Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹75.9 L+₹6.7 L (9.64%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹76.3 L
EMD Value
₹50,000
Closing Date
11 Aug 2022, 6:55 pmClosed
Chief Electrical Engineer
Office of the Chief Electrical Engineer, PWD Electrical Wing, Public Office, Thiruvananthapuram
DEPOSIT Electrification to the newly constructed building for the Guest House Ponmudi Electrification General Electrical Work-Electrification to the newly constructed building for the Guest House Ponmudi Electrification General Electrical Work
2022_PWD_501117_1
PWD/BLDG/TR/13570/2022_6_1_1/1
Open Tender
Electrical Works
Item Rate
150 days
Ponmudi
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
5 Jan 2023
26 Jul 2022
16 Aug 2022
26 Jul 2022
11 Aug 2022
26 Jul 2022
26 Jul 2022 - 11 Aug 2022
Amount
ELECTRIFICATION
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.2:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Twin Control light point with 6A, plate ceiling rose - Short point
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
90.2.1.5:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
90.3.10:Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD88779/2022-2023: Supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19 mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. as required( Model No WT201 LED 44S 6500 PSU L 120)/or equilent ( Kitchen/Pantry)
OD88780/2022-2023:Supply and fixing of Recess type -Green Space Flex down lighters, with extremely low glare (UGR <19).The range is available in narrow (15°), medium(24°) & wide beam (38°) optics, suitable for different applications & ceiling heights etc and giving connection as required( Model no RS378BMR 16D92 R-R FXD ) or equilent.
OD88781/2022-2023:Supply and fixing of Recess type -Green Space Flex downlighters, with extremely low glare (UGR <19).The range is available in narrow (15°), medium(24°) & wide beam (38°) optics, suitable for different applications & ceiling heights etc and giving connection as required(Model no RS 378Z M70D 110 R-R AJD make) or equilent.
OD88782/2022-2023:Supply and fixing of Recess type -Green Space Flex downlighters, with extremely low glare (UGR <19).The range is available in narrow (15°), medium(24°) & wide beam (38°) optics, suitable for different applications & ceiling heights etc and giving connection as required( Model no RS 378Z M87D130 R-R AJD make philips)
OD88783/2022-2023:Supply and fixing of Sky Cove LED Strip cove lighting with reliable performance and excellently waterproof, anti-dust LED strips with professional design for Warm white colors with driver(6500K) of 5m length supply and giving connection etc as required.( Model No SKY Cove 5M WW with Driver Make -Philips or Equivalent)
OD88784/2022-2023: Supply, installation, testing and commissioning Sleek Surface Down light Slim profile surface mounted 7W warm color down light with efficacy not less than 110lm/W ( Model no SM250C LED7S- 6500 PSU WH ) or equilent
OD88785/2022-2023:Supply and fixing of 312mm X 312mm surface mount indoor general lighting and giving connection etc including making good the damages, colour washing etc as required.( Model No SM200C LED 16S 6500PSU OD WHMake - ) or equivalent (Front Porch)
OD88786/2022-2023: Supply and fixing surface mounted down light fitting Model no: SM251C LED16S-6500PSU WH or equilent ( Basement floor Parking Area)
OD88787/2022-2023:Supply and fixing of decorative lighting clear glass with gold finishing wall lamp, E27 LED 7Wx1 Gold Finish color lamp with RoHS compliant, duly wired up for use on 230 V AC supply and giving connection etc.including making good the damages, colour washing etc as required.( Model No KCH-GLD-MB 120010121A )(Balcony) - or equilent
OD88788/2022-2023: Supply, installation, testing and commissioning of Clear Glass, Rose Gold mesh with Chrome finishing pendent ceiling light fitting with G9 LED 4Wx1 and RoHS compliant, duly wired up for use on 230 V AC supply and giving connection etc. including making good the damages, colour washing etc as required.( Model No JES-CHR-MB160275531B) or equivalent ( Coffee shop) -
OD88789/2022-2023:Supply, conveyance installation testing of pre -wired LED 6LT Champagne Opal Glass& Chrome Finish Chandelier light E-14 LED 4Wx6 fixing on ceiling using necessary specials and giving connection with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS and giving connections as required.( Model no -KCH-CHR-MD 150330026A)( Entrance Reception) - Jaguar make
OD88790/2022-2023:Supply, conveyance installation testing of pre -wired LED Crystal Chandelier light for Decoration and brass material Gold& Chrome color fixing on ceiling using necessary specials and giving connection with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS and giving connections as required. (model No- 9111 LED Jaquar UMBRA modern Crystal Chandelier light for Decoration ( Banquet hall)
OD88791/2022-2023:Supply and fixing of LED Room Bed light fittings 830 warm white poly carbonate bowl and giving connection etc.including making good the damages, colour washing etc as required.( Model No BWG150150/ww PSU 220-240V IP677043 Philips) (All Bed rooms)
OD88792/2022-2023:Supply and fixing of 2W LED Step light fittings 3000K dimension 80x80x40 mm with RoHS compliant, duly wired up for use on 230 V AC supply and giving connection etc.including making good the damages, colour washing etc as required.( Model No 30974-Philipsor Equivalent) ( Stair case step light)
OD88793/2022-2023:Supply and fixing of 12W Mirror lamp warm white 3000k dimensions (LxDxH) mm 500x180x95 with RoHS compliant, duly wired up for use on 230 V AC supply and giving connection etc.including making good the damages, colour washing etc as required.( Model No Gold 31403 Make -Philips or Equivalent)(VIP room Mirror lamp)
OD88794/2022-2023:Supply,fixing of LED 7w integrated chrome finish picture light of 3000k with APF electronic drive suitable for continuous operation Dimensions (LxDxH 355mmx180x95 and duly wired up for use on 230 V AC supply and giving connection etc.including making good the damages, colour washing etc as required.( Model No31402- Make -Philips or Equivalent)
OD88795/2022-2023:Supply and fixing of chrome finish with glass wall light fitting with 11 W LED warm white lamp with RoHS compliant, duly wired up for use on 230 V AC supply and giving connection etc including making good the damages, colour washing etc as required.( Model No 31167 -Philips or Equivalent) -( Room mirror wall lamp)
OD88796/2022-2023:Supply, conveyance installation testing and commissioning of wall lamp 2way clessy anthracite matte finish with alu: with gray powder coated 10W LED lamp and 670lm IP 65 CCT-3003 k and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.(Philips make 31450 10-Watt Up Down Lighter Anthracite and Warm White or equivalent)(court yard light)
OD88797/2022-2023:Supply, conveyance, installation, testing and commissioning of fancy light fitting wall mounted,wall light Antique brass color E27 lamp base 2x7w A60 LED filament lamp IP 20 and giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required( Model No Adelia WL 2LS E 27 ABR make Havells or equilent )(All rooms)
OD88798/2022-2023:SITC of Endura LED 10W bulkhead fittings with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.
OD88799/2022-2023:Supply conveyance, installation ,testing and commissioning of LED bulkhead fittings IP 65 directly on wall including cutting necessary holes giving connection with the extended original wiring making good the damages colour washing etc as required(Philips/Bajaj/Havel's/Wipro)
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
90.5.1.4:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Musical bell with bird sound
OD88800/2022-2023:Supply and Fixing of 9W LED Bulb
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
OD88801/2022-2023: Supply and Installation of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, including making good the damage connection testing, commissioning etc. as required.
OD96711/2022-2023:Supply and fixing 400mm Metal body wall fan including giving connection, etc as required (400 mm metal body wall fan of M/S Almonard /Equivalent)
OD88803/2022-2023:Supply, conveyance, installation, testing and commissioning of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.(Usha Fontana Maple 1250mm 5 Blade ceiling fans (Antique Brass,) or equilent (VIP Bed room)
OD88804/2022-2023:Supply, conveyance, installation, testing and commissioning of Usha Aldora 1320mm premium ceiling fans (Antique Copper)of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.(Usha Aldora 1320mm premium ceiling fans (Antique Copper) or equivalent)(All rooms)
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.6.4.2:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 2 Run
90.6.4.3:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 3 Run
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.18:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
90.6.4.56:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 6 Run
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD88805/2022-2023:Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required.
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
OD88806/2022-2023:Supplying and fixing key tag with key fob on the existing modular plate & switch box including connections and modular plate etc. as required. 2 module 25A ,230v key card switch with key fob as required. (Make Legrand or its Equivalent)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
OD88807/2022-2023:Supply, conveyance and fixing the following types & current rated Contactor with AC Coil suitable for 240V 50 Hz in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 25 A 3 pole Make L&T or its Equivalent
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover
90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer
90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box
90.9.2.14:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box
90.9.2.24:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat Tee
90.9.2.25:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal Tee
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
OD88808/2022-2023:Supply and fixing of FP enclosure for independent mounting of MCB/ RCCB/ Isulator etc are testing and commissioning as required.
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
OD88809/2022-2023:125 A, 25 kA (Ics=100%Icu), 4 pole, 440 V, 50 Hz, AC current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release conforming to IS 13947. with extended terminal
OD89070/2022-2023:250A, 36 kA (Ics=100%Icu), 4 pole, 440 V, 50 Hz, AC current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release conforming to IS 13947. with extended terminal
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
90.14.24.68:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.71:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
OD88810/2022-2023:Supply & fixing the following accessories in positon and giving connection. 8 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
OD88811/2022-2023:Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as required
OD88812/2022-2023:Supply and fixing Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
OD88813/2022-2023:Supply and providing Multi function meter to read: V, A, F, 3 phase accuracy class 1
OD88814/2022-2023:Supply and providing Blue colour LED indicator lamp, AC/DC, 22.5 cm cut out dia
OD88815/2022-2023:Supply and providing Red, Green, Black, Yellow, Orange colours LED indicators, AC/DC 22.5mm cut out dia
OD88816/2022-2023:Supply and fixing of 250/5A, 5VA accuracy class 1, Resin Cast Metering CT and giving connection as required.
OD88817/2022-2023:Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required
OD88818/2022-2023:Supply and Fixing of Illuminated Flush head Actuator - Red with legend 'OFF', (Contact - 1 NC) and giving connection etc as required.
OD88819/2022-2023:Supply and Fixing of Illuminated Flush head Actuator - Green with legend 'ON', (Contact - 1 NO) and giving connection as required.
OD88821/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 4 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD88822/2022-2023:Supply, providing and giving connection of Surge protection Device 3P+N, 100 KA protection against direct and indirect lighting surges as required.
OD88823/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD88824/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.- 1.5 sq mm single run with required sockets.
OD88825/2022-2023:Charges for Cleaning and Painting of the existing panel board installed position with one or more coats of painting with synthetic enamel paint of approved brand and Colour by using Spray Gun and Compressor etc.
OD88826/2022-2023:charges for dismantling and re fixing in the following size of PVC insulated and PVC sheathed / aluminum conductor cable of 1.1 KV grade as required.
90.12.1.28:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 35 sq mm
90.12.1.29:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 50 sq mm
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.1.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm
90.12.1.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
90.12.7.27:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.9.5:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench90/75 mm or nearest size
90.12.9.10:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench160/135 mm or nearest size
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.20:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
7.9:Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
OD88827/2022-2023:Supply and providing plate earthing with 1200x1200x12mm GI/CI earth plate, 50mm GI watering pipe, GI funnel with weld mesh, 25x3mm GI clamps, charcoal etc, including providing brick work masonry enclosure at top (450x450x450mm inside) including Gully trap with covering box in CI (450x450x10mm) but excluding earth continuity conductor and test joint as required.
90.16.3.11:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 3 mm copper strip
90.16.4.10:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 3 mm copper strip
OD97564/2022-2023:Supply and laying the following sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required.32x3mm copper strip tinned at the point of contact.
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD88828/2022-2023:Supply and providing 25x6mm brass nut and bolt etc. as required.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD88829/2022-2023:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD88831/2022-2023:Supply, conveyance, Installation, testing & commissioning of 160 KVA Diesel Generator set with AMF control panel and integral acoustic enclosure as per CPCB norms accessories as per technical details given below. 1. Engine : a) Make of Engine - as specified in MOM b)Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) Exhaust Muffler j) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - as specified in MOM b) Type - Self exited and self regulated. c) Capacity - 160 KVA/128 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall be done as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. Inbuilt solid state Battery charger, phase indication lamp for supply ON/OFF with HRC protection. standard control panel as per kerala Electrical Inspectorate requirements, with 250 A 4 pole MCCB 25 KA t/m 100 % Ics and accessories such as Multi function meter and separate Energy meter etc.The AMF panel fabricated as a separate unit with 250A pole ATS with AMF relays, have sufficient space for glanding /clamping suitable cable rated for 160 KVA DG, 36 months warranty from date of commissioning
OD91506/2022-2023:Supply and filling Diesel for DG set
90.17.7.9:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm)
OD88832/2022-2023:Supply & laying of laying of 1 no. 11 KV grade XLPE cable of the following sizes in ground including excavation of trench of size 1.2 m, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3 core 185 sq mm
OD88833/2022-2023:Supply, laying and clamping of 1 no. 11 KV grade XLPE cable of the following sizes using clamps fabricated from 20 x 3 mm MS flat, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. 3 core 185 sq mm
OD88834/2022-2023:Supply,Conveyance,Installation,testing,and Commissioning of Out door type IP 54 rated OUT DOOR Metering panel made of 2 mm thick CRCA sheet powder coated after 7 tank process with canopy consisting 11kv, 630amps, 350MVA, 3ph, 50hz load break swith , HT HRC fuses, earth switch, Mechanical interlocks, 0.2s CT/PT of required ratio as suggested by the KSEB, thermal censer with space heater, 0.2s -/5A or -/1 A HT TOD meter as per present KSEB standards & KSEB sealing facility .
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.22:Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
10.4.3:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:240 sq. mm
OD88836/2022-2023:Engaging one wire man and one wire man assistant for cleaning the existing switch box, checking wiring, fixing switch, plug water heater etc
OD88837/2022-2023:Supply and providing 6 Kg. ABC Fire Extinguisher with hose and clamps including fixing it to wall as required.
10.5.3:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 sq. mm
OD88838/2022-2023:Supply of Roof conductor holder for parapet-polyimide conductor holder. with M8 female thread or diameter 7mm, M8 screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance as required. No.17730 M8(5207460)OBO or its equivalent make. (Down Conductor)
OD88839/2022-2023: Supply of Roof conductor holder for parapet-polyimide conductor holder. with M8 female thread or diameter 7mm, M8 screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance as required. No.17730 M8(5207460)OBO or its equivalent make. (Air Terminal)
OD88840/2022-2023:Supply of Test Joint (Folding clamp) made of SS, suitable to connect 8mm round conductor and max by 30x3 mm GI strip as required. OBO/ equivalent make No. 2718-10 (5317481)?2528-10V4A.
OD88841/2022-2023:Supply of Galvanized Steel Flat 30 mm X 3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of hot dipped & cross sectional area of 90mm square. According to DIN EN 50164-2(VDE 0185 part 202) Meets the requirements of VDE0185/305 ( IS- IEC 62305 ) Zinc coating 500g/m square should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. No. 5052 DIN 30X3(5019344). OBO/CAPE or its equivalent make.
OD88842/2022-2023:Supply and providing CHEMICAL EARTHING system , of UL Listed & CPRI Tested maintenance free, Low carbon copper coated earth rod of 3 meter electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 25kg/pit tested as per IEC 62561-7, TCLP tested. The above arrangements shall be provided with heavy duty earth chamber of 5000kg load Bering capacity to ensure the safety of earthing system.
OD88843/2022-2023:Supply of 8mm Aluminium round conductor complete as specified in drawing & Meets the requirements of din EN 50164-2 ( VDE 0185 part 202) & VDE 0185-305 (IS / IEC 62305 ,the conductor fixing horizontally on the FLAT CONCRETE ROOF SLAB / parapet of the building on the existing holder OBO or its equivalent make.(Air Terminal)
OD88844/2022-2023:Supply of 8mm Aluminium round conductor complete as specified in drawing & Meets the requirements of din EN 50164-2 ( VDE 0185 part 202) & VDE 0185-305 (IS / IEC 62305 ,the conductor fixing horizontally on the FLAT CONCRETE ROOF SLAB / parapet of the building on the existing holder OBO or its equivalent make. (Down conductor)
OD88845/2022-2023: Providing of expansion piece with connector. For equalizing temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU.(No. 172 AR (5218926) OBO/equivalent.
OD88846/2022-2023:Supply and providing of Cross connector for Flat suitable for 30 mm Galvanised steel strip. installed with 4 nos of hexagonal plate. no: 255 FL30FT (5214534). OBO/equivalent.
OD88847/2022-2023: Supply and providing connector for T cross and parallel connectors . Quick installation using Hexagonal bolt M10X30 high grade hot dip galvanised . conforms to the reqiurements according to DIN VDE 0185-305(IS-IEC 62305) (2 nos /expansion piece ) no: 2498-10ST(5311500) OBO/equivalent.
OD88848/2022-2023:Supply, conveyance and fixing of Cross universal connector for T and cross connection, to route vertical down conductor/mesh formation made of hot dipped galvanized iron with necessary screws etc as required. installed with 4 hexagonal bolt M8*25 with M8 hexagonal bolt & nut etc and fixing the conductor properly as required. OBO/ equivalent make.
OD88849/2022-2023:Vertical air terminal with accessories: Providing of Air terminals as per IS-IE-62305 PART- 3 16 mm tapered to 10mm aluminum rod ; Meets the technical specification according to DIN EN 50164-2 (VDE 0815 Part 202) meets the requirement of VDE 0185/305 (IS /IEC 62305) OBO/equivalent.
OD88850/2022-2023:Supply of Ridge Holder with Tensioning spring Made of SS304 Grade , for routing Round conductor of 8mm , having the clamping range of 280-380mm ridge . no : 132 U 35 (5203018) OBO/equivalent.
OD88851/2022-2023:Supply and providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts. no: 166 LS 70(5226 570) . OBO /equivalent.
OD88852/2022-2023:Supply and providing of Plastic corrosion Protection strip Approx 1.1mm thick. width 50mm Made of petrolatum-coated chemical fiber fabric as required. No. 35650(2360055) OBO/equivalent.
OD91396/2022-2023:Copying charges of Electrical/fire Drawing per A 3 sheet additional copies
OD91397/2022-2023:Charges for preparation of Electrical/fire Drawing per A 3 sheet first copy
S K Electrics and Infrastructures
Bidder Name
D SURESH
S K Electrics and Infrastructures
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_718107.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .