity up to 250 KVA at civil workshop for necessary repair work complete all as specified and directed.
All as per srl item No 1 above but of capacity above 250 KVA but upto 500 KVA.
Dismantling of transformer for repair up to 250 KVA removing & lifting of top plate of transformer burnt oil seal, stud, nut, bolt, HT bushing, off load tap changer, butcholz relay, gate valve, dead plug etc for repair to core and winding including taking out of the same & replacing with new and repair for minor leakages (if any) and fix the same complete including top up the oil after dehydration complete all as specified and directed. Note:- Windings, dehydration of oil, New Oil and other accessories shall be measured and paid for separately.
All as per srl item No 2 above but of capacity above 250 KVA but up to 500 KVA.
M&L for repair to unserviceable transformer core & windings including taking out and testing for serviceability and rewinding the same with fresh copper wire or strip including insulation paper bobins etc and keeping the same in to the hot air oven till the moisture is removed & insulation resistance improves to the satisfaction level, re fixing the same in original position complete for the following size transformers:-
(b) 300 KVA to 350 KVA
(c) 200 to 250 KVA
(d) 100 KVA to160 KVA
M&L to repair to unserviceable transformer core & windings including taking out and testing for serviceability and rewinding the same with fresh alluminium wire or strip including insulation paper bobins etc and keeping the same in to the hot air oven till the moisture is removed & insulation resistance improves to the satisfaction level, re fixing the same in original position complete for the following size transformers:-
Note for item No 5&6:- (i) One year warranty certificate shall be submitted to the department after completion of job. (ii) Test certificate shall be submitted before commissioning of transformer. (iii) Any defect noticed during defect liability period shall be rectified by the contractor without any extra cost.(iv) New transformer oil, dehydration shall be measured and paid separately.
M & L for painting with two coats of DUCO enamel paint of ICI brand of approved colour over a coat of red oxide metal primer after scrapping thoroughly the existing corroded paint, dirt/dust, oil and grease from the steel surface of the transformer complete all as specified and directed for the following size .
(a) Upto 100 KVA transformer (11/0.433 KV)
(b) Above 100 KVA but upto 200 KVA transformer (11/0.433KV)
(c) Above 200 KVA upto 500 KVA (11/0.433KV)
(d) Transformer 3.15 MVA
Supply and fix transformer off load tap changer suitable for 400 to 500 KVA transformers 11 KV/433 volts minimum five steps type including removing the old unserviceable off load tap changer complete all as specified and directed.
All as per Item No 8 above but below 400 KVA.
Supply & filling the new transformer oil for topping up or in replacement of transformer/voltage stabilizer complete all as specified and directed.Note:- (i) Oil shall be in company sealed barrels with BDv not less than 40 KV at 2.5 mm gap.(ii) Topping up of transformer oil as well as dehydration shall be done on same day. Make: Savita/Poweroil/Castrol/Apar
S & F silica gel dark blue type laboratory grade in the transformer including removing the old one complete all as specified and directed.
Filtration/dehydration of the existing transformer oil at site of any make of transformer and capacity up to required dielectric strength as per IE rules and refilling in the transformer up to required level complete all as specified and directed. Note:-The die electric strength shall not be less than 50 KV after filtration process.
Supply and fix in replacement of alluminium body silica gel breathers of standard size suitable for 400 to 500 KVA transformers 11 KV/433 volts transparent type including removing the existing old unserviceable silica gel breathers complete all as specified and directed.
All as per item No 13 above but below 400 KVA
Supply and fix transformer oil temperature gauge of standard size suitable for 100 to 500 KVA transformers 11 KV/433 volts analogue type including removing the existing old unserviceable temperature gauge complete all as specified and directed.
Supply and fixing of HT bushing with brass studs 11 KV including gasket nut bolts washers etc complete suitable for any type or any size of transformer including removing the existing HT bushing complete all as specified and directed.
Supply and fixing of brass LT studs including gasket nut bolts insulator washer etc complete suitable for transformer of cap upto 200 KVA including removing the removing the existing LT studs complete all as specified and directed.
All as per Item No 17 above but of capacity from 250 to 500 KVA.
M&L for shifting after disconnection of transformer from the existing side and install/commission at proposed site (within jurisdiction of GE Dehradun) same for outdoor type HT 11KV/433 V 3 phase, 50Hz with off load tapping and standard fitting up to 200 KVA including connection/testing with proper load balancing as per engineering practice, confirming to IS 2026 including connected panel all as directed. Note: Item rate includes necessary transport, tools & plant and labour lugs thimble PVC sleeves etc required for shifting, installation, connection and commissioning of transformer complete all as specified and directed..
All as per item No 19 above but capacity 250 to 500 KVA.
M&L for repair to servo stabilizer 25 KV including transportation of stabilizer to workshop and dismantling of all parts including taking out of coil assembly, repair to winding and baking for removal of moisture, replacement of oil seal, stud, nut, bolt, repair to servo motor, replacement to faulty cards etc and making all necessary wiring and minor repair for automatic operation of servo stabilizer complete including fixing of repaired servo stabilizer to MH Dehradun including all necessary connections complete all as specified and directed. Note: Windings, dehydration of oil, New Oil and other accessories shall be measured and paid for separately.
M & L for switch air break gang operated triple pole out door type with drop out switch fuse unit on HT 11 KV 50 cycle AC suitable for current rating up to 200 Amps mechanically operated mounted on cast resin rubber insulators (12 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete all as specified and directed. Make :- Elpro/Pactil/ Alstom/MEI/ATLAS
S & F horn gap type of fuses mounted on post insulators with gun metal clamps and copper horn complete of required capacity to suit load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed. Make :- Elpro/ Pactil/ Alstom/MEI/ATLAS
M&L for shifting after disconnection/dismantling of LT panel from the existing location and reassembling install/commission and testing at proposed site (within jurisdiction of GE Dehradun) same and standard fittings including connection/testing with proper load as per engineering practice, confirming to IS including connection of LT panel with power transformer allied works complete all as specified and directed. Note: Quoted rate shall be inclusive necessary transport, tools & plant, labour and LT cable connection, excavation PCC etc required for shifting, installation and commissioning.
S&F of Cable route indicator showing "MES HT U/G cable 11 KV" or "MES LT U/G cable" and route of cable with arrow made of CI in suitable eliptical shape and fixed with MS rod 12mm dia, 70 cm long (all words embosed) and fixed in position, complete all as specified.
M & L for under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 11000 volts (earthed) grade copper sheet wrapped cross sectional area 240 sqmm 3 core including taking down of old unserviceable complete all as specified and directed. Make:- Havell/Finolex/KEI/Polycab
All as per item No 26 above but 185 Sqmm 3 core
All as per item No 26 above but 150 Sqmm 3 core
All as per item No 26 above but 120 Sqmm 3 core
All as per item No 26 above but 95 Sqmm 3 core
M & L for cable end jointing kit for 11 KV (earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 240 to 300 sqmm including testing after jointing complete all as specified & directed. Make: Havells/Raychem/3M Birla/Denson
All as per item No 31 above but 120 to 185 Sqmm 3 core
All as per item No 31 above but 95 Sqmm 3 core
M & L for cable end jointing kit for 1.1 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of 240/300 sqmm including testing after jointing complete all as specified & directed. Make: Havells/Raychem/3M Birla/Denson
All as per item No 34 above but 120 to 185 Sqmm 3.5 core
All as per item No 34 above but 50/70/95 Sqmm 3.5 core
Material and labour for CPRI approved chemical earthing complete with GI pipe electrode 50 mm dia, 2 Mtr long with terminal size 50x6 mm buried directly in ground not less than 2.25 m deep below normal ground level connected with and including galvanized wire 4 mm earth lead upto pole/panel by means of nuts bolts check nuts GI washers etc duly protected by galvanized iron pipe 15 mm bore (light grade) including PVC accessories well and cover and gel type back fill compound necessary earth work in soft/loose soil, testing on completion including demolition of existing earthing complete all as specified and directed. Make; SNE/OBO/ENNOVE. NOTE. Note:- 1. The unit rate includes for protection GI pipe 15 mm dia light grade and GI wire 4 mm dia from top of earth plate up to 7.5 meter above ground level.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32x6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR part 1 including testing on completion all as specified and directed. including demolition to existing earthing complete.NOTE 1. The unit rate includes for protection pipe 40 mm dia and GI strip 32x6 mm dia from top of earth plate up to 7.5 meter above ground level.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
M&L for fine and clean sand (river sand) free from sharp materials in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed by Engineer in Charge. Note:- The total thickness of sand shall be measured 18 cm after punning.
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and as directed by Engineer in charge.
M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
M & L PCC (1:3:6) type C-1 (with using 20 mm graded stone aggregate) as coping of pole including necessary form work as required complete all as specified and as directed.
M&L 80 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint complete all as specified and as directed. (Make TATA/JINDAL/swastik/BST).
Excavation over area n. exc 1.5 m deep and getting out in soft/loose soil including dressing up soil etc for laying of gravel in sub stn or switch yard complete all as specified and directed.
Surface excavation not exceeding 15 cm deep including dressing up soil etc for laying of gravel in sub stn or switch yard complete all as specified and directed.
M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation of transformer plinth, paver blocks etc complete all as specified and as directed.
M& L for 150 mm thick gravel 20 mm graded packed in 33 or 11KV outdoor sub stn yard complete all as specified and directed.
M&L for laying of Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and without pigment complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x20cm x 25mm thick, set, jointed and pointed in neat pigmented cement slurry in floors including taking out old existing tiles complete all as specified and directed.
M& L for brick work for construction of platform with steps for transformer with sub class 'B' brick straight or curved on plan exc 6 m radius built in CM 1:4 complete all as specified
M&L rendering 15mm thick in CM (1:4) on fair faces of brick or concrete surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for filling of red bajri or moorum in floor or in foundations spread, leveling and ramming including watering complete all as specified and directed.
M&L for RCC 1:2:4 (Nominal Mix) type B-1, using 20 mm grade aggregate for slab supported on walls incl form work required for the same complete all as specified and directed.
M & L for TMT bars for RCC work including cut to shape in suitable length, binding with mild steel wires complete of min 10 mm dia complete all as specified and directed.
Disconnecting of HT/LT Connections incl drain out of oil in barrels and kept aside for reuse and lifting with crane incl transportation of transformer 3.15 MVA and oil etc at civil workshop (Transtron Meerut or auth OEM workshop) for necessary repair work complete and returned back after repair incl commissioning etc complete all as specified and directed.
Dismantling of transformer for repair 3.15MVA removing & lifting of top plate of transformer burnt oil seal, stud, nut, bolt, HT bushing, off load tap changer, butcholz relay, gate valve, dead plug etc for repair to core and winding incl taking out of the same & replacing with following new and repair for minor leakages (if any) and fixed the same complete incl top up the oil after dehydration complete all as specified and directed.
(a) 12 KV/630 Amp L. V bushing with complete copper metal parts
(b) Buchholz Relay 50 mm
(c) Magnetic oil guage (150 mm)
(d) Oil Temperature Indicator (O.T.I) with Alarm and trip contacts
(e) Winding Temperature Indicator (W.T.I) with Alarm and Trip Contacts
(f) Marshalling Boz with Wiring
(g) Set of gasket
(h) Silica gel Breather (Aluminium Body)
(j) Arcking Horns
M&L for repair to On load tap changer of 3.15 MVA transformer incl replacement of wiring contactors, connectors incl wiring control cable connection and connection with on load tap changer panel and making system fully functional etc complete all as specified and directed
M&L for 3.15 MVA transformer windings incl taking out and testing for serviceability and rewinding the same with fresh copper wire or strip incl insulation paper bobins etc and keeping the same in to the hot air oven till the moisture is removed & insulation resistance improves to the satisfaction level, refixing the same in original position complete.
Supply and fixing of automatic voltage ragulating relay suitable 3.15 MVA transformer on load tap changer incl connections of control wires etc and making system fully automatic complete all as specified and directed Make Pradeep/Sukura/ABB
Supply installation commission and testing of OEM partially type tested relay and control panel indoor type, suitable for 33 KV VCB of system voltage LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) and 110 Volts DC factory assembled, weather and vermin proof (Protection Class IP-54) fabricated out of 2.0 mm thick CRCA sheet withback side hinged opening, rubber lining, locking arrangement, powder coated externally and internally of shade RAL 7032 siemens grey mounted on 75 medium channel frame incl cable Glands of suitable to accommodate incl taking down old u/s panel complete Make of Panel:- ABB/Venson/Legrand and including following :- (a) 3 Pole micro processor based feeder cum transformer protection relay with instantaneous 2 Nos over current (50, 50N) element and 1 No Instantaneous earth fault (50, 50N) (o/c setting 50% - 200% and earth fault setting 20 % - 80%, transformer protection against temperature etc having large LCD display of all the parameters ie all three phase current at a time, type of fault, fault history etc operating voltage 24 Volts DC -01 No Make ABB Cat No RET 615 or Equvalent in Schneider/Siemens (b) 3 pole Earth fault relay -01 No (c) Auxilliary relay - 01 No (d) Large size digital LED Volt Meter -01 No (e) Large size digital LED Amp Meter -01 No (f) Digital three line multifunction LED display meter -01 No (g) CT Operated three phase trivector meter -01 No (h) Mechnical ON/OFF indicator- 01 No (j) Trip/charge switch -01 No (k) Space Heater -01 No (l) Cubical illumination lamp -01 No (m) LED Indication lamps for Spring charge, Breaker ON/OFF, Trip, Healthy etc (n) Hooter 01 No (o) Instrument wiring with suitable size copper condictor cable and conrolled with suitable size SP/DP/TP/FP AC/DC MCB's -01 Job (p) Annuciation panel -01 No (q) Trip circuit supervision relay -02 Nos
Supplying in replacement of existing unserviceable control cable including laying or fixing with saddles or cable tie etc, jointing and testing LT PVC insulated copper conductor armoured electric power cable ISI marked with multistranded copper conductor heavy duty 1100 volts grade of 2.5 Sq mm 4 core complete all as specified and directed incl disconnection and taking down existing complete.Make: Havells/Polycab/Finolex/Simens.
All as per item No 64 here and above but 2.5 Sqmm 12 core
KAPOOR ELECTRICALS
M/s Kamal Traders
Amit Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .